Telco Systems Metrobility T3 2115-23-01 Operation manual

Installation & User Guide
Models: 2115-23-01 / 2115-24-01 / 2115-25-01 / 2115-26-01 /
2115-27-01 / 2115-2J-01 / 2115-2X-01 / 2115-2Y-01 /
2175-23-01 / 2175-24-01 / 2175-25-01 / 2175-26-01 /
2175-27-01 / 2175-2J-01 / 2175-2X-01 / 2175-2Y-01
Metrobility®
T3/E3 “twister”®
SM
PWR
T3-FX T3-TX
®
“twister” 2115
SM
E3-FX E3-TX
®
“twister” 2175
MM
PWR
T3-FX T3-TX
®
“twister” 2115
LBK LK LBK LK
MM
E3-FX E3-TX
®
“twister” 2175
PWR
PWR
RXTX RX
TX
RX
TX
RXTX
TX
RX
TX
RX
LBK LK LBK LK
LBK LK LBK LK
LBK LK LBK LK
TXRX
TXRX
T3-BWDM T3-TX
®
“twister” 2115
PWR
LBK LK LBK LK
TXRX E3-BWDM E3-TX
®
“twister” 2175
PWR
LBK LK LBK LK
TXRX

This publication is protected by the copyright laws of the United States and other countries, with all rights re-
served. No part of this publication may be reproduced, stored in a retrieval system, translated, transcribed, or
transmitted, in any form, or by any means manual, electric, electronic, electromagnetic, mechanical, chemical,
optical or otherwise, without prior explicit written permission of Telco Systems, Inc.
© 2006 Telco Systems, Inc. All rights reserved. Printed in USA.
Metrobility® T3/E3 Models
T3 Copper to T3 Fiber:
2115-23-01 ______ T3 BNC to T3 multimode SC
2115-24-01 ______ T3 BNC to T3 singlemode SC
2115-25-01 ______ T3 BNC to T3 multimode ST
2115-26-01 ______ T3 BNC to T3 singlemode ST
2115-27-01 ______ T3 BNC to T3 singlemode SC (40km)
2115-2J-01 ______ T3 BNC to T3 singlemode SC (100km)
2115-2X-01 ______ T3 BNC to T3 singlemode SC 1550/1310nm bidirectional wavelength
division multiplexed (BWDM)
2115-2Y-01 ______ T3 BNC to T3 singlemode SC 1310/1550nm BWDM
E3 Copper to E3 Fiber:
2175-23-01 ______ E3 BNC to E3 multimode SC
2175-24-01 ______ E3 BNC to E3 singlemode SC
2175-25-01 ______ E3 BNC to E3 multimode ST
2175-26-01 ______ E3 BNC to E3 singlemode ST
2175-27-01 ______ E3 BNC to E3 singlemode SC (40km)
2175-2J-01 ______E3 BNC to E3 singlemode SC (100km)
2175-2X-01 ______ E3 BNC to E3 singlemode SC 1550/1310nm BWDM
2175-2Y-01 ______ E3 BNC to E3 singlemode SC 1310/1550nm BWDM

Table of Contents
Metrobility T3/E3 “twister” Installation & User Guide
Overview ..................................................................................................................... 4
Installation Guide ..................................................................................................... 5
STEP 1: Unpack the Media Converter and Accessories................................ 5
STEP 2: Choose an Appropriate Location .................................................... 5
STEP 3: Set the Switches ............................................................................. 6
STEP 4: Connect to the Network .................................................................. 7
STEP 5: Apply Power.................................................................................... 8
User Guide ................................................................................................................ 11
LED Indicators ............................................................................................ 11
Theory of Operation .................................................................................... 12
Link Loss Indications .................................................................................. 14
Loopback Modes ......................................................................................... 16
Topology Solutions...................................................................................... 18
Technical Specications .............................................................................. 19
Acronyms and Abbreviations ...................................................................... 21
Product Safety, EMC and Compliance Statements ..................................... 22
Warranty and Servicing ............................................................................... 23
Metrobility, Metrobility Optical Systems, and “twister” are registered tradmarks and the Metrobility Optical
Systems logo is a trademark of Telco Systems, a BATM company. All others are trademarks of their respective
owners.
The information contained in this document is assumed to be correct and current. The manufacturer is not
responsible for errors or omissions and reserves the right to change specications at any time without notice.

