SUNLUNE JASMINER X4 User manual

1
JASMINER X4 High-throughput 1U/1U-C Server Instruction
JASMINER X4
High-throughput 1U /1U-C Server Instruction
Manual
Tip: Follow the official account of SUNLUNE , then reply “course” to get the use
demonstration video of the device.
SUNLUNE Technology (Nantong) Co., Ltd.
August 2021

2
JASMINER X4 High-throughput 1U/1U-C Server Instruction
Catalogue
I Product introduction....................................................................................................3
II Product features............................................................................................................3
III Inspection before use................................................................................................3
IV Description...................................................................................................................5
V Settings...........................................................................................................................7

3
JASMINER X4 High-throughput 1U/1U-C Server Instruction
JASMINER X4 High-throughput 1U /1U-C Server Instruction Manual
I Product Introduction
JASMINER X4 high-throughput 1U/1U-C server, is a ethash server with
high-throughput technology developed by SUNLUNE technology (Nantong) Co., Ltd.
JASMINER X4 based on memory computing integrated high-throughput computing chip.
The chip with memory computing integrated structure realizes the combination of
storage and computing, Under the condition of meeting the requirements of storage
capacity, it improves the memory access bandwidth, breaks through the bottleneck of
computing power, save power and size,providing sufficient computing power, exquisite
low-noice design , solid and quite. with the integrated memory and computing
architecture and high- throughput technology, JASMINER X4 suitable for PoW algorithms
such as ETCHASH and ETHASH, satisfy various customers and bring them a good return
on investment.
II Product features
Excellent performance and easy to use,Exquisite design, friendly interface and simple
operation. Just need set a few parameters.Simple interface,power supply and network
access is required. Excellent computing performance, efficient and concise IO expansion
capability and high stability.
Energy saving, environment friendly and widely used
Very low power consumption, low-noice design, high efficiency , environment
friendly production. Environmental temperature≤40 °C.
III Inspection before use
1.Inspection before use
After unpacking, please check for any package deformation or interface damage.
If there is any fault, please contact the after-sales department.
Check for abnormal sound, metal collision or screw loosen.If there is any fault,
please contact the after-sales department.

4
JASMINER X4 High-throughput 1U/1U-C Server Instruction
2.Attention
The device should be connected to router or Exchanger without Poe function, only
wired network connection can be used.
To avoid heat dissipation, do not stack or cover the device with other objects.
Please run the device under the recommended operating environment (operating
temperature: 0-40℃, operating humidity: 5% RH~95% RH, non condensation;
altitude of 2000 meters below and under non tropical climate conditions) to avoid
affecting the normal operation or performance of the device.
Pay attention to dust and foreign matters,otherwise, the mainboard may be
corroded and the device cannot work properly.
Private renovation is not guaranteed.
There are four protective sleeves are equipped to prevent edge scratches. Please
insert the protective sleeve for safety before use.
IV Basic description
1. Device
JASMINER X4 high-throughput 1U server
Attention:
Place the device as shown in the figure above. Do not place the device in a closed space.
For your safety, do not remove any screws or fasteners from the device.
The device will generate heat during operation. Please avoid touching the black shell
during operation.
2.parameter
Overview
Specification
Type
JASMINER X4
Name
High-throughput 1U/1U-C server
Encryption algorithm
ETCHASHÐASH

5
JASMINER X4 High-throughput 1U/1U-C Server Instruction
Hashrate(MH/s)
520/450±10%
INPUT
200-240V~,50/60Hz,1.2A
power consumption(Watt)
240±10%
Energy efficiency ratio (25 ° C
ambient temperature, J / MH)
0.46/0.53±10%
Hardware Configuration
Network connection
RJ45 Ethernet 10/100/1000M
Device size (mm)
482.2×44.5×450.0
Package size (mm)
586×126× 513
Device weight(kg)
9.4
Overall weight (including package,
kg)
10.3
2. Interface and description
TF card
TF Card slot
IP Report
When using IP report software, the high-throughput 1U
server IP address will be feedback to your PC
ETH
network interface
Reset
Restore factory setting
Alarm lamp
(red)
Continuous light indicates device failure
Operation lamp
(green)
Flashing light indicates device running well
IVUse and settings
1. Connection inspection
IP Report
Network interface
Power port / AC IN
TF Card slot
Reset
Alarm lamp(red)
Alarm lamp(green)

