  9. Superior Electric STABILINE DIN3-70 Series User manual

Superior Electric STABILINE DIN3-70 Series User manual

L1
In Out
N
In Out
F
V
C
M
V
V
F
F
M
M
F
V
C
M
V
V
F
F
M
M
F
V
C
M
V
V
F
F
M
M
2L1L
F
V
C
M
V
V
F
F
M
M
F
V
C
M
V
V
F
F
M
M
L
F
V
C
M
V
V
F
F
M
M
N
2L1L
F
V
C
M
V
V
F
F
M
M
F
V
C
M
V
V
F
F
M
M
3L
F
V
C
M
V
V
F
F
M
M
In Out In Out
In Out
In Out In Out
N
In Out
In Out In Out
L2
In Out
L2
In Out
SPECIFICATIONS
Electrical Specifications
Modes of Protection: L-N; L-G; L-L protectors use MOV
technology and N-G protector use Gas Tube.
Line Voltage Protectors: Multi-redundant protection
circuit (triple stage fault indicators).
Input Power Frequency: 47-64 Hz.
Associated Fusing: DIN3-70 protectors incorporate an
internal thermal disconnect system with time-delayed
Class J,30A-125A over current fuses.
Environmental Specifications
Operating Temperature: -40° C to 85° C (-40° F to 185° F).
Relative Humidity: 5% to 95% non-condensing.
Max. Operating Altitude: 4,000 meters (13,000 feet).
Mechanical Specifications
Enclosure: IP20 enclosures (UL94V0 thermoplastic
housing material).
Mounting: Din Rail 35mm symmetrical.
Connection Method: Screw terminal # 2-10 AWG.
Size (H x W x D): 3.5 x 1.42 x 2.63 inches (90.0 x 36.0 x 67 mm).
Weight (Shipping): 0.80 lbs (0.35 kg).
General Specifications
Standards Compliance and Safety Approvals: Meet UL
1449, 2nd Edition, EN61643-11 (Europe), ANSI/IEEE
C62.41-2002, NF EN 61643-11 (France), VDE0675-6,
CSA-22.2 and CE marked.
Warranty: Ten Years.
STABILINE® Transient Voltage Surge Suppressors
DIN3-70 Series - OWNERS MANUAL
Thank you for purchasing the DIN3-70 Series STABILINE
TransientVoltageSurgeSuppressor...anotherSuperiorproduct!!
Expect exceptional performance. The unit is built to the highest
standards for your complete satisfaction.
To assure many years of uninterrupted service, please read this
Owners Manual to familiarize yourself with the operation and
proper installation of the DIN3-70 Series unit.
TYPICAL SERVICE CONFIGURATIONS for Parallel-Connected Method
Contact Factory for addititional configurations
1 Ø, 120 VAC, 2-Wire, w/ground L-N, N-G 1 1
1 Ø, 120/240 VAC, 3-Wire SPLIT-PHASE, w/ground L-N / L-N, N-G 2 1
3 Ø, 208Y/120 VAC, 4-Wire WYE, w/ground L-N / L-N / L-N, N-G 3 1
1 Ø, 220 VAC, 2-Wire, w/ground L-N, N-G 1 1
3 Ø, 380Y/220 VAC, 4-Wire WYE, w/ground L-N / L-N / L-N, N-G 3 1
3 Ø, 220 or 240 VAC, 3-Wire DELTA L-L / L-L / L-L 3 N/A
1 Ø, 277 VAC, 2-Wire, w/ground L-N, N-G 1 1
3 Ø, 480Y/277 VAC, 4-Wire WYE, w/ground L-N / L-N / L-N, N-G 3 1
DIN3-100-NG1 120, 120/240, 220, 277, 380, 480 VAC Neutral to Ground N-G N/A 1 600 VAC 100 kA 50 kA 800 VAC ----
DIN3-70-277-L1
Nominal Surge
Current Rating
UL 1449
SVR Rating
70 kA
DIN3-70-120-L1 400 VAC
STABILINE
Model
Typical
System Voltage / Service Configuration Protection Mode
330 VAC
C3 Comb
Wave
Surge Performance Specifications
Max Surge
Current Rating
600 VAC 600 VAC
30 kA
30 kA
30 kA
70 kA
70 kA
400 VAC
600 VAC 600 VACDIN3-70-220-L1
150 VAC
330 VAC
Protector Quantity
Line
Voltage N-G MCOV
MODEL NUMBER & Typical System Voltage / Service Configurations
For a minimum of (20) 8 x 20usec surges
UL 1449 2nd Edition, (6kV, 500A 8 x 20usec) Surge Voltage Rating
C3 Combination Wave, 20kV, 8 x 20usec, 10 kA
1
2
3
1 32
DIN3-70 Series STABILINE® Transient Voltage Surge Suppressors are single pole, parallel and/or “in-line” connected, MOV technology
Class I, Category C Surge Protective Devices suitable for use in AC electrical power systems for protection against surge and transient activity.
DIN3-70 Series protectors provide 70 or 100 kA Surge Amp Capacity in a maintenance free, low profile, DIN Rail mountable module. All line
voltage protectors (L-In / L-Out) can also be connected “in-line” and provide for 50A Maximum Continuous Operating Current protection.
1 Ø, 2-Wire, w/ground 1 Ø, 120/240 VAC, 3-Wire
SPLIT-PHASE, w/ground
3 Ø, 4-Wire WYE, w/ground
3 Ø, 3-Wire DELTA
* These INSTRUCTIONS are subject to change
without notice.
Downloaded from Elcodis.com electronic components distributor
©2007 Superior Electric
REMOVE POWER FROM ELECTRICAL SYSTEM PRIOR TO INSTALLATION.
