NONRETURN VALVES:
Non-return valves must be installed
if the air for your Sunshower is
extracted from a humid area,
e.g. from the outside or from the
bathroom. Please refer to the
image and subsequent pages for
instructions. The non-return valves
can be ordered additionally (as a
set with the glass panels) or can
be purchased separately at your
hardware store.
Examples of humid areas:
bathroom, outside.
Examples of dry areas:
bedroom, hallway, toilet.
GENERAL CONSTRUCTION
GUIDELINES:
• All Sunshower appliances must
be installed with ventilation
ducts
• Ventilation feed and exhaust can
both be a maximum of 3 m
• The space from which/to which
ventilation is provided must be
at least 12 m3
• The ducts can be of any material,
with dimensions Ø100 mm or 110
* 55 mm
• Make as few bends as possible in
the ducts
• The Sunshower may not be
connected to an existing
ventilation system
PREPARATION
VENTILATION
DRY AREA
BATHROOM
OUTSIDE
SHOWER AREA
PAGE 9
PREFERRED
PAGE 10
PAGE 10
NOT POSSIBLE
ROUND NON
RETURN VALVE
RECTANGULAR
NONRETURN
VALVE
INSTALLATION GUIDE DELUXE | PART I | P1071 REV N