4 Overview Metrobility T3/E3 5
Overview
Thank you for choosing the Metrobility T3/E3 media converter.
The Metrobility T3/E3 media converter from Systems provides high-speed inte-
gration and conversion of T3 (44.736Mpbs) or E3 (34.368Mbps) coaxial telco com-
munication lines to ber transport environments. The copper data stream is converted
to optical signals for greater noise immunity and longer transmission. The T3/E3
model supports remote ber optic links up to 2km over multimode and up to 100km
over singlemode cable.
To optimize your T3/E3 network, this plug-and-play media converter operates
seamlessly with low jitter. All signal activity is completely converted ensuring
accurate communication within connected segments. The Metrobility T3 model
features a user-selectable line build out, and all T3 and E3 models include
independent copper and ber loopback modes to isolate problems within a specic
segment of the network.
The Metrobility T3/E3 media converter offers the following key features:
• B3ZS (T3) or HDB3 (E3) line code support on the coaxial interface.
• System and port LEDs on the front panel for easy visual diagnostics.
• Independent copper and ber loopback modes.
• User-selectable line build out for short or long haul operation on the T3
models.
• Coaxial to multimode conversion up to 2km, coaxial to singlemode conver-
sion up to 100km, or coaxial to bidirectional wavelength division multi-
plexed (BWDM) conversion up to 20km.
• Surge protection on the RX and TX ports of the coaxial interface.
• Low jitter for maximum transmission quality.
• Independent clocking on the RX and TX ports.
• High MTBF.

4 Overview Metrobility T3/E3 5
Installation Guide
1
2
Follow the simple steps outlined in this section to install and start using your
Metrobility T3/E3 media converter.
Unpack the Media Converter and Accessories
Check that the following components have been included with your order:
• Metrobility T3/E3 media converter
• Power supply
• Power supply cord
• Four (4) rubber feet
Your order has been provided with the safest possible packaging, but ship-
ping damage does occasionally occur. Inspect your order carefully. If you
discover any shipping damage, notify your carrier and follow their instruc-
tions for damage and claims. Save the original shipping carton if return or
storage of the unit is necessary.
Choose an Appropriate Location
The Metrobility T3/E3 media converter is intended for use in either ofce or
industrial environments. The unit must be located within six (6) feet of the
AC power source being used and placed as far away as possible from elec-
trical noise generating equipment such as copiers, electrostatic printers and
other motorized equipment. If exposed twisted-pair wiring is used nearby,
the wiring should be routed as far away as possible from power cords and
data cables to minimize interference.
The unit may be oriented in any manner which permits the user to make
physical connection to the power supply and leaves a minimum of six (6)
inches of space for proper ventilation.
TUV Compliance Note: For pluggable equipment, the socket outlet must be
installed near the equipment and be easily accessible.
Bei Geräten mit Steckanschluß muß die Steckdose nahe dem Gerät ange-
bracht und leicht zugänglich sein.

6 Installation Guide
Metrobility T3/E3 7
LBO Switch (functional only on T3 models)
Set the Line Build Out (LBO) switch down to support a long haul con-
nection if the length of your coaxial cable is between 255 and 1200 feet.
Set LBO up to support a short haul connection if the length of your coaxial
cable is less than 255 feet. The default setting is short haul.
CLP Switch
The Copper Loopback (CLP) switch enables/disables loopback on the cop-
per port. When copper loopback is enabled, the incoming data and clock
are looped from the RX copper port to the TX copper port, thus returning
the copper input back to the sending device. At the same time, the data is
transmitted to the remote T3/E3 unit. However, data from the remote unit
is ignored. Loopback is disabled by default. For more information, refer to
Loopback Modes in the User Guide section of this manual.
FLP Switch
The Fiber Loopback (FLP) switch enables/disables loopback on the ber
optic port. When ber loopback is enabled, the incoming data and clock are
looped from the RX ber port to the TX ber port. The data is also trans-
mitted to the copper port, however, data from the copper port is ignored.
Loopback is disabled by default. For more information, refer to Loopback
Modes in the User Guide section of this manual.
3
Set the Switches
A set of DIP switches is located on the back of the unit. On the T3 models,
functional switches are clearly labeled and allow you to select from several
modes of operation. On the E3 models, only the switches labeled CLP and
FLP are functional. Unmarked switches are inoperative.
NOTE: The switch is ON when it is in the DOWN position.
The switch is OFF when it is in the UP position.

