Steamist SMS-100 User manual

Floor Model Sauna Heater
Instructions for Installation and Use
Sauna Heater Models: SMS-100, SMS-100-3, SMS-125, SMS-125-3, SMS-145, & SMS-145-3
11/10 Pub. No. 573-B
- 1 -
Sauna heater installation, wiring, operating instructions, trouble-
shooting, maintenance, and warranty.
IMPORTANT: This manual must be left with the owner, manager,
or operator of Sauna after it is used by the electrician!
Purpose of the electric heater:
The Steamist SMS-100 thru SMS-145-3 sauna heaters are
designed for the heating of large saunas to bathing temperature.
It is forbidden to use the heater for any other purposes. Please
read the user's instructions carefully before using the heater.
NOTE: These Instructions for Installation and use are intended
for the owner or the person in charge of the sauna as well as for
the electrician in charge of the electrical installation of the heater.
1. Instructions for Use
1.1 Piling of the Sauna Stones
1.2 Heating of Sauna
1.3 Control Unit of Heater
1.4 Throwing Water on Heated Stones
1.4.1 Sauna Water
1.4.2 Temperature and Humidity of the Sauna Room
1.5 Instructions for Bathing
1.6 Warnings
1.7 Troubleshooting
2. Sauna Room Construction - General Information
3. Instructions For Installation
3.1 Prior to Installation
3.2 Installation of Control Unit and Sensor
3.3 Installation of Heater
3.3.1 Single Phase Heater Wiring and Hookup
(SMS-100, SMS-125, and SMS-145)
3.3.2 Three Phase Heater Wiring and Hookup
(SMS-100-3, SMS-125-3, and SMS-145-3)
3.4 After Installation
3.4.1 Testing of Sauna Heater
3.4.2 Troubleshooting
3.4.3 Overheating Limiter
Maintenance Instructions
Steamist Limited Warranty
Spare Parts
1.1 Piling of the Sauna Stones
The sauna stone for an electric heater should be 2-4" in
diameter. The heater stones should be solid blocks of stone
specially intended for use in the heater. Neither light,
porous ceramic "stones" of the same size nor soft
potstones should be used in the heater, because they
may cause the resistance temperature to rise too high as
a result of which the resistance may be broken.
Stone dust should be washed off before piling the stones.
The stones should be piled into the stone compartment
over the grating, between heating elements (resistances)
so that the stones support each other. The weight of the
stones should not lie on the heating elements.
The stones should not be piled too tightly, so that air can
flow through the heater. See Figure 1. The stones should be
fitted loosely, and not wedged between the heating elements.
Very small stones should not be put into the heater at all.
The stones should completely cover the heating elements.
However, they should not form a high pile on the elements.
The stones disintegrate with use. Therefore, they should
be rearranged at least once a year or even more often if the
sauna is in frequent use. At the same time, any pieces of
stones should be removed from the bottom of the heater, and
disintegrated stones should be replaced with new ones.
The warranty does not cover any faults caused by the use
of stoves not recommended by the factory. Neither does the
warranty cover any faults caused by disintegrated or too
small stones blocking the heater ventilation.
No such objects or devices should be placed inside
the heater stone space or near the heater that could
change the amount or direction of the air flowing though
the heater, thus causing the resistance temperature to
rise too high, which may set the wall surfaces on fire!
Contents
1. Instructions for Use
®

