manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Tech Novitas
  6. •
  7. Controllers
  8. •
  9. Tech Novitas Olbers-10KVA User manual

Tech Novitas Olbers-10KVA User manual

MODEL: Olbers-10K/ 15K/ 20K/ 30KVA
Olbers
10Kva Olbers
15Kva Olbers
20Kva Olbers
30Kva
Designed by Tech Novitas Corp. LLC ,Wyoming, U.S.A, www. technovitas.com Email us at: [email protected]
Tech Novitas FZC: P. O. BOX No.: 8073, SAIF Zone, U.A.E. Phone: + 971 6 5529892 Fax:. + 971 6 5529897 Designed by Tech Novitas Corp. LLC ,Wyoming, U.S.A, www. technovitas.com Email us at: [email protected]
Tech Novitas FZC: P. O. BOX No.: 8073, SAIF Zone, U.A.E. Phone: + 971 6 5529892 Fax:. + 971 6 5529897
Automatic Voltage Regulator
USER MANUAL
Designed by Tech Novitas Corp. LLC ,Wyoming, U.S.A, www. technovitas.com Email us at: [email protected]
Tech Novitas FZC: P. O. BOX No.: 8073, SAIF Zone, U.A.E. Phone: + 971 6 5529892 Fax:. + 971 6 5529897 Designed by Tech Novitas Corp. LLC ,Wyoming, U.S.A, www. technovitas.com Email us at: [email protected]
Tech Novitas FZC: P. O. BOX No.: 8073, SAIF Zone, U.A.E. Phone: + 971 6 5529892 Fax:. + 971 6 5529897
Three Phase Automatic
Compensation Voltage Stabilizer
MODEL:
Olbers-40K/50K/60K/80K/100K/150K/200KVA
REAL TIME STATUS
MONITORING
DISPLAY
TO SWITCH BETWEEN THE FOLLOWING DISPLAY WINDOWS
TO MONITOR THE REAL TIME STATUS OF THE PCB, THE
TRANSFORMER,THE AVR FUNCTION AND THE TEMPERATURE, ETC.
INPUT VOLTAGE
OUTPUT VOLTAGE
V Line V Phase
V Phase
V Line
INPUT VOLTAGE
OUTPUT VOLTAGE
VAB VBC VAC
VAB VBC VAC
OUTPUT CURRENT
FREQUENCY
A A A B A C
F A F B F C
THREE PHASE VOLTAGE REGULATOR
375 386 381
380 380 380
INP UT
OUT PU T
AB BC AC
AB BC AC
Please read this manual carefully before
operating this stabilizer.
Easy-Checking
1. When input voltage of any phase less than 100Vac output will
be cut off. The LCD screen will display “INPUT is lack of PHASE X!” or
“PHASE X communication error!” X means the lacked phase, A/B/C
±5Vac,
2. When output voltage of any phase less than 180Vac th
will switch to delay status, delaying 3 seconds, then switch into Low
Voltage Protection. The LCD screen will show “TOO LOW INPUT
VOLTAGE! OUTPUT CUT OFF AUTOMATICALLY!” When the output
voltage of each phase drops to 195Vac output will recover.
±3Vac,
±3Vac,
3. When output voltage of any phase higher than 250Vac t
will switch to delay status, delaying 3 seconds, then switch into High
Voltage Protection. The LCD screen will show “TOO HIGH INPUT
VOLTAGE! OUTPUT CUT OFF AUTOMATICALLY!” When the output
voltage of each phase drops to than 240Vac output will recover.
±3Vac,
±3Vac,
4. When temperature of any transformer goes up to 120 10 C, output
will be cut off. The LCD screen will show “TOO HIGH TEMPERATURE!
OUTPUT CUT OFF AUTO!” When the temperature drops down to 70
10 C, output will recover.
±
±
5. When the LCD screen shows “OVERLOAD!”, th s under
overload status, output will be cut off automatically.
* If more questions, pls. contact the after-sales office for answers.
PHAS E A REGUL ATING T RA NS FORMER
PHAS E B RE GU LATIN G TRANSFO RM ER
PHAS E C RE GU LATIN G TRANSFO RM ER
Olbers 40-200K AVR M annual
he model
e Olbers
e model i
Designed by Tech Novitas Corp. LLC ,Wyoming, U.S.A, www. technovitas.com Email us at: [email protected]
Tech Novitas FZC: P. O. BOX No.: 8073, SAIF Zone, U.A.E. Phone: + 971 6 5529892 Fax:. + 971 6 5529897
REAL TIME STATUS
MONITORING
DISPLAY
TO SWITCH BETWEEN THE FOLLOWING DISPLAY WINDOWS
TO MONITOR THE REAL TIME STATUS OF THE PCB, THE
TRANSFORMER,THE AVR FUNCTION AND THE TEMPERATURE, ETC.
INPUT VOLTAGE
OUTPUT VOLTAGE
V Line V Phase
V Phase
V Line
INPUT VOLTAGE
OUTPUT VOLTAGE
VAB VBC VAC
VAB VBC VAC
OUTPUT CURRENT
FREQUENCY
A A A B A C
F A F B F C
THREE PHASE VOLTAGE REGULATOR
375 386 38 1
380 380 380
INP UT
OUT PUT
AB BC AC
AB BC AC
LCD DISPLAY FOR INPUT /
OUTPUT VOLTAGE
AND CURRENT,FREQUENCY
PRESS THIS BUTTEN TO UNFOLD
THE DOOR HANDLE
STANDING FEET : SCREW THE SCREW CAP
BY COUNTERCLOCKWISE TO DROP DOWN
THE FEET,BY ANTICLOCKWISE TO LIFT UP
THE FEET.
The input plug and out socket are different according
