Standex TRI-STAR TSHHP-212i User manual

1
INSTALLATIONANDOPERATINGINSTRUCTIONS
HeavyDutyHotPlates
MODELS:TSHHP‐212i/TSHHP‐424i/TSHHP‐636i/TSHHP‐848i
TSHHPS‐212i/TSHHPS‐424i/TSHHPS‐636i/TSHHPS‐848i
P/N: 8835525 08/13
TRI-STAR MANUFACTURING
DALLAS: CHEYENNE:
1307 N. Watters Rd #180 •Allen, TX •75013 1938 Wyott Dr •Cheyenne, WY •82007
Local: (972) 908-6100 Local: (307) 634-5801
Toll Free: (800) 733-2203 Toll Free: (800) 752-0863
Parts/Service Fax: (214) 565-0976 Parts/Service Fax: (214) 565-0976
www.tri-starmfg.com

2
TABLE OF CONTENTS
SECTION ITEM PAGE
1 Safety Precautions………………………………………………………...2
2 General Installation Instructions………………………………………….4
3 Specifications………………………………………………………………4
4 Lighting Instructions……………………………………………………….7
5 Maintenance………………………………………………………………. 8
6 Conversion………………………………………………………………… 9
7 Replacement Parts Lists & Exploded Views……………………………11
8 Warranty…………………………………………………………………… 16
LOCATION OF DATA PLATE
The data plate for the gas open burner range is located on the right side panel.
IMMEDIATELY INSPECTFOR SHIPPING DAMAGE
All containers should be examined for damage before and during unloading. The freight carrier has
assumed responsibility for its safe transit and delivery. If equipment is received damaged, either
apparent or concealed, a claim must be made with the delivering carrier.
A) Apparent damage or loss must be noted on the freight bill at the time of delivery. It must then be
signed by the carrier representative (Driver). If this is not done, the carrier may refuse the claim.
The carrier can supply the necessary forms.
B) Concealed damage or loss if not apparent until after equipment is uncrated, a request for inspection
must be made to the carrier within 15 days. The carrier should arrange an inspection. Be certain to
hold all contents and packaging material.
Installation and start-up should be performed by a qualified installer who thoroughly read, understands
and follows these instructions.
If you have questions concerning the installation, operation, maintenance or service of this product,
write Technical Service Department Tri-Star Manufacturing, 1307 N Watters Rd # 180, Allen, TX 75013.
1. SAFETY PRECAUTIONS
Before installing and operating this equipment be sure everyone involved in its operation is fully trained
and is aware of all precautions. Accidents and problems can result by a failure to follow fundamental
rules and precautions.
Shut off gas flow through the appliance before cleaning or servicing unit.
The following words and symbols, found in this manual, alert you to hazards to the operator, service
personnel or the equipment. The words are defined as follows.

3

4
GAS PRESSURE
The appliance and it’s individual shutoff valve (to be supplied by user) must be disconnected from the
gas supply piping system during any pressure testing of that system at test pressures in excess of ½
psi (3.45 kPa). NOTE: Gas shutoff valve is supplied on CE models.
The appliance must be isolated from the gas supply piping system by closing its individual manual shut-
off valve during any pressure testing of the gas supply piping system at test pressures equal to or less
than ½psi (3.45 kPa).
Congratulations on your purchase of Tri Star commercial cooking equipment. Tri Star Manufacturing
takes pride in the design and quality of our products. When used as intended and with proper care and
maintenance, you will experience years of reliable operation from this equipment. To ensure best
results, it is important that you read and follow the instructions in this manual carefully.
The countertop hot plate, models TSHHP-212i, TSHHP-424i, TSHHP-636i, TSHHP-848i, TSHHPS-
212i, TSHHPS-424i, TSHHPS-636i and TSHHPS-848i provide countertop heating and cooking
capabilities. These units incorporate 2, 4, 6 or 8 burners for fast, even cooking and heating. Refer to
data plate for BTU/hr Rate.
2. GENERAL INSTALLATION INSTRUCTIONS
Ensure gas supply and gas type shown on unit data plate match. (Data plate is located on the right side
panel of unit).
Unit installation must conform to the National Fuel Gas Code, ANSI Z223.1/NFPA 54, the National Gas
Installation Code, CSA B149.1, or the Propane Installation Code, CSA B149.2 as applicable and in
accordance with local codes.
Screw legs into the permanently fastened nuts on the four corners of the unit and tighten by hand.
Level the unit by turning the adjustment screw at the bottom of each leg. Do not slide unit with legs
mounted, lift if necessary to move unit.
Pipe gas supply to unit. The gas supply (service) line must be the same size or greater than the inlet
line of the appliance.
Pipe threading compound must be resistant to the action of liquefied petroleum gases.
These units are suitable for installation on non-combustible surfaces.
Unit must have adequate clearances for servicing. (Sides = 0", Rear = 0", Floor = 4")
Commercial cooking equipment must have a pressure regulator on the incoming service line for safe
and efficient operation, since service pressures may fluctuate on local demand. A pressure regulator is
packed inside every Tri-Star appliance.
Failure to install the pressure regulator will void the appliance warranty.
Prior to connecting the regulator, check the incoming line pressure, as these regulators can only
withstand a maximum pressure of ½'' psi (14" WC). If the line pressure is beyond this limit, a step down
regulator will be required.

