Superior Electric STABILINE DIN3-165 Series User manual

L1
In Out
N
In Out
F
V
C
M
V
V
F
F
M
M
F
V
C
M
V
V
F
F
M
M
F
V
C
M
V
V
F
F
M
M
2L1L
F
V
C
M
V
V
F
F
M
M
F
V
C
M
V
V
F
F
M
M
L
F
V
C
M
V
V
F
F
M
M
N
2L1L
F
V
C
M
V
V
F
F
M
M
F
V
C
M
V
V
F
F
M
M
3L
F
V
C
M
V
V
F
F
M
M
In Out In Out
In Out
In Out In Out
N
In Out
In Out In Out
L2
In Out
L2
In Out
SPECIFICATIONS
Electrical Specifications
Modes of Protection: L-N; L-G; L-L protectors use MOV
technology and N-G protector use Gas Tube.
Line Voltage Protectors: Multi-redundant protection
circuit (triple stage fault indicators).
Input Power Frequency: 47-64 Hz.
Associated Fusing: DIN3-165 protectors incorporate an
internal thermal disconnect system with time-delayed
Class J,30A-125A over current fuses.
Environmental Specifications
Operating Temperature: -40° C to 85° C (-40° F to 185° F).
Relative Humidity: 5% to 95% non-condensing.
Max. Operating Altitude: 4,000 meters (13,000 feet).
Mechanical Specifications
Enclosure: IP20 enclosures (UL94V0 thermoplastic
housing material).
Mounting: Din Rail 35mm symmetrical.
Connection Method: Screw terminal # 2-10 AWG.
Size (H x W x D): 3.5 x 1.42 x 2.63 inches (90.0 x 36.0 x 67 mm).
Weight (Shipping): 0.80 lbs (0.35 kg).
General Specifications
Standards Compliance and Safety Approvals: Meet UL
1449, 2nd Edition, EN61643-11 (Europe), ANSI/IEEE
C62.41-2002, NF EN 61643-11 (France), VDE0675-6,
CSA-22.2 and CE marked.
Warranty: Ten Years.
STABILINE® Transient Voltage Surge Suppressors
DIN3-165 Series - OWNERS MANUAL
Thank you for purchasing the DIN3-165 Series STABILINE
TransientVoltageSurge Suppressor...anotherSuperior product!!
Expect exceptional performance. The unit is built to the highest
standards for your complete satisfaction.
To assure many years of uninterrupted service, please read this
Owners Manual to familiarize yourself with the operation and
proper installation of the DIN3-165 Series unit.
TYPICAL SERVICE CONFIGURATIONS for Parallel-Connected Method
Contact Factory for addititional configurations
1 Ø, 120 VAC, 2-Wire, w/ground L-N, N-G 1 1
1 Ø, 120/240 VAC, 3-Wire SPLIT-PHASE, w/ground L-N / L-N, N-G 2 1
3 Ø, 208Y/120 VAC, 4-Wire WYE, w/ground L-N / L-N / L-N, N-G 3 1
1 Ø, 220 VAC, 2-Wire, w/ground L-N, N-G 1 1
3 Ø, 380Y/220 VAC, 4-Wire WYE, w/ground L-N / L-N / L-N, N-G 3 1
3 Ø, 220 or 240 VAC, 3-Wire DELTA L-L / L-L / L-L 3 N/A
1 Ø, 277 VAC, 2-Wire, w/ground L-N, N-G 1 1
3 Ø, 480Y/277 VAC, 4-Wire WYE, w/ground L-N / L-N / L-N, N-G 3 1
1 Ø, 480 VAC, 2-Wire, w/grounded neutral L-N, N-G 1 1
3 Ø, 380 or 480 VAC, 3-Wire DELTA L-L / L-L / L-L 3 N/A
DIN3-100-NG1 120, 120/240, 220, 277, 380, 480 VAC Neutral to Ground N-G N/A 1 600 VAC 100 kA 50 kA 800 VAC ----
1500 VAC 1750 VACDIN3-165-480-L1 550 VAC 165 kA 70 kA
DIN3-165-220-L1
150 VAC
330 VAC
C3 Comb
Wave
Surge Performance Specifications
Max Surge
Current Rating
Protector Quantity
Line
Voltage N-G MCOV
900 VAC 950 VAC
70 kA
70 kA
70 kA
165 kA
165 kA
625 VAC
900 VAC 950 VAC
DIN3-165-277-L1
Nominal Surge
Current Rating
UL 1449
SVR Rating
165 kA
DIN3-165-120-L1 500 VAC
STABILINE
Model
Typical
System Voltage / Service Configuration Protection Mode
330 VAC
MODEL NUMBER & Typical System Voltage / Service Configurations
For a minimum of (20) 8 x 20usec surges
UL 1449 2nd Edition, (6kV, 500A 8 x 20usec) Surge Voltage Rating
C3 Combination Wave, 20kV, 8 x 20usec, 10 kA
1
2
3
1 32
DIN3-165 Series STABILINE® Transient Voltage Surge Suppressors are single pole, parallel and/or “in-line” connected, MOV technology
Class I, Category C Surge Protective Devices suitable for use in AC electrical power systems for protection against surge and transient activity.
DIN3-165 Series protectors provide 165 or 100 kA Surge Amp Capacity in a maintenance free, low profile, DIN Rail mountable module. All line
voltage protectors (L-In / L-Out) can also be connected “in-line” and provide for 50A Maximum Continuous Operating Current protection.
1 Ø, 2-Wire, w/ground 1 Ø, 120/240 VAC, 3-Wire
SPLIT-PHASE, w/ground
3 Ø, 4-Wire WYE, w/ground
3 Ø, 3-Wire DELTA
* These INSTRUCTIONS are subject to change
without notice.
Downloaded from Elcodis.com electronic components distributor
©2008 Superior Electric
REMOVE POWER FROM ELECTRICAL SYSTEM PRIOR TO INSTALLATION.
