9) Press TARE key
[ E n t r
Zero point is being set. When the scale is stable a weight value will flash. This is the weight you will need to
calibrate the scale.
3 0. 0 0
10) Add the correct weight to the platform and press the TARE key.
11) Wait until the scale is stable. You will hear 3 beeps. Full capacity weight value will flash in display window.
3 0. 0 0
12) Remove the weight from the platform and press any key.
C A L 0 1
13) Press UNITS key.
C A L 0 0
14) Press TARE key
0 2 C A L
15) Turn scale OFF
16) Re-adjust silver switch located on lower portion of the main board to the original position.
17) Turn the scale OFF and close it up.
9903II Calibration Instructions
Page2of2
A Division of T.E. Bouton Company, Inc.