1. Instructions for Use
11/10 Pub. No. 573-B
- 2 -
Instructions for Installation and Use
1.2 Heating of the Sauna
Before switching the heater on always check that there
isn't anything on top of the heater or inside the given
safety distance. See item 1.6 Warnings.
When the heater is switched on for the first time, both the
heater and the stones emit smell. To remove the smell, the
sauna room needs to be efficiently ventilated.
The purpose of the heater is to raise the temperature of the
sauna room and the sauna stones to the required bathing
temperature. If the heater output is suitable for the sauna
room, it will take about an hour for a properly insulated sauna
to reach that temperature. See item 2 "Sauna Room
Construction - General Information." A suitable temperature
for the sauna room is about 149 - 176°F (65 - 80°C).
1.3 Control Unit of Heater
The SMS-100, SMS-125 and SMS-145 model heaters
require a separate control unit to operate the heater. The
control unit should be located outside the sauna room in a dry
place, at an height of approximately 5 ft. The temperature
sensor, by means of which the set temperature is maintained
in the sauna room, must be connected to the control unit. The
temperature sensor and the overheating limiter are located in
the sensor box installed above the heater. The sensor box
should be installed in accordance with the installation
instructions of the control unit model in question.
NOTE:The SMS-100, SMS-125 and SMS-145 model heaters
are controlled with the S170-1 digital sauna control unit. The
SMS-100-3, SMS-125-3 and SMS-145-3 model heaters are
controlled with the S170-3 digital sauna control unit.
Steamist Digital Sauna Control:
●Temperature adjustment range 104–194 ºF
(40–90 °C).
●Pre-setting time adjustment range 0–12 h.
●Lighting control, max. power 100 W, 120 V 1PH
●Fan control, max. power 100 W, 120 V 1PH
●Dimensions: 3.7” x 1.1” x 4.4”
(94 mm x 28 mm x 113 mm)
Power unit:
●Supply voltage
S170-1: 240 V 1PH
S170-3: 208 V 3PH
●Max. load
S170-1: 15 kW/240 V 1PH
S170-3: 14.4 kW/208 V 3PH
●Dimensions: 11.0” x 3.1” x 7.9”
(270 mm x 80 mm x 201 mm)
Sensor:
●Temperature sensor NTC thermistor 22 kΩ/
T=77 ºF (25 ºC)
●Resettable overheating limiter
●Dimensions: 2.0” x 2.9” x 1.1”
(51 mm x 73 mm x 27 mm)
●Weight 175 g with leads, ca 13 ft (4 m)
1.4 Throwing Water on Heated Stones
The air in the sauna room becomes dry when warmed up.
Therefore, it is necessary to throw water on the heated
stones to reach a suitable level of humidity in the sauna.
The humidity of the air in the sauna room is controlled by
the amount of water thrown on the stones. A correct level of
humidity makes the bather’s skin sweat and makes breathing
easy. By throwing water on the stones with a small ladle, the
bather should feel the effect of air humidity on his skin. Both
too high a temperature and air humidity will give an unpleas-
ant feeling.
Staying in the hot sauna for long periods of time
makes the body temperature rise, which may be danger-
ous.
The maximum volume of the ladle is 0.2 litres. The
amount of water thrown on the stones at a time should
not exceed 0.2 l, because if an excessive amount of water
is poured on the stones, only part of it will evaporate and
the rest may splash as boiling hot water on the bathers.
Never throw water on the stones when there are people
near the heater, because hot steam may burn their skin.
1.4.1. Sauna Water
The water to be thrown on the heated stones
should meet the requirements of clean household
water. The factors essentially affecting the quality
of water include the following:
●Humus content (colour, taste, precipitates);
recommended content less than 12 mg/l.
●Iron content (colour, smell, taste, precipitates);
recommended content less than 0.2 mg/l.
●Hardness – the most important substances are
manganese (Mn) and calcium (Ca);
●Recommended content of manganese 0.05 mg/l,
calcium less than 100 mg/l.
Calcareous water leaves a white, sticky layer on the stones
and metal surfaces of the heater. Calcification of the stones
deteriorates the heating properties.
Ferrous water leaves a rusty layer on the surface of the
heater and elements, and causes corrosion.
The use of humus, chlorinated water and seawater is
forbidden.
Only special perfumes designed for sauna water may
be used. Follow the instructions given on the package.
1.4.2. Temperature and Humidity of the Sauna Room
Both thermometers and hygrometers suitable for use in a
sauna are available. As the effect of steam on people varies,
it is impossible to give an exact, universally applicable bathing
temperature or percentage of moisture. The bather’s own
comfort is the best guide.
The sauna room should be equipped with proper ventilation
to guarantee that the air is rich in oxygen and easy to breath.
Bathing in a sauna is considered a refreshing experience
and good for the health. Bathing cleans and warms your body,
relaxes the muscles, soothes and alleviates anxiety. As a
quiet place, the sauna offers the opportunity to meditate.
Figure 1 - Piling of Sauna Stones

