TECNARE ARRAY Series User manual

Keep these important operatin instructions.
Check www.tecnare.com for updates
DMA 8X8
DSP MATRIX
Operation Manual
Commercial Series


General Information
DMA 8x8 Operation Manual
Ver.: 1.0_UK 05/2022
©EXEL ACOUSTICS SL; all right reserved
The information contained in this manual has been carefully
checked for accuracy, at the time of going to press, however
no guarantee is given with respect to the correctness.
Exel Acoustics SL accepts no responsibility for any errors or
inaccuracies that may appear in this manual or the products
and software described in it. Technical specications, dimen-
sions, weights and properties do not represent guaranteed
qualities. As manufacturers we reserve the right to make
alterations and modications within the framework of legal
provisions, as well as changes aimed at improving quality.
EXEL ACOUSTICS SL
CL Encinar, 282 – Pol. Ind. Monte Boyal
45950 Casarrubios del Monte (Toledo) Spain
Phone: (+34) 918 170 110 Fax:

4
Operation Manual
www.tecnare.com
IMPORTANT SAFE INSTRUCTIONS
Before using our product, be sure to carefully read the manual and safe Instructions. Keep this document with the device
all time.
1. Read these instructions
2. Keep these instructions.
3. Heed all warnings.
4. Follow all SAFETY INSTRUCTIONS as well DAN-
GER and OBLIGATION warnings.
5. Only use attachments / accessories specied by Exel
Acoustics SL.
6. Do not use this apparatus near water.
7. Clean only with dry cloth.
8. Do not block any ventilation openings. Install in ac-
cordance with Exel Acoustics’ instructions.
9. Do not install near any heat sources such as radi-
ators, heat registers, stoves or other apparatus (in-
cluding ampliers) that produce heat.
10. Do not defeat the safety purpose of the polarized or
grounding type plug. A polarized plug has two blades
with one more wide than the other. A grounding type
plug has two blades and a third pin are provided for
your safety. If the provided plug does not t into your
outlet, consult an electrician for replacement of the
obsolete outlet.
11. Protect the power cord from being walked on or
pinched particularly at plugs, convenience recepta-
cles and the point where they exit from the appara-
tus.
12. Unplug this apparatus during lightning storms or
when unused for long periods of time.
13. Refer all servicing to qualied service personnel. Ser-
vice is required when the apparatus has been dam-
aged in any way, such as power-supply cord or plug
damaged, liquid has been spilled or objects have
fallen into the apparatus, this apparatus has been ex-
posed to rain or moisture, does not operate normally,
or has been dropped.
14. Use the mains plug to disconnect the device from
mains.
15. Do not expose this equipment to dripping or splash-
ing and ensure that no objects lled with liquids, such
as vases, are placed on the equipment.
16. The mains plug of the power supply cord shall remain
readily operable.
17. Do not connect the unit’s output to any other volt-
age source, such as battery, mains source, or power
supply, regardless of whether the unit is turned on
or o.
18. Do not remove the top (or bottom) cover. Removal of
the cover will expose hazardous voltages. There are
no user serviceable parts inside and removal may
void warranty.
19. If the equipment is used in a manner not specied by
the Exel Acoustics, the protection by the equipment
may be impaired.
CAUTION: To reduce the risk of re of electric
shock, do not expose this device to rain or mois-
ture.
CAUTION: Do not remove any covers, loosen any
xings or allow items to enter any aperture
CAUTION: The rear of the product may get hot.
Avoid direct skin contact during operation and for
at least 5 minutes after power has been isolated.
CAUTION: The product must only be positioned at
oor level when operated in a horizontal position.

