Technical Parameters
Lamp tube: Xenon quartz tube
Light source: Intense pulsed light
Energy Frequency: 15 - 3.9 lian.
Focus size: 4.2cm2.
Wavelength: 470nm-1100nm
Lamp tube life: 600000 mes
Adaptor: AC100-240V @ 12V DC 3A
Operang temperature range: 5-30°C
Operang humidity range: Rotave humidity 30%-60%
1. Flash window, 2. Cooling air inlet, 3. Power/Intensity buon, 4. Cooling air outlet,
5. Intensity/Ready Light, 6. Flash buon

FUNCTION INTRODUCTION
The IVY is intended for hair removal and skin rejuvenaon. This product can be used for excessive
hair on mulple body parts (ex. lip, arpit, limbs, forehead, etc.). The device works most eecvely
on users with black or dark hair. It is not suitable for white, grey, or blonde hair. Please refer to
the color contrast card below for reference.
Skin and Hair color contrast card
SKIN COLOR
1. White, 2. Yellow, 3. Medium Brown, 4. Light Brown, 5. Brown, 6. Dark Brown.
HAIR COLOR
A. White/grey, B. Red, C. Light gold, D. Light brown, E. Brown, F. Dark Brown, G. Black.
INSTRUCTIONS FOR USE
1) Use a medical alcohol wipe to clean the glass window prior to use.
2) Plug the device into a working outlet. The white indicator light should be ickering.
3) Press and hold the < <Power Buon>> for 3 seconds to enter the device into the working state.
The display will turn on while the system is running.
Note: The white indicator light will be on during the start-up process.
• The white indicator light will icker when in proximity to skin due to the built-in sensor in the
ash window.
• If the white light indicator is not ickering. bring the device closer to the skin unl it ickers.
4) Click the <<Power Buon» to select the desired intensity level. The IVY has 5 intensity levels
(1 - minimum, 5 - maximum) as shown in the diagram below. To adjust the intensity level, press
the «Power Buon>> unl the desired intensity level is readied.

5) Move the ash window to the target area unl the power indicator light is ickering. Press the
«Pulse Light Launch Buon» to ash one me. Aer every ash, the red indicator light will be
turned o to charge the power. Aer 1-3 seconds, the light will return to indicate that it is ready
for connued use.
Note:
• For ideal results, it is recommended to ash in the some target area 2-3 mes and consistently
across all intended areas.
• The IVY is not working correctly if the white indicator light is not ickering. If this situaon
occurs, please follow the steps below:
A. Ensure the ash window is close enough to the skin.
B. If the white indicator light is not ickering, move the device to your skin for a duraon of 3-5
seconds and monitor the light to check for normal funcon.
C. If Step 2 is ineecve, restart the device and aempt the funcon again.
D. If the above steps do not solve the issue, please contact our customer support.
6) Press and hold the <<Power Buon» for 3 seconds to shut the IVY down.
7) When nished using the IVY, clean the ash window using a medical alcohol wipe. Note: Aer
frequent use of the device, white spots will appear on the inside of the lens. This will not aect
the performance of the IVY.
HAIR MANAGEMENT PROCESS
TEST BEFORE USE
1) It is strongly advised to check for adverse reacons by conducng a skin test at least 2 hours
in advance of any hair removal procedures.
Test Method:
• On a small area of skin (ex. inside of the upper arm), apply ashes 1-2 mes from low intensity
to high intensity.
• If redness, burns, stabbing pain, or other symptoms occur aer 2 hours, consult a doctor before
using again.

• If slight discomfort appears, lower the intensity level before using again. If discomfort
connues, consult a doctor before further use.
• If slight discomfort appears, lower the intensity level before using again. If discomfort
connues, consult a doctor before further use.
OPERATING STEPS
1) Clean the ash window using medical alcohol wipes and shave the target area. Clean o any
residual hair.
2) Start the device and choose the intensity level best suited for hair removal.
3) Aer using the device, it is recommended to cool the skin using ice water, a damp towel, or a
cooling balm. A toner may also be used to retain skin moisture.
4) It is strongly advised to not use the device mulple mes on the same target area. Flashing
should be done less than two mes in succession in one locaon. The operaon frequency mes
should be reduced when using the device on a high intensity level.
Note:
• Use 6-10 mes during a removal cycle.
• Use once every 2 weeks during the removal cycle.
• if new thin hair grows aer use, operate once every 2-3 months and connue for further
results.
• It is recommended to trim thick areas of hair prior to use.
• Connue to use the device less frequently when hair growth diminishes considerably.
5) To obtain a reference for sessions, intensity level for skin color and specic body parts, please
refer to the following scheme
Posion
Under the arm
Light skin colors: Intensity: 3-5 / Sessions: 3-4
Light brown skin color: Intensity: 3-4 / Sessions: 2-3
Skin color Medium brown and brown: Intensity: 2-3 / Sessions: 2-3
Brown: Intensity: 2-3 / Sessions: 2-3
Skin color Dark brown: Not applicable
Arms
Skin color White: Intensity: 3-5 / Sessions: 3-4

Yellow and light brown skin color: Intensity: 2-4 / Sessions: 2-3
Medium Brown and Brown skin color: Intensity: 1-3 / Sessions: 3-4
Brown: Intensity: 1-3 / Sessions: 2-3
Dark brown skin color: Not applicable
Legs
White skin color: Intensity: 3-5 / Sessions: 3-4
Skin color Yellow: Intensity: 2-4 / Sessions: 3-4
Light Brown skin color: Intensity: 2-4 / Sessions: 2-3
Medium brown and Brown: Intensity: 1-3 / Sessions: 2-3
Dark Brown skin color: Not applicable
Facial
White skin color: Intensity:3-4 / Sessions: 3-4
Yellow and light brown skin color: Intensity: 2-3 / Sessions: 2-3
Medium Brown and Brown skin color: Intensity: 1-2 / Sessions: 2-3
Brown: Intensity: 1-2 / Sessions: 2-3
Dark Brown skin color: Not aplicable
DEVICE OPERATION NOTES
1) Do not ash near or directly at the eyes during use.
2) Do not clean the ash window directly with spray alcohol.
3) Do not apply cosmecs such as water gel to the skin prior to use.
4) Avoid light sensive food (ex. spinach) during operaon.
5) For best results, use the higher intensity levels. (WARNING: DO NOT ATTEMPT UNTIL AFTER
FOLLOWING THE PREVIOUS INSTRUCTIONS)
6) Darker skin colors may not provide immediate skin reacons. Follow the 2 hour waing period
listed previously before increasing the intensity level.
7) Skin moisturizers and sun block can be used as directed aer using the device.
8) Avoid UV rays during use and protect your skin while in the sun.
9) Do not block the Air Inlet and the Cooling Outlet as this can aect the device's cooling process.

10) Hair stuck to the device may result in blank spots; however, this does not aect the IVY's
performance.
11) Connued use of the device may result in dark discoloraon of the light bulb. This will not
disrupt the device's performance unless the light bulb is unable to operate.
12) This product is not waterproof and must be kept away from water.
13) Immediately disconnue use if the plug cord is frayed.
14) Do not store the device near areas with strong magnec elds, moisture, dust, or high
temperatures.
15) Keep out of reach of children.