1. Overview
The CSB.01 Wireless Network Range Extender is a high performance,
microprocessor controlled, bidirectional RF amplifier for the entire North
American 850 MHz cellular and 1900 MHz PCS frequency bands. The amplifier
has an automatic gain and oscillation control system that will automatically
adjust the gain and the output power if a signal anomaly occurs. This amplifier
is designed to operate as a direct connect unit within a cellular system, for
maximum performance in weak signal coverage areas. The input power
requirements for the amplifier are positive 8.0 to 32.0 volts DC (negative
ground).
2. Parts List
Depending upon the connector type of the cellular device, Taoglas can
customize the M2M kit to include the appropriate adapters to ensure a
seamless and quick installation. Adapter types include, but are not limited to
SMA, RP-SMA, MMCX, MCX, FME, and TNC.
1: CSB.01 Amplifier Unit
6. Optional –SMA-to-MMCX
Device Cable – If connecting
to an MMCX device.
3: Hardwire DC
Power Cable
2: AC/DC Power Adapter
5: SMA-to-SMA Device
Cable – If connecting to an
SMA device
4: Magnetic-Mount
Outdoor Signal Antenna
MB.TG30.A.305111

3. Installation Guide
Disclaimer: Installation of this device requires knowledge of basic electrical
and experience with installing electronic devices. We recommend seeking
a professional installer if you are not accustomed to installing electronics
or high tech devices. Installation of this device is at your own risk. Taoglas
assumes no responsibility for the installation or improper operation of this
device. Contact your dealer or [email protected]om with “Installation Help” in
the subject line for assistance.
4. Installation with an SMA
Device - Fixed Location
1. If connecting to a Cellular Modem (e.g.
Raven X, CradlePoint), connect the
SMA to SMA device cable (#5 on Parts
List) to the Taoglas Amplifier
connector marked “Device”.

2. Connect the SMA end of the SMA to
SMA device cable to the Cellular
Modem antenna connection.
3. Mount the Outdoor Signal Antenna
(#4 on Parts List) vertically on any
metal surface.
a. Connect the Outdoor Signal Antenna
connector to the Taoglas amplifier
SMA connector marked “Antenna”.
4. Plug the AC Adapter (#2 on Parts List)
into a nearby wall outlet.
5. Insert the AC Adapter connector plug
into the amplifier and watch the LED
indicators.

5. Installation with an
SMA Device - Mobile Location
1. If connecting to a Cellular Modem or
Mobile Data Terminal (e.g. Raven X,
etc) in a vehicle or mobile application,
connect the SMA to SMA device cable
(#5 on Parts List) to the Taoglas
Amplifier connector marked “Device”.
2. Connect the SMA end of the SMA-to-
SMA device cable to the Cellular
Modem or MDT antenna connection.
3. Mount the Outdoor Signal Antenna
(#4 on Parts List) vertically on any
metal surface on the roof, hood or
trunk of the vehicle.
4. Connect the Outdoor Signal Antenna
connector to the Taoglas amplifier
SMA connector marked “Antenna”.
5. Plug the 12V Hardwire DC Cable
(#3 on Parts List) into the vehicle fuse
block. You must connect the red wire
to a positive terminal from the fuse
panel with a 3 ampere fuse rating.
The black wire should be attached to
a ground of the vehicle. Power may
also be provided to the amplifier using
a 12V cigarette lighter adaptor.
(Not included)
6. Insert the Hard Wire DC Cable
connector plug into the amplifier and
watch the LED indicators.

6. LED Diagnostics
Once the amplifier is installed properly and power is applied, the LEDs will
both turn on followed by the green LED flashing. The green LED will flash
while the amplifier increases its gain to the optimum level. The red LED
may also flash during this stage while the gain (power) is properly set on
the amplifier. When power control is established, the green LED will remain
constantly on. You may see the green and red LEDs flash back and forth, THIS
IS NORMAL. In areas where the cellular network is adequate, the amplifier
will maintain a maximum power level acceptable for normal operation and
prevent overloading the wireless phone, as well as keeping RF signal levels at
a minimum for a healthy environment. If the red LED is constantly on and the
green LED is off, the amplifier has detected a fault. The amplifier will shut
down automatically and restart. If the fault persists, reposition the antenna
until normal operation is achieved. - Once normal operation is established,
you may permanently mount the antennas in the locations you chose in the
prior steps.
7. Diagnostic LED Definitions
1. Solid Green and Red – LED test, the unit is initializing
2. Solid Green – Normal operation
3. Flashing Green – Normal operation, increasing gain setting
4. Solid Green and Flashing Red
– Normal operation, decreasing gain setting
5. Solid Red and No Green
– Fault detected (Unit will shut down until power is cycled.)

