SWT TECH Series Administrator Guide

Safe W a t e r t echnologieS, i n c .
OPERATION & INSTRUCTION MANUAL
TECH SERIES CONTROL VALVES
FILTERS, SOFTENERS, CONDITIONERS
1 INCH TECH SERIES CONTROL VALVE MODEL: WS1
1.25 INCH TECH SERIES CONTROL VALVE MODEL: WS1.25
APRIL 2016

Table of Contents
3. Control Valve Function and Cycles of Operation
3. Table 1. Regeneration Cycles for Softening
4. Table 2. Backwash NORMAL Length Softener Cycle Times in Minutes
4. Table 3. Backwash LONGER Length Softener Cycle Times in Minutes
5. Table 4. Regeneration Cycles Filtering
5. Table 5. Regeneration Filter Cycle Times in Minutes
5. Table 6. Non-Regenerating Filter Cycle Times in Minutes
6. Table 7. DIR/Time Clock Options
7. General Instructions
8. Softener Setup
9. Table 8. Softener and Filter Setting Options
10. Filter Setup
11. Installer Display Settings
12. User Display Settings
12. General Operation
12. Regeneration Mode
12. Manual Regeneration
13. Set Time of Day
13. Power Loss
14. Error Message
14. Diagnostics
15. Valve History
16. Drawings and Part Numbers
16. Front Cover and Drive Assembly
17. WS1 Drive Cap Assembly, Downflow Piston, Upflow Piston, Regenerant Piston, and Spacer Stack Assembly
18. WS1.25 Drive Cap Assembly, Downflow Piston, Upflow Piston, Regenerant Piston, and Spacer Stack Assembly
19. WS1 & WS1.25 Identification

Page 3
Control Valve Function and Cycles of Operation
This glass-filled Noryl 1(or equivalent) fully automatic control valve is designed as the primary control center to direct
and regulate all cycles of a water softener or filter. When the WS1 or WS1.25 control valve is manufactured as a
softener, the control valve can be ordered to perform downflow or upflow regeneration. When the WS1 or WS1.25
control valve is set up as a filter, the control valve can be set to perform downflow regeneration or simply backwash.
The control valve can be set to regenerate on demand (consumption of a predetermined amount of water) and/or as
a time clock (passage of a particular number of days). The control valve can be set so that a softener can meet the
Water Quality Association (WQA) Standard S100 or NSF/ANSI Standard 44 efficiency rating.
* NOTE: It is NOT recommended to change control valves from downflow to upflow brining or vice versa in
the field. The valve bodies for downflow and upflow are unique to the regeneration type and should not be
interchanged. A mismatch of valve body and regeneration piston will result in hard water bypass during service.
The control valve is compatible with a variety of regenerants and resin cleaners. The control valve is capable of
routing the flow of water in the necessary paths to regenerate or backwash water treatment systems. The injector
regulates the flow of brine or other regenerants. The control valve regulates the flow rates for backwashing, rinsing,
and the replenishing of treated water into a regenerant tank, when applicable.
The control valve uses no traditional fasteners (e.g. screws); instead clips, threaded caps and nuts, and snap type
latches are used. Caps and nuts only need to be firmly hand tightened because radial seals are used. Tools required
to service the valve include one small blade screwdriver, one large blade screwdriver, pliers, and a pair of hands. A
plastic wrench is available which eliminates the need for screwdrivers and pliers. Disassembly for servicing takes
much less time than comparable products currently on the market. Control valve installation is made easy because
the distributor tube can be cut 0.5 inch above to 0.5 inch below the top of tank thread. The distributor tube is held in
place by an o-ring seal, and the control valve also has a bayonet lock feature for upper distributor baskets.
The AC adapter power pack comes with a 15 foot power cord and is designed for use with the control valve. The AC
adapter power pack is for dry location use only. The control valve remembers all settings for up to 8 hours if the
power goes out and the battery is not depleted. After 8 hours, the only item that needs to be reset is the time of day;
other values are permanently stored in the nonvolatile memory. If a power loss lasts less than 8 hours and the time
flashes on and off, the time of day should be reset and the non-rechargeable battery should be replaced.
Table 1 (below) shows the order of the cycles when the valve is set up as a softener. When the WS1 or WS1.25
control valve is used as a downflow softener, two backwashes always occur. The WS1.25 control valve may not be
used as an upflow softener. When the WS1 control valve is used as an upflow softener (1 inch only), only one
backwash occurs after brining. The regenerant can refill after the rinse cycle or prefill before regeneration. When the
regenerant prefills before regeneration, the prefill starts two hours before the regeneration time set. During the 2-hour
period in which the brine is being made, treated (softened) water is still available. For example: If a downflow
softener regeneration time is set for 2:00 a.m. with the prefill option selected, then the fill cycle occurs at 12:00 a.m.
and the start of the backwash cycle occurs at 2:00 a.m.
Table 1
Regeneration Cycles for Softening (See above * NOTE)
1. Noryl is a trademark of SABIC Innovative Plastics Company.
WS1 & WS1.25 — Downow
Regenerant Rell After Rinse
WS1 & WS1.25 — Downow
Regenerant Prell
WS1 & WS1.25 — Upow
Regenerant Rell After Rinse
WS1 & WS1.25 — Upow
Regenerant Prell
1st Cycle: Backwash 1st Cycle: Fill / Dissolve 1st Cycle: Regenerate 1st Cycle: Fill / Dissolve
2nd Cycle: Regenerate 2nd Cycle: Backwash 2nd Cycle: Backwash 2nd Cycle: Regenerate
3rd Cycle: Backwash 3rd Cycle: Regenerate 3rd Cycle: Rinse 3rd Cycle: Backwash
4th Cycle: Rinse 4th Cycle: Backwash 4th Cycle: Fill / Dissolve 4th Cycle: Rinse
5th Cycle: Fill / Dissolve 5th Cycle: Rinse 5th Cycle: Service 5th Cycle: Service
6th Cycle: Service 6th Cycle: Service