2. Sauna Room Construction - General Information
1. Instructions for Use
11/10 Pub. No. 573-B
- 3 -
Instructions for Installation and Use
1.5. Instructions for Bathing
●Begin by washing yourself.
●Stay in the sauna for as long as you feel comfortable.
●According to established sauna conventions, you must
not disturb other bathers by speaking in a loud voice.
●Do not force other bathers from the sauna by throwing
excessive amounts of water on the stones.
●Forget all your troubles and relax.
●Cool your skin down as necessary.
●If you are in good health, you can have a swim if a
swimming place or pool is available.
●Wash yourself properly after bathing. Have a drink of
fresh water or a soft drink to bring your fluid balance
back to normal.
●Rest for a while and let your pulse go back to normal
before dressing.
1.6. Warnings
●Sea air and a humid climate may corrode the metal
surfaces of the heater.
●Keep away from the heater when it is hot. The stones
and outer surface of the heater may burn your skin.
●Do not throw too much water on the stones. The
evaporating water is boiling hot.
●Do not let young, handicapped or ill people bathe in the
sauna on their own.
●Consult your doctor about any health-related limitations
to bathing.
●Parents should keep children away from the hot heater.
●Consult your child welfare clinic about taking little
babies to the sauna.
- age?
- temperature of the sauna?
- time spent in the warm sauna?
●Be very careful when moving in the sauna, as the
platform and floors may be slippery.
●Do not smoke, use alcohol, or exercise in the sauna!
●Do not exceed 30 min. in the sauna at one time, as
excessive exposure can be harmful to health. The
sauna should not be used as an endurance test!
●Persons with poor health should consult their physicians
before using the sauna!
●Do not place any combustible material over the sauna
Heater (towels, bathing suits, wooden bucket or dipper)!
●Use only clean tap water on the stones – do not use
pool or spa water, as chlorine gas can be produced and
the heating elements can be damaged!
●Hyperthermia occurs when the internal temperature of
the body reaches a level several degrees above the
normal body temperature of 98,6 ºF. The symptoms of
hyperthermia include an increase in the internal
temperature of the body, dizziness, lethargy, drowsi-
ness, and fainting.
The effects of hyperthermia include:
A. Failure to perceive heat
B. Failure to recognize the need to exit the room.
C. Unawareness of impending hazard
D. Fetal damage in pregnant women
E. Physical inability to exit the room
F. Unconsciousness
WARNING – the use of alcohol, drugs, or medication is
capable of greatly increasing the risk of fatal hyperthermia.
1.7. Troubleshooting
If the heater does not heat, check the following points:
●The current from the control unit to the heater has been
switched on.
●The desired temperature programmed in the control
panel is higher than the temperature of the sauna.
●The breaker is switched on. Also, breaker should be
correct size.
A. Framing
2” x 4” dry Douglas Fir, 16” o.c.
B. Ceiling height
No higher than 7’0”.
C. Insulation
R11 Fiberglas with foil back in walls and ceiling, foil facing
into room.
D. Drywall
See local codes. Is not required in most residences. See
local codes for commercial. If drywall is used, apply 1” x 2”
nailers so that wall and ceiling boards can be attached to
solid wood.
E. Paneling
Use kiln-dried, clear, T & G softwood such as California
Redwood, Western Red Cedar, Alaska Yellow Cedar, with
moisture content not exceeding 11 %.
F. Benches
Use matching wood of vertical grain with 2” x 2” tops – ½”
spacing – and 2” x 4” facing, fastening from bottom to
prevent burning of bathers.
G. Heater fence
Is necessary for safety and should be constructed of 1” x 2”
or 2” x 2” softwood to match sauna interior. See figures 2-4
for clearances from sauna heater. Fence should attach to
wall and should not be placed higher than top of heater
below rock line.
H. Door
Must open out and should not have a lock. Size – 2’0” x
6’8” with fir rails and double sealed, tempered glass.
I. Flooring
Concrete, ceramic tile, or heavy duty Vinyl with walking
area of removable SuperDek or Duckboard.
J. Ventilation
Should be provided by lower vent close to heater, 4” from
floor, and upper vent on opposite wall (if possible) 6” from
ceiling or as low as 24” from floor. Vents should be
adjustable and should allow air to change 5 times per hour.
Sauna shall be provided with intended ventilation as
required per the local code authorities.
K. Light
Should be a vapor proof, wall-mounted type, with rough-in
box mounted flush with inside paneling. It should mount
6’6” from floor, not directly over sauna heater, and not over
upper benches; light bulb should not exceed 75 watts.
L. Accessories
Bucket, ladle and thermometer are essential. Thermometer
should be placed over the sauna heater, 6” from ceiling, for
correct temperature reading. Other accessories such as
hygrometer, sand timer, brushes, etc. are available.
M. Maintenance instructions
Included at the end of this manual.
N. Warning signs

