TECO SG2 Series User manual

TECO SG2 Micro-Controller
Operation Manual
Version:First Edition
Y3
Output 4 x Relay / 8A
SG2-8ER-A
AC 100~240V
Run
AC 100~240V
Run
X2X1
Input
4×AC
IC
-+
DC 24V Input 8 x DC
T6
T5
Run
T4
T3
20KT-D
T2T1
Output 8 x Tra. / 0.5A
Y3
Y1
Output 4 x Relay / 8A
LN
T8
T7
SG2-8ER-A
DC 24V Input 12 x DC(A1...A4=0~10V)
IA
Q6Q5Q4Q3
SG2-20HR-D
Q2Q1
Output 8 x Relay / 8A
I7 I8 I9I6I5I4I2 I3I1
Y3
Y1
Output 4 x Relay / 8A
NL
Q8Q7
SG2-8ER-A
IB
A2
A1I7 I8
Run
SG2-12KR-D
Q4Q3
I6I5I4I2 I3
Q2
Q1
I1-+
Output 4 x Relay / 8A
X2X1
Y4Y3
Y2Y1
Output 4 x Relay / 8A
Run
A3 A4
SG2-8ER-A
Input
4×AC
X4X2X1 X3X4X3 Input
4×AC
Y4Y3
Y2Y1
Output 4 x Relay / 8A
Y4
Y2
LN
Run
AC 100~240V
SG2-8ER-A
Y4Y3
Y2Y1
Output 4 x Relay / 8A
Y4
Y2
NL
Run
AC 100~240V
SG2-8ER-A
X4
X2X1 X3
X4
X3
Y4
Y2Y1
Run
Input
4×AC
Y3
Output 4 x Relay / 8A
Input
4×AC
SG2-8ER-A
Input
4×AC
SG2-12HR-D
Q4Q3
I6 A1 A2I5I3 I4
Q2Q1
I1 I2
-
+
Output 4 x Relay / 8A
DC 24V Input 8 x DC(A1,A2 0~10V)
X4
X2X1 X3
Run
Y2
Y4Y3
Input
4×AC
Output 4 x Relay / 8A
SG2-8ER-A
Y1
AC 100~240V
LN
A2I6 A1
I5I3 I4I2I1
-
+
DC 24V Input 8 x DC(A1,A2 0~10V)
X4X3X1 X2
NAC 100~240V
L
Input
4×AC
X4
X2X1 X3
Y4
Y2Y1
Run
AC 100~240V
LN
X4X2X1 X3
LN
AC 100~240V

Chapter 12 Technical Specification 130
20KR-12
D
◎12* 8 Relay 4 ◎◎◎
Standard Variant without up-cover
20CR-A ◎12 8 Relay ◎
20CR-D ◎12* 8 Relay 4 ◎◎
20CT-D ◎12* 8 Transisto
r
4 ◎◎◎
20CR-12D ◎12* 8 Relay 4 ◎◎
High-speed communication Variant
20VR-D ◎12* 8 Relay 4 ◎◎◎◎◎
20VT-D ◎12* 8 Transisto
r
4 ◎◎◎◎◎◎
8ER-A ◎4 4 Relay
8ER-D ◎44Relay
Expansion
8ET-D ◎44Transisto
r
◎: YES
*: The input points consist of the ones having analog input function.
12-3 Power Supply Standard Discrete Input
.12-3-1 AC/DC 24V
Item
SG2-10HR-A
SG2-10KR-A
SG2-10CR-A
SG2-20HR-A
SG2-20KR-A
SG2-20HR-D
SG2-20KR-D
SG2-20HT-D
SG2-20KT-D
SG2-12HR-D
SG2-12KR-D
SG2-12CR-D
SG2-12HT-D
SG2-12KT-D
SG2-12CT-D
Operation
voltage
AC 100~240V AC 100~240V DC 24V DC 24V
Voltage Range AC 85~264V AC 85~264V DC 20.4~28.8V DC 20.4~28.8
Operation
frequency
50 / 60 Hz 50 / 60 Hz
Frequency
limits
47~63Hz 47~63Hz
Momentary
interrupt
10 ms(half period) /
20 times (IEC
10 ms(half period) /
20 times (IEC
1ms/10times (IEC
61131-2)
10ms/10times(IEC
61131-2)

