STRIDE SE-MC2U-ST User manual

1
w w w . a u t o m a t i o n d i r e c t . c o m
1 - 8 0 0 - 6 3 3 - 0 4 0 5
STRIDE™INDUSTRIAL UNMANAGED ETHERNET
MEDIA CONVERTERS – DATA SHEET
3505 HUTCHINSON ROAD
CUMMING, GA 30040-5860, USA
Desc iption:
STRIDE SlimLine Industrial Unmanaged Ethernet copper to Fiber
Converter with one 10/100BaseT auto-detecting, auto-crossover and
auto-polarity J45 Ethernet Port and one 100BaseFX Fiber Optic Port
(multimode fiber connector for links up to 4km, ST or SC type
connector depending on model). edundant power inputs with surge
and spike protection. DIN rail mounting. Supports store & forward
wire speed switching and full-duplex with flow control. UL, CSA
(CUL), & CE
NNOOEE::DIMENSIONS, INS ALLA ION AND WIRING INFORMA ION IS
SHOWN ON HE BACK OF HIS DA A SHEE .
SE-MC2U-ST
Copper RJ45 ort: (10/100BaseT)
10/100BaseT ports Shielded RJ45
Protocols supporte All standard EEE 802.3
Ethernet compliancy EEE 802.3, 802.3u, 802.3x
Auto-crossover Yes, allows you to use straight-through or crossover wired cables
Auto-sensing operation Yes, Full and half duplex
Auto-negotiating Yes, 10BaseT and 100BaseT
Auto-polarity Yes, on the TD and RD pair
Flow control Automatic
Ethernet isolation 1500 VRMS 1 minute
Plug an play Yes
Cable requirements Twisted pair (Cat. 5 or better) (shielded recommended)
Max. cable istance 100 meters
Fiber ort: (100BaseFX multimode)
100BaseFX ports 1
Fiber port mo e Multimode (mm)
Fiber port connector ST - model SE-MC2U-ST
SC - model SE-MC2U-SC
Optimal fiber cable 50/125 or 62.5/125 µm
Center wavelength 1300 nm
Multimo e
Links up to 4 km typ.; 1300 nm; use with 50 or 62.5/125 um fiber
> Transmitter power (dB): -21 min, -17 typ, -14 max
> Receiver sensitivity (dB): -34 typ, -31 max
Nominal max. istance
(full uplex) 4 km
Half an full uplex Full duplex
Ethernet compliance 100BaseFX
Eye safety (laser) EC 60825-1, Class 1; FDA 21 CFR 1040.10 and 1040.11
General Specifications
Ethernet switch type 2 ports
Operating mo e Store and forward wire speed switching, non-blocking
Devices supporte All EEE 802.3 compliant devices are supported
Stan ar s EEE 802.3, 802.3u, 802.3x
MAC a resses 1024 addresses
Memory ban wi th 3.2 Gbps
Latency for
10 Mbps ports 16 us + frame time (typical)
Latency for
100 Mbps ports 5 us + frame time (typical)
Power input Redundant nput Terminals
Input power
(typical with all ports
active at 100 Mbps)
2.0 W
Input voltage 10-30 VDC (continuous) - Class 2 Power Supply
Reverse power protection Yes
Transient protection 15,000 watts peak
Spike protection 5,000 watts (10x for 10 uS)
Ethernet isolation 1500 VRMS 1 minute
Operating temperature range -10 to +60 °C (+14 to +140 °F),
cold startup at -10 °C (+14 °F)
Storage temperature range -40 to +85 °C (-40 to +185 °F)
Humi ity
(non-con ensing) 5 to 95% RH
Environmental Air No corrosive gasses permitted
Vibration, shock & freefall EC68-2-6, -27, -32
Agency Approvals
UL/cUL 508, CSA C22 per EN61010-1,
UL/cUL 1604 (Class 1, Div. 2, Groups A, B, C, D),
CSA C 22.2/213 9 per EN50021/EN60079-15
(Zone 2, Category 3), CE (ATEX)
EMI emissions FCC part 15, CES-003, EN55022
EMC immunity EC61326-1
Hazar ous locations UL1604, CSA C22.2/213 (Class , Div.2) (file #E200031);
EN50021/EN60079-15 (Zone2)
RoHS an WEEE RoHS (Pb free) and WEEE compliant
Packaging an protection UL94VO Lexan, P30
Dimensions (L x W x H) See mechanical diagrams for details
Weight 4 oz (0.11 kg)
Safety Standa ds:
UL
CUS
R
Electrical Safety European
Directives US Emissions
WEEE Compliant RoHS Compliant
RoHS
NNOOEE::FOR ADDI ONAL PRODUC DE AILS, A USER MANUAL,
SE-USER-M, IS AVAILABLE AS A DOWNLAODABLE PDF FILE FROM HE
ONLINE DOCUMEN A ION AREA OF HE AAUUOOMMAAIIOONNDDIIRREECCWEBSI E.
SE-MC2U-SC

