Sym SV Series User manual

CAT.12012E-S
SV series
3, 5-port Solenoid Valve /Pilot Type
SV
series
www.sym21.com
Wide range of port sizes and body sizes (M5~Rc(PT)3/4)
Various products small through large
Superior ow features and high reliability
Highly polished spool of one molding seal type
Low power consumption and
simple maintenance
Lowered power consumption design (1.8W DC) and
non-lubrication of all lines
Various kinds of
wire distributing type
Lead wire, DIN terminal, Plug connector type
All air system
All of 3, 5-port air pilot valves available
Wide range of port sizes and body sizes [M5~Rc(PT)3/4]: Various products small through large Super ow features and high reliability: Highly polished spool of one molding seal type

SV50 series SV100 series
SV200 series SV300 series
INDEX
Safety ...................................................................................
Precautions .......................................................................
Model selection ............................................................
Driving speed chart of cylinder ........................
SV50 series ................................................................
SV100 series ..............................................................
SV200 series .............................................................
SV300 series ..............................................................
4
5
10
10
11
16
21
24
5-port Solenoid Valve [p.11~p.32]
2

Hand Valve Manifold Block
3-port Valve
SV50M, 100M SV200M, 300M
INDEX
SV400 series ..................................................................
SV600 series ..................................................................
SV400 series SV600 series
27
30
5-port Solenoid Valve [p.11~p.32]
Solenoid /Air Operated Valve ..................................
36
3-port Valve [p.36~ p.39]
SV50M, SV100M ............................................................
SV200M, SV300M ........................................................
SV400M, SV600M .........................................................
33
34
35
5-port Air Operated Valve [p.33~p.35]
Hand Valve .........................................................................
Manifold Block ................................................................
40
42
Hand Valve, Manifold Block [p.40~p.43]
3

Caution
PRECAUTION
Be sure to read before handling.
These safety instructions are intended to prevent a hazardous situation and/or equipment damage. These instructions indicate the level
of potential hazard by a label of Caution, Warning, or Danger.
To ensure safety, be sure to observe ISO44141), KS B 63762) and other safety regulations.
Caution Operator error could result in injury or equipment damage.
Warning Operator error could result in serious injury or loss of life.
Danger In extreme conditions, this could result in serious injury or loss of life.
1) ISO 4414: Pneumatic Fluid Power-Recommendations for the application of equipment to transmission and control systems.
2) KS B 6376: General Rules for Pneumatic System
1. The pneumatic equipment shall be selected by pneumatic system designers or professionals.
The person who decides specications has a responsibility for the performance and safety.
2. Only trained person should operate pneumatically operated machinery and equipment.
Compressed air can be dangerous if an operator is unfamiliar with it.
Assembly, handling or repair of pneumatic systems should be performed by a trained and experienced operator.
3. Don't remove components until safety is conrmed.
1) Inspection of machinery and equipment should only be performed after conrmation of safe locked-out control
positions.
2) When equipment is to be removed, conrm the safety process as mentioned above. Cut the supply pressure for this
equipment and exhaust all residual compressed air in the system.
3) When restarting, take measures to prevent shooting-out of cylinder piston rod, etc.
4. Take care if the product is to be used in any of the following conditions.
Please feel free to contact us if you have any questions.
1) Conditions and environments beyond the given Specications, or if product is used outdoors.
2) Installation on equipment in conjunction with food and beverages, medical equipment, vehicles, nuclear energy,
railway, airplane, emergency stop circuits, press clutches, brake equipment or safety equipment.
3) An application requiring special safety.
4