TECO Electric & Machinery Co., Ltd
Safety Precaution
.ⅠPrecaution for Installation:
Never install the product in the environment beyond the one brochure and user
manual specified, such as high temperature, humidity, dust, erosive gas,
vibration, impact condition resulting in the risk of inductive electricity, fire and
error operation.
Please exactly comply with the installation instruction in the user manual, or the
undesired situation as falling down, accident or error operation would happen to
the SG2.
Pay close attention to the cable and conductor incidentally fall into the module
to prevent fire, trouble and wrong action.
.ⅡPrecaution for Wiring:
Connect Class 3 grounding in accordance with the Electricity Engineering
Regulations. NO grounding or improper grounding might lead to troubles such
as electric shock and error operation.
Apply the rated power supply and specified cables. Wrong power supply would
render fire.
The wiring shall be carried out by the certified electrician pursuant to the
provisions set forth in the Electricity Engineering Regulations.
Improper wiring would lead to fire, trouble, and induction electricity.
.ⅢPrecaution for Operation:
When the power is on, never contact the terminal to avert electrical induction.
It is strongly recommended to add the safety protection such as the emergence
stop and external interlock circuit to prevent the SG2 from trouble and
mechanical damage.
Run the SG2 after safety confirmation. Error operation will result in mechanical
damage.
Please pay attention to the power on procedure. Wrong process flow would lead
to mechanical damage or other hazards.

Cha
p
ter 1 General
Cha
p
te
r
2O
p
eration Precaution
Cha
p
ter 3 S
y
stem confi
g
uration
Chapter 4 Installation and wiring
Chapter 5 Operation Flow
Chapter 6 LADDER Instruction Description
Chapter 7 FBD Block Description
Chapter 8 System Design
Chapter 9 Spare Progra
m
Chapter 11 Inspection and Maintenance
Chapter 10 Test Run
Chapter 12 Technical Specification
Chapter 13 20 points V TYPE Function
Appendix

List
Chapter 1 General-------------------------------------------------------------------------------------------1
Chapter 2 Operation Precaution---------------------------------------------------------------------------3
2-1 Installation Environment-------------------------------------------------------------------3
2-2 Installation-----------------------------------------------------------------------------------3
2-3 Wiring----------------------------------------------------------------------------------------3
2-4 Static Electricity-----------------------------------------------------------------------------3
2-5 Cleanness-------------------------------------------------------------------------------------3
2-6 Storage----------------------------------------------------------------------------------------4
2-7 Over-current Protection--------------------------------------------------------------------4
Chapter 3 System configuration---------------------------------------------------------------------------5
3-1 Basic System Configuration ----------------------------------------------------------------5
3-2 Configuration for computer Connection and Spare Program Cartridge --------------6
Chapter 4 Installation---------------------------------------------------------------------------------------8
4-1 Installation Environment---------------------------------------------------------------------8
4-2 Installation and wiring method--------------------------------------------------------------8
4-2-1 H type-----------------------------------------------------------------------------------8
4-2-2 K type----------------------------------------------------------------------------------13
4-2-3 C type----------------------------------------------------------------------------------18
4-2-4 E type----------------------------------------------------------------------------------21
Chapter 5 Operation Flow--------------------------------------------------------------------------------27
5-1 After Power Supply Connection----------------------------------------------------------27
5-2 dealing in power loss-----------------------------------------------------------------------28
5-3 RUN-STOP-RUN operation-----------------------------------------------------------28
Chapter 6 Description for LADDER Instruction------------------------------------------------------29
6-1 Basic Instruction-----------------------------------------------------------------------------29
6-1-1 Instructions with logical operand--------------------------------------------------29
6-1-2 Instructions without operand-------------------------------------------------------29
6-1-3 Connection signal--------------------------------------------------------------------29
6-2 Example for basic instruction--------------------------------------------------------------29
6-3 Application Instruction----------------------------------------------------------------------31
6-3-1 General counter-----------------------------------------------------------------------31
Counter mode 1----------------------------------------------------------------------32
Counter mode 2----------------------------------------------------------------------33
Counter mode 3----------------------------------------------------------------------33
Counter mode 4----------------------------------------------------------------------33
Counter mode 5----------------------------------------------------------------------33
Counter mode 6----------------------------------------------------------------------34
Counter mode 7----------------------------------------------------------------------35
Counter mode 8----------------------------------------------------------------------35
6-3-2 Timer-----------------------------------------------------------------------------------36
Timer mode 1-------------------------------------------------------------------------37
Timer mode 2-------------------------------------------------------------------------38
Timer mode 3-------------------------------------------------------------------------38