1
2
A
B
A
B
C
DIN rail mounting steps:
1. Hook top back of unit over the DIN rai .
2. Push bottom back onto the DIN rai unti it snaps into p ace.
DIN rail removal steps:
A. Insert screwdriver into DIN c ip and pry unti it re eases from
the DIN rai .
B. Unhook top of unit from DIN rai .
Installation – DIN Rail Mounting:
The converter can be snapped onto a standard 35 mm x 7.5 mm height
DIN rail (Standard: CENELEC EN50022) and can be mounted either
vertically or horizontally.
2
w w w . a u t o m a t i o n d i r e c t . c o m
1 - 8 0 0 - 6 3 3 - 0 4 0 5
Copyright 2014, Automationdirect.com Incorporated/All Rights Reserved Worldwide
P2 P1
One DC Supply
+–
Single DC Power Redundant DC Power
Chassis
GND
(panel)
P2 P1
+–+–Chassis
GND
(panel)
Dual DC Supplies
Powe Wi ing:
3.96
[100.6]
1.00
[25.4]
Units: inches [mm]
Removable
Screw Block,
Phoenix
p/n 1757035
Media Converters – SE-MC2U-ST and SE-MC2U-SC
Dia. 0.15 [3.8]
Use for direct
panel mounting
to a flat surface.
3.26
[82.8] 0.06
[1.5]
0.40
[10.2] Snaps to standard
35 mm x 7.5 mm height
DIN rail (EN50022)
4.35
[110.5]
1.98
[50.3]
1.98
[50.3]
1.01
[25.7]
1.01
[25.7]
Dimensions:
The converter can be powered from the same DC source that is used to
power your other devices. To maintain the UL508 listing, this must be
a Class 2 power supply. A DC voltage in the range of 10 to 30 VDC
needs to be applied between the P1 (plus) terminal and the Minus
terminal as shown below. The chassis screw terminal should be tied to
panel or chassis ground. To reduce down time resulting from power loss,
the converter can be powered redundantly with a second power supply
as shown below.
A recommended DC power supply is AutomationDirect.com Part
number PSC-24-015.
Communications Po ts Wi ing:
The converter provides connections to standard Ethernet devices such
as PLCs, Ethernet I/O, industrial computers and much more. Use
data-quality (not voice-quality) twisted pair cable rated category 5 (or
better) with standard J45 connectors. Straight-through or crossover
J45 cable can be used for all devices the converter is connected to as all
the ports are capable of auto-mdi/mdix-crossover detection.
NNOOEE::HE FOLLOWING AAUUOOMMAAIIOONNDDIIRREECCPLC E HERNE
MODULES ARE NO COMPA IBLE WI H HE SSRRIIDDEEEHERNE
SWI CHES AND MEDIA CONVER ER WI H FIBER OP IC CONNEC IONS
BECAUSE HE MODULES HAVE A SPEED OF 10BASEF (FIBER OP IC)
ONLY: E HERNE COMMUNICA IONS MODULE, P/NH2-ECOM-F &
H4-ECOM-F; E HERNE BASE CON ROLLER MODULE, P/NH2-
EBC-F & H4-EBC-F; E HERNE REMO E MAS ER MODULE, P/N
H2-ERM-F & H4-ERM-F.
The J45 Ethernet port connector bodies on the converter are metallic
and connected to the Chassis GND terminal. Therefore, shielded cables
may be used to provide further protection. To prevent ground loops, the