Valve Operation
1. Actuator drive
Take appropriate measures to prevent potential danger caused by
actuator operation when an actuator is to be driven using a solenoid
valve.
2. Intermediate stopping
Accurate stop of the piston in a predetermined position is not possible
due to the compressibility of air when a 3-positon closed center valve
is used to stop a cylinder at a intermediate position.
Furthermore, it may not be possible to hold a stopped position for an
extended length of time since valves and cylinders are not guaranteed
for zero air leakage.
3. Effect of back pressure
You need to be careful when using valves on a manifold because
actuator malfunction due to back pressure may occur.
Your special attention should be taken when using a 3-postion
exhaust center valve or driving a single acting cylinder.
Implement countermeasures such as the use of an individual exhaust
spacer assembly when there is a danger of back pressure.
4. Since valves are subjected to air leakage, they cannot be used
for applications such as holding pressure.
5. Can't be used as an emergency shutoff valve, etc.
6. Release of residual pressure
Provide residual pressure lease function for maintenance purposes.
Special consideration should be given to the release of residual
pressure between the valve and cylinder in case of a 3-position
closed center type valve.
Installation
1. Momentary energization
If a double solenoid valve will be operated with momentary
energization, it should be energized for at least 0.1 second.
2. Leakage voltage
1) Residual leakage voltage of DC coil must be or less than 2%
1. Conrm the Specications.
Don’t operate at pressures or temperatures beyond the range of
specications because this can cause damage or malfunction.
PRECAUTION: Valve
Be sure to read before handling.
Air Supply
1. Use clean air
Use clean air which doesn't contain chemicals, synthetic oils
containing organic solvents, salts or corrosive gases etc., because
this can cause damage or malfunction.
1. Filteration to 5µm is recommended.
2. Large quantity of drainage may cause incorrect operation of pneu-
matic products as well as environmental contamination. Please
control drainage. You can use the lter with auto drainage in case
of difculty.
3. Please install a mist separator when there is a large amount of
carbon power from the compressor.
Warning Warning
Caution
Environment
1. Keep away from corrosive gas, chemical solutions, sea water, rain
and steam.
2. Avoid using in an explosive atmosphere.
3. Don't use in locations subject to vibration or impact.
4. Avoid direct sunlight.
5. Shield radiated heat generated by nearby heat sources.
6. Use a protective cover when installed in a place where a drop of
water or oil will splash momentarily.
7. Please install a silencer on the exhaust port in a dusty place.
Warning
Caution
Caution
Lubrication
1. No further lubrication is required because valves are prelubricated.
2. Please use turbine oil ( ISO VG32 or equivalent to ) if lubricant is
required. Once lubrication is applied, it must be continued because
the original lubricant may be eliminated.
Caution
5

PRECAUTION: Valve
Be sure to read before handling.
Piping
Low temperature operation
1. Before piping is connected, remove chips, cutting oil and other debris
form inside the pipe.
2. When using the Teon tape, ensure that about 1.5~2 threads are left.
3. When using 3-position closed center type, make sure piping leakage
does not occur between valve and cylinder.
4. Clamping torque
Port size Appropriate clamping torque N·m (kgf·cm)
M5 1.5~2 (15~20)
Rc(PT) 1/8 7~9 (70~90)
Rc(PT) 1/4 12~14 (120~140)
Rc(PT) 3/8 22~24 (220~240)
Rc(PT) 1/2 28~30 (280~300)
Rc(PT) 3/4 28~30 (280~300)
Rc(PT) 1 36~38 (360~380)
Using 3-port valve
Maintenance
Avoid ambient temperatures outside the range prescribed in the
Specications. At low temperatures, appropriate measures should be
taken to avoid solidication of freezing of drainage and moisture, etc.
If you block one side of valve port (A, B) with plug, you can use the
valve as 3-port valve with N.O. (Normally Open) or N.C. (Normally
Closed) type.
It is convenient when you need 3-port valve in the manifold blocks.
1. Drainage removal
Remove drainage regularly from air lter.
1. When equipment is removed, rst conrm that measures are in place
to prevent dripping of work pieces and run-away of equipment, etc.
Then cut the supply pressure and power, and exhaust all compressed
air from the system using its residual pressure release function.
When the equipment is to be started again after remounting or
replacement, rst conrm that measures are in place to prevent
lurching of actuators, etc., and then conrm that the equipment is
operating normally.
2. Although don't use frequently, operate the valve regularly to prevent
malfunction.
when switch is OFF.
2) When using a C-R element, there might be a chance to increase
the leakage voltage.
3. Low temperature operation
Avoid ambient temperatures outside the range prescribed in the
Specications. At low temperatures, appropriate measures should be
taken to avoid solidication of freezing of drainage and moisture, etc.
4. Operation for air blowing
You should use external pilot type or direct solenoid operated type
when using solenoid valves for air blowing.Also, supply compressed
air within the pressure range prescribed in the specications,
especially for an external pilot type.
5. Mounting
In case of a single solenoid valve, the mounting orientation is
unrestricted. Double solenoid or 3-posiotn valves should be
mounted so that the spool is horizontal. Mount valves so that the
spool is at a right angle to the direction of vibration in a place where
vibration or shock exists.
Plug position B port A port
Conguration N.C. N.O.
Solenoid
Single
Double
R1
R2P
B A
(
X
)
PLUG
(
X
)
PLUG
(X) PLUG (X) PLUG
R1
R2P
B A
R1
R2P
B A
R1
R2P
B A
Wrappinjg
direction
Teon type
2 threads to be
left exposed
Caution
Caution
Caution
Caution
Warning
6