6"
2 1/2"
1-2"
26"
1"
52"
4"
Note: Control panel and power unit must be installed in a dry
place; away from spa, pool or shower; not outdoors. A
receptacle shall not be installed inside the sauna room.
Load center shall be supplied by
electrical contractor during field
wiring, and shall be Cutler Hammer
model CH4F or equivalent. Load
center can be located in other
serviceable places, as well as
location shown on this diagram.
Load Center
Control Panel
Power Unit
Wire to room light #14 AWG 90°C
Sensor
Fence
Room Light
Seal tight
flex conduit to
connect use 1"
90° connector
6'-5" Min. Height
7'-0" Normal Height
8'-0" Max. Height
3. Instructions for Installation
Figure 2
Furnished with sauna heater. The metal “CAUTION” sign
should be fastened to wall, close to heater, in a visible
place. The metal “WARNING” sign should be fastened
outside, to the sauna room door.
3.1. Prior to Installation
Prior to installing the heater, study the instructions for
installation, as well as checking the following points:
●Is the output and type of the heater suitable for the
sauna room?
The cubic volumes given in table 1 should be followed.
●Are there a sufficient number of high quality sauna
stones?
●Is the supply voltage suitable for the heater?
●The location of the heater fulfils the minimum require-
ments concerning safety distances given in figures 2–6
and table 1.
It is absolutely necessary to ensure that the installation is
carried out according to these values. Neglecting them
can cause a risk of fire.
●Only one electrical heater may be installed in the sauna
room.
●The heater should be installed so that the warning texts
on the cover of the junction box can also be read without
difficulty after the installation.
●SMS heaters have not been approved to be installed in
a recess in the wall or floor.
3.2. Installation of Control Unit and Sensor
Detailed instructions for the installation of both the unit and
the sensor are delivered with the control unit.
3.3. Installation of Heater
The heater may only be connected to the electrical
network in accordance with the current regulations by a
licensed electrician.
The wiring diagrams are included in the control unit’s
installation instruction.
Further instructions concerning exceptional installations
can be obtained from local electrical authorities.
1. Remove heater from carton and place in proper location in
sauna room. Observe proper clearances as per figures
2–6 and table 1. After final hookup, electrical contractor
should secure heater to floor with at least two screws or
bolts.
2. See applicable wiring diagram for heater model (figures
8–9, see control unit manual for detailed instructions how
to connect the heater and the control unit). Heater must be
permanently installed (no pigtails or plugs allowed) and
wiring must be done by a licensed electrician, who must
follow wiring diagram provided and adhere to local codes.
Use proper A.W.G. rated wire size and use copper wire
suitable for 90 °C within sauna walls. Use grounding
terminals provided in sauna heater and control unit to
properly ground the equipment as per NEC and local
codes.
3. Inside the heater box there are two signs. Please place the
metal ”CAUTION” sign on the interior wall of the sauna
room directly above the heater in a visible place. Place the
metal ”WARNING” sign outside, on the door of the sauna
Instructions for Installation and Use
11/10 Pub. No. 573-B
- 4 -

