STEINEL PROFESSIONAL 4007841009595 User manual

Flexibler Heißluftständer
Flexible hot air tool arm
Vakuumfuß
Suction foot Anwendung
Application
000000000 07/2013 Technische Änderungen vorbehalten.
RUS CN BG LV LT EST HR SLO RO PL SK CZ H TR GR N FIN DK S P E I NL F GB D
Magnetfuß
Magnetic foot
STL-5750-15_BDAL_Heißluftständer_A5.indd 1 10.07.15 13:24
DEGBFRNLITESPTSEDKFINOGRTRHUCZSKPLROSIHREELTLVRUBGCN
Hilltop Products Ltd - www.hilltop-products.co.uk - Tel: +44 1942 723101 - Email: sales@hilltop-
products.co.uk
Hilltop Products Ltd - www.hilltop-products.co.uk - Tel: +44 1942 723101 - Email: [email protected]

- 2 - - 3 -
3.2
4.1
5x-10x
!
4.2
1.
1.
2.
4.3
3
4.4
4.5
lik
c
c
4.6
...
C
H
D
E
F
G
x
2.1
2.2
2.3
3.1
A
B

- 8 -
FR
5. The suction cup is detached from the surface
by pushing it to the side. (Fig. 4.2)
Magnetic foot (C)
• Place the magnetic foot (C) on a ferromagnetic
contact surface. (Fig. 4.3)
• The hot air tool arm is detached by pulling it
from the contact surface.
Hot air tool
•
•
•
•
Correctly align the guard sleeve on the hot air
tool. (Fig. 4.4)
Insert the hot air tool vertically into the fixing
ring. (Fig. 4.5)
The hot air tool is properly fitted when it can
be heard to “CLICK” into place. (Fig. 4.5)
Do not insert the hot air tool horizontally.
If inserted horizontally, the hot air tool is not
fixed in place properly. (Fig. 4.6)
5. Maintenance / care
Make sure that the suction cup’s air filter (H) is
properly attached. If it is not, discontinue use and
attach the air filter (H) / pump properly. Check suc-
tion and contact surface for dirt and damage.
Cleaning the air filter (H)
– Remove the air filter (H) from the suction pad.
– Clean the suction pad with soapy water, glass
cleaner or alcohol. Make sure that the pump
does not become soiled by liquids. To ensure
this, hold the suction cup (G) with the suction
pad facing down or cover the suction hole’s filter
aperture.
– Remove all residue from the suction pad.
– Dry the suction cup (G) and fit the air filter (H) on
the suction pad.
Storage
• Clean, dry place out of direct sunlight.
• Protect suction foot (D) / magnetic foot (C) from
damage.
6. Disposal
Electrical and electronic equipment, accessories
and packaging must be recycled in an environmen-
tally compatible manner.
Do not dispose of electrical and electronic
equipment as domestic waste.
EU countries only:
Under the current European Directive on Waste
Electrical and Electronic Equipment and its imple-
mentation in national law, electrical and electronic
equipment no longer suitable for use must be
collected separately and recycled in an environ-
mentally compatible manner.
7. Manufacturer’s Warranty
This STEINEL product has been manufactured with
utmost care, tested for proper operation and safety
and then subjected to random sample inspection.
STEINEL guarantees that it is in perfect condition
and proper working order. The warranty period is
12 months and starts on the date of sale to the
consumer. We will remedy all defects caused by
material flaws or manufacturing faults. The warranty
will be met by repair or replacement of defective
parts at our own discretion. This warranty does not
cover damage to wearing parts, damage or defects
caused by improper treatment or maintenance nor
does it cover breakage as a result of the product
being dropped. Further consequential damage to
other objects shall be excluded. Claims under war-
ranty shall only be accepted if the product is sent
fully assembled and well-packed complete with
sales slip or invoice (date of purchase and dealer’s
stamp) to the appropriate Service Centre or hand-
ed in to the dealer within the first 6 months.
Repair service:
If defects occur outside the warranty period or are
not covered by warranty, please ask your nearest
Service Centre about repair options.
MANUFACTURER'S
1
3
5YEAR
GB
WARRANTY
MANUFACTURER'S
YEAR
WARRANTY
MANUFACTURER'S
YEAR
WARRANTY
7 --
GB
1. About this document
Please read carefully and keep in a safe place.
– Under copyright. Reproduction either in whole or
in part only with our consent.
– Subject to change in the interest of technical
progress.
Symbols
!
...
Hazard warning!
Reference to other information in the
document.
2. General safety precautions
Failure to observe warnings may result in personal
injury or damage to property.
Magnetic and suction foot
It is important to follow the safety precautions given
in the operating instructions of the hot air tool being
used.
• Allow sufficient distance between hot air tool and • Do not install the hot air tool arm if it is damaged.
persons or surfaces. (Fig. 2.1 - 2.3)
• Do not leave the hot air tool arm unattended
when in use with the hot air tool.
Suction foot
• Do not use on soft, convex or light-coloured
contact surfaces.
• Do not attach the suction pad to contact surfac-
es which could damage the sealing edge.
• Ensure proper suction (e.g. by making sure the
contact surface is not dirty, cut or scratched, not
attaching to porous materials and not applying
pressure to the suction cup’s sealing edge). This
can cause the suction cup to slip or become
detached.
• Do not use the suction cup if the red safety line
(Fig. 4.1) is visible. If the red safety line keeps
reappearing, discontinue use and re-fix the
suction cup.
➔5. Maintenance / care
• The suction foot’s plunger (F) must be easy to
reach when the suction cup is being attached.
• Do not touch the release mechanism during use.
• Do not use solvents, petrol or other chemicals to
clean the suction cup on the suction foot.
3. Hot air tool arm
Proper use
– Fixing the STEINEL hot air tool on horizontal
surfaces.
– The hot air tool arm can support a maximum
weight of 1 kg and must only be used with
STEINEL hot air tools HL 1820 E, HL 1920 E,
HL 2020 E and HG 2320 E.
Types (Fig. 3.1)
– Magnetic foot (EAN 4007841009595)
– Suction foot (EAN 4007841009601)
Tool overview (Fig. 3.2)
A Fixing ring
B Flexible arm
C Magnetic foot
D Suction foot
E Safety line
F Plunger
G Suction cup
H Air filter
4. Installing / removing
• Check all components for damage.
Magnetic and suction foot contact surfaces
Attach the hot air tool arm to horizontal, non-
vibrating, dry and clean surfaces that are as
smooth as possible.
Suction foot contact surfaces
Moisture or soiling as well as temperatures below
-18°C and over 49°C (0°F to 120°F) can reduce
the suction cup’s resistance to slipping. The red
safety line indicator (E) may not be reliable at alti-
tudes above 1524 m (5000 ft).
➔5. Maintenance / care
Suction foot
1. Clean the contact surface and, if necessary,
the suction cup (G).
2. Pump the plunger (F) until the suction cup (G)
is firmly attached. (Fig. 4.1)
3. The suction cup (G) is ready for use when the
red safety line (E) can no longer be seen.
(Fig. 4.1)
4. Re-pump the plunger (F) a few times if the red
safety line (E) becomes visible during use.
This manual suits for next models