Sunfire X4600 User manual

Sun Fire X4640 Server Installation Guide
Part No: 821–0240
December 2010, Rev A

Copyright © 2009, 2010, Oracle and/or its aliates. All rights reserved.
This software and related documentation are provided under a license agreement containing restrictions on use and disclosure and are protected by intellectual
property laws. Except as expressly permitted in your license agreement or allowed by law, you may not use, copy, reproduce, translate, broadcast, modify, license,
transmit, distribute, exhibit, perform, publish, or display any part, in any form, or by any means. Reverse engineering, disassembly, or decompilation of this software,
unless required by law for interoperability, is prohibited.
The information contained herein is subject to change without notice and is not warranted to be error-free. If you nd any errors, please report them to us in writing.
If this is software or related software documentation that is delivered to the U.S. Government or anyone licensing it on behalf of the U.S. Government, the following
notice is applicable:
U.S. GOVERNMENT RIGHTS Programs, software, databases, and related documentation and technical data delivered to U.S. Government customers are
“commercial computer software” or “commercial technical data” pursuant to the applicable Federal Acquisition Regulation and agency-specic supplemental
regulations. As such, the use, duplication, disclosure, modication, and adaptation shall be subject to the restrictions and license terms set forth in the applicable
Government contract, and, to the extent applicable by the terms of the Government contract, the additional rights set forth in FAR 52.227-19, Commercial
Computer Software License (December 2007). Oracle America, Inc., 500 Oracle Parkway, Redwood City, CA 94065.
This software or hardware is developed for general use in a variety of information management applications. It is not developed or intended for use in any inherently
dangerous applications, including applications which may create a risk of personal injury. If you use this software or hardware in dangerous applications, then you
shall be responsible to take all appropriate fail-safe, backup, redundancy, and other measures to ensure its safe use. Oracle Corporation and its aliates disclaim any
liability for any damages caused by use of this software or hardware in dangerous applications.
Oracle and Java are registered trademarks of Oracle and/or its aliates. Other names may be trademarks of their respective owners.
AMD, Opteron, the AMD logo, and the AMD Opteron logo are trademarks or registered trademarks of Advanced Micro Devices. Intel and Intel Xeon are
trademarks or registered trademarks of Intel Corporation. All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC
International, Inc. UNIX is a registered trademark licensed through X/Open Company, Ltd.
This software or hardware and documentation may provide access to or information on content, products, and services from third parties. Oracle Corporation and
its aliates are not responsible for and expressly disclaim all warranties of any kind with respect to third-party content, products, and services. Oracle Corporation
and its aliates will not be responsible for any loss, costs, or damages incurred due to your access to or use of third-party content, products, or services.
Ce logiciel et la documentation qui l’accompagne sont protégés par les lois sur la propriété intellectuelle. Ils sont concédés sous licence et soumis à des restrictions
d’utilisation et de divulgation. Sauf disposition de votre contrat de licence ou de la loi, vous ne pouvez pas copier, reproduire, traduire, diuser, modier, breveter,
transmettre, distribuer, exposer, exécuter, publier ou acher le logiciel, même partiellement, sous quelque forme et par quelque procédé que ce soit. Par ailleurs, il est
interdit de procéder à toute ingénierie inverse du logiciel, de le désassembler ou de le décompiler, excepté à des ns d’interopérabilité avec des logiciels tiers ou tel que
prescrit par la loi.
Les informations fournies dans ce document sont susceptibles de modication sans préavis. Par ailleurs, Oracle Corporation ne garantit pas qu’elles soient exemptes
d’erreurs et vous invite, le cas échéant, à lui en faire part par écrit.
Si ce logiciel, ou la documentation qui l’accompagne, est concédé sous licence au Gouvernement des Etats-Unis, ou à toute entité qui délivre la licence de ce logiciel
ou l’utilise pour le compte du Gouvernement des Etats-Unis, la notice suivante s’applique :
U.S. GOVERNMENT RIGHTS. Programs, software, databases, and related documentation and technical data delivered to U.S. Government customers are
"commercial computer software"or "commercial technical data"pursuant to the applicable Federal Acquisition Regulation and agency-specic supplemental
regulations. As such, the use, duplication, disclosure, modication, and adaptation shall be subject to the restrictions and license terms set forth in the applicable
Government contract, and, to the extent applicable by the terms of the Government contract, the additional rights set forth in FAR 52.227-19, Commercial
Computer Software License (December 2007). Oracle America, Inc., 500 Oracle Parkway, Redwood City, CA 94065.
Ce logiciel ou matériel a été développé pour un usage général dans le cadre d’applications de gestion des informations. Ce logiciel ou matériel n’est pas conçu ni n’est
destiné à être utilisé dans des applications à risque, notamment dans des applications pouvant causer des dommages corporels. Si vous utilisez ce logiciel ou matériel
dans le cadre d’applications dangereuses, il est de votre responsabilité de prendre toutes les mesures de secours, de sauvegarde, de redondance et autres mesures
nécessaires à son utilisation dans des conditions optimales de sécurité. Oracle Corporation et ses aliés déclinent toute responsabilité quant aux dommages causés
par l’utilisation de ce logiciel ou matériel pour ce type d’applications.
Oracle et Java sont des marques déposées d’Oracle Corporation et/ou de ses aliés.Tout autre nom mentionné peut correspondre à des marques appartenant à
d’autres propriétaires qu’Oracle.
AMD, Opteron, le logo AMD et le logo AMD Opteron sont des marques ou des marques déposées d’Advanced Micro Devices. Intel et Intel Xeon sont des marques ou
des marques déposées d’Intel Corporation. Toutes les marques SPARC sont utilisées sous licence et sont des marques ou des marques déposées de SPARC
International, Inc. UNIX est une marque déposée concédé sous license par X/Open Company, Ltd.
121005@25097

