I. Guidance notes on safety precauons
1. In order to protect the skin, people below shall not be allowed to use this product:
- People with skin percepon impairment.
- People with allergic dermas, eczema, and other skin diseases.
- People who are allergic to light, make-up, clothing, metal, etc
- Woman who is in the period of pregnancy, menstruaon and lactaon
- People who have been exposed to sunlight in the past two weeks
2. The following parts shall not be available
- Tanned skin
- A dark brown or black skin, such as a mole (refer to a skin contrast card).
- Hemangioma
- Aer cosmec procedures
II. Product Descripon
1. Appearance and structure

1. Power buon, 2. Display area, 3. Flash buon, 4. Power socket
2. Technical parameters of the product:
Light source: Pulsed light
Energy: 1.5 - 4.3 J/cm2
Focus size: 30mm" 10mm
Wavelength: 470nm-1200nm
Luminous life of light: 999900 Times
Adapter specicaon: AC100-240V DC12V 3A
Weight: 170 g
Size: 152*76*45mm
Working temperatura: 5°C-30°C range
Working humidity: Relave humidity range 30%--60%
3. Introducon of product funcon
- Skin Rejuvenaon
- Depilaon
Scope of applicaon: Lip hair, armpit hair, limb hair, forehead hair line and other hair that aect
beauty; Painless hair removal for people with black hair and dark hair, but not for white, o-
white and golden hair; Please refer to the following skin color comparison card for details.
Skin Color
1 2 3 4 5 6
1. White, 2. Yellow, 3. Ligth Brown, 4. Medium Brown, 5. Brown, 6. Dark Brown.

Hair Color
1. White/gray, 2. Gules, 3. Light gold, 4. Dark gold/Light brown, 5. Brown, 6. Dark Brown,
7. Black
The use of this equipment is recommended only for skin tones from white to brown (not dark
brown included) and hair from light gold to black, we insist on remembering that as the skin tone
is darker, it becomes more sensive, which is why we recommend consulng a specialist before
starng any treatment.
III. Procedures for the use of product
1. Dip in medical alcohol with a coon swab or dust-free cloth and clean the light outlet and glass
slice;
2. Long press the "power buon" for 3 seconds to enter the working state; Aer the light outlet
is close to the skin, the digital area on the screen can only ash. If the digital area does not ash,
the skin is not sensed. (As shown in Figure 1-1, the doed line means ashing) Aer switched
ON, the ashing fan icon means the product is storing energy and the fan icon that is always on
means the energy store is completed.(As shown in Figure 1-2, the doed line is ashing)
3. Short-press the "power buon" to select the right gear. The rst gear is the smallest and the
h gear is the largest. First Gear (As shown in Figure 2-1) Second Gear(As shown in Figure 2-2),
Third Gear (As shown in Figure 2-3), Fourth Gear (As shown in Figure 2-4) Fih Gear (As shown
in Figure 2-5) The red area in the picture is always on

4. Short press the ash buon to make the instrument ash; Long press the ash buon to enter
Auto Flash Mode
(Custom Mode). (Figure 3-1, the doed line means ashing)
5. Skin Rejuvenaon: when the power level is set at 1st gear, it will eect the rejuvenaon
funcon. It is suggested to use aer the hair stop growing. Please do not do the rejuvenaon
and hair removal at the same me. Notes: a During operaon, the depilatory areas shall not be
repevely operated or missing. The operaon for the enre depilatory areas shall be completed
before a repeated operaon, with a total of 2-3 mes.
* When the light outlet is ghtly close to the skin, if the digital area of the screen is on without
ashing for a long me, it indicates that the instrument is working abnormally, and you can solve
the problem by following steps below:
A. Check whether the light outlet is close to other objects or not;
B. Aer performing step a, if the digital area is sll on for a long me, keep the light outlet away
from the skin aer keeping ghtly close to the skin for 3-5 seconds, and then check whether the
instrument returns to normal;
C. If step a and step b do not work, restart the instrument.
D. If the above steps can not solve this problem, please consult aer-sale personnel;
6. When the instrument is kept sll for 5 minutes and 30 seconds, the instrument will be in a
standby state. When you use it, you can press the power switch buon to wake it up. The default
is Gear 1.
7. Aer the operaon is completed, press the "power buon" for 3 seconds. The mer starts
counng down to the shutdown and switches itself o 10 seconds later.

