© by WilTec Wildanger Technik GmbH Item 55550 Page 2
http://www.WilTec.de
http://www.aoyue.eu 01 2022-1
http://www.teichtip.de
The information contained in this document may alter at any time without previous notice. It is prohibited
to copy or spread any parts of this document in any way without prior written allowance. All rights re-
served.
The WilTec Wildanger Technik GmbH cannot be held accountable for any possible mistakes in this
operating manual, nor in the diagrams and figures shown.
Even though, the WilTec Wildanger Technik GmbH has undergone biggest possible efforts to ensure
that the operating manual is complete, faultless, and up to date, mistakes cannot be entirely avoided.
If you should find a mistake or wish to make a suggestion for improvement, we look forward to hearing
from you.
Send an e-mail to:
or use our contact form:
https://www.wiltec.de/contacts/
The most recent version of this manual in various languages can be found in our online shop via:
https://www.wiltec.de/docsearch
Our postal address is:
WilTec Wildanger Technik GmbH
Königsbenden 12
52249 Eschweiler
Germany
Do you wish to pick goods up? Our pick-up address is:
WilTec Wildanger Technik GmbH
Königsbenden 28
52249 Eschweiler
Germany
To shorten the waiting time and allow for a rapid on-site transaction, we ask you to call us previously or
placing your order via the webshop.
E-mail: service@wiltec.info
Tel: +49 2403 55592–0
Fax: +49 2403 55592–15
To return orders for exchange, repair, or other purposes, please use the following address. Attention!
To allow for a smooth execution of your complaint or return, it is important to contact our customer
service team before returning the goods.
Returns Department
WilTec Wildanger Technik GmbH
Königsbenden 28
52249 Eschweiler
E-mail: service@wiltec.info
Tel: +49 2403 55592–0
Fax: +49 2403 55592–15

© by WilTec Wildanger Technik GmbH Item 55550 Page 3
http://www.WilTec.de
http://www.aoyue.eu 01 2022-1
http://www.teichtip.de
Introduction
Thank you for purchasing this quality product. To minimise the risk of injury we urge that our clients
take some basic safety precautions when using this device. Please read the operation instruc-
tions carefully and make sure you have understood its content.
Keep these operation instructions safe.
Unpacking
Inform your vendor in case any piece should be damaged.
Caution
•For your own safety, contact an electrical professional in case of questions and problems.
•Do not connect the device to the power supply before the all parts have been installed.
•Only connect the pump to a (earthed) shockproof socket. This type of socket must comply with
the respective national guidelines (VDE, EN, IEC etc.). Make sure that the neutral conductor
(PE conductor; protected earth) leads continuously to the pump.
•Make sure that the voltage of the pump and that of the power supply match.
•Electrical installations in garden ponds must comply with national and supranational regulations.
•Only operate the pump when nobody is in the water.
•Do not carry or pull the pump by the power cord; the cable should neither overheat nor touch
sharp edges.
•The pump must not be put into operation if the cable or the housing is damaged.
•Only pump water with this pump.
•Attention: The pump switches off automatically in the event of overvoltage or dry running with-
out water.
•The controller is not designed to be waterproof. It must therefore be kept in a dry and ventilated
place.
Application
For garden ponds, rockeries, aquariums with fish and other sea animals
Features
•High flow rate, 10 different setting levels
•Robust filter housing made of stainless steel
•Special housing that prevents clogging
•New energy-efficient frequency conversion technology
•Suitable for both freshwater and saltwater aquarium
•Ceramic shaft, for a long service life
•Automatic dry run detection, with alarm function
Installation
1. Notify your vendor immediately if there are external damages.
2. Compare the line voltage (V) and frequency (Hz) of your electrical circuit with the data on the
model plate; these data must agree.
3. When connecting the pipe, drainage air in the pipe as far as possible. (Caution: There must be
no air in the pipes; otherwise, the dry run protection might be activated.)
4. Attention: The pump must be at a position that is at least 20 cm below the water level; the
pump must continuously be surrounded completely by water.

© by WilTec Wildanger Technik GmbH Item 55550 Page 4
http://www.WilTec.de
http://www.aoyue.eu 01 2022-1
http://www.teichtip.de
5. Do not place the pump directly in the pond floor mud, place it on a raised surface.
6. Connect the pump with the controller of four core wire (Fig. 1, 1), lock the nut (Fig. 1, 2).
7. Connect the power supply of the controller.
Controller operation instructions
1. On/off
Plug in the device and touch to switch the pump on and off.
If the device is not operated for a long time, please unplug it.
2. Flow rate adjusting
Press or to adjust the flow rate; the device disposes of 10 levels, and
the display screen will show “SP01”–“SP10.” For detailed information please refer
to the parameter list:
Power supply
Level
Power (W)
Flow rate (ℓ⁄h)
Flow head (m)
220–240 V/50 Hz
1
80
13,000
2.8
2
100
14,000
3.4
3
130
15,500
4.0
4
160
17,000
4.5
5
200
18,000
5.1
6
240
19,000
5.8
7
285
20,500
6.5
8
335
22,000
7.2
9
380
23,500
7.8
10
450
26,000
8.5
3. Feeding mode
Press for 3 s to enter the time delay start mode, and the screen will show “FD10.” The device will
start to work after 10 min. Again press for 3 s to quit the feeding mode.
4. LOCK function
Long press to lock the keys, and the screen will show “LOC.” Long press to unlock the keys.
5. Automatic memory function