The DIN3-165 protectors are installed/connected in Parallel with the line and the
equipment to be protected.
The DIN3-165 Series unit should be installed down stream of a 200 A maximum fuse
or breaker (see diagram). If pre-existing fuses or breakers are present, then the fusing or
breaker used for the DIN3-165 protector should have a lower rating in order to be properly
coordinated, as per applicable electrical regulatory standards. The Short Circuit current rating
for these DIN3-165 protectors are 25,000 Amps using a 50A Class J time delayed fuse.
The Importance of Correct Installation
THE FOLLOWING IS INTENDED FOR QUALIFIED ELECTRICAL PERSONNEL
ONLY. COMPLETELY READ THESE INSTRUCTIONS BEFORE INSTALLATION. IT
IS THE FINAL RESPONSIBILITY OF THE INSTALLING ELECTRICIAN TO ENSURE
THAT ALL LOCAL CODES AND OTHER APPLICABLE SAFETY/ENVIRONMENTAL
CONDITIONS ARE MET AND THE UNIT IS CORRECTLY INSTALLED.
This manual provides guidelines for the proper installation of DIN3-165 Series units.
Proper product selection and compliance with these guidelines will help your new
suppression system provide years of reliable service. If installer’s are unsure about
the facility’s electrical configuration or have other installation-related questions,
we recommend they consult with a master electrician or other qualified electrical
professional.
Installation
The DIN3-165 protector is a maintenance free device. If the unit is subjected to a
prolonged over-voltage condition, aninternal thermal element willactivate, disconnecting
the DIN3-165 from the line. When the unit is no longer providing protection the window
on the front of the DIN3-165 becomes red and a replacement unit will be required.
Remote Signal
DIN3-165 protectors (except N-G protector) come standard with one remote monitoring
relay with “dry Form C contacts” per module. The contact can be used to drive several
different types of indicators such as a remote light indicator or an audible alarm. The
signal strength is (Vmax:250V rms, Imax: 2A). The connection to the remote signal is
through the screw terminals. Protector DIN3-164-480-L1 is provided with a “Form B dry
contact” per module.
Maintenance
SAVE THESE INSTRUCTIONS!!
28 SPRING LANE • SUITE 3
FARMINGTON, CT 06032 USA
www.superiorelectric.com
213709-236 REV B Printed in USA
Toll-Free (in USA and Canada only)
Telephone
Fax
Customer Service
Product Application
1-800-787-3532
1-800-821-1369
1-800-787-3532, Ext. 70782
1-800-787-3532, Ext. 72058
Telephone and Fax Numbers
Telephone
Fax
Customer Service
Product Application
860-507-2025
860--507-2050
860-507-2025, Ext. 70782
860-507-2025, Ext. 72058
2.63 in (67mm)
3.5in (90mm)
2 in (51mm)
.42 in (11mm)
1.42 in (36mm)
Inches (mm)
Out
In
FF
M
F
ttt
C
VVV
M
MV : Heavy Duty Varistor
F : Thermal Fuse
C : Remote and Signal Contact
t : Thermal Disconnect
M: Monitor (Window)
L
Dimensions
DO NOT INSTALL THE DIN PROTECTOR IF MEASURED VOLTAGE EXCEEDS UNIT
RATINGS.
The DIN3-165 protector MUST BE mounted in an enclosure to assure personnel
safety from exposed terminals. Mechanically mount the DIN3-165 protector utilizing
customer supplied Din-Rail.
Wiring connection between the DIN3-165 protector and protected equipment should
be kept as short as possible. Superior Electric recommends that wire lengths be less
than 20 inches (0.5m). Wire should be straight and should not contain 90 degree
bends. If bends are required, they should be sweeping bends.
Unprotected cables should not be installed in parallel with the protected cables. This
will minimize coupling of inductively induced surges onto unprotected cables.
Internal Protector Schematics
Gas
Tube
Out
In N
Line Voltage Protector Neutral to Ground Protector
Example: 3 Ø, 4-Wire WYE, w/ground service configuration
Connection Methods
N
L2
L1
L3
Delayed RDC Breaker
Fuses
(200 A type gG)
Breaker
(200 A)
To w a r d
Ground
Network
Ground
Total length
of the wires
0-2 ft. (0-0.5m)
<
Protected Installation
N
L2
L1
L3
Disconnection
Indicator
N
L2
L1
L3
Protected Installation
Delayed
RDC Breaker
Fuses
(200 A type gG)
Breaker
(200 A)
To w a r d
Ground
Network
Ground
N
L2
L1
L3
Disconnection
Indicator
Total length
of the wires
0-2 ft. (0-0.5m)
<
Parallel Connection “In-Line” Connection
Downloaded from Elcodis.com electronic components distributor