5
Operation Manual
www.tecnare.com
PRECAUCIÓN:Para reducir el riesgo de incendio
por desgarga eléctrica, no exponga este aparato a
la lluvia o a la humedad.
PRECAUCIÓN: No retire la cubiert, aoje tornillos o
permita la entrada de elementos por ninguna aber-
tura
PRECAUCIÓN: La parte trasera del equipo puede
calentarse. Evite el contacto directo con la piel du-
rante su funcionamiento y durante, al menos, 5 mi-
nutos después de que se haya apagado
PRECAUCIÓN: El equipo solo debe colocarse en el
suelo cuando se opera en posición horizontal.
Antes de usar este producto, asegúrese de leer cuidadosamente el manual y las instrucciones de seguridad.
1. Lea estas instrucciones.
2. Conserve estas instrucciones.
3. Respete y siga todas las advertencias.
4. Siga todas las INSTRUCCIONES DE SEGURIDAD,
así como las advertencias de PELIGRO y OBLIGA-
CIÓN.
5. Utilice solo accesorios autorizados por Exel Acous-
tics SL.
6. No use este aparato cerca del agua.
7. Limpiar solo con un paño seco.
8. No bloquee las aberturas de ventilación e intalar de
acuerdo con las instrucciones de Exel Acoustics.
9. No instale el aparato cerca de fuentes de calor tales
como radiadores, calefactores estufas u otros apara-
tos que produzcan calor.
10. Esta unidad debe ser conectada mediante un cable
de alimentación de 3 hilos. Por razones de seguri-
dad, LA CONEXIÓN A TIERRA NO DEBE DESCO-
NECTARSE EN NINGUNA CIRCUNSTANCIA.
11. Proteja el cable de alimentación de ser pisado o
aplastado, especialmente los enchufes, receptáculos
y en el punto en el que salen del aparato.
12. Desconecte este aparato durante tormentas eléctri-
cas, terremotos o cuando no vaya a emplearse du-
rante largos periodos.
13. Confíe las reparaciones a personal cualicado. Se
requiere servicio cuando el aparato ha sido dañado
de alguna manera como por ejemplo si el cable de
alimentación o el enchufe está dañado, se ha derra-
mado líquido o han caido objetos dentro del aparato,
el aparato ha sido expuesto a lluvia o a la humedad,
no funciona con normalidad o se ha caído.
14. Desconecte completamente este aparato de la red
eléctrica desconectando el cable de alimentación.
15. No exponga este equipo a salpicaduras ni coloque
sobre él objetos que contengan líquidos, tales como
vasos o botellas. Equipo IP20.
16. El enchufe o la conexión a red debe ser facilmente
accesible.
17. No conecte la salida de la unidad a ninguna otra
fuente de voltaje, como batería o fuente de alimen-
tación independientemente de si la unidad está en-
cendida o apagada.
18. No retire la cubierta superior (o inferior). La retirada
de la cubierta lo expondrá a voltajes peligroso. No
hay piezas reparables por el usuario en el interior y
su extracción podría anular la garantía.
19. Si el equipo se utiliza de la forma no especicada por
Exel Acoustics, la protección del equipo puede verse
afectada.
IMPORTANTES INSTRUCCIONES DE SEGURIDAD

6
Operation Manual
www.tecnare.com
SYMBOL USED
AVERTISSEMENT DE SECURITE
Pour déconnecter l’appareil de l’alimentation principale de façon permanente, débranchez le connecteur du câble fourni à l’arrière
de l’appareil.
Ne retirez pas les couvercles, ne desserrez pas les xations et ne laissez aucune pièce s’introduire dans les ouvertures.
Ne placez pas d’objets contenant du liquide à proximité de l’appareil.
Ne remplacez le fusible de réseau principal que par un fusible du même type.
Le radiateur arrière de cet appareil devient chaud. Evitez tout contact direct avec la peau pendant le fonctionnement et au moins
5 minutes après la mise hors tension de l’appareil
Warning
Caution
Notice
tip or pointer
This simbol indicate Risk of injury. It is essential to observe this warning. Non-compliance can lead to serious
injury or death.
Este símbolo indica Riesgo de lesiones. Es fundamental observar esta advertencia. Su incumplimiento puede
provocar lesiones graves o la muerte.
This simbol indicate Personal injuries. It is essential to observe this warning. Non-compliance can lead to minor
or slight injury.
Este símbolo indica Lesiones personales.Es fundamental observar esta advertencia. Su incumplimiento puede
provocar lesiones leves.
This simbol indicate Damage to the devices or environment. It is essential to observe this warning. Non-compli-
ance can lead to damage to property or equipment or environmental damage.
Este símbolo indica Daños a los dispositivos o al medio ambiente. Es fundamental observar esta advertencia.
Su incumplimiento puede provocar daños al equipo o daños al medio ambiente.
This simbol indicate information that contributes to better understanding.
Este símbolo indica Información que contribuye a una mejor comprensión del producto.

