2-8
7025630 - Revision A - April, 2012
Installation Information International Built-In
International Built-In (ICBBI)
(ICBBI) Series
Series
Electrical Requirements
A 220-240 V AC, 50/60 Hz, 10 amp circuit breaker and
electrical supply are required. A separate circuit, servic-
ing only this appliance, is required.
All Sub-Zero Built-In models are equipped with a power
supply cord with a 3-prong grounding plug, which must
be plugged into a mating 3-prong grounding-type wall
receptacle. Follow the National Electrical Code and
local codes and ordinances when installing the recepta-
cle. For location of the electrical supply, refer to the
Finished Rough Opening Specifications illustration for
your specific model.
IMPORTANT NOTES:
• A ground fault circuit interrupter (GFCI) is not recom-
mended and may cause interruption of operation.
• The Built-In line is equipped with an appliance inlet
type device. This allows easy replacement of the
power cord. The appliance inlet is located at the top
right of the unit toward the rear. When replacing the
power cord make sure that the replacement cord is
rated HO5VV-F3G1.0 or equivalent to ensure safe
operation of the appliance.
DO NOT USE AN EXTENSION CORD OR TWO
PRONG ADAPTER. ELECTRICAL GROUND IS
REQUIRED ON THESE APPLIANCES. DO NOT
REMOVE POWER SUPPLY CORD GROUND
PRONG!
The outlet must be checked by a qualified electri-
cian to be sure that it is wired with the correct
polarity. If the power and neutral polarity are
reversed at the outlet, the appliance will not oper-
ate. Verify that the outlet provides 220-240 V AC
and is properly grounded.
Plumbing Requirements
All International Built-In models with an automatic ice
maker are also equipped with a factory installed water
filter manifold and filter bypass plug. This filter plug can
be replaced with a water filter.
This water supply system operates on water pressure
between 2.1 bar (30 psi) to 6.9 bar (100 psi).
IMPORTANT NOTE: A reverse osmosis system can be
used, provided there is constant water pressure of 2.1
bar (30 psi) to 6.9 bar (100 psi) supplied to the unit at
all times. If a reverse osmosis system is used, it is rec-
ommended that the water filter bypassed plug not be
removed.
Rough in the cold water supply line using 6.35 mm
(1/4") OD copper line. The water line should be routed
up through the floor within 13 mm (1/2'') from the back
wall and no higher than 76 mm (3'') off the floor. If the
water line comes through the wall, make sure it is no
more than 76 mm (3'') from the floor.
Regardless of the routing, allow .9 m (3') of excess cop-
per tubing to remain outside the wall or floor for easy
connection to the unit. The water supply line should be
locate within the shaded area indicated in the Finished
Rough Opening Specifications illustration for the specif-
ic model.
An easily accessible shut-off valve should be used
between the water supply and the unit. Do not use self-
piercing valves. A saddle valve kit (part #4200880) is
available from a Sub-Zero dealer or parts distributor.
It is not recommended that the ice maker be connected
to a softened water supply. Water softener chemicals,
such as salt from a malfunctioning softener, can dam-
age the ice maker and lead to poor ice quality. If a soft-
ened water supply cannot be avoided, be sure that the
water softener is well maintained and operating proper-
ly.
IMPORTANT NOTE: All installations must meet local
plumbing code requirements.
ALWAYS SWITCH POWER OFF AT THE CIRCUIT
BREAKER BEFORE PERFORMING ANY INSTAL-
LATION, SERVICE OR MAINTENANCE.