SOL. SOL.
SOL. Z.D A.C
Z.D A.C D.CD
D
-
+
LED
LED
R
R
LED R
A.C
A.C D.C
-
+
SOL.
SOL.
SOL.
LED
R
LED
R
LED
R
Lamp and surge voltage suppression Power supply time
Classication by the existence of noise suppressor
1. Do not make a megger test between lead wires.
2. 12 and 24 VDC solenoids will not shortout even with wrong
polarity. However, solenoids with surge suppression will not
operate.
3. Single solenoid
If circuit current leakage is experienced, the valve may not turn
off. Ensure that current leakage is below the maximum allowable
leak rate.
4. Double solenoid
Do not apply power to both solenoids simultaneously. The valves
may be put into a neutral state.
Plug connector type
(For SV 50, 100 series)
DIN terminal type
(For all SV series)
When using a double solenoid type with momentary power source,
make sure the power supply time more than 0.1 second.
Solenoid with noise suppressor is eligible for interface of CPU, PC, and
micom etc. because it has a element suppressing the max. voltage
reverse.
1. Surge wave with diode (only for DC)
(Max. voltage reverse of diode 1,000V)
Standard with Diode
2. Surge wave with varistor
Standard with Varistor
D.S.O
A'
DC 24V
A
140V
DC 24V
Max. voltage reverse
: 1,000V
Effective current
: 1A
A'
D.S.O
A
D
ON OFF ON OFF
D.S.O
AC220
A'
D.S.O
AC220
A'
A
600V
msec
2.5 311V
A
8.8
msec
with lamp (PL)
with lamp (DL)
with lamp & surge suppression (PS)
with lamp & surge suppression (DS)
with lamp & surge suppression (PS)
with lamp & surge suppression (DS)
AC
AC
DC
DC
Caution
PRECAUTION: SV series
Be sure to read before handling.
Warning
Warning
Leakage voltage
1. For the leakage current, residual leakage voltage of AC coil must be
less than 20% of the rated voltage, and that of DC coil must be less
than 3% when switch is off.
Warning
7

DIN Terminal
1. Wiring
Unloosen cover mounting screw and separate terminal block from
terminal cover with a small tool. Insert lead wire into terminal
block through gland nut and x cable-xing screws tightly.
2. Outside diameter of applicable lead wire
O.D. of applicable lead wire: Ø6~Ø7
(Ref.) 2 or 3 strands of 0.75mm2 equivalent to KSC 3304
You can change the way lead wire is coming out by turning the cover 180° in
Terminal Block.
Gasket
Turminal block
Turminal cover
Cable-xing screw Gland nut
Cable gasket
Cover mounting
screw
Washer
2 1
Outside diameter of cord:
Ø4~Ø6
Outside diameter of cord:
Ø6~Ø7
Solenoid terminal order is shown as above. 1 indicates + of power supply and
2 indicates – of that.
2. When using a C-R element, there might be a chance to increase the
leakage voltage.
Leakage current
Valve
Leakage voltage
Power source
C-R element
Terminal
Plug Connector
1. Attaching and removing connector
Hold connector between thumb and forenger and push connector
onto pins. Push until lever claw engages pins.
To remove connector, squeeze lever and connector between thumb
and forenger and pull connector off pins.
Connector cover
Socket
Lever
Pins
Connector
Polarity indication (DC)
Lead wire
DC coil / Red, Black
2. Mounting and dismounting socket from connect
Push socket with lead wire into connector until socket hook is en-
gaged. Lightly pull lead wire to ensure proper engagement.
To remove lead wire and socket, pull out lead wire , While pushing
down hook with a small tool, pull out lead wire.
Socket
Connector
Lead wireHook
PRECAUTION: SV series
Be sure to read before handling.
Warning
Warning
There is a built-in protection circuit in static relay.
8