Page 4
When set up as a softener, the backwash and rinse cycles automatically increase with increasing salt dosage.
Backwashes can be set to be NORMAL or LONGER. The option selected will apply to all backwashes. Tables 2
and 3 (below) show the length of the cycles when the valve is set up as a softener.
Table 2
Backwash NORMAL Length Softener
Cycle Times in Minutes
* These are reference numbers that approximate the amount of salt needed. The actual capacity in grains per pound of salt is used in calculations.
** Total Time does not include Fill Time, which is dependent upon the amount of salt needed. When in the Fill Mode the system is providing treated water.
Table 3
Backwash LONGER Length Softener
Cycle Times in Minutes
* These are reference numbers that approximate the amount of salt needed. The actual capacity in grains per pound of salt is used in calculations.
** Total Time does not include Fill Time, which is dependent upon the amount of salt needed. When in the Fill mode the system is providing treated water.
Table 4 (page 5) shows the order of the cycles when the valve is set up as a filter. When the control valve is used as
a downflow regenerating filter (i.e. both backwash and regeneration), it allows the option to specify one backwash or
two backwashes. Regenerating filters also have the option of having the regenerant refill after the rinse cycle or
prefill before regeneration. If the regenerant prefills before regeneration, the prefill starts two hours before the
regeneration time set. During the 2-hour period in which the regenerant is being made, treated water is still available.
For example: If a downflow filter regeneration time is set for 2:00 a.m. with the prefill option selected, then the fill
cycle occurs at 12:00 a.m. and the start of the backwash cycle occurs at 2:00 a.m. There is only one rinse.
Backwashes can be set to NORMAL or LONGER. The option selected will apply to all backwashes. Tables 5 and 6
(page 5) show the length of the cycles when the valve is set up as a filter.
When the control valve is used as a non-regenerating filter (backwash only), it has the option to specify one
backwash or two backwashes. If two backwashes are specified, two rinses occur. Tables 5 and 6 (page 5) show the
length of the cycles when the valve is set up as a filter. When used as a non-regenerating filter, the downflow piston
must be installed, the regenerant piston removed, injector plugs must be installed in both the DN and UP injector
locations, and the refill elbow must be replaced with a refill port plug.
WS1 & WS1.25 Downow Softener WS1 & WS1.25 Upow Softener
Grains Capacity / Lb. NaCl 6000 to 3501 3500 to 2501 2500 to 1700 6000 to 3501 3500 to 2501 2500 to 1700
Lbs. NaCl / Cu.Ft. Resin * Less than 7.5 7.5 to 12 More than 12 Less than 7.5 7.5 to 12 More than 12
Cycle Time
in Minutes
Backwash Normal 6 8 8 — — —
Regenerate 45 60 75 45 60 75
Backwash Normal 3 8 10 6 10 12
Rinse 3 4 6 3 4 6
Total ** 57 80 99 54 74 93
WS1 & WS1.25 Downow Softener WS1 & WS1.25 Upow Softener
Grains Capacity / Lb. NaCl 6000 to 3501 3500 to 2501 2500 to 1700 6000 to 3501 3500 to 2501 2500 to 1700
Lbs. NaCl / Cu.Ft. Resin * Less than 7.5 7.5 to 12 More than 12 Less than 7.5 7.5 to 12 More than 12
Cycle Time
in Minutes
Backwash Normal 8 10 12 — — —
Regenerate 45 60 75 60 70 80
Backwash Normal 8 10 12 12 14 16
Rinse 4 6 8 5 7 9
Total ** 65 86 107 77 91 105

Page 5
Table 4
Regeneration Cycles Filtering
* Second Backwash is optional
** Second rinse only occurs if “Second Backwash” option is selected.
Table 5
Regenerating Filter
Cycle Times in Minutes
* Total Time does not include Fill Time, which is dependent upon the amount of fill needed. When in the Fill mode the system is providing treated water.
Table 6
Non-Regenerating Filter
Cycle Times in Minutes
The control valve with a water meter can be set for Demand Initiated Regeneration (DIR) only, Time Clock operation
only, or DIR and Time Clock whichever comes first, depending upon the settings selected for Day Override and
Gallon Capacity.2See Table 7 (page 6).
If a control valve does not contain a meter, the valve can only act as a time clock, and Day Override should be set to
any number and Gallon Capacity should be set to “oFF.”
2. See Installer Display Settings Step 3-NA (page 11), Softener Setup Step 6-SS (page 8), and Filter Setup Step 5-FS (page 10) for explanations of Day Override and
Gallon Capacity.
WS1 & WS1.25 Single Backwash WS1 & WS1.25 Double Backwash
NORMAL LONGER NORMAL LONGER
Backwash 14 16 8 12
Regenerate 60 60 60 60
2nd Backwash — — 10 12
Rinse 8 10 8 10
Total * 82 86 86 94
WS1 & WS1.25 Single Backwash WS1 & WS1.25 Double Backwash
NORMAL LONGER NORMAL LONGER
Backwash 14 16 8 12
Regenerate 8 10 6 6
2nd Backwash — — 10 12
Rinse — — 8 10
Total * 22 26 32 40
WS1 & WS1.25 — Downow
Regenerant Rell After Rinse
WS1 & WS1.25 — Downow
Regenerant Prell WS1 & WS1.25 — No Regeneration
1st Cycle: Backwash 1st Cycle: Fill 1st Cycle: Backwash
2nd Cycle: Regenerate 2nd Cycle: Backwash 2nd Cycle: Rinse
3rd Cycle: Second Backwash * 3rd Cycle: Regenerate 3rd Cycle: Second Backwash *
4th Cycle: Rinse 4th Cycle: Second Backwash * 4th Cycle: Second Rinse **
5th Cycle: Fill 5th Cycle: Rinse 5th Cycle: Service
6th Cycle: Service 6th Cycle: Service

