5ADDING TO THE SYSTEM
1) Remove the cover of module
2) Start adding on the mobile or desktop app
Security Hub. Adding starts for 45-60 sec.
3) Install the battery into the module.
If 4 seconds after the adding procedure start the
LED indication shows the “No network”, it
means that the unit has been already added in
another radio network. In this case, it is neces-
sary to reset the unit (see p. 6) and repeat the
registration procedure (steps 2) - 3)).
Before re-installing the battery, wait at least 20
sec.
4) Make sure registration is successful with
Security Hub mobile or web app. If registra-
tion is unsuccessful, repeat the procedure.
6RESET PROCEDURE
1) Remove module’s cover.
2) Close the DEL contacts for 5 sec. - the red
indicator will turn on.
3) After turning off the red indicator, open the
DEL contacts.
4) The module generates a notification “No
network” and becomes available for adding to
the system.
7 INSTALLATION PLACE
The relay unit is not recommended to install:
- on massive metal structures or closer than 1m
from them;
- closer than 1m from power lines and metal
water or gas pipes, sources of radio interfer-
ence;
- inside metal structures.
8INSTALLATION PROCEDURE
1) Remove the module’s cover.
2) Remove PCB.
3) Squeeze out plugs of the selected mounting
holes and the holes for wires entry.
ATTENTION! For safe squeeze of the plugs, fix
the base on a hard surface.
4) Make markup at the selected installation sur-
face using the base as a template.
5) Conduct wires of external power supply (not
required when supplied from battery), ZONE wires
(if necessary) and relay output wires through the
holes for wire entry. Secure the base on the bear-
ing surface. Install the PCB.
6) Connect wires to the terminal block
.
7) Close the unit’s cover.
Note - When the external power supply is connect-
ed, the relay module automatically switches to work
from it, when disconnected, it switches to work from
the battery.
9WARRANTY
Warranty period of operation - 5 years from the
date of commissioning, but not more than 5
years 6 months from the date of manufacture
and subject to the requirements of the current
user guide.