to different country and refer to the product for
reference.
Voltage and frequency as the appliance’s it connected.
within the listed range of the input voltage of the regulator.
compressor, the starting power is generally several time of
the appliance’s listed power rating. Make sure that the total
starting power capacity of all connected appliance does not
exceed the listed maximum output power of the regulator.
For color TV, calculate it twice as its listed capacity.
BYPASS SWITCH
POWER ON STABILIZER FUNCTION
POWER OFF BYPASS SWTICH
POWER ON BYPASS FUNCTION
POWER OFF STABILIZER FUNCTION
UP
DOWN
DO NOT TOUCH THE BYPASS SWITCH
BEFORE YOU POWER OFF THIS
STABILIZER
ONLY QUALIFIED PERSONNEL CAN
OPERATE THIS STABILIZER
RISK OF HIGH VOLTAGE ELECTRIC SHOCK
DANGER
Tools:Wrench
GENERAL POWER SWITCH. IF OVERLOAD,
THIS GENERAL POWER SWITCH WILL
JUMP OFF. RESTARTED BY HAND ONLY.
Designed by Tech Novitas Corp. LLC ,Wyoming, U.S.A, www. technovitas.com Email us at: [email protected]
Tech Novitas FZC: P. O. BOX No.: 8073, SAIF Zone, U.A.E. Phone: + 971 6 5529892 Fax:. + 971 6 5529897 Designed by Tech Novitas Corp. LLC ,Wyoming, U.S.A, www. technovitas.com Email us at: [email protected]
Tech Novitas FZC: P. O. BOX No.: 8073, SAIF Zone, U.A.E. Phone: + 971 6 5529892 Fax:. + 971 6 5529897
Back View
Terminal Connection Cover
INP UT OU TP UT
G N A B CA B C N G
FAN:120X120MM, 220VAC, START
TO WORK AUTOMATICALLY WHEN
START THE STABILIZER.
SAFE DISTANCE FOR RADIATING
NOT LESS THAN 50CM
Output Connection
Input Connection
MAKE SURE THAT YOU HAVE
CONNECTED THE GROUNDING
WELL, OTHERWISE YOU WILLNOT
HAVE PROPER OUTPUT.
INSIDE COOLING FAN, 12VDC,
80X80MM
Loading Capability Diagram
Model: Olbers 40Kva Model: Olbers 50K/60K/80Kva
Model: Olbers 100Kva Model: Olbers 150Kva
Model: Olbers 200Kva
Designed by Tech Novitas Corp. LLC ,Wyoming, U.S.A, www. technovitas.com Email us at: [email protected]
Tech Novitas FZC: P. O. BOX No.: 8073, SAIF Zone, U.A.E. Phone: + 971 6 5529892 Fax:. + 971 6 5529897 Designed by Tech Novitas Corp. LLC ,Wyoming, U.S.A, www. technovitas.com Email us at: [email protected]
Tech Novitas FZC: P. O. BOX No.: 8073, SAIF Zone, U.A.E. Phone: + 971 6 5529892 Fax:. + 971 6 5529897
REAL TIME STATUS
MONITORING
DISPLAY
TO SWITCH BETWEEN THE FOLLOWING DISPLAY WINDOWS
TO MONITOR THE REAL TIME STATUS OF THE PCB, THE
TRANSFORMER,THE AVR FUNCTION AND THE TEMPERATURE, ETC.
INPUT VOLTAGE
OUTPUT VOLTAGE
V Line V Phase
V Phase
V Line
INPUT VOLTAGE
OUTPUT VOLTAGE
VAB VBC VAC
VAB VBC VAC
OUTPUT CURRENT
FREQUENCY
A A A B A C
F A F B F C
THREE PHASE VOLTAGE REGULATOR
375 386 381
380 380 380
INPUT
OUTPUT
AB BC AC
AB BC AC
PRESS THIS BUTTON FOR 2 SECONDS,TO MONITOR THE REAL TIME
STATUS OF THE PCB, THE TRANSFORMER,THE AVR FUNCTION AND
THE TEMPERATURE, ETC.
DISPLAY BUTTON:
PRESS THIS BUTTON FOR 2
SECONDS, THE SCREEN
WILL DISPLAY THE OUTPUT
CURRENT AND FREQUENCY.
PRESS THIS BUTTON AGAIN,
THE LCD SCREEEN WILL
DISPLAY THE INPUT AND
OUTPUT LINEVOLTAGE AND
PHASE VOLTAGE AND OUTPUT
CURRENT
WHEN SWITCH ON THIS STABILIZER, THIS LCD
SCREEN WILL SHOW THE INPUT LINE VOLTAGE
AND OUTPUT LINE VOLTAGE
FUSE
Delay time
Frequency
High protect
output voltage
Low protect
output voltage
High protect
temperature
Rating
6S
120 C
Specification are subjected to change without prior notice.
---- ---- ---- ----
Technology Parameter
MODEL
INPUT
OUTPUT
Phase Voltage
Precision
Power
±3%
-40KVA
40KVA 100KVA 150KVA
---- ---- ----
-100KVA
-150KVA
180V
150-250V~
380V~
220V~
260-430V~ 3/N~
250V
Phase Voltage
Phase
Voltage
Phase
Voltage
Linear Voltage
Linear Voltage
-50KVA
-60KVA
-80KVA -200KVA
300-460V~ 3/N~
50KVA 60KVA 80KVA 200KVA
50/60Hz
170-270V~
220V~
380V~ 3/N~
Olbers Olbers Olbers Olbers Olbers Olbers Olbers
Designed by Tech Novitas Corp. LLC ,Wyoming, U.S.A, www. technovitas.com Email us at: [email protected]
Tech Novitas FZC: P. O. BOX No.: 8073, SAIF Zone, U.A.E. Phone: + 971 6 5529892 Fax:. + 971 6 5529897 Designed by Tech Novitas Corp. LLC ,Wyoming, U.S.A, www. technovitas.com Email us at: [email protected]
Tech Novitas FZC: P. O. BOX No.: 8073, SAIF Zone, U.A.E. Phone: + 971 6 5529892 Fax:. + 971 6 5529897