7
Operation Manual
www.tecnare.com
STANDARDS
FOR CUSTOMERS IN EUROPE
This product complies with both the LVD (electrical safety) 73/23/EEC and EMC (electromag-
netic compatibility) 89/336/EEC directives issues by the commission of the European com-
munity.
Compliance with these directives implies conformity with the following European standards:
EN60065 Product safety
EN55103-1 EMC emissions
EN55103-2 EMC immunity
This product is intended for the following electromagnetic environments: E1, E2; E3 & E4.
THIS PRODUCT MUST BE EARTHED. Use only a exible cable or cord with a green and yellow core which
must be connected to the protective earthing terminal of a suitable mains plug or the earthing terminal of the
installation. The cord must be a maximum of 2m long, have a 2.5mm2 CSA, a 300/500V rating and comply with
EN50525-2-11 / H05W-F.
THIS PRODUCT IS DESIGNED FOR PERMANENT INSTALLATION. It must be tted in to a 19” rack enclosu-
re and not operated unless so installed. The rack enclosure should be open at the front and back to allow free
ventilation and movement of air through the product.
FOR CUSTOMERS IN THE USA
This product has been tested for electrical safety and complies with UL60065 7th edition
THIS PRODUCT MUST BE EARTHED. Use only a exible cable or cord with a green or green / yellow core which
must be connected to the protective earthing terminal of a suitable mains plug or the earthing terminal of the ins-
tallation. The cord must be a maximum of 6’ long, be 14AWG, have a rating SJ, SJT, SJE or 300/500V H05W-F
and be marked VW-1.
THIS PRODUCT IS DESIGNED FOR PERMANENT INSTALLATION. It must be tted in to a 19” rack enclosure
and not operated unless so installed. The rack enclosure should be open at the front and back to allow free ven-
tilation and movement of air through the product.
DECLARATION OF CONFORMITY WITH FCC RULES
We, EXELAcoustics SL, CL Encinar 282, Pol. Ind. Monte Boya, 45950 - Casarrubios del Monte (Toledo), España,
declare under our sole responsibility that this family of devices, complies with Part 15 of the FCC Rules. Operation
is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired operation.
FEDERAL COMMUNICATIONS COMMISSION NOTICE
An example of this equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential and commercial installation.
This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in ac-
cordance with the instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interfe-
rence to radio or television reception, which can be determined by turning the equipment o and on, the user is
encouraged to try and correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the distance between the equipment and the receiver.
• Connect the equipment to an outlet on a circuit dierent from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.

8
Operation Manual
www.tecnare.com
FCC Caution: Any changes or modications not expressly approved by the party responsible for compliance could
void the user’s authority to operate this equipment.
FOR CUSTOMERS IN THE CANADA
This product complies with CA /CSA C22.2 No.60065-03
Ce produit est conforme avec CA /CSA C22.2 No.60065-03
THIS PRODUCT MUST BE EARTHED. Use only a exible cable or cord with a green or green / yellow core which
must be connected to the protective earthing terminal of a suitable mains plug or the earthing terminal of the installa-
tion. The cord must be a maximum of 6’ long, be 14AWG, have a rating SJ, SJT, SJE or 300/500V H05W-F and be
marked VW-1.
CE PRODUIT DOIT ÊTRE MIS À LA TERRE. Utilisez uniquement un câble souple avec un noyau vert ou vert / jaune
qui doit être relié à la borne de terre de connecteur d’alimentation ou la borne de terre de l’installation. Le cordon
doit être un maximum de 6’ (2m) de long, 14 AWG (2.5mm2 CSA), être classé SJ, SJT, SJE ou 300/500V H05W-F
et être marquée VW-1.
THIS PRODUCT IS DESIGNED FOR PERMANENT INSTALLATION. It must be tted in to a 19” rack enclosure and
not operated unless so installed. The rack enclosure should be open at the front and back to allow free ventilation
and movement of air through the product.
CE PRODUIT EST CONÇU POUR UNE INSTALLATION PERMANENTE. Il doit être installé dans un boîtier rack
19-in. Le rack devrait être ouvert à l’avant et l’arrière pour permettre la ventilation et le mouvement d’air libre à travers
le produit .
DECLARATION OF CONFORMITY WITH CANADIAN ICES-003
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.