20"
2 1/2"
20"
6"
6"
4"
19"
38"
VENTILATION, MIN. SQ.IN. INLET AND OUTLET
10kW 30 sq.in.
12.5kW and 15kW 45 sq.in.
AIR IN
CONCRETE TILE
FENCE
AIR OUT
6'-5" Min. Height
7'-0" Normal Height
8'-0" Max. Height
Figure 3
6"
MIN.
2 1/2"
MIN.
26"
1"
52"
Figure 4
FENCE
21/2"
21/2"
5" MIN. (10 kW)
6" MIN. (12.5-15 kW)
Figure 5
WOOD
FENCE
HEATER MIN. CLEARANCE FROM
WALL AND FENCE
Figure 5
BENCH
BANC
MIN. 5" (10 kW)
MIN. 6" (12.5-15 kW)
HEATER MIN. CLEARANCE FROM BENCHES
Figure 5
SMS-100-3
SMS-125-3
SMS-145-3
SMS-100
SMS-125
SMS-145
11/10 Pub. No. 573-B
- 5 -
Instructions for Installation and Use
room. ”MAINTENANCE INSTRUCTIONS” are at the end
of this manual.
3.3.1. Single Phase Heater Wiring and Hookup (SMS-100,
SMS-125, SMS-145)
Refer to table 2 for proper wire size and amperage. See
figures 2–6 for required clearances. Use copper wire from
breaker to wall-mounted power unit. Supply cable must have
5 wires including insulated neutral and separate ground.
Use 90 °C copper wire from power unit to room light. Also
use 90 °C copper wire from power unit to sauna heater
(within seal tight flex conduit), and connect to junction box
under heater at back, with 90 °C connector.
Cutler-Hammer model CH4F load center or equivelant
shall be supplied by electrical contractor.
If connection to heater will be made at a later time, bring
flex into sauna room 4–6” from floor, and leave 3’ of flex for
hookup (can be cut to right length later). Before testing

