10 Page
2. Direct-vent conversion kit: 9007667005
(TK-TV10)
This kit can be used to convert the water
heater from a single vent system to a direct-
vent (double vent) (or sealed combustion)
system with a 3 in. (76 mm) intake. Install
this conversion kit in accordance with the
installation instructions and any applicable
codes.
The pipe cover protects the
plumbing pipes to the water
heater from unexpected
adjustments. This pipe cover
is fixed to the bottom of the
water heater, which hides the
plumbing and improves the
visual aspects of the whole
installationforthewaterheater.
4. Recess box: 9007674005 (TK-RB02)
Therecessboxwillallowfor“clean”
installations. The water heater
fits inside the recess box, which
hidesandprotectsthewholewater
heater and plumbing. The recess
box will fit in-between most wall
studs.
1. 4” Backflow preventer and F-F adaptor:
9007996005
Therearetwofunctionsavailableforthisadaptor,
whichcanbeconnectedwiththewaterheaterand
NovaVent venting line and prevents the backflow
ofairthroughtheexhaustvent.Thishelpsprevent
harmfulexhaustgasesfromenteringthehome,as
wellashelpingtopreventtheunitfromfreezingin
areaswherecoldaircanbeblownordrawnintothe
exhaustsystem.Installthisadaptorinaccordance
withtheinstallationinstructionsthatarepackaged
withtheadaptorandanyapplicablecodes.
5. Sidewall vent terminator (Hood) and Wall thimble:
Used when terminating direct-vent (sealed combustion) systems,
with indoor models that require a 3 in. intake and a 4 in. exhaust.
This concentric termination provides the convenience of only having
tomakeone penetrationthroughasidewallinsteadoftwoseparate
penetrations for the intake and exhaust piping. The termination
includes a bird screen, restricting small animals, pests, and foreign
objectsfromenteringintotheventsystem.Thissidewalltermination
isavailableintwodifferentsizes,tocoverawiderangeof
wallthicknesses.Fordifferentwallthicknesses,
therearetworangesoflengthsavailable.(Refer
totheNovaVentbrochurefordetails.)
Installaon
Installaon Manual
Covering wall thicknesses Part#
TerminatorHood 9007999005
WallThimble4-7in. 9008345005
WallThimble5-10in. 9008346005
Termination+Thimble4-7in. 9008004005
Termination+Thimble5-10in. 9008005005
3. Pipe cover: 9007670005 (TK-PC01)
Covering wall thicknesses Part#
5.0–10.0in. 9008147005
12.0–18.0in. 9008148005
6. Direct-vent concentric termination:
They are used when venting out through the wall. These terminations are special stainless steel
ventsforgasappliancesandareULlistedasCategoryII,IIIandIV.Fordifferentwallthicknesses,
therearetworangesoflengthsavailable.(RefertotheNovaVentbrochurefordetails.)Installthese
ventterminationsinaccordancewiththeirinstallationinstructionsandanyapplicablelocalcodes.
Wall Thimble
Terminator Hood