tekkiwear A110 User manual

IPL HAIR REMOVAL SYSTEM – A110
User Manual
Thank you for choosing our IPL system, for the most eecve use of the product, please read
the user manual carefully before using.
1. Safety Tips
• To protect the skin, it's not suitable for the following customers :
• You have a known skin disorder.
• You have a skin disease such as allergic dermas, eczema, etc.
• Who have photosensizaon.
• If you are experiencing Menstruaon, Pregnant or Lactaon
• If you have sunburn
• Black or sunburn skin (Please refer to the following specic color contrast card)
• Black or fuscescent nevus.
• Broken skin, a scab or healed wound, cancer or hemangioma.
• Your eyes and any arcial aesthec, prosthec or plasc area.
2.Product Introducon
2.1 Packing list:
IPL machine, Power adapter, Warranty card, Instrucon manual.

2.2 Structure Descripon
1. Flash window, 2. Cooling air inlet, 3. Power/intensity buon, 4. Cooling air outlet,
5. Pulse light launch buon, 6. Led display, 7. Cartridge
3. Technical Parameters
Lamp tube: Xenon quartz tube
Light source: Intense pulsed light
Energy Frequency: 15 - 3.9 lian.
Focus size: 4.2cm2.
Wavelength: 470nm-1100nm
Lamp tube life: 600000 mes
Adaptor: AC100-240V @ 12V DC 3A
Operang temperature range: 5-30°C
Operang humidity range: Rotave humidity 30%-60%
4. Funcons Introducon
• Skin rejuvenaon
• Hair removal
This product can be used for: excess hair such as lip hair , armpit hair , limb body hair, forehead
hair etc.; Painless hair removal is suitable for black hair and dark-hair people, it is not suitable
for white, gray or blonde (Refer to the following color contrast card)
Skin and Hair color contrast card

SKIN COLOR
1. White, 2. Yellow, 3. Medium Brown, 4. Light Brown, 5. Brown, 6. Dark Brown.
HAIR COLOR
A. White/grey, B. Red, C. Light gold, D. Light brown, E. Brown, F. Dark Brown, G. Black.
5. Instrucons For Use
5.1 Use a medical alcohol wipe to clean the glass window
5.2 Contact machine with plug , the white indicator ickering
5.3 Press the "power buon" for 3 second, it will start and enter into the working state (The
display is on, and) you can hear the system is running).
Note:
A. You will see the white indicator light is on aer starng up.
B. Then you should move the ash window to your skin, you will see the white indicator light
ickering, because there is a human body inducon sensor built-in the ash window and the
sensor will sense skin when you get close to it .
C. The white light indicator must be ickering, otherwise the device will not work. If you nd
that the white indicator is not ickering, bring it closer to your skin unl it does icker.
5.4 Click the "power buon" to select the suitable intensity level, there are eight The diagram
below shows intensity level from low to high power, level 1 is the minimum power seng, level
8 is maximum power intensity. Any adjustment can be made in the sequence shown with a
click of the power buon.
5.5 Once the intensity level is set, move the ash window to the skin which can cover the ash
window completely, you will see the power indicator light ickering and then click the ash
buon, the would will ash one me; aer every ash operaon the white indicator light will

be turned o to charge the power, aer 1-3 seconds the light will return to indicang that it is
ready for use again.
Note:
• For perfect results, it is suggested the process of hair removal is repeated 2-3 mes and
ensuring all the body parts should not be repeated and omied.
• The device is not working correctly if the white indicator light remains on without ickering,
in this case, please follow the steps below.
A. Ensure the ash window is close enough to the skin.
B. If the white indicator light is sll on ,please move to your skin for 3-5 seconds and check if it
has return to a normal funcon.
C. Please restart it if this operaon failed
D. If the above operaon cannot solve it , please contact our customer service
5.6 The default mode is manual mode, Press the "ash buon" for 3 seconds enter into auto
model("A" appear ). Press the "ash buon" would return to manual mode("A" disappear)
5.7 When nished using, please clean the ash window using the suggested medical alcohol
wet-wipe.
Note: Aer frequent use of the device there will be dew white spot insidethe lens, this will not
aect the normal use and service life of the instrument.
6.Hair Management Process
6.1 In test before use
It is strongly advised to check for adverse reacon by conducng a skin test 2 hours in advance
of any hair removal procedure.
Test method:
On a small area of skin on the inside of the upper arm (the medial). From a low energy to high
energy apply 1-2 mes at the same place. Aer 2 hours if you feel redness, burns, stabbing
painor other symptoms consult a doctor before using again. On slight discomfort, use the
product again on a lower intensity seng, owever if discomfort connues, consult a doctor
before further use.
6.2 Operang steps
6.2.1 Clean the ash window, then shave the hair on your body and clean the residual hair.
6.2.2 Start the device , choose the best suitable intensity level to hair removal.
6.2.3 Aer nish hair removal, you should cool the skin using Ice water or a cold damp towel.
6.2.4 You can use a toner to help your skin retain moisture aer hair removal.