Contents
Preface ......................................................................................................................................................5
Product Information Web Site ......................................................................................................5
Related Books ..................................................................................................................................5
About This Documentation (PDF and HTML) ..........................................................................7
We Welcome Your Comments .....................................................................................................8
Change History ...............................................................................................................................8
Installation Overview .............................................................................................................................9
Sun Fire X4640 Server Front and Back Panel Features and Components .................................... 11
Sun Fire X4640 Server Front Panel Features and Components .............................................. 11
Sun Fire X4640 Server Back Panel Features and Components ............................................... 12
Installing the Server Hardware .......................................................................................................... 15
Contents of the Box and Optional Documentation Media Kit ............................................... 15
Tools and Sta Required ............................................................................................................. 16
Compatible Racks ........................................................................................................................ 17
Slide Rail Kit ................................................................................................................................. 18
How to Remove Components to Reduce Weight .................................................................... 19
How to Install the Express Slide Rails Onto the Server and the Rack .................................... 20
How to Insert the Server Into the Rack ...................................................................................... 21
How to Verify Slide-Rail Operation .......................................................................................... 23
Installing the Cable Management Arm (CMA) ....................................................................... 24
How to Attach the Cable Management Arm (CMA) ............................................................... 25
How to Verify Cable Management Arm (CMA) Operation ................................................... 28
How to Remove the Cable Management Arm (CMA) ............................................................ 28
Removing the Server From the Rack ................................................................................................. 29
How to Remove the Server From the Rack ............................................................................... 29
Cabling and Power .............................................................................................................................. 33
Cabling Diagram .......................................................................................................................... 33
How to Cable the Server .............................................................................................................. 34
3

How to Apply Standby Power for Initial Service Processor Conguration .......................... 35
How to Power On All Server Components ............................................................................... 36
How to Power O the Server ...................................................................................................... 37
Getting Service for Your Server ......................................................................................................... 39
How to Find the Server's Serial Number ................................................................................... 39
Sun Fire X4640 Server Specications ................................................................................................ 41
Physical Specications For the Sun Fire X4640 Server ............................................................ 41
Power Specications For the Sun Fire X4640 Server ............................................................... 41
Environmental Specications .................................................................................................... 42
Acoustic Specications ................................................................................................................ 42
Managing Your Server ........................................................................................................................ 43
Overview of ILOM Software ....................................................................................................... 44
Communicating With the ILOM and the System Console ............................................................ 45
Server Connections ...................................................................................................................... 45
About ILOM SP IP Addresses and the ILOM Interfaces ......................................................... 47
Determining the SP IP Address .................................................................................................. 47
Connecting to the ILOM .............................................................................................................49
Connecting to the System Console ............................................................................................ 52
Setting Up Your Operating System ................................................................................................... 59
OS Information Links .................................................................................................................. 59
Conguring the Preinstalled Solaris OS .................................................................................... 60
(Optional) How to Redirect the Console Output to the Video Port ...................................... 63
How to Connect to the Server Using a Serial Capture Program ............................................. 63
Solaris OS Information Products and Training ....................................................................... 64
Index ......................................................................................................................................................65
Contents
Sun Fire X4640 Server Installation Guide • December 2010, Rev A4