The DIN3-70 protectors are installed/connected in Parallel with the line and the equipment
to be protected.
The DIN3-70 Series unit should be installed down stream of a 200 A maximum fuse
or breaker (see diagram). If pre-existing fuses or breakers are present, then the fusing or
breaker used for the DIN3-70 protector should have a lower rating in order to be properly
coordinated, as per applicable electrical regulatory standards. The Short Circuit current
rating for these DIN3-70 protectors are 25,000 Amps using a 50A Class J time delayed fuse.
The Importance of Correct Installation
THE FOLLOWING IS INTENDED FOR QUALIFIED ELECTRICAL PERSONNEL
ONLY. COMPLETELY READ THESE INSTRUCTIONS BEFORE INSTALLATION. IT
IS THE FINAL RESPONSIBILITY OF THE INSTALLING ELECTRICIAN TO ENSURE
THAT ALL LOCAL CODES AND OTHER APPLICABLE SAFETY/ENVIRONMENTAL
CONDITIONS ARE MET AND THE UNIT IS CORRECTLY INSTALLED.
This manual providesguidelines for the properinstallation of DIN3-70 Seriesunits. Proper
product selection and compliance with these guidelines will help your new suppression
system provide years of reliable service. If installer’s are unsure about the facility’s
electrical configuration or have other installation-related questions, we recommend they
consult with a master electrician or other qualified electrical professional.
Installation
The DIN3-70 protector is a maintenance free device. If the unit is subjected to a
prolonged over-voltage condition, aninternal thermal element will activate,disconnecting
the DIN3-70 from the line. When the unit is no longer providing protection the window
on the front of the DIN3-70 becomes red and a replacement unit will be required.
Remote Signal
DIN3-70 protectors (except N-G protector) come standard with one remote monitoring
relay with “dry Form C contacts” per module. The contact can be used to drive several
different types of indicators such as a remote light indicator or an audible alarm. The
signal strength is (Vmax:250V rms, Imax: 2A). The connection to the remote signal is
through the screw terminals.
Maintenance
SAVE THESE INSTRUCTIONS!!
28 SPRING LANE • SUITE 3
FARMINGTON, CT 06032 USA
www.superiorelectric.com
213709-235 REV A Printed in USA
Toll-Free (in USA and Canada only)
Telephone
Fax
Customer Service
Product Application
1-800-787-3532
1-800-821-1369
1-800-787-3532, Ext. 70782
1-800-787-3532, Ext. 72058
Telephone and Fax Numbers
Telephone
Fax
Customer Service
Product Application
860-507-2025
860--507-2050
860-507-2025, Ext. 70782
860-507-2025, Ext. 72058
2.63 in (67mm)
3.5in (90mm)
2 in (51mm)
.42 in (11mm)
1.42 in (36mm)
Inches (mm)
Out
In
FF
M
F
ttt
C
VVV
M
MV : Heavy Duty Varistor
F : Thermal Fuse
C : Remote and Signal Contact
t : Thermal Disconnect
M: Monitor (Window)
L
Dimensions
DO NOT INSTALL THE DIN PROTECTOR IF MEASURED VOLTAGE EXCEEDS UNIT
RATINGS.
The DIN3-70 protector MUST BE mounted in an enclosure to assure personnel
safety from exposed terminals. Mechanically mount the DIN3-70 protector utilizing
customer supplied Din-Rail.
Wiring connection between the DIN3-70 protector and protected equipment should
be kept as short as possible. Superior Electric recommends that wire lengths be less
than 20 inches (0.5m). Wire should be straight and should not contain 90 degree
bends. If bends are required, they should be sweeping bends.
Unprotected cables should not be installed in parallel with the protected cables. This
will minimize coupling of inductively induced surges onto unprotected cables.
Internal Protector Schematics
Gas
Tube
Out
In N
Line Voltage Protector Neutral to Ground Protector
Example: 3 Ø, 4-Wire WYE, w/ground service configuration
Connection Methods
N
L2
L1
L3
Delayed RDC Breaker
Fuses
(200 A type gG)
Breaker
(200 A)
To w a r d
Ground
Network
Ground
Total length
of the wires
0-2 ft. (0-0.5m)
<
Protected Installation
N
L2
L1
L3
Disconnection
Indicator
N
L2
L1
L3
Protected Installation
Delayed
RDC Breaker
Fuses
(200 A type gG)
Breaker
(200 A)
To w a r d
Ground
Network
Ground
N
L2
L1
L3
Disconnection
Indicator
Total length
of the wires
0-2 ft. (0-0.5m)
<
Parallel Connection “In-Line” Connection
Downloaded from Elcodis.com electronic components distributor