Page 6
Table 7
DIR/Time Clock Options
* Day Override and Gallon Capacity can not both be set to “oFF” at the same time.
For DIR Softeners, there are two options for setting the Gallons Capacity. The Gallons Capacity is automatically
calculated if set to “AUTO.” Reserve Capacity is automatically estimated based on water usage if “AUTO” is used.
The other option is to set the Gallons Capacity to a specific number. If a specific number is set, Reserve Capacity is
0 (zero), unless the value is manually set (i.e. the manufacturer intentionally sets the Gallon Capacity number below
the calculated capacity of the system).
The Tech WS1 & WS1.25 Control Valves can also be set to regenerate immediately or at the next regeneration time
by changing the Regeneration Time Option. There are three choices for settings:
1. “NORMAL” means regeneration will occur at the preset regeneration time.
2. “on 0” means regeneration will occur when the Gallons Capacity reaches 0 (zero).
3. “NORMAL” and “on 0” (NORMAL + on 0) means the regeneration will occur at the preset regeneration time
unless the Gallons Capacity reaches 0 (zero). If the Gallons Capacity reaches 0 (zero), the regeneration will
begin 10 minutes after no water usage.
The user can initiate manual regeneration. The user has the option to request the manual regeneration at the
delayed regeneration time or to have the regeneration occur immediately:
1. Pressing and releasing the REGEN button will flash “Regen Today” on the display and the regeneration will occur
at the delayed regeneration time. The user can cancel the request by pressing and releasing the REGEN button.
This method of manually initiating regeneration is not allowed when the system is set to “on 0” (i.e. to
immediately regenerate when the Gallon Capacity reaches zero).
2. Pressing and holding the REGEN button for approximately 3 seconds will immediately start the regeneration.
The user cannot cancel this request, except by resetting the control by pressing NEXT and REGEN buttons
simultaneously for 3 seconds.
A unique feature of this control valve is the ability to display actual water usage for the last 63 days. The values are
initially stored as “----”. This means the value is unknown. As days pass, values are stored as “0” for no flow or the
actual number of gallons. The counting of the gallons starts at the regeneration time. If no regeneration time can be
set (i.e. when the valve is set for immediate regeneration) the counting of gallons starts at 12 a.m. Day 1 is
yesterday, day 2 the day before yesterday, etc. As new values are added, the oldest history disappears.
Another unique feature is that the valve automatically calculates a Reserve Capacity when set up as a softener with
Gallons Capacity set to “AUTO” and the Regeneration Time Option set to “Normal” or “Normal + on 0.” The actual
Reserve Capacity is compared to the Gallons Capacity remaining immediately prior to the preset regeneration time.
A regeneration will occur if the actual Reserve Capacity is less than the Gallons Capacity remaining. The actual
Reserve Capacity is calculated by using the estimated Reserve Capacity and adjusting it up or down for actual
usage.
The estimated Reserve Capacity for a given day of the week is the maximum value stored for the last three non-
trivial water usages (i.e. more than 20 gallons/day) in seven day intervals.
DIR Time Clock Reserve Capacity Softener
Filter Settings *
Regenerant Backwash
Only Day Override Gallon Capacity
Yes — Automatically calculated Yes — — Off Auto
Yes — If desired enter a value less than
estimated capacity Yes Yes Yes Off Any Number
Yes Yes Automatically calculated Yes — — Any Number Auto
Yes Yes If desired enter a value less than
estimated capacity Yes Yes Yes Any Number Any Number
— Yes None Yes Yes Yes Any Number Off

Page 7
General Instructions
The control valve offers multiple procedures that allow the valve to be modified to suit the needs of the installation.
These procedures are:
1. Softener Setup
2. Filter Setup
3. Installer Displays & Settings
4. User Displays & Settings
5. Diagnostics
6. Valve History
These procedures can be accessed in any order. Details on each of the procedures are provided on the following
pages.
At the discretion of the manufacturer, the field technician can access all settings. To “lock out” access to diagnostic
and valve history displays, and modifications to settings except hardness, day override, time of regeneration, and
time of day by anyone but the manufacturer, press , NEXT, , and SET CLOCK in sequence after settings are
made. To “unlock,” so other displays can be viewed and changes can be made, press , NEXT, , and SET
CLOCK in sequence.
When in operation, normal user displays such as time of day, gallons remaining, or days remaining before
regeneration are shown. When stepping through a procedure, if no buttons are pressed within five minutes, the
display returns to a normal user display. Any changes made prior to the five minute time-out are incorporated. The
one exception is the current flow rate display under the diagnostic procedure. The current flow rate display has a
30 minute time-out feature.
To quickly exit Softener Setup, Filter Setup, Installer Display Settings, Diagnostics, or Valve History, press SET
CLOCK. Any changes made prior to the exit are incorporated.
All information in Diagnostics may be reset to 0 (zero) when the valve is moved to a new location. To reset to
0 (zero), press NEXT and buttons simultaneously to go to the Setup screen, and release. Press and
simultaneously to reset diagnostic values to 0 (zero). The screen will return to User Display.
Sometimes it is desirable to have the valve initiate and complete two regenerations within 24 hours and then return
to the preset regeneration procedure. It is possible to do a double regeneration if the control valve is set to
“NORMAL” or “NORMAL + on 0” in Step 9-SS (page 8) or Step 7-FS (page 10). To do a double regeneration:
1. Press the REGEN button once. “REGEN TODAY” will flash on the display.
2. Press and hold the REGEN button for 3 seconds until the valve regeneration initiates.
Once the valve has completed the immediate regeneration, the valve will regenerate one more time at the preset
regeneration time.