www.sym21.com
SV series
3,5-port Solenoid Valve /Pilot Type

SV
Decision on model
• Cylinder I.D.
(inside diameter)
• Driving speed
• Load factor
Selection of
actuator
Refer to max. driving speed chart for details
This chart only be used as a reference because cylinder speed will vary depending on the connecting pipe work.
Series
Port size
Cylinder speed
(mm / s)
Inside diameter of cylinder (mm)
Ø10 Ø20 Ø32 Ø40 Ø50 Ø63 Ø80 Ø100 Ø125 Ø140 Ø160 Ø180 Ø200 Ø250 Ø300
Effective
area
SV50
M5 -
-
3.6 mm2
(Cv 0.2) -
SV100
Rc(PT) 1/8 250
500
9.5 mm2
(Cv 0.53) 750
SV200
Rc(PT) 1/4 250
500
18 mm2
(Cv 1.0) 750
SV300
Rc(PT) 3/8 250
500
45 mm2
(Cv 2.5) 750
SV400
Rc(PT) 1/2 250
500
80 mm2
(Cv 4.44) 750
SV600
Rc(PT) 3/4 250
500
90 mm2
(Cv 5.0) 750
How to Select Solenoid Valve
Driving speed Chart of Cylinder
• High frequency
• Long life
• Stability of response
• Non-lubrication
Selection of valve
series from cylinder
driving speed chart
• Maintenance
• Location
• Easiness of operation
Use of manifold
• Performance of machine
• Safety
Number of
solenoid position
• Applicable voltage
• Lead wire type
• Plug connector type
• DIN terminal type
Choice of voltage
& electrical entry
Body PortedBase Mounted
10

SV50 series
5-port Pilot Type /Elastic Seal Body Ported
SV51
SV52
SV53
SV54
SV55
(Port size: M5)
(Closed center)
(Port size: M5)
(Exhaust center)
(Pressure center)
5-PORT /2-POSITION
5-PORT /3-POSITION
SV 5 21 L
-
●
PORT SIZE (M5)
•
Width 15.5 mm
•
Large ow capacity - (Cv0.2)
Effective area 3.6 mm2
•
Low power consumption - 1.7W (DC)
•
Various electrical entries
■
SPECIFICATIONS
MODEL
SV51 SV52 SV53 SV54 SV55
Fluid Air or Inert Gases
Pressure range (kgf/cm2)
0.15~0.7 (1.5~7.1)
0.1~0.7 (1.0~7.1) 0.2~0.7 (2.0~7.1)
Effective area (mm2(Cv)) 3.6 (0.2) 3.2 (0.18)
Ambient and media temp. Max. 50°C
Response time (5kgf/cm2)20 ms or less 35 ms or less
Max. Cycles/Second 10 C/S 3 C/S
Lubrication Not required
Manual override operation Non-locking push type
Shock/Vibration resistance 30G / 5G (8.3~2,000 Hz)
Protective structure Dust-proof
Coil rated voltage AC 50 / 60 Hz 110V, 220V DC 12V, 24V
Allowable voltage tolerance -15%~+10% of rated voltage
Coil insulation Class B or equivalent (130°C)
Apparent
power AC
Starting 4.5 VA (50 Hz), 4.2 VA (60 Hz)
Holding 3.0 VA (50 Hz), 2.6 VA (60 Hz)
Power
consumption DC 1.7W
Weight (kg) 0.07 0.11 0.12 0.12 0.12
Surge suppressor AC: Varistor, DC: Diode
Indicator lamp LED
■
HOW TO ORDER
B
A
R1 R2P
AB
R1 P R2
R2PR1
B
A
R1 P R2
AB
R2
B
PR1
A
●
ELECTRICAL ENTRY
L
Without sub-base
PL
Plug connector with lamp
PS
Plug connector with lamp & surge suppressor
D
DIN terminal
DL
DIN terminal with lamp
DS
DIN terminal with lamp & surge suppressor
Only PS types are available for plug connector for DC.
● COIL RATED VOLTAGE
●
CONFIGURATION
1
AC 110V
2
AC 220V
3
DC 12V
4
DC 24V
1
Single solenoid
2
Double solenoid
3
Closed center
4
Exhaust center
5
Pressure center
11

