Operation Manual
Pump with Filter
CHJ-502, CHJ-602, CHJ-902
50325–50327
Illustration similar, may vary depending on model
Read and follow the operating instructions and safety information before using for the first time.
Technical changes reserved!
Due to further developments, illustrations, functioning steps and technical data can differ insignific -
antly.
Updating the documentation
If you have suggestions for improvement or have found any irregularities, please contact us.
The information contained in this document may alter at any time without previous notice. It is prohib-
ited to copy or spread any parts of this document in any way without prior written allowance. ll rights
reserved.
The WilTec Wildanger Technik GmbH cannot be held accountable for any possible mistakes in this
operating manual, nor in the diagrams and figures shown.
Even though, the WilTec Wildanger Technik GmbH has undergone biggest possible efforts to ensure
that the operating manual is complete, faultless and up to date, mistakes cannot be entirely avoided.
If you should find a mistake or wish to make a suggestion for improvement, we look forward to hearing
from you.
Send an e-mail to:
[email protected]
or use our contact form:
https://www.wiltec.de/contacts/
The most recent version of this manual in various languages can be found in our online shop via:
https://www.wiltec.de/docsearch
Our postal address is:
WilTec Wildanger Technik GmbH
Königsbenden 12
52249 Eschweiler
Germany
Do you wish to pick goods up? Our pick-up address is:
WilTec Wildanger Technik GmbH
Königsbenden 28
52249 Eschweiler
Germany
To shorten the waiting time and allow for a rapid on-site transaction, we ask you to call us previously
or placing your order via the webshop.
E-mail: [email protected]
Tel:+49 2403 55592-0
Fax: +49 2403 55592-15
To return orders for exchange, repair or for other purposes, please use the following address. tten -
tion! To allow for a smooth execution of your complaint or return, it is important to contact our cus -
tomer service team before returning the goods.
Returns Department
WilTec Wildanger Technik GmbH
Königsbenden 28
52249 Eschweiler
E-mail: [email protected]
Tel:+49 2403 55592-0
Fax: +49 2403 55592-15
© by WilTec Wildanger Technik GmbH Item 50325–50327 Page 2
http://www.WilTec.de
http://www.aoyue.eu 01 2021-1
http://www.teichtip.de
Introduction
Thank you for purchasing this quality product. To minimize the ri k of injury we urge that our cli-
ent take ome ba ic afety precaution when u ing thi device. Plea e read the operation in-
truction carefully and make ure you have under tood it content.
Keep these operation instructions safe.
Safety regulation
CAUTION:
On standing water bodies, garden ponds, swimming ponds as well as in their surrounding
areas, you have to use the device only with a residual current circuit breaker with a triggering
nominal current up to 30>m (according to VDE 0100 part 702 and 738).
The device is not suitable for the use in swimming pools, in any kind of paddle pools or any
other water bodies during the operation of which there are humans or animals in the water.
Commissioning the device during the stay of humans or animals in the danger zone is not al-
lowed. sk your electrician!
This device must not be used by persons (including children) with reduced physical, sensory
or mental capabilities, or with a lack of experience and/or knowledge, unless they are super-
vised by a person responsible for their safety or have been given instructions concerning the
use of the device.
Children should be supervised to ensure that they do not play with the device.
ATTENTION:
Perform a visual inspection of the device before each use. Do not use the device if the safety
equipment is damaged or worn. Never put the safety equipment out of force.
Only use the device for the purpose as specified in this manual.
You are responsible for the safety in the work area.
If the power cord or the plug is damaged by external influences, the cord must not be repaired!
Since the cord is moulded with the stator, a replacement is not possible, the pump must be
scrapped.
The specified unit voltage of 230>V C as indicated on the nameplate has to match the exist-
ing mains voltage.
Never lift, transport or attach the device by the power cord.
Make sure that the electrical connectors are located in a flood-safe area and that they are pro-
tected against moisture.
Pull the power plug before working on the device.
The operator is responsible for the compliance with the local safety and installation regula-
tions.
The user has to exclude, by taking the appropriate measures (e.>g. installation of an alarm
system, reserve pump, etc.), any consequential damage due to flooding of areas and faults in
the device.
If there is a failure of the device, the repairing is only to be done by a professional electrician.
The device must never run dry or be operated with fully closed suction pipe. For the damage
in the device caused by a dry run the manufacturer’s warranty will be void.
The device must not be used for the operation in swimming pools.