Timer mode 4-------------------------------------------------------------------------38
Timer mode 5-------------------------------------------------------------------------39
Timer mode 6-------------------------------------------------------------------------40
Timer mode 7-------------------------------------------------------------------------40
6-3-3 RTC instruction-----------------------------------------------------------------------40
Weekly Mode-------------------------------------------------------------------------40
Year-Month-Day Mode------------------------------------------------------------- 40
Mode 1---------------------------------------------------------------------------41
Mode 2---------------------------------------------------------------------------43
Mode 3---------------------------------------------------------------------------46
6-3-4 Analog Comparator------------------------------------------------------------------47
6-3-5 HMI------------------------------------------------------------------------------------48
6-3-6 PWM Output function-------------------------------------------------------------- 61
6-3-7 I/O Link Function--------------------------------------------------------------------63
6-4 Operation Method---------------------------------------------------------------------------64
6-4-1 Original Screen----------------------------------------------------------------------65
6-4-2 Main Menu---------------------------------------------------------------------------71
Main Menu LADDER--------------------------------------------------------------71
Function Block program input----------------------------------------------------78
RUN or STOP------------------------------------------------------------------------87
Other menu item---------------------------------------------------------------------87
Chapter 7 FBD Block Description---------------------------------------------------------------------- 92
7-1 Coil Block Diagram------------------------------------------------------------------------ 92
7-2 Edit Block------------------------------------------------------------------------------------94
7-3 Function Block------------------------------------------------------------------------------98
7-3-1 Common Counter Function Block------------------------------------------------99
7-3-2 High Speed Counter Function Block--------------------------------------------100
7-3-3 Timer Function Block-------------------------------------------------------------101
7-3-4 RTC Comparator Function Block-----------------------------------------------103
7-3-5 Analog comparator Function Block---------------------------------------------105
7-4 FBD Block Resource----------------------------------------------------------------------105
7-5 FBD Edit Method--------------------------------------------------------------------------105
7-5-1 The origin screen ------------------------------------------------------------------106
7-5-2 Main menu screen------------------------------------------------------------------110
◎FBD For Main Screen----------------------------------------------------------111
Output coil display-------------------------------------------------------------111
Nr Input terminal Screen------------------------------------------------------113
Edit Screen for Bn input terminal--------------------------------------------114
HMI Setting Screen------------------------------------------------------------115
I/O LINK setting screen-------------------------------------------------------115
PWM Setting screen-----------------------------------------------------------116
SHIFT setting screen-----------------------------------------------------------117
◎PARAMETER of Main Menu-----------------------------------------------118
Chapter 8 System Design------------------------------------------------------------------------------- 120

8-1 Procedure for system design-------------------------------------------------------------120
8-2 Consideration for System Design-------------------------------------------------------121
8-3 Code Distribution for Relay--------------------------------------------------------------121
Chapter 9 Spare Program--------------------------------------------------------------------------------122
9-1 Spare Program Cartridge (PM05)------------------------------------------------------- 122
9-2 Computer Write Software (Client)------------------------------------------------------ 123
Chapter 10 Test Run-------------------------------------------------------------------------------------124
10-1 Confirmation before Test Run----------------------------------------------------------124
10-2 Procedure of Test Run-------------------------------------------------------------------125
Chapter 11 Inspection and Maintenance--------------------------------------------------------------126
11-1 Periodic Inspection-----------------------------------------------------------------------126
11-2 Trouble Shooting-------------------------------------------------------------------------126
Chapter 12 Technical Specification--------------------------------------------------------------------127
12-1 General Specification--------------------------------------------------------------------127
12-2 I/O System Specification----------------------------------------------------------------128
12-3 Dimension Diagram----------------------------------------------------------------------129
Appendix Application Illustration--------------------------------------------------------------------- 132