Preface
This preface describes related documentation, submitting feedback, and a document change
history.
■“Product Information Web Site” on page 5
■“Related Books” on page 5
■“About This Documentation (PDF and HTML)” on page 7
■“We Welcome Your Comments” on page 8
■“Change History” on page 8
Product Information Web Site
For information about the Sun Fire X4640 server, go to the following web site:
http://www.oracle.com/goto/x86
Click “Previous Products” from the left nav menu.
At that site, you can nd links to the documentation, parts lists and downloads.
Related Books
The following is a list of documents related to your Oracle Sun Fire X4640 server. These and
additional support documents are available on the web at:
http://docs.sun.com/app/docs/prod/server.x64#hic
Document Group Document Description
Sun Fire X4640 Server-Specic
Documentation
Sun Fire X4640 Server Product
Documentation
Integrated HTML version of all
starred (*) documents, including
Search and Index.
Sun Fire X4640 Server Getting Started
Guide
Pictorial setup quick reference.
5

Document Group Document Description
“Installation Overview” on page 9* How to install, rack, and congure
the server up to initial power-on.
“Overview of the Sun Fire X4640 Server
Product Notes” in Sun Fire X4640
Server Product Notes*
Important late-breaking
information about the Sun Fire
X4640 server.
“Introduction to Sun Installation
Assistant” in Sun Installation
Assistant 2.3 through 2.4 User’s Guide
for x64 Servers*
A Sun tool used to perform an
assisted installation of a supported
Windows or Linux OS, upgrade
rmware (regardless of OS), and
other tasks.
Introduction to Solaris OS and
OpenSolaris Installation*
How to install the Solaris OS on
your server.
“Introduction to Linux Installation” in
Sun Fire X4640 Server Linux
Installation Guide*
How to install a supported Linux
OS on your server.
“Introduction to Windows Installation”
in Sun Fire X4640 Server Windows
Installation Guide*
How to install supported versions
of Microsoft Windows on your
server.
“Introduction to ESX Installation” in
Sun Fire X4640 Server ESX Installation
Guide*
How to install supported versions
of the ESX OS on your server.
Sun ILOM 3.0 Supplement for the Sun
Fire X4640 Server*
Version-specic supplemental
information for your server's
Integrated Lights Out Manager.
Sun Fire X4640 Server Diagnostics
Guide*
How to diagnose problems with
your server.
“Sun Fire X4640 Server Service Manual
Overview” in Sun Fire X4640 Server
Service Manual*
How to service and maintain your
server.
Sun Fire X4640 Server Safety and
Compliance Guide
Safety and compliance information
about your server.
4U Express Rail Rackmounting Kit
Label
Pictorial label on racking your
server
Sun Fire X4640 System Overview Label Pictorial label on servicing your
server
Sun Fire X4640 Top Cover Label Pictorial label on removing
components
Related Books
Sun Fire X4640 Server Installation Guide • December 2010, Rev A6

Document Group Document Description
Sun Fire X4640 CPU Matrix Label Pictorial label on CPU module and
llers
Sun Integrated Controller Disk
Management
Sun x64 Server Disk Management
Overview
Information about managing your
server's storage.
Sun LSI 106x RAID Users Guide Information about LSI RAID
features
x64 Servers Applications and
Utilities Reference
Documentation
Sun x64 Server Utilities Reference
Manual
How to use the available utilities
included with your server.
Oracle Integrated Lights Out
Manager (ILOM) 3.0
Documentation
Oracle Integrated Lights Out Manager
(ILOM) 3.0 Feature Updates and Release
Notes
Information about new ILOM
features
Oracle Integrated Lights Out Manager
(ILOM) 3.0 Getting Started Guide
Overview of ILOM 3.0
Oracle Integrated Lights Out Manager
(ILOM) 3.0 Concepts Guide
Conceptual information on ILOM
3.0
Oracle Integrated Lights Out Manager
(ILOM) 3.0 Web Interface Procedures
Guide
How to use ILOM through the web
interface
Oracle Integrated Lights Out Manager
(ILOM) 3.0 CLI Procedures Guide
How to use ILOM through
commands
Oracle Integrated Lights Out Manager
(ILOM) 3.0 Management Protocols
Reference Guide
Information on management
protocols
About This Documentation (PDF and HTML)
This documentation set is available in both PDF and HTML. The information is presented in
topic-based format (similar to online help) and therefore does not include chapters, appendices
or section numbering.
About This Documentation (PDF and HTML)
7