8. Passive Bypass Technology
– Patent Pending
The CSB.01 amplifier is equipped with Passive Bypass technology. This feature
allows the amplifier to passively bypass itself and become merely a pass
through cable when amplification is not necessary, during loss of power or
when a fault is detected.
Passive Bypass technology is useful in applications where the amplifier is
mobile, moving in and out of poor signal areas. The amplifier will bypass
itself when close to cell towers, completely eliminating any potential for
network disrupting noise power caused by too much amplification near a cell
tower. The technology is also extremely useful in fire and security system
installations where a connection with the antenna must always be maintained,
even with loss of power.
Taoglas CSB.01
Competitor

9. CSB.01 Specifications
• Frequency Range: Cellular 850 (824MHz – 894MHz), PCS 1900 (1850MHz – 1990MHz)
• 20dB BW: 850 UL: 39MHz, 1900 UL: 115MHz
• Rated Uplink Maximum Output Power: Cellular 850; 27dBm, PCS 1900; 27dBm
• Rated Downlink Maximum Output Power: Cellular 850; -20dBm, PCS 1900; -20dBm
• Current Draw @ 12VDC: Idle: 250 milliamperes; Max: 1 amperes
• Power Requirement: 8.0 to 36.0 volts DC (negative ground), Connector is center positive
• Nominal Gain: Cellular 850: 15dB, PCS 1900: 15dB
• Input/output Impedance: 50 Ohms
• Rated Mean Output Power: 27dBm
FCC ID: XS7-WRE2710
IC ID: 8918A-WRE2710
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference,
and (2) this device must accept any interference received, including
interference that may cause undesired operation.
This is a CONSUMER device.
BEFORE USE, you MUST REGISTER THIS DEVICE with your wireless provider
and have your provider’s consent. Most wireless providers consent to the use
of signal boosters. Some providers may not consent to the use of this device
on their network. If you are unsure, contact your provider.
You MUST operate this device with approved antennas and cables as specified
from the manufacturer. Antennas MUST be installed at lease 20cm / 8 inches
from any person.
You MUST cease operating this device immediately if requested by the FCC or
a licenced wireless service provider.
WARNING - E911 location information may not be provided or may be
inaccurate for calls used by this service.

The term “IC:” before the radio certification number only signifies that Industry
of Canada technical specifications were met. The Manufacturer’s rated output
power of this equipment is for single carrier operation. For situations when
multiple carrier signals are present, the rating would have to be reduced
by 3.5 dB, especially where the output signal is re-radiated and can cause
interference to adjacent band users. This power reduction is to be by means
of input power or gain reduction and not by an attenuator at the output of the
device.
La puissance de sortie nominale indiquée par le fabricant pour cet appareil
concerne son fonctionnement avec porteuse unique. Pour des appareils avec
porteuses multiples, on doit réduire la valeur nominale de 3,5 dB, surtout
si le signal de sortie est retransmis et qu’il peut causer du brouillage aux
utilisateurs de bandes adjacentes. Une telle réduction doit porter sur la
puissance d’entrée ou sur le gain, et ne doit pas se faire au moyen d’un
atténuateur raccordé à la sortie du dispositif.
FCC Regulatory Guidance: Taoglas’s CSB.01 operates under the rules and
regulations as provided by the Federal Communications Commission (FCC).
For more information on these rules and regulations, please contact the FCC
directly at (888)-225-5322.
10. Safeguard Features
The amplifier has an automatic gain and oscillation control system that will
automatically adjust the gain and the output power if a signal anomaly occurs.
This amplifier is designed to operate as a tethered (direct connect) unit within
a cellular system, for maximum performance in weak signal coverage areas.
11. Antennas
You MUST operate this device with approved antennas and cables as specified
by the manufacturer. Antennas MUST be installed as least 20 cm (8 inches)
from any person.
Included antenna, base & cable:
MB.TG30.A.305111 - Apex Magforce TG.30.8111 2G/3G/4G Terminal Antenna
on Magnetic Base 3M CFD-200 SMA(M)

12. Warranty Information
Limited Warranty
Taoglas Ltd. warrants that this product is free from defects in materials or
workmanship for one year from the date of purchase. Within this period,
Taoglas Ltd., will, at its sole option, repair or replace any components which
fail in normal use. Such repairs or replacement will be made at no charge
to the customer for parts or labour, provided that the customer shall be
responsible for any transportation cost. This warranty does not cover failures
due to abuse, misuse, accident or unauthorized alterations or repairs.
Repairs have a 90 day warranty. If the unit sent in is still under its original
warranty, then the new warranty is 90 days or to the end of the original one
year warranty, depending upon which is longer.
Taoglas Ltd. retains the exclusive right to repair or replace the product or offer
a full refund of the purchase price at its sole discretion. Such remedy shall be
your sole and exclusive remedy for any breach of warranty. Taoglas Ltd. shall
not be liable for any incidental or consequential damages for breach.
Procedure for Claims under Limited Warranties
To obtain warranty service, an original or copy of the sales receipt from the
original retailer is required.
To obtain warranty service, follow these two steps:
1. Contact Taoglas Ltd. via email to receive authorization (RMA) number at
nasal[email protected].
2. Once you have obtained an RMA #, ship the unit, copy of the sales receipt,
along with the RMA number to:
Taoglas
RMA #: {insert RMA number}
8375 Camino Santa Fe, Suite A
San Diego, CA 92121, USA

Taoglas, 8375 Camino Santa Fe, Suite A, San Diego, CA 92121, USA