cable shield should be tied to the metal connector body at one end of
the cable only. Electrical isolation is also provided on the Ethernet ports
for increased reliability.
Additional Help and Suppo t
• For additiona product support, specifications, and
insta ation, a User Manua , SE-USER-M, is avai ab e
as a down oadab e PDF fi e from the On ine
Documentation area of the AutomationDirect Web
site.
• For additiona technica support and questions, ca our Technica
Support team @ 770-844-4200.
10-30 VDC, 2.0W
Maximum power
terminal screw
torque is
5.0 lb-in (0.57Nm).
Wire Size Range
24 – 12 AWG
All power, input and output (I/O) wiring must be in accordance with Class I, Division 2 wiring methods and in
accordance with the authority having jurisdiction.
“This Equipment is Suitable for Use in Class I, Division 2, Groups A, B, C, D or Non-Hazardous Locations Only”.
WARNING – EX LOSION HAZARD – SUBSTITUTION OF COM ONENTS MAY IM AIR SUITABILITY FOR CLASS I, DIVISION 2.
WARNING – EX LOSION HAZARD – WHEN IN HAZARDOUS LOCATIONS, DISCONNECT OWER BEFORE RE LACING OR WIRING UNITS.
WARNING – EX LOSION HAZARD – DO NOT DISCONNECT EQUI MENT UNLESS OWER HAS BEEN SWITCHED OFF OR THE AREA IS
KNOWN TO BE NONHAZARDOUS.
WARNING – EX LOSION HAZARD – IN HAZARDOUS OR OTENTIALLY HAZARDOUS LOCATIONS, DO NOT SE ARATE ANY
ART OF THE UNIT WHEN ENERGIZED. USE THE UNIT FOR INTERNAL CONNECTIONS ONLY.
Tout pouvoir, le câblage d’entrée et de sortie (I/O) doivent être conformes aux méthodes de câblage de Classe
I, Division 2 et conformément à l’autorité compétente.
“Cet équipement est adapté pour une utilisation en Classe1, Division 2, Groupes A, B, C et D ou endroits
non-dangereux seulement ”.
AVERTISSEMENT – RISQUE D’EX LOSION – LA SUBSTITUTION DE TOUT COM OSANT EUT NUIRE À LA CONFORMITÉ DE CLASSE I,
DIVISION 2.
AVERTISSEMENT – RISQUE D’EX LOSION – LORSQUE DANS DES ENDROITS DANGEREUX, DÉBRANCHEZ LE CORDON
D'ALIMENTATION AVANT DE REM LACER OU DE BRANCHER LES MODULES.
AVERTISSEMENT – RISQUE D’AVERTISSEMENT – NE DÉBRANCHEZ AS L’ÉQUI EMENT ENDANT QUE LE CIRCUIT EST DIRECT OU À
MOINS QUE L’ENVIRONNEMENT SOIT CONNU OUR ÊTRE LIBRE DE CONCENTRATIONS INFLAMMABLES.
AVERTISSEMENT – RISQUE D’EX LOSION – DANS LES ENDROITS DANGEREUX OU OTENTIELLEMENT DANGEREUX, NE AS
SE ARER UNE ARTIE DE L'UNITE SOUS TENSION. SEULEMENT UTILISEZ L'A AREIL OUR LES CONNEXIONS INTERNES.
WARNING
This manual suits for next models
2
Table of contents
Popular Media Converter manuals by other brands

Blackrock Microsystems
Blackrock Microsystems CerePlex E Series Instructions for use

turck
turck RES Series Instructions for use

Sonos
Sonos Digital Music System Setup guide

Led Control
Led Control LVP603S user manual

Arcam
Arcam fmj D33 user manual

True blue power
True blue power TC230 Installation manual and operating instructions