We Welcome Your Comments
Oracle is interested in improving its documentation and welcomes your comments and
suggestions. To share your comments, go to http://docs.sun.com and click Feedback.
Change History
The following changes have been made to the documentation set.
■October 2009, initial publication
■January 2010, two documents revised
■Service Manual - Revised DIMM population rules and addressed illustration issues
■Product Notes - Revised software information and xed bugs
■April 2010, one document revised
■Installation Guide - Revised power specications
■December 2010, two documents revised
■Service Manual - Revised motherboard FRUID update instructions
■Product Notes - Revised software information and xed bugs
We Welcome Your Comments
Sun Fire X4640 Server Installation Guide • December 2010, Rev A8

Installation Overview
This document describes how to install and power on Oracle's Sun Fire X4640 server for the
rst time. After unpacking your server, perform the following steps.
Task Description Link
1. Familiarize yourself with
the server features.
“Sun Fire X4640 Server Front and Back Panel
Features and Components” on page 11
2. Install the server into a
rack using slide rails.
“Installing the Server Hardware” on page 15
3. Connect power cords,
cables, and peripherals.
“Cabling Diagram” on page 33
4. Power on the server. “How to Apply Standby Power for Initial
Service Processor Conguration” on page 35
5. Check system
specications.
“Sun Fire X4640 Server Specications” on
page 41
6. Manage the server. “Managing Your Server” on page 43
“Communicating With the ILOM and the
System Console” on page 45
7. Congure or install an
OS:
Congure the optional
preinstalled Solaris OS.
“Setting Up Your Operating System” on
page 59
For installation of Solaris OS. “Introduction to Solaris OS and OpenSolaris
Installation” in Sun Fire X4640 Server Solaris
OS Installation Guide
For assisted installation of Linux Recommended method. Refer to the
documentation for your version of Oracle's
Sun Installation Assistant at:
http://docs.sun.com/
app/docs/prod/install.x64svr
For unassisted installation of
Linux
“Introduction to Linux Installation” in Sun
Fire X4640 Server Linux Installation Guide
9

Task Description Link
For assisted installation of
Windows
Recommended method. Refer to the
documentation for your version of Oracle's
Sun Installtion Assistant at:
http://docs.sun.com/
app/docs/prod/install.x64svr
For unassisted installation of
Windows
“Introduction to Windows Installation” in
Sun Fire X4640 Server Windows Installation
Guide
For installation of ESX “Introduction to ESX Installation” in Sun Fire
X4640 Server ESX Installation Guide
Installation Overview
Sun Fire X4640 Server Installation Guide • December 2010, Rev A10

Sun Fire X4640 Server Front and Back Panel
Features and Components
■“Sun Fire X4640 Server Front Panel Features and Components” on page 11
■“Sun Fire X4640 Server Back Panel Features and Components” on page 12
Sun Fire X4640 Server Front Panel Features and Components
For back panel features and components, see “Sun Fire X4640 Server Back Panel Features and
Components” on page 12.
11

Figure Legend
1 Locate button/LED (white) 7 System overheat fault LED
2 Service action required LED
(amber)
8 Hard drive status LEDs
3 Power/OK LED (green) 9 USB ports (2)
4 Power button 10 DVD module
5 Top fan fault LED 11 Hard drives (4 maximum)
6 Rear power supply fault LED
Sun Fire X4640 Server Back Panel Features and Components
For front panel features and components, see “Sun Fire X4640 Server Front Panel Features and
Components” on page 11.
Sun Fire X4640 Server Back Panel Features and Components
Sun Fire X4640 Server Installation Guide • December 2010, Rev A12

Figure Legend
1 Power supplies (4) 8 Video connector
2 Locate button/LED (white) 9 Serial management port
3 Service Action required LED
(amber)
10 USB ports (2 external, 1 internal on motherboard)
4 Power /OK LED (green) 11 10/100/1000 GigabitEthernet ports (4)
5 10/100 Ethernet port (for net
management)
12 NMI dump switch (SW3)
6 PCI-X card slots (2) 13 Reset switch (SW2)
7 PCIe card slots (3) 14 PCIe card slots (3)
Sun Fire X4640 Server Back Panel Features and Components
13

