manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Tektronix
  6. •
  7. Measuring Instrument
  8. •
  9. Tektronix TPP0850 User manual

Tektronix TPP0850 User manual

Other Tektronix Measuring Instrument manuals

Tektronix DSA8300 User manual

Tektronix

Tektronix DSA8300 User manual

Tektronix PA4000 Series User manual

Tektronix

Tektronix PA4000 Series User manual

Tektronix 7L12 User manual

Tektronix

Tektronix 7L12 User manual

Tektronix KEITHLEY 2600B Series User manual

Tektronix

Tektronix KEITHLEY 2600B Series User manual

Tektronix BPA100 User manual

Tektronix

Tektronix BPA100 User manual

Tektronix GeoProbe G10 User manual

Tektronix

Tektronix GeoProbe G10 User manual

Tektronix TLA7012 User manual

Tektronix

Tektronix TLA7012 User manual

Tektronix SDA601 User manual

Tektronix

Tektronix SDA601 User manual

Tektronix Keithley SourceMeter 2410 User manual

Tektronix

Tektronix Keithley SourceMeter 2410 User manual

Tektronix P6042 PROBE User manual

Tektronix

Tektronix P6042 PROBE User manual

Tektronix 2714 Operating and maintenance manual

Tektronix

Tektronix 2714 Operating and maintenance manual

Tektronix P6248 User manual

Tektronix

Tektronix P6248 User manual

Tektronix P7350 User manual

Tektronix

Tektronix P7350 User manual

Tektronix DC503a User manual

Tektronix

Tektronix DC503a User manual

Tektronix 492, 492P User manual

Tektronix

Tektronix 492, 492P User manual

Tektronix Keithley 7711 User manual

Tektronix

Tektronix Keithley 7711 User manual

Tektronix CSA7404B User manual

Tektronix

Tektronix CSA7404B User manual

Tektronix MTS4000 MPEG Manual

Tektronix

Tektronix MTS4000 MPEG Manual

Tektronix Keithley 2601B-PULSE User manual

Tektronix

Tektronix Keithley 2601B-PULSE User manual

Tektronix CSA8000 Series User manual

Tektronix

Tektronix CSA8000 Series User manual

Tektronix TLA5000 Series Operating and maintenance instructions

Tektronix

Tektronix TLA5000 Series Operating and maintenance instructions

Tektronix 7D20 User manual

Tektronix

Tektronix 7D20 User manual

Tektronix 5D10 User manual

Tektronix

Tektronix 5D10 User manual

Tektronix 067-0599-00 User manual

Tektronix

Tektronix 067-0599-00 User manual

Popular Measuring Instrument manuals by other brands

Powerfix Profi 278296 Operation and safety notes

Powerfix Profi

Powerfix Profi 278296 Operation and safety notes

Test Equipment Depot GVT-427B user manual

Test Equipment Depot

Test Equipment Depot GVT-427B user manual

Fieldpiece ACH Operator's manual

Fieldpiece

Fieldpiece ACH Operator's manual

FLYSURFER VIRON3 user manual

FLYSURFER

FLYSURFER VIRON3 user manual

GMW TG uni 1 operating manual

GMW

GMW TG uni 1 operating manual

Downeaster Wind & Weather Medallion Series instruction manual

Downeaster

Downeaster Wind & Weather Medallion Series instruction manual

Hanna Instruments HI96725C instruction manual

Hanna Instruments

Hanna Instruments HI96725C instruction manual

Nokeval KMR260 quick guide

Nokeval

Nokeval KMR260 quick guide

HOKUYO AUTOMATIC UBG-05LN instruction manual

HOKUYO AUTOMATIC

HOKUYO AUTOMATIC UBG-05LN instruction manual

Fluke 96000 Series Operator's manual

Fluke

Fluke 96000 Series Operator's manual

Test Products International SP565 user manual

Test Products International

Test Products International SP565 user manual

General Sleep Zmachine Insight+ DT-200 Service manual

General Sleep

General Sleep Zmachine Insight+ DT-200 Service manual

Sensa Core Lacto Spark user manual

Sensa Core

Sensa Core Lacto Spark user manual

VOLTCRAFT UTS-1980 operating instructions

VOLTCRAFT

VOLTCRAFT UTS-1980 operating instructions

EBCHQ 94915 Operation manual

EBCHQ

EBCHQ 94915 Operation manual

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Balluff

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Pulsar IMP Lite Series instruction manual