Page 8
Step 1-SS
Step 2-SS
Step 3-SS
Step 4-SS
Step 5-SS
Step 6-SS
Step 7-SS
Step 8-SS
Step 9-SS
EXIT SOFTENER SETUP
3. If “oFF” or a number is used, hardness display will not be allowed to be set in Installer Display Settings
(Step 2-NA, page 11). It is suggested that “AUTO” be used in order to insure a proper reserve capacity.
Softener Setup
STEP 1-SS – Press NEXT and buttons simultaneously for 3 seconds. If
screen in Step 2-SS does not appear in 5 seconds, the lock on the valve is
activated. To unlock, press , NEXT, , and SET CLOCK in sequence, then
press NEXT and simultaneously for 3 seconds.
STEP 2-SS – Mode: Choose “SOFTENING” using or buttons. Press NEXT
to go to Step 3-SS. Press REGEN to exit Softener Setup.
STEP 3-SS – Hardness: Enter the ion exchange capacity in grains of hardness
(5,000 to 200,000 grains) as calcium carbonate for the system based on test
data using or buttons. Press NEXT to go to Step 4-SS. Press REGEN to
return to the previous step.
STEP 4-SS – Salt: Enter the pounds of salt per regeneration (0.8 to 117 lbs)
using or buttons. Press NEXT to go to Step 5-SS. Press REGEN to return
to the previous step.
STEP 5-SS – Backwash: Set to “NORMAL” or “LONGER” using or buttons.
See Tables 2 and 3 (page 4) for backwash times. Press NEXT to go to Step 6-SS.
Press REGEN to return to the previous step.
STEP 6-SS – Gallons Capacity: Set gallons capacity using or buttons:
— “AUTO” automatically estimates reserve capacity and automatically
calculates gallons capacity from grains capacity and water hardness;
— “oFF” bases regeneration on Day Override in Step 3-NA (page 11); or
— number of gallons (20 to 50,000 gallons).
See Table 8 (page 9) for more detail.3Press NEXT to go to Step 7-SS. Press
REGEN to return to the previous step.
STEP 7-SS – Refill: Set refill option using or buttons:
— “PoST” to refill the brine tank after the final rinse; or
— “PrE” to refill the brine tank two hours before the regeneration time set.
Press NEXT to go to Step 8-SS. Press REGEN to return to the previous step.
STEP 8-SS – Flow: Set regenerant downflow or upflow using or buttons:
— “dn” if the regenerant is to flow downward through the media; or
— “UP” if the regenerant is to flow upward through the media.
Prior to selecting a regenerant flow direction, verify the correct valve body, main
piston, regenerant piston, and stack are being used, and that the injector or
injector plug(s) are in the correct locations. See Compliance Table (page 17) in
Tech Control Valves Service Manual. Press NEXT to go to Step 9-SS. Press
REGEN to return to the previous step.
STEP 9-SS — Regen Time: Set regeneration time option using or buttons:
— “NORMAL” means regeneration will occur at the preset time;
— “on 0” means regeneration will occur immediately when the gallons capacity
reaches 0 (zero); or
— “NORMAL + on 0” means regeneration will occur at one of the following:
— the preset time when the gallons capacity falls below the reserve, or
when the specified number of days between regenerations is reached,
whichever comes first; or
— after 10 minutes of no water usage when the gallon capacity reaches
0 (zero).
See Table 8 (page 9) for more detail. Press NEXT to exit Softener Setup. Press
REGEN to return to the previous step.

Page 9
Table 8
Softener and Filter Setting Options
* Reserve Capacity estimate is based on history of water usage.
NOTE: Filters should only use the shaded options.
Gallons
Capacity
Regeneration
Time Option
Day
Override Result *
AUTO NORMAL oFF
Reserve capacity automatically estimated.
Regeneration occurs when gallons capacity falls below the reserve capacity at the next
Regen Set Time.
AUTO NORMAL Any
number
Reserve capacity automatically estimated. Regeneration occurs at the next Regen Set
Time when gallons capacity falls below the reserve capacity or the specied number of
days between regenerations is reached.
Any
number NORMAL oFF Reserve capacity not automatically estimated.
Regeneration occurs at the next Regen Set Time when gallons capacity reaches 0.
oFF NORMAL Any
number
Reserve capacity not automatically estimated.
Regeneration occurs at the next Regen Set Time when the specied number of days
between regenerations is reached.
Any
number NORMAL Any
number
Reserve capacity not automatically estimated.
Regeneration occurs at the next Regen Set Time when gallons capacity reaches 0 or the
specied number of days between regenerations is reached.
AUTO on 0 oFF
Reserve capacity not automatically estimated.
Regeneration occurs immediately when gallons capacity reaches 0. Time of regeneration
will not be allowed to be set because regeneration will always occur when gallons capacity
reaches 0.
Any
number on 0 oFF
Reserve capacity not automatically estimated.
Regeneration occurs immediately when gallons capacity reaches 0. Time of regeneration
will not be allowed to be set because regeneration will always occur on 0.
AUTO NORMAL +
on 0 oFF
Reserve capacity automatically estimated.
Regeneration occurs when gallons capacity falls below the reserve capacity at the next
Regen Set Time or regeneration occurs after 10 minutes of no water usage when gallon
capacity reaches 0.
AUTO NORMAL +
on 0
Any
number
Reserve capacity automatically estimated.
Regeneration occurs at the next Regen Set Time when gallons capacity falls below the
reserve capacity or the specied number of days between regenerations is reached or
regeneration occurs after 10 minutes of no water usage when gallon capacity reaches 0.
Any
number
NORMAL +
on 0
Any
number
Reserve capacity not automatically estimated.
Regeneration occurs at the next Regen Set Time when the specied number of days
between regenerations is reached or regeneration occurs after 10 minutes
of no water usage when gallon capacity reaches 0.