14

Installing the Server Hardware
■“Contents of the Box and Optional Documentation Media Kit” on page 15
■“Tools and Sta Required” on page 16
■“Compatible Racks” on page 17
■“Slide Rail Kit” on page 18
■“How to Remove Components to Reduce Weight” on page 19
■“How to Install the Express Slide Rails Onto the Server and the Rack” on page 20
■“How to Insert the Server Into the Rack” on page 21
■“How to Verify Slide-Rail Operation” on page 23
■“Installing the Cable Management Arm (CMA)” on page 24
■“How to Attach the Cable Management Arm (CMA)” on page 25
■“How to Verify Cable Management Arm (CMA) Operation” on page 28
■“How to Remove the Cable Management Arm (CMA)” on page 28
Contents of the Box and Optional Documentation Media Kit
In addition to your server and power cords, you will nd the following items:
■Getting Started Guide
■Legal and safety documents
■DB9-RJ45 serial port adapter (530–3100) used to connect an Ethernet cable
You can optionally order a Documentation Media Kit that includes the following.
Item Description Notes
Installation Guide Printed version of this
manual.
You can also get the PDF free at:
http://docs.sun.com
Tools and Drivers
CD/DVD
Includes BIOS, SP, and LSI
rmware as well as OS drivers.
See the product information web site, listed in
http://www.oracle.com/goto/x86
Click “Previous Products” from the left nav menu.
15

Item Description Notes
Sun Installation
Assistant CD/DVD
Software application to
update rmware (regardless
of OS) and to assist in
installing Windows and Linux
OSes.
Current version is available at:
http://www.sun.com/systemmanagement/sia.jsp
SunVTS CD/DVD Sun Validation Test Suite tests
and validates Sun hardware by
verifying the conguration
and functionality of hardware
controllers, devices, and
platforms.
See the product information web site, listed in
http://www.oracle.com/goto/x86
Click “Previous Products” from the left nav menu.
Tools and Sta Required
Caution – To avoid serious personal injury and equipment damage, always use all four chassis
handles to support the product weight when handling or moving the product.
Caution – The server weighs about 88 pounds (40 kg) when fully loaded with components. To
reduce the risk of serious personal injury or equipment damage, use a mechanical lift to install
the server into the rack. If a lift is not available, remove components as described in “How to
Remove Components to Reduce Weight” on page 19. This reduces the weight of the server to
35 pounds (16 kg).
Caution – Always load equipment into a rack from the bottom up so that it does not become
top-heavy and tip over. Deploy your rack’s anti-tilt bar to prevent the rack from tipping during
equipment installation.
Before installing the server into a rack, gather the tools, equipment, and sta required.
Tools, Equipment, and Stang Required Notes
Two trained sta Two people are needed to install the server and operate the lift.
#2 10–inch Phillips screwdriver
(magnetic tip recommended)
Optional. Required if you are hardmounting the server.
Mechanical lift Strongly recommended. If not available, reduce the weight of the server.
See “How to Remove Components to Reduce Weight” on page 19.
Tools and Sta Required
Sun Fire X4640 Server Installation Guide • December 2010, Rev A16

Tools, Equipment, and Stang Required Notes
Compatible rack See “Compatible Racks” on page 17.
Slide rails Optional. See “Slide Rail Kit” on page 18.
Cable management arm Optional. See “Installing the Cable Management Arm (CMA)” on
page 24.
Compatible Racks
The slide rails are compatible with a wide range of equipment racks that meet the following
standards:
■Four-post rack (mounting at both front and rear).
Note – Two-post racks are not compatible.
■Rack should have horizontal opening and unit vertical pitch conforming to ANSI/EIA
310-D-1992 or IEC 60927 standards.
■Distance between front and rear mounting planes between approximately 26 to 34.5 inches
(660.4 mm and 876.3 mm).
■Minimum clearance depth (to front cabinet door) in front of front rack mounting plane: 1
inch (25.4 mm).
■Minimum clearance depth (to rear cabinet door) behind front rack mounting plane: 31.5
inches (800 mm) with cable management arm (recommended) or 27.5 inches (700 mm)
without the cable management arm.
■Minimum clearance width (between structural supports and cable troughs) between front
and rear mounting planes: 18 inches (456 mm).
Note – The 4U Express Rail Rackmounting Kit card that is included with the slide rails and cable
management assembly refers to the rack as a retma (Radio Electronics Television
Manufacturers Association) rack.
Compatible Racks
17