9
Operation Manual
www.tecnare.com
EXEL ACOUSTICS SL
CL Encinar, 282. Polígono Industrial Monte Boyal. 45950 – Casarrubios del Monte (Toledo), España (Spain).
Declara que el procesador DMA 8x8 y sus respectivas opciones, cumple con los objetivos de las Directivas:
Declare under our sole responsibility that the DMA 8x8 amplier products comply with relating Directives:
(1) Directiva de Baja Tensión - 2014/35/UE
(2) Directiva de Compatibilidad Electromagnética - 2014/30/UE
(3) Directiva RoHS - 2011/65/UE
(4) Directiva RAEE - 2012/19/UE
(1) Low Voltage Directive 2014/35/EU
(2) EMC 2014/130/EU
(3) RoHS Directive 2011/65/EU
(4) WEEE Directive 2012/19/EU
Y es conforme a las siguientes Normas Armonizadas Europeas:
In compliance with these Harmonized European Norms:
(1) EN60065 8th. Audio, video and similar electronic apparatus. Safety requirements.
(2) EN55032:2012. EMC emissions & immunity.
(3) EN55035-2017
DECLARACIÓN DE CONFORMIDAD
DECLARATION OF CONFORMITY

10
Table of Contents
www.tecnare.com DMA-8X8 DSP MATRIX | rev.:1.0
DMA-8X8
Table of Contents
IMPORTANT SAFE INSTRUCTIONS ______________________________ 4
IMPORTANTES INSTRUCCIONES DE SEGURIDAD _________________ 5
SYMBOL USED_______________________________________________ 6
STANDARDS_________________________________________________ 7
DECLARACIÓN DE CONFORMIDAD _____________________________ 9
DECLARATION OF CONFORMITY _______________________________ 9
1. Welcome and unpacking ______________________________________ 11
1.1. Welcome to Tecnare_________________________________ 11
1.2. Unpacking ________________________________________ 11
1.3. The User Guide ____________________________________ 11
2. Overview __________________________________________________ 12
2.1. Introduction _______________________________________ 12
2.2. Key features_______________________________________ 12
2.3. Front and Rear Panel________________________________ 13
3. Connections________________________________________________ 14
3.1. Audio Input Connections _____________________________ 14
3.2. Audio Output Connections ____________________________ 14
3.3. Audio Wiring Reference ______________________________ 14
3.4. ETEHERNET port for programming and control ___________ 15
3.5. RS-232 Remote control Port __________________________ 16
3.6. RS-485 Remoto control Port __________________________ 16
3.7. GPIO Remote Control Port ___________________________ 17
3.8. USB Soundcard ____________________________________ 17
4. Typical Application Example ___________________________________ 18
5. Oled Screen________________________________________________ 18
5.1. Operations ________________________________________ 19
6. Key Panel _________________________________________________ 19
6.1. Operations ________________________________________ 19
7. Technical Specications ______________________________________ 20