3. Instructions for Installation
11/10 Pub. No. 573-B
- 6 -
Instructions for Installation and Use
heater, fill rock cavity with igneous stones provided with
heater and fasten metal protective grill on top of heater. (See
gen. info concerning washing and placing of stones.)
3.3.2. 3-phase Heater Wiring and Hookup (SMS-100-3,
SMS-125-3, SMS-145-3)
Refer to table 2 for proper wire size and amperage. See
figures 2–6 for required clearances. Use copper wire from
breaker to wall-mounted power unit. Supply cable must have
4 wires including insulated neutral and separate ground.
Use 90 °C copper wire from power unit to room light. Also
use 90 °C copper wire from power unit to sauna heater
(within seal tight flex conduit), and connect to junction box
under heater at back, with 90 °C connector.
If connection to heater will be made at a later time, bring
flex into sauna room 4–6” from floor, and leave 3’ of flex for
hookup (can be cut to right length later). Before testing
heater, fill rock cavity with igneous stones provided with
heater and fasten metal protective grill on top of heater. (See
gen. info concerning washing and placing of stones.)
3.4. After Installation
3.4.1. Testing of Sauna Heater
1. After sauna heater has been properly wired, according to
appropriate wiring diagram and local codes, turn sauna
breaker on in the main breaker panel. (Note: Electrician
must label “Sauna” breaker.)
2. Turn thermostatic (heat) control to on position (this is
located either on your heater or on your remote wall
control. If you have a wall control, the indicator light will
come on to show that the sauna is heating). Set timer to 10
or 15 minutes.
3. Within 5 minutes, you should be able to feel heat from
heater elements when holding your hand over heater.
4. If the sauna does not heat, refer to troubleshooting
information.
5. It is normal for smoke to appear during the first heating, as
protective element coating needs to burn off. Turn sauna
on for 1 hour before using the first time, to eliminate
smoking.
3.4.2. Troubleshooting
A. If the sauna heater does not operate after initial
installation and wiring:
1. Make sure that a neutral wire has been included. This is
necessary for all heaters except model with built-in
control).
2. Check circuit breaker in contactor to be sure that it has not
been shorted out.
3. Make sure that the current from the control unit to the
heater has been switched on.
4. Check that the desired temperature programmed in the
control panel is higher than the temperature of the sauna.
B. If the sauna has been in operation, but the heater
ceases to operate:
1. Check breaker to make sure it is on.
2. Check that there is on time left in the control panel.
3. Check overheat limiter reset button in heater (reset is
under the heater) to see if it has been released.
4. Call your electrician or service person for further help.
NOTE: A GROUND FAULT INTERRUPTER (GFI) should not
be installed in and does not belong in a sauna. If used, the
breaker will trip, and damage could result.
C. If the sauna heater operates, but the sauna room does
not come up to sauna temperature (149–176 ºF)
1. You must allow at least 30 minutes for sauna heat-up time.
2. Is the sauna thermometer located 6” from ceiling, and is it
above or close to the sauna heater? (This is proper
location for sauna temperature reading.) Thermometer
readings vary with room heights and location. Eg.180 ºF
above sauna heater = 165 on opposite wall = 140 on upper
bench level = 120 on lower bench level = 100 at floor level.
Table 1
Model Heater kW Minimum
Ceiling
Height
Minimum
Floor Area
in Square
Feet
Maximum
Floor Area
in Square
Feet
Sauna Room
Minimum
Cubic Feet
Sauna Room
Maximum
Cubic Feet
Minimum
Spacing From
Adjacent
Surfaces
SMS-100
SMS-100-3
SMS-125
SMS-125-3
SMS-145
SMS-145-3
10 kW
12.5 kW
15 kW
6'-6"
6'-6"
6'-6"
60
78
97
94
114
146
390
500
630
600
750
1000
5 inches
6 inches
6 inches
Model
SMS-100-3
SMS-125-3
SMS-145-3
Watts
9,800
12,300
14,400
Amps
27.3
34.1
40.0
Voltage
208
208
208
Phase
3
3
3
Breaker to Power Unit
1@35A - #8 AWG copper 90°C
1@45A - #6 AWG copper 90°C
1@50A - #6 AWG copper 90°C
Power Unit to Heater
#8 AWG copper 90°C
#6 AWG copper 90°C
#6 AWG copper 90°C
Control
S170-3
S170-3
S170-3
S170-1
S170-1
S170-1
SMS-100
SMS-125
SMS-145
10,000
12,600
14,800
41.7
52.5
61.7
240
240
240
1
1
1
Breaker to Load Center
1@60A - #4 AWG copper 90°C
1@70A - #4 AWG copper 90°C
1@80A - #3 AWG copper 90°C
Load Center to Power Unit
2@35A - #8 AWG copper 90°C
2@35A - #8 AWG copper 90°C
2@40A - #8 AWG copper 90°C
Power Unit to Heater
#8 AWG copper 90°C
#8 AWG copper 90°C
#8 AWG copper 90°C
Table 2
Note: neutral wire required