57 1 4 2 3 6
1 4 2 3 6
8
8
1 4 2 3 6
8
PE R1 P PE
R2
A B
R1 P PE
R2
A B
R1 P PE
R2
A B
PE
No. Description Material No. Description Material
BODY ADC-12 END COVER PLASTIC
PISTON PLATE POLYACETAL O-RING NBR
PISTON POLYACETAL SPRING SUS
SPOOL Al·NBR COIL ASS'Y
SV50 series
■
CONSTRUCTION /PARTS
2-position Single Solenoid
2-position Double Solenoid
3-position Double Solenoid
12

5
11
10
19
47 69
Manual
(Push type)
18.5
20
11
300
(Lead wire)
77
42.5
21 5-M5X0.8
M5X0.8
(Port P.E.)
2-Ø2.6
2-Ø2.6
23
3
15.5
85 300
(Lead wire)
25.5
31.5
83.5 MAX.10
45.5
53
PG.7
23
~
=
~
=
R1 P
R2
AB
P.E
SV50 series
■
DIMENSIONS /2-POSITION SINGLE
SV51
- PL/PS
Plug Connector (PL, PS)
SV51
- D/DL/DS
DIN Terminal (D, DL, DS)
SV51
- L
Lead Wire (L)
13

10
19
57
101
11
117.5
48
21 5-M5X0.8
M5X0.8
133
130.0
20
3
300
25.5
31.5
PG.7
45.5
53
MAX.10
Manual
(Push type)
(Lead wire)
(Port P.E.)
15.5
23
300
(Lead wire)
EP
~
=
~
=
AB
R1 P
R2
P.E
2-Ø2.6
2-Ø2.6
SV50 series
■
DIMENSIONS /2-POSITION DOUBLE
SV52
- L
Lead Wire (L)
SV52
- PL/PS
Plug Connector (PL, PS)
SV52
- D/DL/DS
DIN Terminal (D, DL, DS)
14

77 66.5
25.5
31.5
300
75.5 PG.7
MAX.10
45.5
53
(Lead wire)
65
~
=
10
19
39 28.5
61 50.5
11
128
20
3
21 5-M5X0.8
34.5 24 M5X0.8
Manual
(Push type)
(Port P.E.)
15.5
23
300
(Lead wire)
EP
~
=
R1 P
R2
AB
P.E
2-Ø2.6
2-Ø2.6
SV50 series
■
DIMENSIONS /3-POSITION CLOSED CENTER, EXHAUST CENTER, PRESSURE CENTER
SV53/54/55
- L
Lead Wire (L)
SV53/54/55
- PL/PS
Plug Connector (PL, PS)
SV53/54/55
- D/DL/DS
DIN Terminal (D, DL, DS)
15

SV100 series
5-port Pilot Type /Elastic Seal
SV110
SV120
SV130
SV140
SV150
(Port size: PT 1/8)
(Closed center)
(Port size: PT 1/8)
(Exhaust center)
(Pressure center)
5-PORT /2-POSITION
5-PORT /3-POSITION
●
ELECTRICAL ENTRY
●
PORT SIZE RC(PT) 1/8
L
Without sub-base
PL
Plug connector with lamp
PS
Plug connector with lamp & surge suppressor
D
DIN terminal
DL
DIN terminal with lamp
DS
DIN terminal with lamp & surge suppressor
Only PS types are available for plug connector for DC.
•
Width 18 mm
•
Large ow capacity - (Cv0.53)
Effective area 9.5 mm2
•
Low power consumption - 1.7W (DC)
•
Various electrical entries
■
SPECIFICATIONS
MODEL
SV110 SV120 SV130 SV140 SV150
Fluid Air or Inert Gases
Pressure range (kgf/cm2)
0.15~0.7 (1.5~7.1)
0.1~0.7 (1.0~7.1) 0.2~0.7 (2.0~7.1)
Effective area (mm2(Cv)) 9.5 (0.53) 8.5 (0.49)
Ambient and media temp. Max. 50°C
Response time (5kgf/cm2)20 ms or less 35 ms or less
Max. Cycles/Second 10 C/S 3 C/S
Lubrication Not required
Manual override operation Non-locking push type
Shock/Vibration resistance 30G / 5G (8.3~2,000 Hz)
Protective structure Dust-proof
Coil rated voltage AC 50 / 60 Hz 110V, 220V DC 12V, 24V
Allowable voltage tolerance -15%~+10% of rated voltage
Coil insulation Class B or equivalent (130°C)
Apparent
power AC
Starting 4.5 VA (50 Hz), 4.2 VA (60 Hz)
Holding 3.0 VA (50 Hz), 2.6 VA (60 Hz)
Power
consumption DC 1.7W
Weight (kg) 0.1 0.15 0.16 0.16 0.16
Surge suppressor AC: Varistor, DC: Diode
Indicator lamp LED
■
HOW TO ORDER
Body Ported
20 L
-
SV 1 1
B
A
R1 R2P
AB
R1 P R2
R2PR1
B
A
R1 P R2
AB
R2
B
PR1
A
● COIL RATED VOLTAGE
●
CONFIGURATION
1
AC 110V
2
AC 220V
3
DC 12V
4
DC 24V
1
Single solenoid
2
Double solenoid
3
Closed center
4
Exhaust center
5
Pressure center
16