11
Welcome
www.tecnare.comDMA-8X8 DSP MATRIX | rev.:1.0
DMA-8x8
1. Welcome and unpacking
1.1. Welcome to Tecnare
Thank you for choosing a Tecnare®DMA 8X8 fully programmable digital audio matrix for your apli-
cation.
Please spare a little time to study the contents of this manual, so that you obtain the best possible
performance from this unit.
All Tecnare®products are carefully engineered for world-class performance and reliability.
If you would like further information about this or any other Tecnare®product, please contact us. We
look forward to helping you in the near future.
As part of a continuous evolution of techniques and standards, Exel Acoustics SL as manufacturer
of Tecnare® products reserve the right to change the specications of its products and the content of its docu-
ments without prior notice.
Updates and supplementary information are available on the Tecnare®website:
http://www.tecnare.com
Tecnare Technical Support is available at:
• (T): +34 918 170 110 - +34 918 171 001
Thank you again for placing your condence in Tecnare®products.
1.2. Unpacking
After unpacking the unit please check carefully for damage. Every Tecnare product is tested and
inspected before leaving the factory and should arrive in perfect condition. If damage is found, please notify the
carrier concerned at once. You, the consignee, must instigate any claim. Please retain all packaging in case of
future re-shipment.
1.3. The User Guide
This user manual gives a progressively more detailed description of the functions of the Tecnare
DMA 8X8 Matix processor.
A detailed explanation describes each individual function or feature with annotated images explain-
ing its use is contained in the next sections. Where appropriate, the graphical display is shown to further elab-
orate on the unit operation.
To complete the manual a reference section is included, describing the technical performance and
Mechanical drawing of the device.

12
Introduction
www.tecnare.com DMA-8X8 DSP MATRIX | rev.:1.0
DMA-8X8
2. Overview
2.1. Introduction
The DMA 8X8 is equipped with several core technical features to facilitate the work of audio engineers.
DSP-based remote audio equipment is routed, processed and controlled by computer.
The Tecnare DSP Controller is a Windows-based application, which is used to conduct conguration
and control of DSP hardware. DSP Controller has 16 built-in presets, and the modules and sequences for each pre-
set can be exibly designed in accordance with the designer’s requirements. After the design is nished, it can be
saved for future use. The sequences and parameters of DSP Controller’s built-in processing modules accord to most
of the application scenarios without any change.
DSP Controller is a full-featured application, including the parameter adjustment and peripheral acces-
sory settings of all modules, such as RS232, RS485, click-and-drag panel conguration and optional Dante network
audio control. The most interesting part is the user interface, which allows the engineer to customize user interface
so that the Integrator can edit it or the on-site technicians or end users who have no idea of relevant techniques can
operate it. Superior safety functions make it possible for the end users to access to the controls allowed by the engi-
neer or designer.
2.2. Key features
• DANTE®network audio optional
• Network TCP / IP control, can realize management of multiple devices
• 8 balanced MIC/LINE inputs (independent phantom power per input channel)
• 8 balanced LINE outputs
• Built-in ADI SHARC DSP 21489
• 4 GPIO control ports (General Purpose Input / Output)
• Programming and remote management via Ethernet Using Tecnare DSP Controller (also point-to-point,
with a direct CAT5 cable, or from an Ethernet network)
• Remote control bus for DMA digital Panel
• 16 Conguration memory presets
• Extensive DSP available:
◦ Routing matrix/mixer, from any input to any output with adjustable level, crossover points (in-
dependent mixes of dierent inputs for each output)
◦Link channel processing
◦ Level control, muter, meters, polarity and input sensitivity selector for inputs and outputs
◦Internal signal generator ( sine, white and pink noise) for input
◦Parametric EQ on inputs and outputs
◦Expander, compressor, Auto Gain Control and Feedback Inhibition for each input channel
◦ Delay and limiter setting for each output channel
◦Automixer
• USB Soundcard

