manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. teko
  6. •
  7. Relay
  8. •
  9. teko Astra-8231 User manual

teko Astra-8231 User manual

Other teko Relay manuals

teko ASTRA-BRA User manual

teko

teko ASTRA-BRA User manual

teko Astra-824 User manual

teko

teko Astra-824 User manual

teko ASTRA-BPA User manual

teko

teko ASTRA-BPA User manual

Popular Relay manuals by other brands

Woodward BU1-DC2 manual

Woodward

Woodward BU1-DC2 manual

ABB SSR32 product manual

ABB

ABB SSR32 product manual

Siemens SIRIUS 3UG4633 operating instructions

Siemens

Siemens SIRIUS 3UG4633 operating instructions

Siemens SIRIUS 3TK2824 A.20 Series Original operating instructions

Siemens

Siemens SIRIUS 3TK2824 A.20 Series Original operating instructions

Shelly Pro Series user manual

Shelly

Shelly Pro Series user manual

GE MVAX 11 Technical manual

GE

GE MVAX 11 Technical manual

ABB RELION REF615R manual

ABB

ABB RELION REF615R manual

Kemo Electronic B197 quick guide

Kemo Electronic

Kemo Electronic B197 quick guide

Seg MRM3 manual

Seg

Seg MRM3 manual

Basler BE1-700C manual

Basler

Basler BE1-700C manual

CD Automation REVEX 2PH 280A user manual

CD Automation

CD Automation REVEX 2PH 280A user manual

ABB SPAJ 142 C User manual and technical description

ABB

ABB SPAJ 142 C User manual and technical description

Ruelco 1S04 Operation manual

Ruelco

Ruelco 1S04 Operation manual

Basler V3E Z1P B2C1F instruction manual

Basler

Basler V3E Z1P B2C1F instruction manual

GE DGP instruction manual

GE

GE DGP instruction manual

Kyongbo Electronics GDR-D01 user manual

Kyongbo Electronics

Kyongbo Electronics GDR-D01 user manual

Eaton easyE4 series Application note

Eaton

Eaton easyE4 series Application note

Siemens BD2-AK03X/FS Series installation instructions

Siemens

Siemens BD2-AK03X/FS Series installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Astra-8231
Wireless Relay Unit, 433 MHz
User Guide
Manufacturer:
ZAO NTC TEKO
Gafuri str. 71
420108 Kazan, Russia
+7(843) 528-03-69
[email protected]
www.teko.biz
Made in Russia
Rev. 8231-v1_1_instr_en
1 FUNCTION
The wireless relay unit is intended for:
- control relay output by a command, received
from Security Hub controller.
-controlling external executive devices;
- monitoring of external modules connected with
their “dry contact” outputs to Zone-GND input of the
relay unit. Wire length no more than 3 m.
The relay unit provides measurement and
transmission via radio:
a) the residual capacity of the battery when the
capacity value is 30, 20 and 10%.
b) ambient temperature
2 SPECIFICATIONS
Operating frequency range, MHz .................433
Wieless coverage range, m,.........................100
Supply voltage, V:
- from battery ..............................from 2,2 to 3,0
- from external power supply.........from 10 to 15
Battery average lifetime, years..................... 1,5
Overall dimensions, mm...................101×63×32
Operation conditions
Temperature range, °С............from - 30 to + 55
Relative air humidity, %..........up to 98 at +25°С
without moisture condensation
3 DELIVERY SET
The delivery set includes mounting parts (dow-
els - 2 pcs., screws - 2 pcs.), battery (CR123A,
3V) - 1 pc., user guide - 1 copy.
4 INDICATION
Red LED
Power up
Off
Boot time
1x flash for 1 sec
after power up
Normal power (bat-
tery)
Off
Power failure (battery
discharge)
3-fold flashing with
a period of 25 sec
at a voltage below
2.5 V
Switching to external
power supply 12 V
1x flash for 1sec
Alarm (Zone input)
1x flash for 0,2 sec
Network search
Flashing 5 times per
1 sec
No network
2-fold flashing with
the period of 25 sec
Notes
1 LED notification turns off 60 minutes after the
power is turned on.
2 When notice of "Power failure" appears, it is
necessary to replace the battery within one
week!
5ADDING TO THE SYSTEM
1) Remove the cover of module
2) Start adding on the mobile or desktop app
Security Hub. Adding starts for 45-60 sec.
3) Install the battery into the module.
If 4 seconds after the adding procedure start the
LED indication shows the “No network”, it
means that the unit has been already added in
another radio network. In this case, it is neces-
sary to reset the unit (see p. 6) and repeat the
registration procedure (steps 2) - 3)).
Before re-installing the battery, wait at least 20
sec.
4) Make sure registration is successful with
Security Hub mobile or web app. If registra-
tion is unsuccessful, repeat the procedure.
6RESET PROCEDURE
1) Remove module’s cover.
2) Close the DEL contacts for 5 sec. - the red
indicator will turn on.
3) After turning off the red indicator, open the
DEL contacts.
4) The module generates a notification “No
network” and becomes available for adding to
the system.
7 INSTALLATION PLACE
The relay unit is not recommended to install:
- on massive metal structures or closer than 1m
from them;
- closer than 1m from power lines and metal
water or gas pipes, sources of radio interfer-
ence;
- inside metal structures.
8INSTALLATION PROCEDURE
1) Remove the module’s cover.
2) Remove PCB.
3) Squeeze out plugs of the selected mounting
holes and the holes for wires entry.
ATTENTION! For safe squeeze of the plugs, fix
the base on a hard surface.
4) Make markup at the selected installation sur-
face using the base as a template.
5) Conduct wires of external power supply (not
required when supplied from battery), ZONE wires
(if necessary) and relay output wires through the
holes for wire entry. Secure the base on the bear-
ing surface. Install the PCB.
6) Connect wires to the terminal block
.
7) Close the unit’s cover.
Note - When the external power supply is connect-
ed, the relay module automatically switches to work
from it, when disconnected, it switches to work from
the battery.
9WARRANTY
Warranty period of operation - 5 years from the
date of commissioning, but not more than 5
years 6 months from the date of manufacture
and subject to the requirements of the current
user guide.