Slide Rail Kit
The slide rail kit that comes with your server is called the express slide rail or the tool-less slide
rail because it is simpler than older slide rails. It can be used with both square-hole and
round-hole racks. The cable management arm (CMA) might come in a separate box.
Figure Legend
1 Slide rail (2) Attaches to rack post. The slide rail has an outer
rail and a middle section. The middle section
has the ball bearings which slide forward and
backward. Each end of the slide rail has an
attachment assembly.
2 Mounting bracket (2) Attaches to server. The mounting bracket is
also called the inner section because it is
inserted into the middle section of the slide rail.
3 (Optional) Cable management arm (CMA) Included only with Express Slide Rail and CMA
combination kit.
4 Shipping/hardmount hardware Note – If you want to secure the server for
shipping now or in the future, use the shipping
hardware. It is not possible to install the
shipping hardware after the slide rails are
installed. It is better to install the shipping
hardware during the slide rail installation.
Slide Rail Kit
Sun Fire X4640 Server Installation Guide • December 2010, Rev A18

The slide rail kit comes with the following shipping hardware:
Figure Legend
1 M6 screws (9) To secure server for shipping, install 8 screws, 2 per rack
post.
One extra screw is supplied.
2 Cage nuts Cage nuts are required for shipping server in square-hole
racks.
▼How to Remove Components to ReduceWeight
Caution – Circuit boards and hard drives contain electronic components that are extremely
sensitive to static electricity. Ordinary amounts of static electricity from clothing or the work
environment can destroy the components located on these devices. Do not touch the
components without antistatic precautions, especially along the connector edges. For more
information, see “Antistatic Procedures and Precautions” in Sun Fire X4640 Server Service
Manual.
If a lift is not available, remove the following components to reduce weight:
■All four power supplies
■All four fan trays
■All modules in the CPU bay (CPU modules and ller modules)
This reduces the weight of the server to about 35 pounds (16 kg).
“Removing and Installing Components” in Sun Fire X4640 Server Service Manual.
Before You Begin
●
See Also
Slide Rail Kit
19

▼How to Install the Express Slide Rails Onto the Server
and the Rack
Installing the slide rails and cable management arm for the rst time takes approximately 45 to
60 minutes.
Note – The express slide rail kit comes with the 4U Express Rail Rackmounting Kit card that
contains illustrations that you should refer to during this procedure. It can also be used to block
out the 4 unit (4U) space to be occupied by the server.
Attach the mounting brackets to the server.
Each mounting bracket has a at side, which ts against the server chassis. The other side has a
pair of rims that t into the slide rails. Each bracket has 6 key-shaped holes which t over the
pins on the side of the server.
Note – The last (rear-most) hole is not used.
a. Position a bracket so that the green lock levers are at the front of the server and the holes on
the bracket are over the pins on the server.
b. Hang the bracket on the pins.
The middle of the bracket will bow out slightly so that the middle hole does not engage.
c. Press down on the center of the bracket and slide forward.
All 5 pins should lock into place with an audible click.
d. Repeat the above steps with the other bracket.
Use the installation card to determine the 4U space that will be occupied by the server.
The slide rails cover the holes on the 2U space on the bottom of the 4U space that is occupied by
the server.
The installation card is designed so that it exactly covers a 4U space in the rack. The lower half
of the card is narrower than the rest, so that the holes used by the slide rails are visible.
(Optional for securing the server and slide rails for shipping) If you plan to ship the server and
slide rails in place and you have a rack with square holes, place cage nuts in the holes at the top
and the bottom of the 2U slide rail space. It is not possible to install the cage nuts after the slide
rail is installed.
1
2
3
Slide Rail Kit
Sun Fire X4640 Server Installation Guide • December 2010, Rev A20
Table of contents
Other Sunfire Server manuals
Popular Server manuals by other brands

GRASS VALLEY
GRASS VALLEY K2 SOLO - Service manual

SpectraLink
SpectraLink DECT Server 2500 manual

Sun Microsystems
Sun Microsystems Sun Fire X2100 M2 installation guide

Roam
Roam RoamView Setup guide

SpectraLink
SpectraLink NetLink SVP010 Installation, configuration and administration

Axel
Axel AX4020 installation guide

Lenovo
Lenovo ThinkServer RD230 Installation and user guide

Supermicro
Supermicro SuperStorageServer SSG-6019P-ACR12L user manual

AIC
AIC HA202-PV user manual

ACE COMPUTERS
ACE COMPUTERS PWKS1AA25UTRT user manual

AOS
AOS SD Streaming server Installation and operation manual

Gigabyte
Gigabyte R182-NC0 user manual