Pulsar

Pulsar IMP Lite Series instruction manual

ETCR 6800 user manual

ETCR

ETCR 6800 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

xx Operating Information
The TPP0850 Probe is a high impedance probe
with 50X attenuation that is designed for use with
Tektronix DPO/MSO4000B & DPO/MSO5000 series
ground-referenced oscilloscopes.
Connect the probe as shown in the illustrations below.
Compensating the Probe (Required for Initial Use)
You must compensate the probe after you attach it to an
oscilloscope for the first time, or after you move it to another
channel on the same oscilloscope.
1. Connect the probe to an oscilloscope channel.
2. On MSO/DPO5000 instruments:
a. Connect the probe to the probe compensation output
terminals on the oscilloscope front panel.
b. Select Vertical > Probe Cal....
c. Select the channel number tab of the channel that you
connected the probe to.
d. In the Calibration section, click Calibrate Probe.
On MSO/DPO4000B instruments:
a. Press the Channel Menu front panel button for the
channel that you connected the probe to.
b. Push the More button until Probe Setup is selected.
c. Push the Calibrate Probe button and follow the
on-screen instructions.
If the probe compensation fails, verify that the signal
and ground connections are secure at the Probe Comp
connections on the oscilloscope, and secure at the probe
head and tip.
Standard Accessories
WARNING. To avoid electric shock when using the probe
or accessories, keep your fingers behind the finger
guard of the probe body and away from the shaded area
shown in the accessory illustrations below.
Item Description
Small hook tip (TASH)
Use this tip to access test
points in tight spaces.
Screw the hook tip onto the
probe tip and then clamp the
hook onto the circuit.
Rating: 2300 V CAT I
1000 V CAT II
Reorder Tektronix part number
013-0386-xx
Large hook tip (TALH)
Use this tip to connect to large
components and terminals.
Screw the hook tip onto the
probe tip and then clamp the
hook onto the circuit.
Rating: 2300 V CAT I
1000 V CAT II
Reorder Tektronix part number
013-0384-xx
Ground lead (TAGL)
Slidethegroundleadoverthe
probe head and snap it into
place.
Connect the banana plug end
directly to your circuit ground,
or use the crocodile clip below.
Reorder Tektronix part
numbers:
6 inch: 196-3524-xx
18 inch: 196-3525-xx
Item Description
Crocodile clip
Attach the clip to the banana
end of the ground lead and
then to your circuit ground.
Reorder Tektronix part number
344-0461-xx
Color bands
Use these bands to identify
the oscilloscope channel at the
probe head.
Reorder Tektronix part number
016-1886-xx (5 pairs)
Ground spring
To limit aberrations on high
frequency signals caused by
ground path inductance, bend
the spring to reach nearby
ground connections (~1 in).
Reorder Tektronix part number
214-5298-xx
Optional Accessories
The accessories shown below are available for the probes
and are rated ≤30 V unless indicated otherwise.
Accessory
Part
number
BNC to Tip Adapter,
Unterminated
013-0291-xx
Rubber Spring Tip 206-0060-xx
TPP0850
800 MHz 50X High Voltage Probe
Instructions
x
*P071288400*
071-2884-00
Specifications
Table 1: Electrical and mechanical specifications
Bandwidth (–3 dB) 800 MHz
System rise time (typical) <525 ps
System input capacitance
(typical)
1.8 pF
System attenuation accuracy 50:1 ±2.2%
System input resistance @DC 40 MΩ±1%
Propagation delay ~6.1 ns
Cable length 1.3 m
Maximum input voltage
(see Performance Graphs)
1000 VRMS CAT II (2500 Vpk)
Performance Graphs
Table 2: Environmental specifications
Characteristics Description
Temperature
Operating
Nonoperating
0°Cto+50°C(+32°Fto+122°F)
–40 °C to +71 °C (–40 °F to +160 °F)
Humidity
Operating 5% to 95% relative humidity (RH) up to
+30 °C
5% to 75% RH above +30 °C to +65 °C.
Noncondensing
Nonoperating 5% to 45% RH +65 °C to +85 °C.
Noncondensing
Altitude
Operating
