Syncro View K67000M1 User manual

Product Manuals/Man-1092_Syncro_View_06 Page 2 of 12
Index Page
1. Introduction............................................................................................................3
2. Safety and mounting................................................................................................3
2.1 Safety.............................................................................................................................3
2.2 Mounting.........................................................................................................................4
3. Technical specification..............................................................................................5
4. Syncro View fascia...................................................................................................6
5. Connecting to the circuit board..................................................................................7
6. Power and data connections......................................................................................7
7. Addressing the units ................................................................................................7
8. Processor and watchdog reset switches.......................................................................8
9. Connecting to the Syncro panel .................................................................................9
10. Connections to Syncro View...................................................................................10
11. Adding a Syncro View to the Syncro panel...............................................................11
www.acornfiresecurity.com
www.acornfiresecurity.com

Product Manuals/Man-1092_Syncro_View_06 Page 3 of 12
1. Introduction
The Syncro View fire alarm annunciator is designed to provide indication and control of the
status of the Syncro analogue addressable fire control panel at a remote or multiple remote
locations or provide a more compact and pleasing user interface for the fire alarm system in
areas where a large control panel would be obtrusive.
The Syncro View provides the same indications and controls as the Syncro fire control panel to
which it is connected and can take full control of network systems if the control panel to which
it is connected is configured to do so.
The Syncro View repeater panel will be overridden and can not take control of the panel to
which it is connected if the main control panel is at access level 2.
For Syncro panels V5.90 and later or Syncro AS panels V5.22 and later, the Syncro View
buzzer will follow the buzzer operation of the host panel to which it is connected. Therefore
silencing the buzzer at the host panel will also silence the buzzer on the Syncro View
repeater(s) connected to that panel.
For all other panel firmware versions that support the View repeater, silencing the panel
buzzer at the host Syncro panel will not silence the View repeater buzzer. The View repeater
buzzer will need to be locally silenced.
2. Safety and mounting
2.1 Safety
Suppliers of articles for use at work are required under section 6 of the Health and Safety at
Work act 1974 to ensure as reasonably as is practical that the article will be safe and without
risk to health when properly used.
An article is not regarded as properly used if it is used ‘without regard to any relevant
information or advice’ relating to its use made available by the supplier.
This product should be installed, commissioned and maintained by trained service personnel in
accordance with the following:
(i) IEE regulations for electrical equipment in buildings
(ii) Codes of practice
(iii) Statutory requirements
(iv) Any instructions specifically advised by the manufacturer
According to the provisions of the Act you are therefore requested to take such steps as are
necessary to ensure that you make any appropriate information about this product available
to anyone concerned with its use.
Some models of this equipment are designed to be operated from 230V AC supplies therefore
all relevant safety precautions should be taken appropriate to equipment connected to mains
voltages.
Syncro VIEW fire alarm annunciators are environmental class A and are designed for indoor
use only at temperatures between -50C (+/- 3) and +400C (+/- 2) and with a maximum
relative humidity of 95%.
The IP rating for the enclosure is IP30.
Operation outside of these limits may render the equipment unsafe.
www.acornfiresecurity.com
www.acornfiresecurity.com

Product Manuals/Man-1092_Syncro_View_06 Page 4 of 12
2.2 Mounting
Surface mounting units should be mounted on a dry, flat surface, at eye height to the display
and in a level position such that the enclosure is not distorted.
Screws or bolts of a minimum of 4mm diameter must be used to mount the enclosure in all
three mounting positions.
Suitable fixings should be used at all fixing points such that the unit is securely mounted and
is not liable to move once fixed.
Units should not be mounted in another enclosure or near sources of excessive heat.
Cables should be connected using suitable cable glands. If additional cable entry points are
required, all swarf and debris caused by drilling of additional cable entries must be cleared
before power is applied.
Surface Mounting Flush Mounting
Fix to flat surface
using suitable wall
plugs.
www.acornfiresecurity.com
www.acornfiresecurity.com