Page 10
Step 1-FS
Step 2-FS
Step 3-FS
Step 4-FS
Step 5-FS
Step 6-FS
EXIT FILTER SETUP
Step 7-FS
4. Hardness display will not be allowed to be set in Installer Display Settings (Step 2-NA, page 11).
Filter Setup
STEP 1-FS – Press NEXT and buttons simultaneously for 3 seconds. If
screen in Step 2-FS does not appear in 5 seconds, the lock on the valve is
activated. To unlock, press , NEXT, , and SET CLOCK in sequence, then
press NEXT and simultaneously for 3 seconds.
STEP 2-FS – Mode: Choose “FILTERING” using or buttons. Press NEXT
to go to Step 3-FS. Press REGEN to exit Filter Setup.
STEP 3-FS – Regenerant Fill Volume: Set fill volume using or buttons:
— “oFF” if regenerant is not used (i.e. backwash only); or
— regenerant fill volume (0.1 to 100 gallons—default is 0.8).
Prior to selecting “oFF” or regenerant fill volume, verify the correct valve body,
main piston, regenerant piston, and stack are being used, and that the injector
or injector plug(s) are in the correct locations. See Compliance Table (page 17)
and WS1 & WS1.25 Identification (page 46) in Tech Control Valves Service
Manual. Press NEXT to go to Step 4-FS. Press REGEN to return to the
previous step.
STEP 4-FS – Backwash: Set backwash using or buttons:
— “NORMAL” for one normal backwash (14 minutes);
— “NORMAL 2” for two normal backwashes (8 minutes each);
— “LONGER” for one longer backwash (16 minutes); or
— “LONGER 2” for two longer backwashes (12 minutes each).
See Tables 5 and 6 (page 5) for additional details. Press NEXT to go to Step
5-FS. Press REGEN to return to the previous step.
STEP 5-FS – Gallons Capacity: Set gallons capacity using or buttons:
— “oFF” bases regeneration on Day Override in Step 3N (page 11); or
— number of gallons (20 to 50,100 gallons).
See Table 8 (page 9) for more detail.4Press NEXT to go to Step 6-FS. Press
REGEN to return to the previous step.
STEP 6-FS – Refill: Set refill option using or buttons:
— “PoST” to refill the brine tank after the final rinse; or
— “PrE” to refill the brine tank two hours before the regeneration time set.
If “oFF” is selected in Step 3-FS (above), the display can be left on “PoST” or
“PrE” because no refill occurs. Press NEXT to go to Step 7-FS. Press REGEN to
return to the previous step.
STEP 7-FS – Regen Time: Set regeneration time option using or buttons:
— “NORMAL” means regeneration will occur at the preset time;
— “on 0” means regeneration will occur immediately when the gallons capacity
reaches 0 (zero); or
— “NORMAL + on 0” means regeneration will occur at one of the following:
— the preset time when the specified number of days between
regenerations is reached; or
— after 10 minutes of no water usage when the gallon capacity reaches
0 (zero).
See Table 8 (page 9) for more detail. Press NEXT to exit Filter System Setup.
Press REGEN to return to the previous step. To lock settings press , NEXT,
, and SET CLOCK in sequence.

Page 11
Step 1-NA
Step 4-NA
Step 5-NA
EXIT INSTALLER
DISPLAY SETTINGS
Step 2-NA
Step 3-NA
Installer Display Settings
STEP 1-NA – Press NEXT and simultaneously for 3 seconds.
STEP 2-NA – Hardness: Set the amount of hardness in grains of hardness as
calcium carbonate per gallon using the or buttons. The default is 20 with
value ranges from 1 to 150 in 1 grain increments. Note: The grains per gallon
can be increased if soluble iron needs to be reduced. This display will show “–
nA–” if “FILTER” is selected in Step 2-FS (page 10) or if “AUTO” is not selected
in Step 6-SS (page 8). Press NEXT to go to step 3-NA. Press REGEN to exit
Installer Display Settings.
STEP 3-NA – Day Override: When Gallon Capacity is set to “oFF” in Step 6-SS
(page 8) or Step 5-FS (page 10), Day Override sets the number of days
between regenerations. When Gallon Capacity is set to “AUTO” or to a number,
Day Override sets the maximum number of days between regenerations. Set
Day Override using or buttons:
— number of days between regeneration (1 to 28) – a regeneration initiation
will be called for on that day even if a sufficient number of gallons were not
used to call for a regeneration; or
— “oFF” – regeneration initiation is based solely on gallons used.
Press NEXT to go to step 4-NA. Press REGEN to return to the previous step.
STEP 4-NA – Next Regeneration Time (hour): Set the hour of day for
regeneration using or buttons. AM/PM toggles after 12. The default time is
2:00 a.m. This display will show “REGEN on 0 GAL” if “on 0” is selected in Step
9-SS (page 8) or Step 7-FS (page 10). Press NEXT to go to step 5-NA. Press
REGEN to return to the previous step.
STEP 5-NA – Next Regeneration Time (minutes): Set the minutes of day for
regeneration using or buttons. This display will not be shown if “on 0” is
selected in Step 9-SS (page 8) or Step 7-FS (page 10). Press NEXT to exit
Installer Display Settings. Press REGEN to return to the previous step.
To initiate a manual regeneration immediately, press and hold the REGEN button
for 3 seconds. The system will begin to regenerate immediately. The control
valve may be stepped through the various regeneration cycles by pressing the
REGEN button.