13
Introduction
www.tecnare.comDMA-8X8 DSP MATRIX | rev.:1.0
DMA-8x8
2.3. Front and Rear Panel
2.3.1. The Front Panel and LED indicators
The DMA 8X8 system is designed to be mounted in a standard 19”/1HU rack enclosure.
Fig. 1 Front panel
Fig. 2 Front indicators LED
On the front panel, an LED (PWR) lights up when the unit is switched on. A second LED (STATUS)
indicates the operation status of the device.
• Status LED indicator (STATUS):
◦If the device is switched on and the device is congured, the LED continuously toggles between green
and unlit even if it is not connected to Ethernet.
◦If the device is switched on and it has been “reset to default” or “Restore to Factory Setting”, the LED
would be on permanently.
2.3.2. The Rear Panel
The rear panel of the DMA 8X8 oers 8 balanced analogue signal inputs accepting both line and
mic level signals, 8 analogue signal output, an RJ45 type connector, a GPIO for 0-5 Vdc continuous control voltage,
RS-232 & RS485 port, USB audio port and Power connector.
Fig.3 Rear panel
• Main socket: 230 Vac / 50Hz; 40W
• Ethernet Connector (RJ45): 10/100 Base-T Ethernet connector is used for IP-based PC Software and host
and third-party accessory controller.
• GPIO: 6-bit 3.81mm terminal. 4 input/output contacts to be assigned to dierent functions.
• RS-485: Used as serial communication port A-B that’s connects to a third-party control device. The Port setting
should comply with the following specications: 115200 baud (default), 8 data bits, 1 stop bit, no parity, no ow
control.
• RS-232: Used for the serial communication port Tx = sending or data output or Rx = receiving or data input
that connects to a third-party control device. The Serial Port setting should comply with the following specications:
115200 baud (default), 8 data bits, 1 stop bit, no parity, no ow control.
• USB Audio Port: USB soundcard (1-in-1-out), which can be used play audio or for recording function.
• Signal Input & Output terminal: Signal input and output connectors are 3 position screw terminal block.

14
Introduction
www.tecnare.com DMA-8X8 DSP MATRIX | rev.:1.0
DMA-8X8
3. Connections
3.1. Audio Input Connections
The rear panel of DMA 8X8 oer 8 balanced analogue MIC/LINE inputs. It features a couple of re-
movable balanced 12 pin Phoenix terminal strips.
Fig 4. Input & Output Phoenix terminal
Analog input section supports microphone or line-level signals whit nominal levels of 0dBu, 10dBu,
20dBu, 30dBu, 40dBu and 43dBu. +48VDC phantom power can be adopted for each input. Preamp gain and phan-
tom power can be easily controlled through the Tecnare DSP Controller.
Fig. 5 Input source setting on the Tecnare DSP Controller Software
3.2. Audio Output Connections
The rear panel of DMA 8X8 oer 8 balanced analogue MIC/LINE inputs. It features a couple of re-
movable balanced 12 pin Phoenix terminal strips.
Unit gain (0dB) is set through volume control, and the analogue output section is corrected to +4dBu
with 20dB headroom. That is to say, 0dBFS digital signal is equivalent to +24dBu output signal. If other signal levels
are required, you may change the volume to achieve it.
3.3. Audio Wiring Reference
• Balanced Connection
The HOT, + or ‘in phase’ connection should be made to pin + on the terminal strips or pin 2 of the
XLR connector.
The COLD, - or ‘out of phase’ connection should be made to pin - on the terminal strips or pin 3 of
the XLR connector.
GND Pin, corresponding with Pin 1 of the XLR connectors is internally connected to the chassis.
The shield of the input cable should always be connected Pin 1 to ensure the EMC performance and
regulations are met.
Fig. 6 PIN assignment DMA 8X8 Analogue Input/Output - Balanced connection