Product Manuals/Man-1092_Syncro_View_06 Page 5 of 12
3. Technical specification
Table 1 - Electrical specifications
Construction 18SWG Mild steel - IP30 rated
Cable entry 20mm knockouts 5 in top, 5 in rear and 1 in the side
Finish BS 00-A-05 light grey, fine texture.
Weight 5Kg maximum
Mains supply (Mains powered
models only) 230V AC +10% - 15% (20 Watts maximum)
Mains supply fuse (Mains
powered models only) 2 Amp, 20mm, glass HRC
Power supply rating (Mains
powered models only) 0.75 Amps total including battery charge 28V +/- 2V
Maximum ripple current
(Mains powered models only) 200 millivolts
Battery type (Yuasa NP)
(Mains powered models only) Two 12 Volt 1.9Ah sealed lead acid in series
Battery charge voltage
(Mains powered models only) 27.6VDC nominal
Battery charge current (Mains
powered models only) 0.2A maximum
Battery fuse (Mains powered
models only) 200 milliamp, 20mm, glass
Maximum current draw from
batteries (Mains powered
models only)
0.095 Amps
24V supply (24V DC models
only) 21 to 30V DC
Quiescent current of panel in
mains fail 0.03A
Serial data connection 2 core RS485 (Up to 1200 metres total cable length)
Maximum terminal capacity 2.5mm²
Max number of units on each
Syncro panel serial bus 15
Maximum number of units to
be powered from Syncro Aux
24V output
4
www.acornfiresecurity.com
www.acornfiresecurity.com

Product Manuals/Man-1092_Syncro_View_06 Page 6 of 12
4. Syncro View fascia
K67001 and K67750 models with enable controls keyswitch
K67000 and K67751 models without enable controls keyswitch.
www.acornfiresecurity.com
www.acornfiresecurity.com

Product Manuals/Man-1092_Syncro_View_06 Page 7 of 12
5. Connecting to the circuit board
All connections for field wiring are to a single row of terminals along the bottom of the circuit
board.
Shielded fire alarm cable such as FP200 and metal cable glands must be used for all
connections to the unit. The resistance of any core of the data cable must not exceed 25
ohms. The shield of the cable must be bonded securely to the enclosure via the metal gland.
Wiring should enter the enclosure at the top or back of the unit using the knockouts provided
and be formed tidily to the appropriate terminals.
Terminals are capable of accepting wires of up to 2.5mm2.
Wiring must not go across the front of the circuit board. If cable entries need to be in positions
other than at the knockouts provided, wiring must be fed well away from the surface of the
circuit board.
6. Power and data connections
Each unit requires two cores for power and two cores for data transmission to and from the
control panel. A four core cable may be used for these connections. All of these connections
are polarity conscious and care should be taken to match the polarity with the corresponding
terminals at the control panel. Mains powered versions require only a two core cable to the
control panel and a local mains supply.
Data Termination
Up to 15 units can be connected to a Syncro control panel. In and out terminals for data and
24V DC are provided on each unit.
All units are supplied with a push on jumper fitted at position J3 on the left hand side of the
PCB. This jumper connects a terminating resistor which needs to be in place at the last unit on
the data line. If more than one unit is to be fitted, then the jumpers must be removed from
all units except the last one.
If there is only one unit fitted then the jumper should be left in place. The COMMS LED will
flash quickly while the unit is communicating correctly with the control panel and will be off if
the unit is disconnected or connected incorrectly.
7. Addressing the units
To enable the control panel to know whether any units that should be connected have been
disconnected and indicate a fault condition, each unit must be allocated an address. The
address switch should never be set with all switches off.
This is done by setting a binary number from 1 to 5 on the 4 way, DIL switch located at the
bottom of the PCB.
The order of the addresses is not important but each unit must be allocated a different
address.
The switch settings for each of the addresses are shown below.
www.acornfiresecurity.com
www.acornfiresecurity.com