6
JASMINER X4 High-throughput 1U/1U-C Server Instruction
a) Network cable connection: Insert the RJ45 crystal head into the
network interface marked with ETH of the router and the device interface
respectively. Pay attention to the direction when inserting the cable.
Please insert the crystal head in place.
b) Power cable connection: Connect the Power output end of the
adapterto the Power port labeled Power of the device, and then connect
the 220V AC Power to the device for normal operation.
2. Configuring equipment
Configuring with JASMINER Group Control Software
Download the "IP Group Control Management Software" from the JASMINER website
→ Service → Firmware and Software → Other;
Install the sl_miner.exe program (IP group control management software) on a
Windows PC, double click on it and run it, note that the PC needs to be on the same
network segment as the device;
After successful installation as shown below, click on "Auto Generate" → "Start Scan"
in the software interface, the software will automatically pop up information about the
device after the scan is complete.

7
JASMINER X4 High-throughput 1U/1U-C Server Instruction
Check the machines need to be configured
Copy and paste the obtained pool address into the pool, then copy and paste the
sub-account (worker) into the wallet/account number (if you do not have a registered
pool, you need to register for the pool first, refer to the pool registration tutorial for
details).

8
JASMINER X4 High-throughput 1U/1U-C Server Instruction
Select the algorithm, the device supports both ETH and ETC algorithms, with the
default being the ETH algorithm;
select the operating frequency, the default is 200 MHz;
clicking on Configure Miner to start the configuration;
Check the hash rate
After the device running for about 30 minutes, you will be able to view the
corresponding hash rate information.

9
JASMINER X4 High-throughput 1U/1U-C Server Instruction
At this point the configuration of the high throughput server has been completed
and the machine can work normally.
3.Other settings: double click on the device in the group control software to enter
the web page for modification and setting.
*Up to now, all parameters have been set.
If you would like to know more about device setup you can read items 4 and 5.
4.Setup without IP group control management software.
Enter the shown IP address into the browser and press enter to open the device web
operation interface.
Default user name: root Default password: root

10
JASMINER X4 High-throughput 1U/1U-C Server Instruction
Enter the "miner" configuration interface to modify the ore pool settings
and let the device start to provide hashate for you.
Enter the preferred and two alternative mining pool addresses, account
name and password.
Select the algorithm. The device support both ETCHASH and ETHASH
algorithm. Default algorithm is ETCHASH.
Click "update" to submit the configuration.
View hashrate
After 30 minutes running, we can find device hashrate on Status page.
Configuration of this high-throughput server is complete.

11
JASMINER X4 High-throughput 1U/1U-C Server Instruction
5.Other settings
IP setting: If you need to change the network configuration such as IP
address, select the "network" configuration item, and the device will dynamically
obtain the IP address by default. After the change, click "update" to take effect.
Modify login password: If you need to change the login name and
password. Select the "admin" configuration item. The default login name of the
device is root and the default password is root. After the change, click "update"
to take effect.
View log: If you want to view the log information of the system operating.
You can select the "log" option.

12
JASMINER X4 High-throughput 1U/1U-C Server Instruction
Upgrade system firmware: Select the "upgrade" option, select the
firmware to be upgraded, and click "upload image" to complete the upgrade
operation.
Restart the device: Select "reboot" and click "reboot now".

Restore the device to the factory settings, select "reset", and click
"reset now".
Other manuals for JASMINER X4
4
Table of contents
Other SUNLUNE Server manuals
Popular Server manuals by other brands

Compaq
Compaq 108164-003 - ProLiant - 800 Integration notes

Intergraph
Intergraph InterServe 80 SL System setup

Lenovo
Lenovo System x3550 M5 Product guide

Acksys
Acksys COMETH V2 quick start

HP
HP ProLiant SL160z Generation 6 (G6) overview

Planet Networking & Communication
Planet Networking & Communication ICS-110 Installation