This manual suits for next models

4

Other Superior Electric Surge Protector manuals

Superior Electric STABILINE PT2 Series User manual

Superior Electric

Superior Electric STABILINE PT2 Series User manual

Superior Electric STABILINE CS1 Series User manual

Superior Electric

Superior Electric STABILINE CS1 Series User manual

Superior Electric Stabiline TB1 Series User manual

Superior Electric

Superior Electric Stabiline TB1 Series User manual

Superior Electric STABILINE DIN2R-40 Series User manual

Superior Electric

Superior Electric STABILINE DIN2R-40 Series User manual

Superior Electric STABILINE DIN3-165 Series User manual

Superior Electric

Superior Electric STABILINE DIN3-165 Series User manual

Popular Surge Protector manuals by other brands

QVS PP114M Specification sheet

QVS

QVS PP114M Specification sheet

Philips SPP2304WC Specifications

Philips

Philips SPP2304WC Specifications

Enercell Enercell 61-188 quick start

Enercell

Enercell Enercell 61-188 quick start

Philips SPP7357WC Specifications

Philips

Philips SPP7357WC Specifications

M-system MDP-100T instruction manual

M-system

M-system MDP-100T instruction manual

CyberPower 1085 Specification sheet

CyberPower

CyberPower 1085 Specification sheet

CyberPower B602RC1 user manual

CyberPower

CyberPower B602RC1 user manual

Mercury RC-E5 user manual

Mercury

Mercury RC-E5 user manual

Renkforce 1574788 operating instructions

Renkforce

Renkforce 1574788 operating instructions

Radio Shack 61-2422 owner's manual

Radio Shack

Radio Shack 61-2422 owner's manual

LEGRAND SANUS SA-OWSP60 instruction manual

LEGRAND

LEGRAND SANUS SA-OWSP60 instruction manual

CyberPower 1080 Specification sheet

CyberPower

CyberPower 1080 Specification sheet

Projoy Electric PESP-1000 instructions

Projoy Electric

Projoy Electric PESP-1000 instructions

Assmann DIGITUS RJ45 Quick installation guide

Assmann

Assmann DIGITUS RJ45 Quick installation guide

NewPwr S-FLP Series quick start guide

NewPwr

NewPwr S-FLP Series quick start guide

Leviton 5480 installation instructions

Leviton

Leviton 5480 installation instructions

LIBERTY AV SOLUTIONS DigitaLinx DL-SP installation guide

LIBERTY AV SOLUTIONS

LIBERTY AV SOLUTIONS DigitaLinx DL-SP installation guide

Ilsco SSI SpecPRO CRM 12 Series manual

Ilsco

Ilsco SSI SpecPRO CRM 12 Series manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.