A B
R1 P R2 P.E.
A B
R1 P R2 P.E.
A B
R1 P R2 P.E.P.E.
P.E.
5 7 1 4 3 2 6
8
1 4 3 2 6
8
1 4 3 2 6
8
No. Description Material No. Description Material
BODY ADC-12 END COVER PLASTIC
PISTON PLATE POLYACETAL O-RING NBR
PISTON POLYACETAL SPRING SUS
SPOOL Al·NBR COIL ASS'Y
■
CONSTRUCTION /PARTS SV100 series
2-position Single Solenoid
2-position Double Solenoid
3-position Double Solenoid
17

65 87.5
3
13
17
35
2-Ø3.4
21
25
28
35 2-Ø3.4
27 95
27.2
5-PT 1/8
1.6
61
18
M5X0.8
103 300
29
34
101.5 MAX.10
48
55.5
PG.7
(Lead wire)
Manual
(Push type)
(Port P.E.)
300
(Lead wire)
~
=
~
=
AB
R1 R2
P
P.E
■
DIMENSIONS /2-POSITION SINGLE
SV110
- L
Lead Wire (L)
SV100 series
SV110
- PL/PS
Plug Connector (PL, PS)
SV110
- D/DL/DS
DIN Terminal (D, DL, DS)
18

1.6
76
120
17
35
2-Ø3.4
35
136
25
21
67 M5X0.8
27.2
5-PT 1/8
152 300
28
34
149
MAX.10 PG.7
48
55.5
(Lead wire)
Manual
(Push type)
(Port P.E.)
300
(Lead wire)
18
EP
~
=
~
=
R1 R2
P
AB
P.E
2-Ø3.4
■
DIMENSIONS /2-POSITION DOUBLE SV100 series
SV120
- L
Lead Wire (L)
SV120
- PL/PS
Plug Connector (PL, PS)
SV120
- D/DL/DS
DIN Terminal (D, DL, DS)
19

51 38
73 60
17
35
2-Ø3.4
35 2-Ø3.4
21
25
149
46.5 33.5
27.2
5-PT 1/8
1.6
M5X0.8
89 76 300
28
34
87.5 74.5
MAX.10
48
55.5
PG.7
(Lead wire)
Manual
(Push type)
(Port P.E.)
18
300
(Lead wire)
EP
~
=
~
=
AB
R1 R2
P
P.E
■
DIMENSIONS /3-POSITION CLOSED CENTER, EXHAUST CENTER, PRESSURE CENTER SV100 series
SV130/140/150
- L
Lead Wire (L)
SV130/140/150
- PL/PS
Plug Connector (PL, PS)
SV130/140/150
- D/DL/DS
DIN Terminal (D, DL, DS)
20
This manual suits for next models
12
Table of contents
Popular Control Unit manuals by other brands

oventrop
oventrop Multidis SFQ operating instructions

Frequency Central
Frequency Central MU Wave Runner LFO Build documentation

GEM
GEM 532 Installation, operating and maintenance instructions

Taoglas
Taoglas EDGE Locate quick start guide

DTI
DTI DCLDD1 0 Series manual

Jetter
Jetter JetWeb JX2-IA4 Operator's manual