The HEPAPro AS800 is a compact, portable HEPA Air Scrubber for abatement, resto-
ration, and construction projects. It is commercial, yet lightweight machine that is
easy to carry, transport and store. The unit has a 22”x 24” footprint, stands only 14”
tall and weighs less than 35 lbs.
HEPAPro AS800 oers variable airow, up to 800 CFM, that can be directed both
vertically or horizontally. It accepts a 16”inlet ex duct and a 10”lay at outlet duct.
The unit operates at less than two amps of power. It is capable of providing 4 air
changes per hour (the recommended minimum) in a 7500 cubic foot room (more
than a 30’ x 30’x 8’).
This HEPA air scrubber oers a 2-stage lter design including a tested and certied
HEPA lter and pleated pre-lter. An optional carbon/potassium permanganate
lter is available to absorb a wide range of odors and gases.
Warning To Avoid Electric Shock
• Donotexposetostandingwaterorrain.
• ConnecttoGFCIoutlet.
• Donotuseanextensioncord.
• Unplugfanbeforeservicingorchanginglters.
• Donotblockairintakeoroutlet.Allowminimumof12-inchesofdistancebetweenobstructions.
• Indooruseonly.
• Donotuseasstoolorbench.
• Donotoperatewithdamagedcordorplug.
Electrical Requirements
HEPAProAS800shouldbepluggedintoagrounded15ampcircuit.Unitdrawsabout2ampswithcleanltersandno
ducting.Theampdrawwilldecreaseslightlywithaddedductingandastheltersloadwithparticulate.Duetothepres-
enceofGFCIreceptacle,theHEPAProAS800mustbepluggeddirectlyintoawalloutlet.Noextensioncordsshouldbe
used.

Air Ducting
If area to be ltered is dicult to access, congested or the air scrubber cannot be located within, air can be ducted to the
unit’s inlet. A round 16” diameter exible duct can be attached to the unit inlet. It connects by placing the wire in the
ductovertheductcollarlipatonelocationandworkingoveritoverthelipgradually.
Outlet Ducting
A detachable trapezoid shaped exhaust ring is supplied that will allow 10” round lay-at plastic duct to be attached to
the exhaust outlet. To attach ducting to the collar, remove the ring from the unit by pressing release tab at the top of the
grill. Put the plastic duct end through the inside of the ring. Roll the duct end outward so that it over-laps the outside of
thering.Cliptheringbackontotheexhaustgrill.
Negative Air Ducting
HEPAPro AS800 can be used to lter and exhaust air from an enclosed containment area. When exhausting air outside
the containment area, the air inside the containment area must be under slight negative pressure. This will help prevent
airborne particles from leaving the containment area, because negative pressure will draw air in through openings in
the space’s exterior surfaces.
Ducting
Power/Speed Control
The power/speed switch is located on the control panel. It powers the motor and impeller fan. Occasionally the impeller fan may
not start on the low speed setting. If this occurs, rotate the speed control to high speed until the impeller fan starts, then adjust it
to a lower speed.
Resettable Circuit Breaker:
The12AMPthermal,resettablecircuitbreakerprotectstheunitanddevicesconnectedtoitsduplexGFCIoutlet.Thecircuitbreak-
erisdesignedtosensethetotalcurrentdrawthroughthecircuit.Thecircuitbreaker“trips”whenmorethan12ampsofelectrical
currentaredrawnthroughthedevice’spowercord.Shouldanoverloadconditionoccur,theon-boardcircuitbreakerpreventsa
triptoaremotepowerjunctionbox.IMPORTANT:TotalamperageoftheHEPAProAS800,plusalldevicespluggedintotherecep-
taclemustnotexceed12amps.Thecircuitbreakerwillnotallowforloadsinexcessof12amps.
GFCI Protection and the On-Board Outlet:
ThestandardACvoltageoutletwithGFCI(GroundFaultCircuitInterrupter)protectstheoperatorinwetapplications.GFCIdevices
tripwhenafaulttoelectrical“ground”issensed.ItisrecommendedtochecktheGFCIprotectionpriortooperation.Tocheck,
pushthe“TEST”buttonlocatedontheGFCIduplexoutlet.Ifoperatingproperlythe“RESET”buttonontheGFCIoutletwillpop
out.AtrippedGFCIisindicatedbyasmallLED.Thedevicecanonlybe“RESET”whentheunitisconnectedtoawalloutletprovid-
ing standard voltage. This duplex AC outlet allows the inter-connection of other AC powered devices. The sum total amperage of
all devices plugged into the receptacle must not exceed 10 amps.