© by WilTec Wildanger Technik GmbH Item 55550 Page 5
http://www.WilTec.de
http://www.aoyue.eu 01 2022-1
http://www.teichtip.de
When the controller powers off accidentally, the device will save the last working condition automatically,
and will return to these conditions after the device will have been re-powered on. Thus, the settings will
be saved when there is a power failure e. g.
6. Alarm function
The pump will automatically stop working if running without water more than 30 s, then re-start after 3 s,
repeating that 5 times and then power off permanently, reporting the error “ER03”; when the pump au-
tomatically stops working in case it is blocked, the display screen will show “ER02.” The pump will au-
tomatically re-start after the error will have been repaired.
7. Instruction code definition and trouble shooting
Code
Definition
Status
Trouble shooting
P000
Power
Normal
―
SP01–10
Flow rate level
Normal
FD10–01
Feeding mode
Normal
LOC
Lock
Normal
ER01
Overvoltage or undervolt-
age
Abnormal
Check the input voltage.
ER02
Pump lock protection
Abnormal
Check the pump whether it is stuck.
ER03
Pump idling protection
Abnormal
1. Check the pump whether it works without water.
2. Check whether there is air in the pipe.
ER04
Overheating
Abnormal
Clean the pump.
ER05
Short-circuit
Abnormal
Check the controller.
Maintenance and cleaning
Before any maintenance, cut off the power supply. After a certain time, if the pump has operated con-
tinuously, there will be much rubbish on the rotor part. If you do not clean regularly, this will not only
affect the normal operation, but can also damage the pump itself. So, you need to clean the rotor parts
regularly. Proceed as follows:

© by WilTec Wildanger Technik GmbH Item 55550 Page 6
http://www.WilTec.de
http://www.aoyue.eu 01 2022-1
http://www.teichtip.de
1. Use a hexagonal screwdriver to screw off the 4 screws on the filter cover (see Fig. 1 and 2).
Screw off the base plate (see Fig. 2) and take down the filter cover and base plate. Fig. 3 shows
the pump after this step.
2. Use a hexagonal screwdriver to screw off the 4 screws on the impeller chamber (see Fig. 4);
take off the impeller chamber. Fig. 5 shows the pump after this step.
3. Take off the rotor, clean or replace it.
•If the pump is not used for a long time, please take out the pump from the water, let it run in
clean water for a moment, and then clean the inner part. Dry all parts before stocking and stock
it at a secure place.
•When the temperature is lower than 0 ℃, please take out the pump from water immediately to
prevent any freezing damages.
Explosion view and part list
№
Name
№
Name
№
Name
1
Screw M6×40
7
Pump rotor
13
Back cover
2
Filter basket
8
Gasket
14
Screw M6×20
3
Outlet
9
Ceramic bearing
15
Base plate
4
O-ring
10
Body
16
Screw M6×40
5
Impeller chamber
11
Screw M6×35
6
Front impeller chamber
12
O-ring

© by WilTec Wildanger Technik GmbH Item 55550 Page 7
http://www.WilTec.de
http://www.aoyue.eu 01 2022-1
http://www.teichtip.de
Disposal regulations
EU guidelines regarding the disposal of scrap electric appliances (WEEE, 2012/19/EU) were imple-
mented in the law related to electrical and electronic equipment and appliances.
All WilTec electric devices that fall under the WEEE regulations are labelled with the crossed-out
wheeled waste bin logo. This logo indicates that this electric equipment must not be disposed with the
domestic waste.
The company WilTec Technik GmbH has been registered in the German registry EAR under the WEEE-
registration number DE45283704.
Disposal of used electrical and electronic appliances
(intended for use in the countries of the European Un-
ion and other European countries with a separate col-
lection system for these appliances).
The logo on the article or on its packaging points out
that this article must not be treated as normal house-
hold waste but must be disposed to a recycling collec-
tion point for electronic and electrical waste equipment.
By contributing to the correct disposal of this article you
protect the environment and the health of your fellow
men. Environment and health are threatened by inap-
propriate disposal.
Material recycling helps reduce the consumption of raw materials.
Additional information on recycling this article can be provided by your local community, municipal waste
disposal facilities, or the store where you purchased the article.
Address:
WilTec Wildanger Technik GmbH
Königsbenden 12 / 28
D-52249 Eschweiler
Important notice:
The reprint or reproduction, even of excerpts, and any commercial use, even in part, of this instruction
manual require the written permission of WilTec Wildanger Technik GmbH.
This manual suits for next models
1
Table of contents
Other TeichTip Pond Pump manuals

TeichTip
TeichTip SUNSUN CQB-2003 User manual

TeichTip
TeichTip Sunsun CT-402 User manual

TeichTip
TeichTip SunSun CHJ3003 User manual

TeichTip
TeichTip Sunsun Bio Pond Filter Set User manual

TeichTip
TeichTip SUNSUN Adjustable SuperECO CET-8000 User manual

TeichTip
TeichTip CTF-2800 User manual

TeichTip
TeichTip Sunsun CQP-8000 User manual
Popular Pond Pump manuals by other brands

AquaScape
AquaScape DOSING SYSTEM SL Instructions & maintenance

Meßner
Meßner eco-N 3400 operating instructions

EasyPro
EasyPro EX8800 Installation and service manual

Messner
Messner MultiSystem M 20000 operating instructions

Oase
Oase AquaOxy 450 operating instructions

Einhell Royal
Einhell Royal TP 4300 operating instructions