5
3. DIMENSIONS AND SPECIFICATIONS
MODEL WIDTH (A) DEPTH (B) HEIGHT (C) LEG
SPACING (D) LEG
SPACING (E) REGULATOR
SPACING (F)
TSHHP-212i 12” 32” 14” 8-1/2” 23-1/2” 4”
TSHHP-424i 24” 32” 14” 20-3/4” 23-1/2” 4”
TSHHP-636i 36” 32” 14” 32-3/4” 23-1/2” 4”
TSHHP-848i 48” 32” 14” 44-3/4” 23-1/2” 4”
TSHHPS-212i 12” 32” 14” FR / 17” RR 8-1/2” 23-1/2” 4”
TSHHPS-424i 24” 32” 14” FR / 17” RR 20-3/4” 23-1/2” 4”
TSHHPS-636i 36” 32” 14” FR / 17” RR 32-3/4” 23-1/2” 4”
TSHHPS-848i 48” 32” 14” FR / 17” RR 44-3/4” 23-1/2” 4”
MODEL # of
BURNERS
BTU/hr PER
BURNER
NAT GAS
BTU/hr
TOTAL
NAT GAS
BTU/hr PER
BURNER
PROPANE
BTU/hr
TOTAL
PROPANE
in W.C.
NAT GAS In W.C.
PROPANE
TSHHP-212i 2 30,000 60,000 25,000 50,000 5 10
TSHHP-424i 4 30,000 120,000 25,000 100,000 5 10
TSHHP-636i 6 30,000 180,000 25,000 150,000 5 10
TSHHP-848i 8 30,000 240,000 25,000 200,000 5 10
TSHHPS-212i 2 30,000 60,000 25,000 50,000 5 10
TSHHPS-424i 4 30,000 120,000 25,000 100,000 5 10
TSHHPS-636i 6 30,000 180,000 25,000 150,000 5 10
TSHHPS-848i 8 30,000 240,000 25,000 200,000 5 10

6
4. LIGHTING INSTRUCTIONS
HHP and HHPS Gas Open Burner Ranges are furnished with either a pilot safety valve or a standing
pilot (not available in the European Community). Please follow the instructions for your unit.
Pilot Operation Flame Failure Gas Valve:
Operation of the gas valve pilot:
1. Turn knob on the main gas valve to the pilot position
2. Depress knob to start gas flow to the pilot valve
3. Light pilot valve
a. Using a match or taper
4. Hold in knob for 15 to 30 seconds to heat up the thermocouple
5. Release knob and turn to the desired gas flow position
a. If pilot goes out repeat steps 1-4, some thermocouples will take longer to heat up
Standing Pilot Lighting Instructions (Not Available in the European Community)
The pilot lights on the broilers have been set at the factory. A screwdriver may be required for the first
lighting to adjust the flame for your elevation.
1. Turn off the manual shut off valve and wait 5 minutes to clear the gas.
2. Turn all knobs to the "OFF" position.
3. The valve can be accessed through an opening in the front panel or remove the cooking grates
and light the pilot from above.
4. Turn the manual shut off valve on.
5. Hold an ignition source (match) to both openings on the pilot tube. When the flames are
established, remove the ignition source.
6. Turn the burner knobs to “HI". If the burner does not ignite, promptly open the pilot valve more.
If the pilot flame appears larger than necessary, turn it down and reset burner ignition. The pilot
flame should be as small as possible but large enough to guarantee reliable ignition of the
burners when the knobs are turned to “HI”.
Relighting the Pilot
If the pilot light should go out for any reason:
Promptly shut off all gas at the manual shut off valve.
Turn off all knobs and pilot valves; wait 5 minutes to clear gas.
Relight following steps 4 through 6 under Standing Pilot Lighting Instructions.
Lighting the Main Burner
Since the burner is lit from constantly burning pilot, turn knobs to "HI" to put the unit in operation; then
adjust to any desired position between "LO" and "HI".
To light burner, turn knob to "max." then back off to the desired flame level. The range of
adjustment is virtually infinite between high and off. (At the small flame, there is a pre-set low).
When the broiler is first heated, it will smoke until oil used in manufacturing, preservation and dust
from storage and shipping are burned off. An hour at "max." on all burners is usually sufficient.
Turn knobs off and let cool
For first cooking, set the grates at maximum tilt position and preheat before broiling. You will have
to experiment with knob settings and grate position for each particular item.
Keep the grease/water pan with sufficient water to cover the entire bottom.
Clean regularly. Grates may be removed for washing in the sink. Brush out carbonized particles.
Thoroughly wash the grease/water pan.
CAUTION
Never attempt to move a grill section while cooking. An unexpected flare could cause severe injury.
Turn off the unit, let it cool and use potholders and/or gloves to reposition or remove. The space
between the legs at the bottom admits combustion air, DO NOT BLOCK THIS SPACE.