Air Filters
The HEPAPro AS800 is equipped with two lters that progressively lter out smaller particles. An optional activated carbon/potas-
siumpermanganateltercanbealsoadded.Theseltersmustbecheckedregularly.Operatingtheunitwithdirtylterswillreduce
the airow, and possibly cause harm to the unit. The unit can be run indenitely with dirty lters. The two standard lters used are
listedbelow(asinstalledintheunitfromtoptobottom):A.25to30%ecient(perASHRAE52.1-1992),MERV-7,pleatedfabric
pre-lter.
B.99.97%@.3micronTestedandCertiedHEPAlter.
Filter Replacement
Warranty
Whenamber“lterchangelight”illuminates,itistimetoreplaceoneorbothl-
ters. Remove all ducting and run the air scrubber on high speed. If the lter light
remains lit; replace the pre-lter and run on high again. If the light remains illumi-
nated, it is time to replace the HEPA lter.
The life of the optional Activated Carbon/Potassium Permanganate Filters depend
on the hours used and the level of contaminants recovered. The activated carbon
removes the heavier volatile organics while the potassium permanganate removes
lowermolecularweightcontaminantssuchassmokeodorspresentafterredam-
age. An advantage of the blended media versus activated carbon only is that part
ofthe blendchangescolorasit loadsup withcontaminants.Itstarts outblack,
thenturnspink,thenbrown,andnallywhite.Itisbestchangedwhenitpasses
the brown stage and begins to turn white. It has lost most of its eectiveness at
that point.
HEPAPro AS800 is warrantied for one year and includes the housing, motor, fan and other electrical components. The power cord is
not covered by warranty. If you wish to le a warranty claim, please contact Sterling customer service at 844.822.7787.

SterlingNorthAmericaLLCoersalimitedwarrantytotheoriginalpurchaserofthisproduct(the“Fan”)againstany
defectinmaterialsandworkmanshipasfollows:Fortherstyearfromthedateofpurchase,Sterlingatitsoption,will
replace or repair Fan without charge to the customer. Any repair or replacement of the Fan will be warranted only for
thebalanceoftheoriginalwarrantyperiodorninety(90)days,whicheverisgreater.Thefollowingwillvoidand/orare
notcoveredunderthislimitedwarranty:a)damagecausedbyimproperuse;b)operationoftheFanforanyreasonnot
authorized by Sterling; c) cosmetic damage or any damage caused by misuse, improper maintenance, connection to
impropervoltagesupply,accidents,actsofGod,abuse,negligence,damagecausedduringshipping,modicationsor
attempted repair by anyone other than Sterling; or d) alteration or removal of factory-applied serial number.
TOOBTAINWARRANTYSERVICE:Inordertoobtainwarrantyservice,thepurchasermustreturntheFaninsuitablepack-
aging,postageprepaid,toSterlingNorthAmericaat1633West134thStreet,Gardena,CA90249-2013,andinclude:(i))
proof of retail purchase; (ii) the date of the failure; and (iii) a description of the failure. All shipping expenses to Sterling
are the owner’s responsibility.
The obligations of Sterling herein are granted in lieu of all other warranties, expressed or implied, including, but not
limited to, the warranties of merchantability of tness for a particular purpose. The remedy provided in this warranty is
exclusive and is granted in lieu of all other remedies. Some states do not allow limitations on how long an implied war-
ranty lasts, so the above limitation may not apply to you.
In no event will Sterling be liable for loss of use of the product, loss of prots, direct damages, indirect damages, conse-
quential damages, and/or incidental damages by reason of injury to any person, due to any defect or the malfunction of
Fan or any part(s) thereof, or for any other reason. Some states do not allow the exclusion or limitation of incidental or
consequential damages so the above limitation or exclusion may not apply to you.
This warranty gives you specic, legal rights, and you may also have rights, which vary from state to state. Purchaser’s
acceptance of the Fan and use thereof constitutes acceptance of these terms.
Warrantyreturnaddress:SterlingNorthAmerica,1633West134thStreet,Gardena,CA90249-2013
Limited Warranty
Cut here and return with copy of receipt within 10 days of purchase
To register warranty, please ll out card completely and mail within 10 days of purchase with a copy of original receipt
to:SterlingNorthAmerica,7545IrvineCenterDrive,Suite200,Irvine,CA92618
Name: Email:
Phone:() Unit: POBox:
StreetAddress: State: Zip:
City: Serial#:
Model#: PurchaseDate:
7545IrvineCenterDr.,Ste.200•Irvine,CA92618
TollFree:844VACSRUSor844-822-7787•Fax:949-623-8305
SterlingNA.com
Table of contents
Popular Air Cleaner manuals by other brands

Maestro
Maestro CF-8426A user guide

Wen
Wen 3416T instruction manual

GE
GE AFHC21AM Dimensions and installation information

BeaconMedaes
BeaconMedaes HTM Instruction book

Aztech
Aztech MT402 user manual

Flanders
Flanders Semi Rigid Figh Dust Holding C apacity Extended Surface Bag Filter Pak... Specification sheet