1-1
Chapter 1 General
SG2 is a tiny smart PLC having 44 points O/I system, applying ladder graphic program and FBD
program, and applicable to the small-scale automatic operation. SG2 can expand 3 groups of
4-input-4-output module, one 4AI Module, one communication Module. The smart mobility and
supremacy the SG2 inheres are greatest assistance for you to considerably save both time and cost in
operation. The special features the SG2 owns are presented below:
Feature 1
Complete product line:
(1) Dimension for the super-mini standard 10/12/20 points
a) 10/12 points variant:72×90×59.6 (mm)
b) 20 points variant:126×90×59.6 (mm)
(2) Max. 3 group I/O Expansive Module, one 4AI Module,one communication Module: 38×90×59.6
(mm),
(3) Versatile RTC and analog input (10 bits)
(4) Low price variant without LCD/Keypad and blind variant (without up cover)
Feature 2
Selective input and output
(1) Input: AC 85 ~ 264V or DC 21.6~ 26.4V or DC9.6~14.4V
(2) Output: Relay or Transistor
Feature 3
Easy to learn and to operate
(1) Built-in 12 x 4 LCD display and 8 keys for inputting ladder program
(2) The computer compiled programs are applicable to WIN 32 platform (Windows
95/98/ME/NT/2000/XP)
(3) Programming by PDA, Monitoring by PDA
(4) Seven languages: English, French, Spanish, Italian, German, Portuguese and Simplified
Chinese.

1-2
Feature 4
Ease installation and maintenance
(1) Screw installation
(2) DIN rail installation
(3) Spare program cartridge PM05 (optional)
(4) LCD display shows online input and output in operation
Feature 5
(1) Multiple outputs: Relay output, Max. 8A/points (resistive load). Transistor output
0.5A/Point(resistive load)
(2) It can directly drive 1/3 HP motor.
(3) Sufficient program memory and abundant Instruction
1Max. 200 step Ladder Instruction input or 99 blocks of FBD.
2Many built-in Application Instructions
◎ Timer
◎ Counter
◎ Time comparison
◎ Analog comparison
◎ Upper and lower differentiation
◎PWM Function
◎I/O LINK Function
◎REMOTE I/O Function
◎HMI Function
(4) Internationally certified by:
1CE mark
2cUL/UL

2-1
Chapter 2 Operation Precaution
2-1 Installation Environment
The following environments are not favored to install SG2:
◎ The area is under direct sunshine or the ambient temperature is beyond -20-55℃.
◎ The relative humidity exceeds 5-90%, the temperature is subject to rapid change,
susceptible to condensation.
◎ The area contains inflammable or erosive gases
2-2 Installation
◎ Firmly fasten the cable with lock screws to ensure no poor contact.
Installation drawing
2-3 Wiring
◎ The I/O signal cables shall not be routed parallel to the power cable, high current cable or
in the same high current cable trays to avoid the signal interference.
2-4 Static Electricity
◎ In the extremely arid area, the humans’body is susceptible to generate of static electricity.
Never touch the SG2 with hands to avert static damage to the SG2.
2-5 Cleanness
Use the clean and dry cloth to wipe the surface of the SG2. It is prohibited to clean the SG2

2-2
with water or volatile solvent to prevent structure deformation and discoloration.
2-6 Storage
◎ The time memory of SG2 RTC applies super capacity which is susceptible to high
temperature and humidity. The SG2 shall be kept away from the said place.
2-7 Over-current Protection
◎ The SG2 is not incorporated a protective fuse at the output terminal. To avoid the short
circuit on the load side, it is recommended to cable a fuse between each output terminals
and loads.

3-1
Content
3-1 Basic configuration
3-2 Configuration of computer connected and spare program cartridge.