Page 12
User Display Settings
General Operation
When the system is operating, one of two
displays will be shown. Pressing the NEXT
button will alternate between the displays.
One of the displays is always the current time
of day. The second display is one of the
following: days remaining or capacity
remaining. Days remaining is the number of
days left before the system goes through a
regeneration cycle. Capacity remaining is the
number of gallons that will be treated before
the system goes through a regeneration
cycle. The user can scroll between the
displays as desired.
If the system has called for a regeneration that will occur at the preset time of regeneration, the words “REGEN
TODAY” will appear on the display.
When water is being treated (i.e. water is flowing through the system) the word “SOFTENING” or “FILTERING”
flashes on the display if a water meter is installed.
Regeneration Mode
Typically, a system is set to regenerate at a time of low water usage. An example
of a time with low water usage is when a household is asleep. If there is a
demand for water when the system is regenerating, untreated water will be used.
When the system begins to regenerate, the display will change to include information about the step of the
regeneration process and the time remaining for that step to be completed. The system runs through the steps
automatically and will reset itself to provide treated water when the regeneration has been completed.
Manual Regeneration
Sometimes there is a need to regenerate the system
sooner than when the system calls for it, usually referred to
as manual regeneration. There may be a period of heavy
water usage because of guests or a heavy laundry day.
When the regeneration time option is set to “NORMAL” or “NORMAL + on 0,” press and release the REGEN button
to initiate a manual regeneration at the preset delayed regeneration time, The words “REGEN TODAY” will flash on
the display to indicate that the system will regenerate at the preset delayed regeneration time. If the REGEN button
is pressed in error, pressing the button again will cancel the request.
NOTE: If the regeneration time option is set to “on 0” there is no set delayed regeneration time so “REGEN TODAY”
will not activate if the REGEN button is pressed.
To initiate a manual regeneration immediately, press and hold the REGEN button for 3 seconds. The system will
begin to regenerate immediately. The request cannot be cancelled.
NOTE: For softeners, if the brine tank does not contain salt, fill with salt and wait at least 2 hours before regenerating.
OR
REGEN TODAY
will be displayed if
a regeneration is
expected “Tonight.”
REGEN TODAY
will flash if a
regeneration is
expected “Tonight.”

Page 13
Set Time of Day
The user can also set the time of day. Time of day should only need to be set
after power outages lasting more than 8 hours, if the battery has been depleted
and a power outage occurs, or when daylight saving time begins or ends. If a
power outage lasting more than 8 hours occurs, the time of day will flash on and
off which indicates the time of day should be reset. If a power outage lasts less
than 8 hours and the time of day flashes on and off, the time of day should be
reset and the battery replaced.
STEP 1-UD – Press SET CLOCK.
STEP 2-UD – Current Time (hour): Set the hour of the day using or
buttons. AM/PM toggles after 12. Press NEXT to go to Step 3-UD.
STEP 3-UD – Current Time (minutes): Set the minutes of the day using or
buttons. Press NEXT to exit Set Clock. Press REGEN to return to previous step.
Power Loss
If the power goes out, the system will keep time for up to 8 hours or until the battery is depleted. If a power outage of
more than 8 hours occurs, the time of day will flash on and off which indicates the time of day should be reset. The
system will remember the rest. If a power outage lasts less than 8 hours and the time of day flashes on and off, the
non-rechargeable battery should be replaced.
Error Message
If the word “ERROR” and a number are alternately flashing on the display, this
indicates that the valve was not able to function properly. See Troubleshooting &
Error Code Guide for Tech Control Valves for help diagnosing error codes or
contact manufacturer for help.
Step 1-UD
Step 2-UD
Step 3-UD