7
Main burner air supply:
For efficient burner operation, a proper balance of gas volume and primary air supply must be
maintained which will result in complete combustion. Insufficient air supply results in a yellow streaming
flame. Primary air supply is controlled by an air shutter on the front of the burner.
Loosen the screws on the front of the burner, and adjust the air shutter to just eliminate the yellow tips
of the burner flame. Lock the air shutter in place by tightening the screws.
European Community:
If adjustment becomes necessary in the field, it should be done by a factory authorized and
trained technician who should seal the screw after the adjustment to safeguard against un-
authorized tampering by the end user.
All burners are lit from constantly burning pilots. Turning the valve to the desired flame height is all that
is required to put the unit in service.
Do not permit fans to blow directly at the unit. Wherever possible, avoid open windows next to the units’
sides or back. Avoid wall type fans which create air cross-currents within a room.
It is also necessary that sufficient air should be allowed to enter the room to compensate for the amount
of air removed by any ventilating system. Otherwise, a subnormal atmospheric pressure will occur,
affecting operation and causing undesirable working conditions.
A properly designed and installed hood will act as the heart of the ventilating system for the room or
area in which the unit is installed, and will leave the unit independent of changing draft conditions.
All valves must be checked and lubricated periodically. This must be done by an authorized service
representative in your area.
5. MAINTENANCE
Daily:
1. Thoroughly clean back, sides, top and front of unit.
2. Clean grates daily.
Weekly
1. Clean unit thoroughly. Clean stainless steel or chromed surfaces with a damp cloth and polish
with a soft, dry cloth. A detergent may be used for cleaning. To remove discolorations, use a
non-abrasive cleaner.
2. To clean the drip pan: Remove the drip pan by grabbing the handle and pulling it out of the
opening in the front panel. To replace the pan, reverse this procedure.
3. Burner air shutter openings must be kept clean.
4. Main burner ports must be kept clean. To clean burners, boil them in a strong solution of lye
water for 15 to 20 minutes. Then either brush with a wire brush or clean gas ports with a sharp-
pointed metal instrument to insure open ports.

8
6. CONVERSION
Instructions are for conversion from Natural Gas to Propane (L.P.) on all models TSHHP and
TSHHPS.
The conversion should be done before connecting the unit to the gas supply.
Units are shipped from the factory equipped for use on natural gas. Orifices necessary for LP
(propane) are provided in a bag tied to the valve on the front panel.
oRemove the knobs and front panel.
oRemove the orifice fittings from the valve. Change the orifices to the size recommended for
propane (L.P).
oReplace the orifice fittings into the valve.
To change the regulator:

