Star mG-S Series Installation instructions

Assemble the Scale
1Make sure the slide is
in Unlock position.
2Put the Pan Base on the scale.
Thank You for Purchasing Star’s mG-Scale!
WARNING: PRODUCTS SOLD ON A SCALE THAT IS NOT PROPERLY REGISTERED CAN RESULT IN LEGAL ACTION.
mG-S322
Round Pan Windshield box AC-AdapterPan Base Main Unit USB Cable Parts for Sealing
Check Supplied Accessories
https://starmicronics.com/Pages/mgscalessupport
Scale Support Guide mG-S Series
37967880
Copyright © 2018 Star Micronics Co., Ltd. SMA-MG322-Insert-1118 Rev-11
Star mG-S Series Wire Sealing Guide
mG-S322
3Slide to Lock position. 4Put the Pan on the scale.
5Assemble and attach the windshield.
Refer to Assembling the windshield.
6Connect AC adaptor.
Star Micronics America - mG-S Series Scale Support Guide For more details about unit’s setup, usages and specifications, refer to the manual on the link. http://www.star-m.jp/prjump/000106.html
2Take o M3 hexagon screws (opposite side size: 5.5mm) and base frame.
3Take o the screw on the back.
4Attach wire sealing holder to back of scale using the back screws.
Slim head screws
Holder
5Run wire through the 2 holes and secure them to the counter.
1Take o the wind shield.
Your new scale has a lot to offer! This scale is NTEP Certified meaning you can sell the products that you are weighing. There are
a few steps before you can legally use it. Every state has different rules and regulations.
For more information about your state, please refer to
Level the Scale
1Before turning on the scale, place the scale on a stable surface.
Then, adjust the four feet at the corners.
2Make sure the level bubble is in the center as below.
Setup Guides
Operation
Manual
This Manual

Connect to a tablet via Bluetooth Low Energy
Scale names are as below.
(Default)
mG-S322: mG-S322XXYYYY
Select the scale when your
application is in the search function.
For more details, please contact your software company.
XX: The manufacture date
YYYY: The last 4 digits of the serial number
The serial number is on the label at the back.
Power on/off the scale
Self-check
(13 sec)
2 sec
Operation Check
Press the weighing pan lightly to see if the indication changes.
Zero-point Adjustment
This function makes the indicator zero without any loads.
Make sure nothing is on the pan
Note: When the weighing load exceeds +-1.5 % of that capacity, this function cannot be executed.
Change Unit
*The buttons under the display are F1, F2, F3, and F4 from left.
The displayed unit is ashing.
Fix unit Return to the weighing mode.Select UNIT with these buttons.
Weighing a sample with a container (Tare)
This function makes the indicator zero without any loads.
Note: When you want to clear the tare weight, please press “ZERO” button.
Connect to Windows PC
Bluetooth
1. Turn on the scale.
2. Add Bluetooth device on you PC. The scale is in “Devices and
Printers”. e.g. “MG-S1501XXYYYY”
3. Right click on the scale in the “Devices and Printers”, then, go to
“Properties”.
4. You can see “COMn” in “Services” tab.( n means a port number).
5. In your POS application, choose the same COM port when
conguration your scale.
USB
1. Download the scale driver at the link below and install it on your PC.
(http://www.starmicronics.com/support/?printerCode=MG-S_Scale)
2. Connect the scale to PC with USB cable.
3. Turn on the scale.
4. The scale appears in “Devices and Printers” e.g. “STAR MG-1501 (COM4)”
5. In your POS application, choose the same COM port when conguring your scale.
Use of USB bus power
1. Open “Properties” by right clicking on the scale name in “Ports (COM &LPT)”
in “Device Manager”.
2. Check off “Allow the computer to turn off this device to save power” in
“Power management” tab.
Star Micronics America - mG-S Series Scale Support Guide For more details about unit’s setup, usages and specifications, refer to the manual on the link. http://www.star-m.jp/prjump/000106.html
Lock the security switch
1. Turn off the scale and unplug the power cable. If the windshield is attached, remove it.
2. Remove the square sticker at the front bottom of the scale as shown below.
3. Set the securtity switch to Locked position. This switch is at “Unlocked position” as default.
Configure the settings
Congure to the settings you want to use. Refer to the operation manual.
Sealing
Security stickers or a plate should be attached as below.
Verification
A weights and measures ofcial or authorized service agent must perform the verication procedure.
If the state requires a wire sealing, use a lock plate on the back of the
scale as below. Please refer to “Star MG-S Series Wire sealing Guide”.
Sticker
Sticker
Star mG-S Series Calibration Guide
This document explains what must be done to use this scale for any commercial purposes or legally controlled application.
The owners are responsible for making sure the scale meets the requirements of your state, local, or federal weights and
measures ofce. A procedure to place the scale into service also depends on states.
Please contact them for details in advance. You can nd your contact and the link to the weights and measures division of your
state here.
http://www.ncwm.net/resource/state-directors-all
What you need
Calibration weight (OIML F1 Class)
Security sealing items included in the box
Non-conductive thin rod
Operation manual (http://www.star-m.jp/pjump/000106.html)
Leveling the scale
Adjust footers at the bottom corners of the scale.
Refer to the operation manual.
Calibration
Please turn on the scale more than 30 minutes before the calibration and load the calibration weights few times. Follow the
instruction of “Span calibration with external weight” in the operation manual. We recommend using the capacity weight.
mG-S322: 320 g
If you don’t use a weight more than one-half of the capacity, the “UC” is displayed when weighing more than twice heavy
calibration weight because the weighing accuracy is not guaranteed.
Please do this after
unplugging the power cable.
Locked
position
Unlocked
position