1) Installing the Module
Wall Mounting
The wall mounting height of the module should be less than or equal to 2 meters
(6.6 feet) from the oor. Use the four mounting holes on the module to secure the
module to the wall. The module can accommodate #6 screws (not included).
Installation of the module should be such that the air ow in the front, back, side
and top vents of the switch are not compromised or restricted.
The accessory cables should have their own strain relief and do not pull down on
the module.
Rack Mounting
The module can be rack mounted using the optional Rack Mount Shelf (8260-0).
Refer to the Rack Mount Shelf user manual (040-08260-001x) for the proper
installation guidelines.
Follow the same guidelines above when rack mounting the module.
DIN-rail Mounting
The module can be DIN-rail mounted using the optional DIN-rail Mounting Bracket
(8250-0) or the optional DIN-rail Mounting Clip (8251-0). Refer to the user manuals
(040-08250-001x or 040-08251-001x) for the proper installation guidelines.
2) Apply Power
AC Power
Secure the ground wire to the grounding screw located on the back of the module.
To power the unit using the AC/DC adapter, route the power cord through the
provided strain relief for additional support. Then connect the barrel connector
at the end of the wire on the AC/DC adapter to the 2.1mm DC barrel connector
(center-positive) on the unit. Connect the AC/DC adapter to the AC outlet. Conrm
that the module has powered up properly by checking the Power LED located on
the front of the installed module.
Installation of the equipment should be such that the air ow in the front, back, side
and top vents of the chassis are not compromised or restricted.
NEVER ATTEMPT TO OPEN THE CHASSIS OR
SERVICE THE POWER SUPPLY. OPENING THE
CHASSIS MAY CAUSE SERIOUS INJURYOR DEATH.
THERE ARE NO USER REPLACEABLE OR
SERVICEABLE PARTS IN THIS UNIT.
WARNING!!!
Page 5
DC Power
This module is intended for installation in restricted access areas. (“Les matériels
sont destinés à être installés dans des EMPLACEMENTS À ACCÈS RESTREINT”).
A restricted access area can be accessed only through the use of a special key, or
other means of security.
The over current protection for connection with centralized DC shall be provided in
the building installation, and shall be a UL listed circuit breaker rated 20 Amps, and
installed per the National Electrical Code, ANSI/NFPA-70.
Appropriate overloading protection should be provided on the DC power source
outlets utilized.
The FPoE/SE requires 48 to 57VDC @ 0.6Amp max rated power and the FPoE+/SE
requires 48 to 57VDC @ 1.12Amp max rated power See specication table for
specic model requirements.
Description IEEE 802.3af PoE IEEE 802.3at PoE+
Power Supply Voltage Range 46.0 to 57.0 VDC 51.0 to 57.0 VDC
Voltage Range at PSE port Output 44.0 to 56.0 VDC 50.0 to 56.0 VDC
Maximum Power from PoE/PSE port 15.4 watts 30 watts
Minimum Voltage at PoE/PD port input* 37.0 VDC 42.5 VDC
Minimum Power at PoE/PD port* 12.95 watts 25.5 watts
* at 100 meters using Cat5
WARNING: OnlyaDC power source that complies with
safety extra low voltage (SELV) requirements can be
connected to the DC-input power supply.
WARNING REGARDING EARTHING GROUND:
o
o
o
o
This equipment shall be connected to the DC supply
system earthing electrode conductor or to a bonding
jumper from an earthing terminal bar or bus to which the
DC supply system earthing electrode is connected.
This equipment shall be located in the same immediate
area (such as adjacent cabinets) as any other equipment
that has a connection between the earthed conductor of
the same DC supply circuit and the earthing conductor,
and also the point of earthing of the DC system. The DC
system shall not be earthed elsewhere.
The DC supply source is to be located within the same
premises as this equipment.
There shall be no switching or disconnecting devices in
the earthed circuit conductor between the DC source and
the earthing electrode conductor.