9
NOTES:

10

11
APW WYOTT EQUIPMENT LIMITED WARRANTY
APW Wyott Foodservice Equipment Company warrants it's equipment against defects in materials and workmanship, subject to the
following conditions:
This warranty applies to the original owner only and is not assignable.
Should any product fail to function in its intended manner under normal use within the limits defined in this warranty, at the option of
APW Wyott such product will be repaired or replaced byAPW Wyott or itsAuthorized ServiceAgency.APW Wyott will only be
responsible for charges incurred or service performed by its Authorized Service Agencies. The use of other than APW Wyott
Authorized Service Agencies will void this warranty and APW Wyott will not be responsible for such work or any charges associated
with same. The closest APW WyottAuthorized Service Agent must be used.
This warranty covers products shipped into the 48 contiguous United States, Hawaii, metropolitan areas of Alaska and Canada. There
will be no labor coverage for equipment located on any island not connected by roadway to the mainland.
Warranty coverage on products used outside the 48 contiguous United States, Hawaii, and metropolitan areas ofAlaska and Canada
may vary. Contact the international APW Wyott distributor, dealer, or service agency for details.
Time Period
One year for parts and one year for labor, effective from the date of purchase by the original owner. The Authorized Service Agency
may, at their option, require proof of purchase. Parts replaced under this warranty are warranted for the un-expired portion of the
original product warranty only.
Exceptions*Gas/Electric Cookline:
Models GCB, GCRB, GF, GGM, GGT, CHP-H, EF, EG, EHP. Three (3) Year Warranty on all
component parts, except switches and thermostats. (2 additional years on parts only. No labor on second or third year.)
*Broiler Briquettes,
*Heat Strips:
Models FD, FDL, FDD, FDDL. Two (2) Year Warranty on element only. No labor second year.
*Glass Windows, Doors, Seals, Rubber Seals, Light Bulbs:
In all cases, parts covered by extended warranty will be shipped FOB the factory after the first year.
Portable Carry In Products
Equipment weighing over 70 pounds or permanently installed will be serviced on-site as per the terms of this warranty. Equipment
weighing 70 pounds or under, and which is not permanently installed, i.e. with cord and plug, is considered portable and is subject to
the following warranty handling limitations. If portable equipment fails to operate in its intended manner on the first day of
connection, or use, at APW Wyott's option or itsAuthorized ServiceAgency, it will be serviced on site or replaced.
From day two through the conclusion of this warranty period, portable units must be taken to or sent prepaid to the APW Wyott
Authorized Service Agency for in-warranty repairs. No mileage or travel charges are allowed on portable units after the first day of use.
If the customer wants on-site service, they may receive same by paying the travel and mileage charges. Exceptions to this rule: (1)
countertop warmers and cookers, which are covered under the Enhanced Warranty Program, and (2) toasters or rollergrills which have
in store service.
Exclusions
The following conditions are not covered by warranty:
*Equipment failure relating to improper installation, improper utility connection or supply and problems due to
ventilation.
*Equipment that has not been properly maintained, calibration of controls, adjustments, damage from improper cleaning
and water damage to controls.
*Equipment that has not been used in an appropriate manner, or has been subject to misuse or misapplication, neglect,
abuse, accident, alteration, negligence, damage during transit, delivery or installation, fire, flood, riot or act of god.
*Equipment that has the model number or serial number removed or altered.
If the equipment has been changed, altered, modified or repaired by other than an Authorized ServiceAgency during or after the
warranty period, then the manufacturer shall not be liable for any damages to any person or to any property, which may result from the
use of the equipment thereafter.
This warranty does not cover services performed at overtime or premium labor rates. Should service be required at times which
normally involve overtime or premium labor rates, the owner shall be charged for the difference between normal service rates and such
premium rates.APW Wyott does not assume any liability for extended delays in replacing or repairing any items beyond its control.
In all cases, the use of other than APW Wyott Authorized OEM Replacement Parts will void this warranty.
This equipment is intended for commercial use only. Warranty is void if equipment is installed in other than commercial application.
Water Quality Requirements
Water supply intended for a unit that has in excess of 3.0 grains of hardness per gallon (GPG) must be treated or softened before
being used. Water containing over 3.0 GPG will decrease the efficiency and reduce the operation life of the unit.
Note: Product failure caused by liming or sediment buildup is not covered under warranty.
“THE FOREGOING WARRANTY IS IN LIEU OFANYAND ALL OTHER WARRANTIES EXPRESSED OR IMPLIED
INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSES
AND CONSTITUTES THE ENTIRE LIABILITY OFAPW WYOTT. IN NO EVENT DOES THE LIMITED WARRANTY
EXTEND BEYOND THE TERMS STATED HEREIN.”
9/05
Rock Grates, Cooking Grates, Burner Shields, Fireboxes:
90 Day Material Only. No Labor.
90 Day Material Only. No Labor.
This manual suits for next models
7
Table of contents
Popular Cooktop manuals by other brands

Wolf
Wolf DD36I Use & care guide

Fisher & Paykel
Fisher & Paykel CG604C Installation instructions & user guide

Euromaid
Euromaid Hot Plates Installation and user instructions

CASO DESIGN
CASO DESIGN Touch 2000 Original operating manual

Whirlpool
Whirlpool RCS2002RS03 parts list

dipo INDUCTION
dipo INDUCTION TCK60-E user manual

Viking
Viking RDGSU2005B installation instructions

Verona
Verona VEECT110VF Series User operating instructions

Kleenmaid
Kleenmaid ICT9030 Instructions for use and warranty details

Frigidaire
Frigidaire FFGC2605LWA installation instructions

EURO
EURO EGZ90GS Use & installation guide

Blanco
Blanco BCGC74 - BCGC52 Use, installation and maintenance instructions