Page 14
Diagnostics5
STEP 1-DA – Press and simultaneously for 3 seconds. If screen in Step 2-DA does
not appear in 5 seconds, the lock on the valve is activated. To unlock, press , NEXT, ,
and SET CLOCK in sequence, then press NEXT and simultaneously for 3 seconds.
STEP 2-DA – Days, since last regeneration: This display shows the days since the
last regeneration occurred. Press NEXT to go to Step 3-DA. Press REGEN to exit
Diagnostics.
STEP 3-DA – Gallons, since last regeneration: This display shows the number of
gallons that have been treated since the last regeneration. This display will equal 0
(zero) if a water meter is not installed. Press the NEXT to go to Step 4-DA. Press
REGEN to return to the previous step.
STEP 4-DA – Gallons, reserve capacity used for last 7 days: If the valve is set up as
a softener, a meter is installed, and Set Gallons
Capacity is set to “AUTO,” this display shows 0 day (for
today) and flashes the reserve capacity. Pressing the
button will show day 1 (which would be yesterday)
and flashes the reserve capacity used. Pressing the
button again will show day 2 (the day before yesterday)
and the reserve capacity. Keep pressing the button
to show the gallons for days 3, 4, 5, and 6. The
button can be pressed to move backwards in the day
series. Press NEXT at any time to go to Step 5-DA.
Press REGEN to return to the previous step.
STEP 5-DA – Gallons, 63 day usage history: This display shows day 1 (for yesterday)
and flashes the number of gallons treated yesterday. Pressing the button will show
day 2 (which would be the day before yesterday) and flashes the number of gallons
treated on that day. Continue to press the button to show the maximum number of
gallons treated for the last 63 days. This display will show dashes if a water meter is
not installed. Press NEXT at any time to go to Step 6-DA. Press REGEN to return to
the previous step.
STEP 6-DA – Flow Rate, current: Turn the water on at one or more taps in the building.
The flow rate in gallons per minute will be displayed. If flow stops, the value will fall to 0
(zero) in a few seconds. This display will equal 0 (zero) if a water meter is not installed.
Press NEXT to go to Step 7-DA. Press REGEN to return to the previous step.
STEP 7-DA – Flow Rate, maximum last seven days: The maximum flow rate in
gallons per minute that occurred in the last seven days will be displayed. This display
will equal 0 (zero) if a water meter is not installed. Press NEXT to go to Step 8-DA.
Press REGEN to return to the previous step.
STEP 8-DA – Gallons, total used since last reset: The total number of gallons used
since last reset will be displayed. This display will equal 0 (zero) if a water meter is not
installed. Press NEXT to go to Step 9-DA. Press REGEN to return to the previous step.
STEP 9-DA – Days, total number since last reset: The total number of days the
control valve has been in service since last reset will be displayed. Press NEXT to go
to Step 10-DA. Press REGEN to return to the previous step.
STEP 10-DA – Regenerations, total number since last reset: The total number of
regenerations that have occurred since last reset will be displayed. Press NEXT to
exit Diagnostics. Press REGEN to return to the previous step.
Step 1-DA
Step 2-DA
Step 3-DA
Step 6-DA
Step 7-DA
Step 8-DA
Step 9-DA
Step 10-DA
EXIT DIAGNOSTICS
Step 4-DA
Step 5-DA
5. All Diagnostic values can be reset to 0 (zero). See bold type on page 7 for procedure.
Step 1-DA
Step 2-DA
Step 3-DA
Step 6-DA
Step 7-DA
Step 8-DA
Step 9-DA
Step 10-DA
EXIT DIAGNOSTICS
Step 4-DA
Step 5-DA

Page 15
Valve History
STEP 1-VH – Press and simultaneously for 3 seconds and release. Then
press and simultaneously again and release. If screen in Step 2-VH does
not appear in 5 seconds, the lock on the valve is activated. To unlock, press ,
NEXT, , and SET CLOCK in sequence, then press and simultaneously
for 3 seconds and release. Then press and simultaneously again and
release.
STEP 2-VH – Software Version: This display shows the software version of the
valve. Press NEXT to go to Step 3-VH. Press REGEN to exit Valve History.
STEP 3-VH
6 – Flow Rate, maximum since start-up: This display shows the
maximum flow rate in gallons per minute that has occurred since start-up. This
display will equal 0 (zero) if a water meter is not installed. Press NEXT to go to
Step 4-VH. Press REGEN to return to the previous step.
STEP 4-VH – Gallons, total used since start-up: This display shows the total
gallons treated since start-up. This display will equal 0 (zero) if a water meter is
not installed. Press NEXT to go to Step 5-VH. Press REGEN to return to the
previous step.
STEP 5-VH – Days, total since start-up: This display shows the total days since
start-up. Press NEXT to go to Step 6-VH. Press REGEN to return to the
previous step.
STEP 6-VH – Regenerations, total number since start-up: This display shows
the total number of regenerations that have occurred since start-up. Press NEXT
to go to Step 7-VH. Press REGEN to return to the previous step.
STEP 7-VH – Error Log: This display shows a history of the last 10 errors
generated by the control during operation. Press the or buttons to review
each error recorded. Press NEXT to exit Valve History. Press REGEN to return
to the previous step.
Step 1-VH
Step 2-VH
Step 3-VH
Step 4-VH
Step 5-VH
Step 6-VH
EXIT VALVE HISTORY
Step 7-VH
6. Values in Steps 3-VH through 7-VH cannot be reset.

Page 16
Front Cover and Drive Assembly
* Drawing Number Parts 2 through 6 may be purchased as a complete assembly: Part No. LC-V3002, WS1 Drive Assembly.
4
1
6
3
2
5
Battery replacement is
3 Volt Lithium Coin Cell
Type 2032.
Correct
Battery
Orientation
BATTERY FULLY SEATED
When replacing the battery, align
positives and push down to fully seat.
AC Adapter US International
Supply Voltage 120 VAC 230 VAC
Supply Frequency 60 Hz 50 Hz
Output Voltage 12 VAC 12 VAC
Output Current 500 mA 500 mA
Drawing No. Part No. Description Quantity
1 LC-V3175-01 WS1 Front Cover Assembly 1
* LC-V3002 * WS1 Drive Assembly 1
2 LC-V3107-01 WS1 Motor 1
3 LC-V3106-01 WS1 Drive Bracket and Spring Clip 1
4 LC-V3108-10BOARD WS1 PC Board XMEGA Replace 1
5 LC-V3110 WS1 Drive Reducing Gear 12 x 36 3
6 LC-V3109 WS1 Drive Gear Cover 1
Not Shown
LC-V3186 WS1 AC Adapter 120V-12V 1
LC-V3186EU WS1 AC Adapter 220-240V-12V EU 1
LC-V3186UK WS1 AC Adapter 220-240V-12V UK 1
LC-V3186-01 WS1 AC Adapter Cord Only 1