Instructions for Installation and Use
3. Instructions for Installation
Figure 8 - SMS-100, SMS-125, and SMS-145 Figure 9 - SMS-100-3, SMS-125-3, and SMS-145-3
L1 L1 L2 L2 A1 A2GND
4-3-
2-
1-
4-3-
A2
2-
1-
A1
165432
4 pole contactor
Overheating limiter
Sensor
Overheating limiter
Sensor
165432
4-3-
A2
2-
1-
4-3-
2-
1-
A1
4 pole contactor
L1 L2 L3 A1 A2GND
Overheating limiter
Sensor
Overheating limiter
Sensor
Electrical connections of 240V / 1-Phase heaters Electrical connections of 208V / 3-Phase heaters
Maintenance Instructions
11/10 Pub. No. 573-B
- 7 -
3. Check for proper wire size, amp size, and proper wiring
(according to diagrams and information) also necessary
copper wiring.
4. Check the placement of stones to make sure they are
loosely spaced around elements, to insure good air flow.
Stones packed too tightly will restrict air flow and reduce
heating capacity.
5. Check for heat loss (around or under door, around ceiling
light or fan – we do not recommend ceiling light and a fan
does not belong in the sauna.
6. Is the room properly insulated?
7. Is the ceiling higher than 7’?
8. After checking all the above, remove rocks and check the
heating elements for holes or burned areas. (Only if heater
has been in use for some time.)
CAUTION: Electrician or service person!
1. BEFORE SERVICING HEATER, CONTROL, OR CON-
TACTOR, TURN POWER OFFAT BREAKER!
2. Open junction box to make sure wires are tightly secured
with no loose connections. Heater wire and all connecting
wires should be copper.
3. Check for burned spots or short in wiring of timer or
thermostat.
Sauna heater's warranty on parts are void if the installer or
electrician fails to follow necessary wiring information
provided or fails to follow code for proper wire size, amper-
age, etc.
3.4.3. Overheating Limiter
Each heater is equipped with an overheating limiter which
is a safety device. If an abnormal heating condition should
occur, the heater will automatically shut off, and it will not
come on again until it cools.
To reset the overheating limiter, locate the reset button
(bottom front on wall models, behind junction box at back
bottom of floor-mounted heaters) and push upward until
contactor kicks in. If the reset button continues to trip, contact
a qualified service person. Be sure that a GFI has not been
installed.
1. Use only clean water on sauna stones. DO NOT use spa
or pool water as it will destroy your heater.
2. Clean water should always be used in sauna buckets and
water should be dumped out after every use. Scour
buckets and dippers occasionally when film collects from
usage. Use plastic bucket liner in bucket to prevent water
leakage.
3. Scrub benches with a soft brush, using soap and water or
a mild disinfectant, when needed — about once a week in
commercial saunas, or depending upon sauna usage. For
sanitation, each bather should sit or lie on a towel (this will
prolong bench life).
4. Remove sauna mat and wash waterproof floor with
disinfectant (e.g. Pine Sol) about once a week or as often
as needed. Hose off Super Dek to clean.
5. To maintain beautiful appearance of Sauna heater, remove
water stains by wiping with a damp cloth occasionally.
6. Our heaters require no special maintenance when properly
installed by a qualified electrical contractor. After 1–2 years
of usage, the rocks may need replacing if they have
crumbled or powdered (depending upon sauna usage).
7. We strongly recommend a floor that can be easily cleaned
(concrete, ceramic tile, or a poured type of flooring). When
this is provided, the sauna can be easily cleaned and kept
in a sanitary condition with little effort. A carpet is NOT
recommended for a sauna! A carpet becomes a perfect
breeding ground for bacteria in the moist conditions of a

