Installation Instructions
SELECT207XL
Programmer
Select 207xl Technical Data
Power supply 230v AC 50Hz.
Ambient temperature Operating 0°C to 35°C
Total Input 6A
Switch Rating 230vAC 6(2)A
Battery type 3v Lithium button Cr2032
Battery back up 30 days(Time & programme)
Wiring For fixed wiring only
Maintenance No user maintenance reqd.
Disconnection class 1B
This unit must be installed by a competent person in accordance with the latest appropriate wiring
regulations.
Pre Installation set-up
Before installing, set the bank of 4 DIP switches
on the back, to configure the unit according to the
chart below.
DIP switches shown in factory default position
Pumped – Allows independent control of CH and
HW.
Gravity – Does not allow CH without HW, but can
Provide HW without CH.
24Hr. - Runs same programme every day
5/2 Day - Allows different ON/OFF times at
weekend
7 Day - Allows different on/off times every day
Locate the back up battery, remove packing and
fit to the back of the unit, observing correct
polarity as marked.
This will ensure times and programme settings
are maintained during temporary power
interruptions.
When unit is first switched on, or when the reset
button is pressed, the status of the DIP switches
is displayed.
Energy saving feature
Sunvics patented ‘De-Latch’ saves energy and
increases the life of 3 port spring return motorised
valves.
All 3 port spring return motorised valves can
remain powered ON in the CH position after the
demand for heating has been satisfied, even if the
boiler and the pump are switched off. It can be left
on all night, using twice as much energy as it
should. The valve will only return from this
‘latched’ position to the HW position after a
demand for HW or HW & CH together. This can
lead to motor burn out, and failure of any make of
3 port spring return motorised valve.
The Select 207 programmer is supplied with a
patented system to prevent this ‘latching’.
Whenever the programme stops calling for CH, it
sends a signal to the valve to fully switch it off.
This will significantly prolong the life of all makes
of 3 port spring return motorised valves and save
energy. The Select 207 is supplied with ‘DE-
LATCH’ activated. (It has no effect on 2 port
valves).
To de-activate the ‘DE-LATCH’, cut the link as
indicated on the back of the programmer before
installing.
INSTALLATION
This unit is compatible with many other
programmers and may be fitted to existing
standard wall plates. Please consult the ‘WIRING
INTERCHANGE GUIDE’ for compatible
programmer types. Some are directly
interchangeable, others will require minor
changes to wiring connections.
Be sure to switch off the mains supply before
starting. Please read all installation instructions
before proceeding.
Ensure that the fixed wiring connections to the
mains supply, is via a fuse rated at not more
6 amps, and a class ‘A’ switch, having a contact
separation of a minimum of 3mm in all poles.
3 on/offs
5/2 da
7 da
gravity
2 on/offs
24Hr
Pum
ed