3-2
Chapter 3 System Configuration
3-1 Basic System Configuration
SG2 10/12 Points:SG2expandI/O&COMM:
Expansion Type Blind Type Bare board Type
(economical type)
10HR◎-A 10KR◎-A 10CR◎-A 8ER◎-A ◎4AI ◎Profibus
12HR◎-D 12KR◎-D 12CR◎-D 8ER◎-D ◎Modbus ◎TCP/IP
12HT◎-D 12KT◎-D 12CT◎-D 8ET◎-D ◎Devicenet
12HR◎-12D 12KR◎-12D 12CR◎-12D
I1
DC 24V Input 8 x DC(A1,A2 0~10V)
Output 4 x Relay / 8A
SG2-12KR-D
Q1
DC 24V Input 8 x DC(A1,A2 0~10V)
Output 4 x Relay / 8A
Q1 Q2 Q3 Q4
SG2-12HR-D
Q1 Q2
Q2 Q3 Q4
Run
+-
+-I1 I2 I4I3 I5 A1I6 A2 +-
I2I1 I4I3 I5 A2A1I6 Input
4×AC
AC 100~240V
Run
Y2
Y4
NL
Y1
Y3
SG2-8ER-A
Output 4 x Relay / 8A
Q4Q3
X4
X3X2X1
I6I5I4I3I2
DC 24V Input 8 x DC
IA-+
T6T5
Run
T4T3
20KT-D
T2T1
Output 8 x Tra. / 0.5A
I7 I8 I9I6I5I4I2 I3I1 IC
T8T7
IB
A2
DC 24V Input 12 x DC(A1...A4=0~10V)
+- I1 I3I2 I4 I5 I6 I8I7 A1
Output 8 x Relay / 8A
Q1 Q2
SG2-20HR-D
Q3 Q4 Q5 Q6
A4A3
Q7 Q8
SG2 20 points:
Expansion Type High-Speed Type
◎20HR-A 20VR◎-D
◎20HR-D 20VT◎-D
◎20HT-D
20◎HR-12D
Blind Type Bare board Type (Economic)
20◎KR-A 20CR◎-A
◎20KR-D ◎20CR-D
20◎KT-D 20C◎T-D
20◎KR-12D 20◎CR-12D

3-3
3-2 Configuration for computer Connection and Spare Program Cartridge
(1) Link the computer and SG2 with Client Cable. Through the Client software, the computer is
ready to read and write the programs contained in SG2 and oversee on line operation in SG2. (See
the figure below)
Figure 3-2-1
Note: SG2 PDA software suits PDA based on WIN CE and matching with the connector
SG2-PL02, Such as HP2200, 2190 and 2210, etc.
(2) Plug PM05 into the SG2 which is able to load and recover the programs from the PM05.
(See the figure below)
PC
Client Cable
PM05 (spare program cartridge
PDA
232-USB converter
Client Software
Computer

3-4
Figure 3-2-2

4-1
4.1 Installation Environment
The SG2 PLC is prohibited to be installed under the following environments:
◎The ambient temperature is beyond -20℃~55 .℃
◎The relative humidity exceeds 5~90%.
◎Area is brimful of dust, salt and iron powder.
◎Under direct sunshine.
◎The environment is subject to frequent vibration and impact.
◎The area contains erosive and inflammable gases susceptible to fire.
◎The area is abundant of volatile oil gas, organic solvent, ammonia, electrolytic gas.
◎Poor ventilation or close to heating source.
4.2 Installation and wiring method
Warn:
Such product users should have special skill about PLC system. Only the persons
qualified are access to control, install and use the products.
The operator and the equipment will be damaged if neglect such warning.
Precaution for Wiring
◎The I/O signal wire shall not be routed in parallel to the power wire or placed in the
same tray.
◎Adopt 0.75-3.5mm2 cable as the external wire.
◎Apply 4~6kgf.cm torques to tighten the lock screws.
Chapter 4 Installation

4-2
4-2-1 H-TYPE PRODUCTS:
SG2-12H#-D //12H#-12D
SG2-20##-D //20##-12D
SG2-10HR-A//10HR-24A
SG2-20HR-A//20HR-24A
WARN:
Unintentional equipment operation.
The application of this product requires know-how in design and program of control
system. Only persons qualified are allowed to program, install and apply this product.
Failure to follow this instruction will result in death, serious injury or equipment
damage.
DC 24V Input 12 x DC(A1...A4=0~10V)
SG2-20HR-D
Output 8 x Relay / 8A
Q1
+-
Q7Q3Q2 Q4 Q5 Q6 Q8
I3 I4 I5 I6I2I1 A4
A2 A3A1I8
I7
Q2
Output 4 x Relay / 8A
Q1 Q4Q3
SG2-12HR-D
DC 24V Input 8 x DC(A1,A2 0~10V)
-I1+I6I3I2 I4 I5 A1 A2
-①Power supply
terminals
-②LCD display
-③Input terminals
-④Retractable
mounting feet
-⑤Delete key
-⑥Selection key
-⑦Direction
keys(left/right/up/down)
-⑧Ok key
-⑨Escape key
-⑩EEPROM
cartridge or PC cable
connection
-Output terminals
AC ..V Input ......
I1
I3
DC V Input
NL
+-I2I1
AC ..V INPUT ......
I2 I4I3 I5 I6
I2I1 I3 I4
LN IA
I8 I9 IC
IB
I6
I5 I7
DC V INPUT
A2I5 I6 A1I4
I1 I2 I4
I3+- A1I8 A4
A2 A3
I5 I6 I7