Nonoperating
3.0 km (9,842 ft) maximum
15.4 km (50,000 ft) maximum
Table 3: Certifications and compliances
Characteristics Description
EC
Declaration
of
Conformity
Compliance was demonstrated to the following
specification as listed in the Official Journal of
the European Communities:
Low Voltage Directive 2006/95/EC:
EN61010-031/A1: 2008
Measurement
Category
Product
Examples
CAT III: Distribution-level mains, fixed
installation
CAT II: Local-level mains, appliances, portable
equipment
CAT I: Circuits not directly connected to mains.
Characteristics Description
Pollution
Degree 2
Do not operate in environments where cond-
uctive pollutants may be present (as defined in
IEC 61010-1). Rated for indoor use only.
Additional
Safety
Standards
IEC61010-031; IEC 61010-031/A1:2008
Equipment Recycling. This product complies
with the European Union’s requirements
according to Directive 2002/96/EC on waste
electrical and electronic equipment (WEEE).
For more information about recycling options,
check the Support/Service section of the
Tektronix Web site (www.tektronix.com).
Safety Summary
Review the following safety precautions to avoid injury and
prevent damage to this product or any products connected
to it. To avoid potential hazards, use this product only as
specified. Using the probe or accessories in a manner not
specified could result in a shock or fire hazard.
To Avoid Fire or Personal Injury
Ground-Referenced Oscilloscope Use. Do not float the
reference lead of this probe when using with ground
referenced oscilloscopes (for example, DPO, MSO, and
TDS series oscilloscopes). The reference lead must be
connected to earth potential (0 V).
Connect and Disconnect Properly. Connect the probe output
to the measurement instrument before connecting the probe
to the circuit under test. Disconnect the probe input and
the probe reference lead from the circuit under test before
disconnecting the probe from the measurement instrument.
Avoid Electric Shock. To avoid injury or loss of life, do not
connect or disconnect probes or test leads while they are
connected to a voltage source.
Observe All Terminal Ratings. To avoid fire or shock hazard,
observe all ratings and markings on the product. Consult
the product manual for further ratings information before
making connections to the product.
Avoid Electric Shock. When using probe accessories, never
exceed the lowest rating of the probe or its accessory,
whichever is less, including the measurement category and
voltage rating.
Avoid Electric Overload. To avoid injury or fire hazard, do
not apply potential to any input, including the reference
inputs, that varies from ground by more than the maximum
rating for that input.
Avoid Exposed Circuitry and Do not Operate Without
Covers. Do not touch exposed connections and components
when power is present.
Inspect The Probe And Accessories. Before each use,
inspect probe and accessories for damage (cuts, tears,
defects in the probe body, accessories, cable jacket, etc.).
Do not use if damaged.
Do Not Operate in Wet/Damp Conditions.
Do Not Operate in an Explosive Atmosphere.
Keep Product Surfaces Clean and Dry.
Safety Terms and Symbols Terms in This Manual.
These terms may appear in this manual:
WARNING. Warning statements identify conditions or
practices that could result in injury or loss of life.
CAUTION. Caution statements identify conditions or
practices that could result in damage to this product or
other property.
Symbols on the Product. These symbols may appear on
the product:
Contacting Tektronix
Web site: www.tektronix.com
Phone: 1-800-833-9200
Address: Tektronix, Inc.
Department or name (if known)
14200 SW Karl Braun Drive
P.O. Box 500
Beaverton, OR 97077 USA
Email: [email protected]
Warranty Information
For warranty information, go to
www.tektronix.com/warranty.
Copyright © Tektronix, Inc. All rights reserved. www.tektronix.com