The device must not be installed in the portable water circulation.
© by WilTec Wildanger Technik GmbH Item 50325–50327 Page 3
http://www.WilTec.de
http://www.aoyue.eu 01 2021-1
http://www.teichtip.de
WARNING:
Read all afety in truction !
Failure concerning the warnings and instructions may result in electric shock, fire and/or serious injury.
Keep all warnings and instructions for the future.
Re i tance
s for the continuous operation, the maximum temperature of the liquid to be transported
should not exceed +35> .℃
This pump must not be used to transport any combustible, gasing or explosive liquids.
Electrical connection
The electrical connection is made to a grounded socket 230>V ~ 50>Hz protection at least
10> .
The device is switched on and off by using the built-in ON / OFF switch. When the engine is
turned on, the control lamp in the interior of the switch lights up.
The engine is protected against overloading or blocking by a built-in thermal protection. In
case of overheating, the pump is switched off automatically by the protection. fter cooling
down, the pump re-switches on automatically.
Main connection
Your pond pump is already equipped with a grounded plug. The pump is meant to be for a connection
to a grounded socket with 230>V ~ 50>Hz. Make sure that the socket is sufficiently secured (at least
6> ) and in a good condition. Run the pump plug into the socket. The pump is ready for operation.
Never operate the pump if the cord or the plug is damaged. Please make sure that the connection to
the power source is installed in a way that prevents water to flow along the cable to the direction of the
power plug direction. The installation should be similar to the below mentioned picture. The upward
arc prevents that water drops from getting into the socket.
Technical data
Model Item № Ten ion
(V)
Power con-
umption (W)
Delivery
head (m)
Pump per-
formance (ℓ/h)
Weight
(kg)
CHJ-502 50325 230 6 0.9 500 0.3
CHJ-602 50326 230 8 1.3 600 0.44
CHJ-902 50327 230 16 1.5 900 0.6
© by WilTec Wildanger Technik GmbH Item 50325–50327 Page 4
http://www.WilTec.de
http://www.aoyue.eu 01 2021-1
http://www.teichtip.de
Explo ion view and part li t
№ Name № Name
1Filter basket 11 ir inlet plug
2Filter sponge 12 Engin housing
3Large filter sponge 13 O-ring
4Connector 14 xe
5Controller 15 Rotor
6ir inlet 16 Bearing
7Outlet 17 Pump housing
8ir inlet 18 Guiding
9Supply line 19 Suction cup
10 Valve air inlet
Cleaning
Disconnect the pump from the power supply and remove it from the water. By pulling and
moving carefully separate the engine housing from the impeller chamber. Remove the impeller
and the shaft and clean them with a brush. You can remove resistant debris by putting these
parts in vinegar. Please rinse the parts thoroughly before you put them back into the pump.
The plastic bearings, the ceramic shaft and the like are wear parts. If, despite regular cleaning,
the pump generates significant operating noise after prolonged operation, it may be useful to
replace these parts.
Please clean the sponge regularly in order to avoid an impact on the pump performance.
© by WilTec Wildanger Technik GmbH Item 50325–50327 Page 5
http://www.WilTec.de
http://www.aoyue.eu 01 2021-1
http://www.teichtip.de
Di po al regulation
EU guidelines regarding the disposal of scrap electric appliances (WEEE, 2012/19/EU) were imple-
mented in the law related to electrical and electronic equipment and appliances.
ll WilTec electric devices that fall under the WEEE regulations are labelled with the crossed-out
wheeled waste bin logo. This logo indicates that this electric equipment must not be disposed with the
domestic waste.
The company WilTec Technik GmbH has been registrated in the German registry E R under the
WEEE-registration number DE45283704.
Disposal of used electrical and electronic appliances
(intended for use in the countries of the European
Union and other European countries with a separate
collection system for these appliances).
The logo on the article or on its packaging points out
that this article must not be treated as normal house-
hold waste but must be disposed to a recycling collec-
tion point for electronic and electrical waste equip-
ment. By contributing to the correct disposal of this art-
icle you protect the environment and the health of your
fellow men. Environment and health are threatened by
inappropriate disposal.
Material recycling helps reduce the consumption of raw materials.
dditional information on recycling this article can be provided by your local community, municipal
waste disposal facilities or the store where you purchased the article.
ddress:
WilTec Wildanger Technik GmbH
Königsbenden 12 / 28
D-52249 Eschweiler
Important notice:
The reprint or reproduction, even of excerpts, and any commercial use, even in part of this instructions
manual require the written permission of WilTec Wildanger Technik GmbH.
© by WilTec Wildanger Technik GmbH Item 50325–50327 Page 6
http://www.WilTec.de
http://www.aoyue.eu 01 2021-1
http://www.teichtip.de