4-3
0.14...1.5
26...16
0.14...2.50.14...0.75
2
mm 0.14...1.5 0.14...2.5
26...16
3.5
(0.14in)
AWG
C
26...18
lb-in 5.4
C
Nm
26...14
0.6
26...14
DANGER:
HAZARDOUS VOLTAGE
Cut off all power before maintenance.
Electric shock will result in death or serious injury.
Input 12/24V DC:
DC V Input
I3 I4I2I1
-
+
DC V INPUT
A1I6I5 A2 +- I4 I5 I6I3I1 I2 A4A2 A3A1I8I7
+-A3
A1
+-A4A2
A2A1
SG2-12H# -D
SG2-12H# -12D
SG2-20## -D
SG2-20## -12D

4-4
A1
DC V Input
I5
+-I1 I2 I3 I4 A2I6 A1 A3A2 A4
Input 24VAC or 100…240VAC:
AC ..V Input ......
NL
AC ..V INPUT ......
LI2I1 I4I3 I5 I6 I7 I9I8I4I1 I3I2 I5 I6NIBIA IC
Output (Relay):
Output 4 x Relay / 8A
Q1 Q4Q3Q2
Output 8 x Relay / 8A
Q6Q2 Q3Q1 Q4 Q5 Q8Q7
Output (Transistor):
OUTPUT 8 x TR / 0.5A
Q1 Q2
Q4Q3Q1 Q2
OUTPUT 4 x TR / 0.5A
-
+-
+-
+
-
++
-
+-Q8Q7Q5 Q6Q3 Q4 +--
++ -++ --
+-
SG2-10HR-A/10HR-24A SG2-20HR-A/20HR-24A

4-5
I/O link or Remote I/O:
(Only products, SG2-20VR-D/20VT-D/20VR-12D/20VT-12D are available.)
A2A3 S
A4
A1 A2 A1
RS485
BA A3 S
A4
RS485
BA A3A1 A2 AB
RS485
A4 S
①-1A quick-blowing fuse, circuit-breaker or circuit protector
②-Surge absorber (36V DC)
③-Surge absorber (400VAC)
④-Fuse, circuit-breaker or circuit protector
⑤-Inductive load
⑥-Only short circuit the first product and the last product
⑦-Comply with standard : EIA RS-485.When I/O link, the net can connect 8 products
in max.(ID:1~8).When Remote I/O is available, it only can connect 2 products in
max.(MASTER & SLAVE)。
Communicate with SG2 CLIENT Software:
Q2Q1 Q4Q3
Output 4 x Relay / 8A 1Q2Q1
Output 4 x Relay / 8A
SG2 CLIENT
V...
PC
3
Q1 Q2 Q4Q3 4
DC 24V Input 8 x DC(A1,A2 0~10V)
I6
DC 24V Input 8 x DC(A1,A2 0~10V)
I1+-A2I2 I3 I5 I6I4 A1
2
I3I2I1
-
+I5I4
DC 24V Input 8 x DC(A1,A2 0~10V)
A2A1 -
+I1 I2 A2I6I5I3 I4 A1
SG2-12HR-D SG2-12HR-D SG2-12HR-D
I1 [ T1
[ T2
T1 [Q1
Communicate with PM05:
Other manuals for SG2 Series
3
Table of contents
Popular Microcontroller manuals by other brands

TENX TECHNOLOGY
TENX TECHNOLOGY TM57PE10 user manual

Parallax
Parallax WIZnet W5200 quick start

NXP Semiconductors
NXP Semiconductors freescale semiconductor ColdFire MCF51CN128... Reference manual

onsemi
onsemi FUSB15201P user manual

Ultrahaptics
Ultrahaptics STRATOSTM INSPIRE user manual

Texas Instruments
Texas Instruments CC3235MODSF SimpleLink user guide

ON Semiconductor
ON Semiconductor EVBUM2306/D user guide

Altera
Altera Stratix III Design guidelines

Texas Instruments
Texas Instruments SimpleLink CC2650STK Getting started

Lamina
Lamina Titan White Developer Kit manual

HARDKERNEL
HARDKERNEL ODROID-VU-7-A Plus manual

Silicon Laboratories
Silicon Laboratories C8051F33 Series user guide