This manual suits for next models

5

Other Superior Electric Surge Protector manuals

Superior Electric STABILINE PT2 Series User manual

Superior Electric

Superior Electric STABILINE PT2 Series User manual

Superior Electric Stabiline TB1 Series User manual

Superior Electric

Superior Electric Stabiline TB1 Series User manual

Superior Electric STABILINE DIN3-70 Series User manual

Superior Electric

Superior Electric STABILINE DIN3-70 Series User manual

Superior Electric STABILINE DIN2R-40 Series User manual

Superior Electric

Superior Electric STABILINE DIN2R-40 Series User manual

Superior Electric STABILINE CS1 Series User manual

Superior Electric

Superior Electric STABILINE CS1 Series User manual

Popular Surge Protector manuals by other brands

M-system MDK-LC instruction manual

M-system

M-system MDK-LC instruction manual

Oase FM-Master WLAN operating instructions

Oase

Oase FM-Master WLAN operating instructions

INSTROTECH IQ640 Data manual

INSTROTECH

INSTROTECH IQ640 Data manual

Balt Power Tower 27735 Assembly instructions

Balt

Balt Power Tower 27735 Assembly instructions

Dynex DX-S114251 Quick setup guide

Dynex

Dynex DX-S114251 Quick setup guide

Siemens 5SD7418 Series operating instructions

Siemens

Siemens 5SD7418 Series operating instructions

Transparent POWERBANK 6 owner's manual

Transparent

Transparent POWERBANK 6 owner's manual

Panamax MAX 4400 instructions

Panamax

Panamax MAX 4400 instructions

Omron S8M product manual

Omron

Omron S8M product manual

Philips SPP2305WC Specification sheet

Philips

Philips SPP2305WC Specification sheet

Axis T8061 installation guide

Axis

Axis T8061 installation guide

UL GenerLink operating manual

UL

UL GenerLink operating manual

Transtector CPX installation instructions

Transtector

Transtector CPX installation instructions

Liebert 100 - 2 Specification sheet

Liebert

Liebert 100 - 2 Specification sheet

Real-El RS-Protect user manual

Real-El

Real-El RS-Protect user manual

Raycap RSCAC-7239 Series installation instructions

Raycap

Raycap RSCAC-7239 Series installation instructions

Austere VII Series user guide

Austere

Austere VII Series user guide

Moxa Technologies ISD-1100 Series Hardware installation guide

Moxa Technologies

Moxa Technologies ISD-1100 Series Hardware installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.