Product Manuals/Man-1092_Syncro_View_06 Page 8 of 12
8. Processor and watchdog reset switches
The Syncro VIEW is controlled by a microprocessor, which will re-start itself and continue to
run if it stops for any reason due to severe electrical interference such as an electrical storm.
To ensure that the unit is not being subjected to continual, undue interference which may
effect its proper operation, a watchdog (W/DOG) LED indicator is latched on and a fault
condition signalled to the control panel.
If a processor re-start has occurred. this latched fault condition will need to de reset by
pressing the W//DOG RESET button on the bottom of the PCB.
A switch is also provided to manually re-start the processor PROC RESET. This switch can be
used while the units are connected to the system to ensure that the unit starts up and
establishes communication with the panel in a controlled and expected manner.
www.acornfiresecurity.com
www.acornfiresecurity.com

Product Manuals/Man-1092_Syncro_View_06 Page 9 of 12
9. Connecting to the Syncro panel
+
-
+
-
+
-
+
-
www.acornfiresecurity.com
www.acornfiresecurity.com

Product Manuals/Man-1092_Syncro_View_06 Page 10 of 12
10. Connections to Syncro View
S1
J3
J17
J4
OUT
CUT
OUT
CUT
OUT
CUT
OUT
CUT-OUT
RESETW/DOG
FIRE
FIRE
POWER
ALARM
PRE
FROUTE
TEST
BUZZER
SILENCE
DELAY
MEVENTS
DISABLE
+24V 0V
FAULT
FR
FAULT
SOUND
FAULT
S
FAULT
FAULT
P
G
ADJUST
CUT
RESET
FIT JUMPER
+
+-
-
ENABLE
COMM1COMM2
FOR END OF LINE
COMM1 COMM2 ADDRESS
-+-+
K6017ISS.03 COMMS
ACTIVE
SERIAL NUMBER
To next Syncro View repeater COMM1 + terminal
To next Syncro View repeater COMM1 - terminal
To next Syncro View repeater24V + terminal
To next Syncro View repeater 0V terminal
From Syncro panel COMMS+ terminal
From Syncro panel COMMS - terminal
From Syncro panel AUX24V + terminal
From Syncro panel AUX24V - terminal
NOTE
WIRING TO 24V+ AND 0V
TERMINALS NOT REQUIRED
ON MAINSPOWERED
VERSIONS
NOT USED
www.acornfiresecurity.com
www.acornfiresecurity.com

Product Manuals/Man-1092_Syncro_View_06 Page 11 of 12
11. Adding a Syncro View to the Syncro panel
The Syncro View repeater must be added to the system by configuring the Syncro panel using
the Loop Explorer configuration utility.
Click on the site name in the left hand window pane to show the option to add panels or
repeaters to the system.
If no panels are already added to the configuration then select the type of panel required.
To add a Syncro view repeater click on the View Repeater Icon.
To add a Syncro view repeater, double click on the View Repeater Icon.
Double click on the panel to which the View repeater is to be connected.
www.acornfiresecurity.com
www.acornfiresecurity.com

Product Manuals/Man-1092_Syncro_View_06 Page 12 of 12
The Syncro View repeater is now shown in the centre window pane.
Right click the Syncro View and select “edit settings” to give the Syncro View a panel name
(location) and an address on the serial bus. This address should be different for each Syncro
View added and different to any other I/O boards that may exist on the serial bus.
Once the configuration file has been loaded into the panel the panel will now expect to see a
Syncro View at the address allocated to it and will show a fault condition if the Syncro View is
not fitted or is removed.
www.acornfiresecurity.com
www.acornfiresecurity.com
This manual suits for next models
7
Table of contents
Popular Repeater manuals by other brands

Altronix
Altronix NetWayXT instruction manual

Multitone
Multitone EkoSecure ESREP Quick installation guide

Compaq
Compaq Netelligent 3512 user guide

Allied Telesis
Allied Telesis AT-MR420T installation guide

Tema Telecomunicazioni
Tema Telecomunicazioni SipComStage AD639SR product manual

Ritron
Ritron RLR-465NX quick start guide