15
Introduction
www.tecnare.comDMA-8X8 DSP MATRIX | rev.:1.0
DMA-8x8
Fig. 7 Balanced wiring of dierent connectors
• Using unbalanced connection
Please note that the use of unbalanced connections is not recommended, however when connecting
the matrix to an unbalanced audio source, the signal conductor should be connected to XLR pin2. The ‘Cold’ conduc-
tor or cable screen should be connected to pin 1 with a short connection made between pin 1 and pin3 as shown in
Figure 8.
Fig. 08: Balanced to Unbalanced Analogue wiring and PIN out.
3.4. ETEHERNET port for programming and control
An RJ45 type (g.9), 10/100 Base-T connector, allows connecting the equipment to an Ethernet
network through an IP-based Windows application.
• Management of Tecnare DSP Controller application. Please, refer to the Tecnare DSP Controller soft-
ware manual for more information.
• Possibility of direct connection (point-to-point) between a computer and a DMA 8X8 device.
3.4.1. Connecting the DMA 8X8 to the Tecnare DSP controller Software
Install the Tecnare DSP Controller software in your Computer and connect it on the same network
of DMA 8X8.
Launch the software and go to “Device List” menu (g.10) on the upper right corner, and wait while
the connected DMA 8X8 appears.
In order to connect to the DMA 8X8 its IP address must be set in the same range as the network
IP address. By default it is congured with the IP address: 169.254.10.227. To change the IP address of the device,
pressing “Set IP” from the “Device List” menu and set it according your network conguration. If it is already cong-
ured correctly, then make click on “Connect” and the software will sync with the DMA 8X8.
Note: For one XLR interface, the female connects to the output device and the male
connects to the input device.
2 1
3
Pin 2 HOT +
Pin 1 Shield
Input XLR unbalanced connection

16
Display
www.tecnare.com DMA-8X8 DSP MATRIX | rev.:1.0
DMA-8X8
Once the device has been connected and synchronized, you will be able to manage and congure
all the system parámeters, identify every device connected to the network in real time together the digital wall panels
as well as load and store presets.
3.5. RS-232 Remote control Port
The built-in RS-232 port in the rear panel (g.11) allows an external device to communicate with an
DMA 8X8 unit via a serial connection.
The serial connection should comply with the following specications:
Fig. 11 RS-232 & RS-485 control Ports
3.6. RS-485 Remoto control Port
The built-in RS-485 port in the rear panel (g. 11), used for serial communication (Tx= sending or
data output; Rx = receiving or data input) allows the communications with a third-party control device.
RS485 can be used for voice tracking control (or other output commands), or for bus input control. A central com-
mand can be used to conveniently integrate it into your software.
Baud Rate: 115200 (default)
Data bits: 8
Parity: None
Stop bits: 1
Flow Control: None
Baud Rate: 115200 (default)
Data bits: 8
Parity: None
Stop bits: 1
Flow Control: None
Wiring RS232-DB9
RS232 DB9
Tx Sending or Data Output Pin 2 (RxD)
Rx Receiving or Data Input Pin 3 (TxD)
GND Pin 5 (Signal GND)
Wiring RS232-DB9
RS485 DB9
ATx Data - Pin 3 (TxD/RxD-)
B Rx Data + Pin7 (TxD/RxD+)
GND Pin 5 (Signal GND)
Fig. 9 Ethernet Port Fig. 10 Device List and IP Setting
Note: Please refer to the Tecnare DSP Controller Software for more information.

17
Display
www.tecnare.comDMA-8X8 DSP MATRIX | rev.:1.0
DMA-8x8
3.7. GPIO Remote Control Port
The rear panel of the DMA-8X8 oers 4-channels, logic input/output that allows independent input or
output conguration.
Each input is a 0-5 VDC continuous control voltage, and can be connected to an external physical
device.
Each output is a 0-5 NO/NC (normally open / normally closed) relay output. These outputs may be
assigned by the logical output control module of the software. Polarity and threshold can be dende as well.
Fig. 12 RS-232 & RS-485 control Ports
3.8. USB Soundcard
USB Soundcard is used for recording and broadcasting audio using personal computers.
The cable used is Type-B USB (Fig.13). For initial connection, “Found New Hardware” will pop up on computer
screen, and the driver will be installed automatically. After installation, USB sound card will appear in the computer
soundcard list. Users may select USB soundcard in soundcard setting at software playlist.
Fig. 12 USB Port
.