6.2.5 Suggesons about intensity level operaons for all types of skin and dierent parts of the
body, please refer to the below scheme.
6.2.6 It is strongly suggested you do not use mulple mes on the same part of skin. You
should ash less than two mes in succession only at one locaon. The operaon frequency
mes should be reduced when using high energy intensity level.
Skin color, intensity Level and sessions contrast scheme
Armpit
Light skin colors: Intensity: 6-8 / Sessions: 3-4
Light brown skin color: Intensity: 5-7 / Sessions: 2-3
Skin color Medium brown: Intensity: 4-6 / Sessions: 2-3
Brown: Intensity: 1-4 / Sessions: 2-3
Skin color Dark brown: Not applicable
Arms
Light skin colors: Intensity: 6-8 / Sessions: 3-4
Light brown skin color: Intensity: 5-7 / Sessions: 2-3
Medium Brown and Brown skin color: Intensity: 1-4 / Sessions: 2-3
Dark brown skin color: Not applicable
Legs
Light skin colors: Intensity: 6-8 / Sessions: 3-4
Light brown skin color: Intensity: 5-7 / Sessions: 2-3
Medium Brown and Brown skin color: Intensity: 1-4 / Sessions: 2-3
Dark brown skin color: Not applicable
Around mouth and face
Light skin colors: Intensity: 6-8 / Sessions: 3-4
Light brown skin color: Intensity: 4-6 / Sessions: 2-3
Medium Brown skin color: Intensity: 1-4 / Sessions: 2-3
Brown skin color: Intensity: 1-3 / Sessions: 2-3
Dark brown skin color: Not applicable
Note:
• Using for 6-10 mes as a hair removal cycle
• Use one me every two weeks for up to six mes
• Use one me every four weeks when using 6-10 mes

• If you nd new thin hair grow aer use it, operate one me every 2-3 months at this place ,
and connue gaining sasfying results.
• To gain the best results it is suggested that on areas of thick hair you use many mes over a
period of me.
• Use will vary from person to person, use less frequently when hair area grows by a small
amount, about 30%.
7.Device Operaon Notes
7.1 Do not ash near or directly at the eyes when in use.
7.2 Aer operaon, some skin redness is a normal you can cool the area with ice water or cold
damp towel.
7.3 Do not clean the ash window directly with spray alcohol.
7.4 Do not use in conjuncon with other cosmecs such as water gel products.
7.5 Try not to eat light sensive food during operaon (such as spinach, cole, mustard, etc.).
7.6 For best results use the higher energy seng.(Warning -only aer following the previous
instrucons).
7.7 The darker your skin any skin reacon may not be so apparent and the reacon may be
delayed, in this case ensure the 2 hour waing period is followed before increasing the
intensity seng.
7.8 Connue to look aer you skin moisturizing and using Sun block in a normal way aer using
this product.
7.9 Avoid UV light during use and always protecon your skin when out in sun. Also try to
Avoid long exposure to computerradiaon when working, protecng yourself with sun block or
sunscreen.
7.10 No not block the Air inlet and the cooling outlet so as not to aect the cooling of the
device.
7.11 Hair stuck to the device may cause some blank spots but it does not aect the
performance of the device and the normal use.
7.12 In the late period of life, the inner wall of the Light bulb will appear dierent degrees of
black phenomenon, this is a result of the normal aging process of the tubes. Don' t worry to
connue to use as normal within the specied parameters.
7.13 This product is not waterproof, avoid contact with water.
7.14 Any faults, immediately unplug the device, If you nd the factory for maintenance.
7.15 Do not store the device near Strong magnec elds, moisture dustor at high
temperatures.
7.16 Avoid damage and keep out of the reach and sight of children.
7.17 Prohibit using it with other applicaon which is not allowed.

7.18 Prohibit other people opening this device except our authorized persons otherwise it may
be danger electric shock.
Table of contents
Other tekkiwear Hair Removal System manuals