Page 17
WS1 Drive Cap Assembly, Downflow Piston, Upflow Piston, Regenerant Piston, and Spacer Stack Assembly
* P/N: LC-V3011 is labeled with “DN” and P/N: LC-V3011-01 is labeled with “UP.”
NOTE: The regenerant piston is not used in backwash only applications.
6
2
4b
4a
5
1
3
7
8
Black Plug
Drawing No. Part No. Description Quantity
1 LC-V3005-02 WS1 Spacer Stack Assembly 1
2 LC-V3004 Drive Cap Assembly 1
3 LC-V3178 WS1 Drive Backplate 1
4a LC-V3011 * WS1 Piston Downow Assembly 1
4b LC-V3011-01 * WS1 Piston Upow Assembly 1
5 LC-V3174 WS1 Regenerant Piston 1
6 LC-V3135 O-ring 228 1
7 LC-V3180 O-ring 337 1
8 LC-V3105 O-ring 215 (Distributor Tube) 1
Not Shown
LC-V3001 WS1 Body Downow Assembly 1
LC-V3001-02 WS1 Mixing Valve Body Downow Assembly 1
LC-V3001UP WS1 Body Upow Assembly 1
LC-V3001-02UP WS1 Mixing Valve Body Upow Assembly 1

Page 18
WS1.25 Drive Cap Assembly, Downflow Piston, Upflow Piston, Regenerant Piston, & Spacer Stack Assembly
Grey Plug on all
WS1.25 bodies
*Grey Ring
*Grey Distributor
O-ring retainer
* Only for valves that have a
32mm Distributor Tube Opening.
NOTE: The regenerant piston is not used in backwash only applications.
Drawing No. Part No. Description Quantity
1a LC-V3430-01 WS1.5 Spacer Stack Assembly 1
1b LC-V3005-02 WS1 Spacer Stack Assembly 1
2 LC-V3004 Drive Cap Assembly 1
3 LC-V3178 WS1 Drive Backplate 1
4a LC-V3407 WS1.5 Piston Downow Assembly 1
4b LC-V3011-01 WS1 Piston Upow Assembly 1
5 LC-V3174 WS1 Regenerant Piston 1
6 LC-V3135 O-ring 228 1
7 LC-V3180 O-ring 337 1
8
LC-V3358 O-ring 219
(Distributor Tube Opening 1.32 inch) 1
LC-V3357 O-ring 218
(Distributor Tube Opening 32mm) 1
Not Shown
LC-V3020 WS1.25 Body Downow Assembly
(Distributor Tube Opening 1.32 inch) 1
LC-V3020-01 WS1.25 Mixing Valve Body Downow Assembly
(Distributor Tube Opening 1.32 inch) 1
LC-V3020-02 WS1.25 Body Downow Assembly
(Distributor Tube Opening 32mm) 1
LC-V3020-03 WS1.25 Mixing Valve Body Downow Assembly
(Distributor Tube Opening 32mm) 1
LC-V3020UP WS1.25 Body Upow Assembly
(Distributor Tube Opening 1.32 inch) 1
LC-V3020-02UP WS1.25 Body Upow Assembly
(Distributor Tube Opening 32mm) 1

Page 19
WS1 & WS1.25 Identification
WS1 with 1.050 inch Distributor Tube Opening Identification
WS1.25 with 1.32 inch Distributor Tube Opening Identification
WS1.25 with 32mm Distributor Tube Opening Identification
1.25 inch
Gray Plug
NOTE: The WS1 downflow piston is a solid amber color.
The WS1 upflow piston is black and amber.
NOTE: The WS1 downflow piston is a solid amber color.
The WS1 upflow piston is black and amber.
1.25 inch
1.5 inch
Spacer Color:
Black
Spacer Color:
Gray
1.5 inch
1.25 inch
Black Plug
Spacer Color: Gray
1.25 inch
DOWNFLOW & BACKWASH UPFLOW
1.25 inch
Gray Plug
Gray Ring
Gray Distributor O-ring Retainer NOTE: The WS1 downflow piston is a solid amber color.
The WS1 upflow piston is black and amber.
1.25 inch
1.5 inch
Spacer Color:
Black
Spacer Color:
Gray
1.5 inch
DOWNFLOW & BACKWASH UPFLOW

SAFE WATER TECHNOLOGIES, INC.
996 BLUFF CITY BOULEVARD, ELGIN, IL 60120 USA
TELEPHONE 847 888 6900 • FACSIMILE 847 888 6924
E MAIL: info@swtwater.com • WEB SITE: www.swtwater.com
FORM TECH-MANUAL
EFFECTIVE
APRIL 2016
Other manuals for TECH Series
1
This manual suits for next models
2
Table of contents
Popular Controllers manuals by other brands

Baldor
Baldor VS1GV21-1B Installation & operating manual

Johnson Controls
Johnson Controls Joventa DMS1.1 installation instructions

Truma
Truma SecuMotion Operating instructions & installation instructions

Tridonic
Tridonic DALI XC G3 CWM 30 DA2 Installation

TAC
TAC 2413 Handbook

Marshall Excelsior
Marshall Excelsior MEGR-253 Installation and operation instructions