18
Software installation
www.tecnare.com DMA-8X8 DSP MATRIX | rev.:1.0
DMA-8X8
4. Typical Application Example
A capacitor microphone can be connected to the matrix, and this to an amplier. Two kinds of remote
controls can be daisy chained to various areas for personnel attending in preset setup, volume control, source selec-
tion and other functions can be performed via UDP.
Fig. 13 Application Example
5. Oled Screen
The Control Panel must be connected to the system through Ethernet and supplied by PoE.
OLED Control Panel consists of a 1.3” OLED screen and one Encoder knob. OLED screen display
will show a classied according to a menu. There is a total of three types of items including menu, buttons and pre-
sets. Conguration will be carried out through the software.
Fig. 14 Oled Screen - Panel B-DMA8X8

19
Software Installation
www.tecnare.comDMA-8X8 DSP MATRIX | rev.:1.0
DMA-8x8
5.1. Operations
1. It Display panel name and IP address on the screen and turn the knob left or right to switch
menu.
2. Press the encoder button, and the second row on the menu interface starts to ash, which
indicates that it enters edit mode.
3. Turn the encoder left or right to change the value.
6. Key Panel
The Control Panel must be connected to the system through Ethernet and supplied by PoE.
It has 8 keys and one rotary knob on key panel. The knob is used to adjust gain, and 8 keys can be
used to set dierent functions through programming. These include volume adjustment, mute, preset and command.
Conguration will be carried out through the software.
Fig. 15 Key Panel Panel A-DMA8X8
6.1. Operations
1. Key indicator stays on, which indicates the key is congured with mute function.
2. Key indicator keeps ashing, which indicate the key is congured with gain function. To set
the gain, use the rotary knob. It can be set between -72dB and +12dB. 13 LEDs indicators around
the rotary knob indicate gains.
3. A sudden ash happens when pressing the key indicator indicates the key is congured with
preset or command function.

20
Software Installation
www.tecnare.com DMA-8X8 DSP MATRIX | rev.:1.0
DMA-8X8
7. Technical Specications
AUDIO
Input impedance 9.4 kΩ balanced
Output impedance 102 Ω balanced
Input Gain 0/6/12/18/24/30/36/42/48 dBu
Input Level 0/-6dB
Max Level +24dBu
Frequency Response 20Hz - 20kHz+/-0.2dB
THD+Noise 0.003% @4 dBu
Dynamic Range 110 dB
Bacground Noise (A-weighted) -91 dB
Channel Isolation 108 dB @1kHz
Phantom Power +48V
INDICATORS, CONTROL & COMMUNICATIONS
Front panel:
Monitoring facilities Power
Status
Rear panel:
Network and control Ethernet
Control Protocols RS-232, RS-485 and UDP (transport layer)
DSP
Processor ADI SHARC 21589
Sample Rate 48khz/24bits
Work Mode Stereo, Bridge, Mono, Free Matrix
System Delay <3 ms
POWER SUPPLIES
Input voltage AC 230 v / 50-60 Hz nominal +/- 10% (110v optional using TRF-
Max Power Consumption <40 W
THERMAL
One variable speed fan. Airow is from right to left.
PHYSICAL
Height 1HU, 44mm
Width 482mm, 19” (front panel)
440mm, 17,32” (rear chassis)
Depth 200mm, 7,87” (behind rack)
Weight 3 Kgs, 6.61 pounds
CONNECTIONS
Mains IEC-C14
Audio input 2 x 12 pin Phoenix Terminal
Output 2 x 12 pin Phoenix Terminal
USB Type B (peripheral type)
Network and Com. 1x RJ45 socket; TCP/IP, 1000base-T/100base-TX
RS485/RS232 via 3 input/output Phoenix Terminal
GPIO via 6 input/output Phoenix Terminal
Other manuals for ARRAY Series
1
This manual suits for next models
1
Table of contents
Popular Matrix Switcher manuals by other brands

Shinybow USA
Shinybow USA SB-5582 instruction manual

SY
SY SY-MUHD-44 user manual

Guntermann & Drunck
Guntermann & Drunck ControlCenter-Digital-80 installation guide

CYP
CYP Elpro Video Labs CDPS-UC4H4HFS Operation manual

Extron electronics
Extron electronics ISM 182 Specifications

CYP
CYP PU-8H8HBTL Operation manual