8. Dip in the medical alcohol with a coon swab or a clean cloth and clean the stain on the glass
slice.
Note: Aer ashing for mulple mes, there will be white spots inside the lens, which is normal
and does not aect the normal use and life of the instrument.
IV. Hair management process
1. Skin tests before use.
Please apply it in a small part of skin 2 hours before operang the instrument to see if there are
any adverse reacons. Test method When using this product for the rst me, select a small part
on the inside of the arm test separately from the low to high energy gears within the aordable
range (1 to 2 ashes in the same place); If 2 hours aer the ash, there are symptoms such as
swelling, burn marks, change in the hair follicle of the skin or a ngling, please don't use this
product unl you consult a doctor. If no abnormalies are found on the skin within 2 hours and
there is a strong feeling of heang when using, the lower level of energy gear will be the highest
energy gear for you.
2. Use steps
1) Clean the light outlet, shave the hair on the body and clean the residual hairdo not hurt your
skin when shaving;
2) Hair removal;
3) Aer hair removal, cool skin with ice water or a frozen towel to lower the skin temperature;
4) Skin moisturizaon, moisturize the skin with make-up water.
5) Recommended gear ranges and number of operaon in dierent parts for dierent types of
skin. It is available to ash twice in the same part of the limbs and lighter skin, A connuous
ashing operaon is not recommended for limbs and darker skin.
6) When the energy used is high, the mes of operaon should be reduced appropriately;
7) Aer the operaon, if the skin is slightly red with a uniform sense of warmth, stop the
operaon in this pad of skin. Comparison table for gear ranges and number of operaon
Skin color
1 2 3 4 5 6
1. White, 2. Yellow, 3. Ligth Brown, 4. Medium Brown, 5. Brown, 6. Dark Brown.
Posion
Under arm
Color skins White and Yellow: Gear: 3-5 / Times: 3-4
Color skin Light brown: Gear: 3-4 / Times: 3-4

Color skin Medium brown and brown: Gear: 2-3 / Times: 2-3
Color skin Dark brown: Not aplicable
Arms
Color skins White: Gear: 3-5 / Times: 3-4
Color skins Yellow and Light brown: Gear: 2-4 / Times: 2-3
Color skin Medium brown and brown: Gear: 1-3 / Times: 2-3
Color skin Dark brown: Not aplicable
Legs
Color skins White: Gear: 3-5 / Times: 3-4
Color skins Yellow and Light brown: Gear: 2-4 / Times: 2-3
Color skin Medium brown and brown: Gear: 1-3 / Times: 2-3
Color skin Dark brown: Not aplicable
Perioral and face
Color skins White: Gear: 3-4 / Times: 3-4
Color skins Yellow and Light brown: Gear: 2-3 / Times: 2-3
Color skin Medium brown and brown: Gear: 1-2 / Times: 2-3
Color skin Dark brown: Not aplicable
Notes:
- 4 weeks is a depilatory cycle; start to see the eect aer 2 depilatory cycle
- Twice every week for the rst 8 weeks; it is not allowed to be used connuously on the same
day
- It is recommended to use mulple mes to achieve the best hair removal eect according to
the hair dense condion.
- The interval between the specic operaon varies for dierent people, so aer the hair grows
about 30%, you can apply once.
- When the ne hair grows again later aer stop using, the same operaon can be done again
according to the above steps.
V. Notes of instrument operaon
1. When operang, the eye should not look directly at the ash of the light outlet, and ashing
directly at eyes is not allowed.
2. Aer operaon, mild redness of the skin is normal and ice can be applied by yourself;
3. When cleaning any stains on the glass slice inside the light outlet, no alcohol is allowed to
spray directly on the light outlet.

4. When the instrument is in operaon, do not apply any gel cosmecs such as gel water on the
skin to avoid damage to the instrument;
5. Try not to eat sensive foods (e. g. spinach, rapeseed, mustard, etc.) during the operaon;
6. Adjust the energy gear from weak to strong. Without damaging the skin, the higher the energy,
the beer the eect;
7. People with darker skin may have delayed skin reacons, but increasing energy is not allowed
because immediate response is not apparent;
8. Pay aenon to moisturizing and sunscreen aer ashing;
9. Avoid ultraviolet radiaon during use and go out with protecon against the sun. Try to avoid
computer radiaon, and apply an-sun cream and sunscreen;
10. Do not block the air intake and heat dissipaon holes during use to avoid the inuence of
heat dissipaon;
11. During use of the instrument, if hairs or stains sck to plasc part on the edge of the light
outlet, it will cause blackening or black spots on the edge of the light outlet without aecng the
performance and integrity of the normal use of instrument;
12. For "Light tube" inside the light outlet of the instrument, in the later period, the inner wall
of the lamp will be blackened to some extent, which is the normal aging process of the lamp.
During the lifeme of the lamp, the rate of decay of energy will not exceed the prescribed range,
so it can be normally used.
13. The product is not waterproof. Please don't use it when taking a shower in the bathroom or
other places where water may be easily touched;
14. If the case, window or apparatus of the product is broken or coincidentally damage with
water, please send back to the manufacturer for overhaul and see if it can be repaired; If the
device is damaged with water when it is connected with power, please unplug the power adaptor
and then touch the device to ensure your safety;
15. Avoid places where there is a strong magnec eld and serious humidity and dust, or storage
at high temperature;
16. Do not strongly impact or knock on the instrument;
17. The use of purposes other than the designated funcon of this product is not allowed;
18. Except the authorized person by the company, no one shall be allowed to open the casing,
or you will be in danger of electric shock. And it is prohibited for non-professional personnel to
repair it.
This instrucon is for reference only. If you have any queson, please contact our customer
service!