This manual suits for next models

5

Other SunSun Water Pump manuals

SunSun CUV-718 User manual

SunSun

SunSun CUV-718 User manual

SunSun CQB 2503 User manual

SunSun

SunSun CQB 2503 User manual

SunSun SuperEco JTP Series User manual

SunSun

SunSun SuperEco JTP Series User manual

SunSun CHL Series User manual

SunSun

SunSun CHL Series User manual

SunSun CUP-129 User manual

SunSun

SunSun CUP-129 User manual

SunSun CUP-807 User manual

SunSun

SunSun CUP-807 User manual

SunSun 50312 User manual

SunSun

SunSun 50312 User manual

SunSun MAX-ECO CPP-5000F User manual

SunSun

SunSun MAX-ECO CPP-5000F User manual

Popular Water Pump manuals by other brands

PPS SuperNOVA Installation, operation & maintenance instructions

PPS

PPS SuperNOVA Installation, operation & maintenance instructions

HNP Mikrosysteme mzr-2961 operating manual

HNP Mikrosysteme

HNP Mikrosysteme mzr-2961 operating manual

Stoelting 219 owner's manual

Stoelting

Stoelting 219 owner's manual

ClimateMaster Tranquility Low-Profile Series Installation operation & maintenance

ClimateMaster

ClimateMaster Tranquility Low-Profile Series Installation operation & maintenance

T.I.P. EXTREMA 400/11 CX Translation of original operating instructions

T.I.P.

T.I.P. EXTREMA 400/11 CX Translation of original operating instructions

Silicon Solar AquaJet-Pro-PUMP1224 installation manual

Silicon Solar

Silicon Solar AquaJet-Pro-PUMP1224 installation manual

Oypla Leisure 4002 user manual

Oypla Leisure

Oypla Leisure 4002 user manual

ALPHA DYNAMIC PUMPS Ruby Black Line 010 Non Metallic Installation, operation and maintenance manual

ALPHA DYNAMIC PUMPS

ALPHA DYNAMIC PUMPS Ruby Black Line 010 Non Metallic Installation, operation and maintenance manual

GORMAN-RUPP PUMPS 2D E.50 1P Installation, operation, and maintenance manual with parts list

GORMAN-RUPP PUMPS

GORMAN-RUPP PUMPS 2D E.50 1P Installation, operation, and maintenance manual with parts list

Praher Plastics Aquastar MP6 installation instructions

Praher Plastics

Praher Plastics Aquastar MP6 installation instructions

Fieldmann FVC 3002 ED user manual

Fieldmann

Fieldmann FVC 3002 ED user manual

Ecolab Elados EDPL V60 user manual

Ecolab

Ecolab Elados EDPL V60 user manual

DeVilbiss 7305P Instruction guide

DeVilbiss

DeVilbiss 7305P Instruction guide

Borger Classic FL Series operating manual

Borger

Borger Classic FL Series operating manual

Oerlikon XM manual

Oerlikon

Oerlikon XM manual

red lion RJS-PREM Series owner's manual

red lion

red lion RJS-PREM Series owner's manual

Becker VXLF 2.200 operating instructions

Becker

Becker VXLF 2.200 operating instructions

KSB CPKO operating instructions

KSB

KSB CPKO operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.