This manual suits for next models

3

Popular Controllers manuals by other brands

Basler VR63-4A/UL instruction manual

Basler

Basler VR63-4A/UL instruction manual

Schaudt LRM 1218 operating instructions

Schaudt

Schaudt LRM 1218 operating instructions

TAC Vista TAC Xenta OP manual

TAC Vista

TAC Vista TAC Xenta OP manual

Epson S1D13706 Technical manual

Epson

Epson S1D13706 Technical manual

Rockwell Automation MagneMotion 700-0871-00 user manual

Rockwell Automation

Rockwell Automation MagneMotion 700-0871-00 user manual

Mitsubishi Electric MELSERVO MR-J4-B-LL Series instruction manual

Mitsubishi Electric

Mitsubishi Electric MELSERVO MR-J4-B-LL Series instruction manual

Lombardini 15 LD 225 Use maintenance and consumer information

Lombardini

Lombardini 15 LD 225 Use maintenance and consumer information

Rockwell Automation Allen-Bradley Guardmaster 440G-MZ Original instructions

Rockwell Automation

Rockwell Automation Allen-Bradley Guardmaster 440G-MZ Original instructions

PXM PX340+ user manual

PXM

PXM PX340+ user manual

URC MX-490 owner's manual

URC

URC MX-490 owner's manual

Kitz F Series Operation manual

Kitz

Kitz F Series Operation manual

Linear Technology LTM4650EY-1 Demo Manual

Linear Technology

Linear Technology LTM4650EY-1 Demo Manual

IBC V-10 manual

IBC

IBC V-10 manual

Emerson PeC C100 Hardware Implementation Guidelines

Emerson

Emerson PeC C100 Hardware Implementation Guidelines

Omron Trajexia TJ1-DRT Hardware reference manual

Omron

Omron Trajexia TJ1-DRT Hardware reference manual

ACME DMX Master I user guide

ACME

ACME DMX Master I user guide

Ruida Technology BWK301R operating instructions

Ruida Technology

Ruida Technology BWK301R operating instructions

Siemens Synco 200 Basic documentation

Siemens

Siemens Synco 200 Basic documentation

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.