1123456
Sauna Heater models:
SMS-100, SMS-125, SMS-145
SMS-100-3, SMS-SM 2
3
4
56
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27 28
1. Stone Compartment
2. Stone Holder
3. Base Plate
4. Top Part
5. Casing Side L/R
6. Casing Front/Rear
7. Electrical Casing
8. Electrical Casing R
9. Electrical Casing L
10. Radiation Shield
11. Terminal Block Bracket
12. Electrical Casing Cover
13. Wiring Diagram
14. Rating Plate Sticker
15. Adjustment Leg
17. Connection Cable Holder
18. Heating Element Set
19. Terminal Block Sticker
20. Floor Mounting Plate
21. Protective Grill
22. Overheating Limiter / Sensor
Bracket
23. Overheating Limiter / Switch
24. Contactor Bracket
25. 4-Pole Contactor
26. Grounding Terminal
SMS-100
1,2,3,4,5,6
SMS-125
1,3,5
2,4,6
SMS-145
1,2,3,4,5,6
SMS-100-3
1,2,3,4,5,6
SMS-125-3
1,2,3,4,5,6
SMS-145-3
1,2,3,4,5,6
10kW
1640 W/240V
12.5kW
1640 W/240V
2350 W/240V
15kW
2350 W/240V
10kW
1640 W/208V
12.5kW
2050 W/208V
15kW
2460 W/208V
Instructions for Installation and Use
Spare Parts
Steamist Limited Warranty
Maintenance Instructions
11/10 Pub. No. 573-B
- 8 -
Residential Applications
Steamist will replace any defective components in their sauna
heaters, contactors, controls, used in residential applications, for the
period of 5 years from the original purchase date. This limited
warranty covers faults in manufacture and material only, and includes
the exchange of new parts supplied by the manufacturer or the
manufacturer’s agent, after the defective parts are returned to
Steamist. The replacement of parts under warranty does not extend
the warranty period beyond the original five year period. In addition,
Steamist will perform the required labor to repair or install the
component, at the factory, for the period of one year from the original
purchase date. All costs for removal and reinstallation of the
component(s) on the job site, shipment to the factory and shipment
back to the job site will be the responsibility of the owner of the
equipment.
Commercial Applications
Steamist will replace any defective components in their sauna
heaters, contactors, controls used in commercial applications, for the
period of one year from the original purchase date.
This limited warranty covers faults in manufacture and material
only, and includes the exchange of new parts supplied by the
manufacturer or the manufacturer’s agent, after the defective parts
are returned to Steamist. The replacement of parts under warranty
does not extend the warranty period beyond the original one year
period. In addition, Steamist will perform the required labor to repair
or install the component, at the factory, for the period of one year from
the original, purchase date. All costs for removal and reinstallation of
the component(s) on the job site, shipment to the factory and shipping
back to the job site will be the responsibility of the owner of the
equipment. This limited warranty does not cover damage to the
heater caused by normal wear and tear, damages caused by
improper installation, improper use and care or alterations made to
the sauna product.
This limited warranty is void if the heater is used improperly.
Chemically treated water, such as spa or pool water should not be
poured over the sauna stones. The sauna room must be heated for a
minimum of 30 minutes prior to the application of water to the sauna
stones. The limited warranty is void if a shower or faucet has been
installed in the sauna. Damages resulting from the misuse of the
heater will not be covered in the warranty.
This limited warranty is void if the installation and wiring is not
performed by a certified electrician or authorized and qualified service
representative.
The limited warranty applies only to the original purchaser and
installation of the product.
A return authorization number assigned by Steamist is required
prior to returning any product for repair. Components returned without
a return authorization number may not be repaired or replaced.
East Coast Office: 25 E. Union Ave., East Rutherford, NJ 07073 • Tel: 800-577-6478 • Fax: 201-933-0746
West Coast Office: Tel: 800-355-6478 • Fax: 661-940-1617
®
sauna; and a carpet promotes the spread of foot diseases
such as athlete’s foot.
8. In new construction, a floor drain should also be provided,
especially in commercial saunas for sanitary cleaning and
maintenance.
9. Seal wood around glass in door—inside and outside-
with Thompson’s Water Seal to prevent warpage.
10. When sauna wood becomes stained from perspiration, the
wood may be lightly sanded with fine sandpaper to restore
beautiful appearance. We do not recommend stains or
sealers as toxic vapors may appear when heated.
11. The sauna room will heat faster if the higher vent is kept in
a closed position when heating. The lower vent may
always be kept in an open position.
12. Required warning signs should be posted according to the
instructions.
This manual suits for next models
5
Table of contents
Other Steamist Heater manuals
Popular Heater manuals by other brands

MO-EL
MO-EL SHARKLITE 718 Use and maintenance

MrHeater
MrHeater 400FAVT Operating instructions and owner's manual

Silvercrest
Silvercrest SKHD 1800 A1 operating instructions

Procom
Procom MGT10BF OWNER'S OPERATION AND INSTALLATION MANUAL

CO/Tech
CO/Tech ZHQ1580-WM-RM-UK Instructions for use

ENERCORP
ENERCORP MR. HEATER MH170FAVT Operating instructions and owner's manual

Quality Craft
Quality Craft MW914T-24BK instruction manual

Comfort Zone
Comfort Zone CZ2022O owner's manual

MrHeater
MrHeater MH170QFAVT Operating instructions and owner's manual

Procom
Procom WZN18TLA OWNER'S OPERATION AND INSTALLATION MANUAL

Mark
Mark 24 User instructions

MO-EL
MO-EL 79304 Use and maintenance