6 Installation Guide
Metrobility T3/E3 7
Connect to the Network
The Metrobility T3/E3 model offers the ease of plug-and-play installation.
Once power is applied to the unit, correct connectivity can be veried via
the link (LK) LED.
To connect to the network, insert the cables into the appropriate connectors
as illustrated below.
When making network connections, make sure that the receive (RX) port
on the unit connects to the transmit (TX) port of the connected device, and
make sure that the receive port of the connected device connects to the
transmit port of the Metrobility model.
4
SM
E3-FX E3-TX
T3-FX T3-TX
LK
LK
PWR
LBK
“twister”® 2175
“twister”
®
2115
RXTX
LBK
SM
RX
LK PWR
LBK MAN
LK
LK
TX
RX
TX
RX

8 Installation Guide
Metrobility T3/E3 9
Coaxial Interface
The coaxial interface provides two BNC connectors. The receive port is
labeled RX and the transmit port is labeled TX. Each connector supports a
maximum segment length of 1200 feet. Use only RG-59 cables.
Fiber Optic Interface
2115-23-01, 2115-25-01, 2175-23-01 and 2175-25-01: The ber optic
multimode (MM) interface supports a maximum segment length of 2km for
remote links.
2115-24-01, 2115-26-01, 2175-24-01 and 2175-26-01: The singlemode
(SM) connector supports a maximum segment length of 15km.
2115-27-01 and 2175-27-01: The singlemode long haul interface supports a
maximum segment of 40km.
2115-2J-01 and 2175-2J-01: The singlemode extended long haul interface
supports a maximum segment length of 100km.
BWDM Interface
The 2115-2X-01, 2115-2Y-01, 2175-2X-01 and 2175-2Y-01 provide one
bidirectional wavelength division multiplexed (BWDM) SC connector
which supports a maximum segment length of up to 20km for remote links.
BWDM units must always be used in complementary pairs. That is, a-2X
model must be connected to a -2Y. The -2X unit is designed to transmit data
at a wavelength of 1550nm and receive at 1310nm. Correspondingly, the
-2Y unit transmits data at 1310nm and receives at 1550nm.
Metrobility
-2X Model
Metrobility
-2Y Model
up to 20km

8 Installation Guide
Metrobility T3/E3 9
5
Apply Power
Power is provided through the desktop power supply module. This power
module is equipped with an S760 hollow-type plug for insertion into the DC
jack located on the back of the unit and a standard IEC 320-type AC power
receptacle.
When making power connections, it is recommended that the DC power
cord be connected to the DC input jack located on the back of the media
converter before making the AC connection to the outlet.
PWR
DC INPUT/5VDC
ON
OFF
LBO
CLP
FLP
Upon receiving power, the media converter goes into normal operation
mode and automatically provides the appropriate signal translation between
the connected network segments.
Verify correct segment connectivity via the LK LEDs on the front panel.
If an additional extension cord is used to connect the power module to the
power source, the following guidelines must be followed.
While one end of the AC power cord can be tted with whatever plug
is standard for the country of operation, the end that connects to the
power supply module must have a female plug that ts this type of AC
receptacle.

10 Installation Guide
Metrobility T3/E3 11
• AC 115V (North American): use a UL-listed and CSA-certied cord
set consisting of a minimum 18 AWG, type SVT or SJT three-con-
ductor cord, a maximum of 15 feet in length and a parallel blade,
grounding-type attachment plug rated 15A, 125V.
• AC 230V (USA): use a UL-listed cord set consisting of a minimum
No. 18 AWG, type SVT three-conductor cord, a maximum of 15 feet
in length and a Tandem blade grounding-type attachment plug rated
15A, 250V.
• 240V (outside USA): use a cord set consisting of a minimum No. 18
AWG cord and grounding-type attachment plug rated 15A, 250V.
The cord set should have the appropriate safety approvals for the
country in which the unit is being installed and marked HAR.

10 Installation Guide
Metrobility T3/E3 11
User Guide
This section contains more detailed information regarding the operating features
of the Metrobility T3/E3 media converter.
LED Indicators
The Metrobility T3/E3 media converter provides several LEDs on the front panel for
the visible verication of unit status and proper functionality. These LEDs can aid in
troubleshooting and overall network diagnosis and management.
DELmetsyS
DEL
lebaL
/roloC
sutatS noitacidnI
RWP
neerG .rewopgniviecersitinU
FFO .deliafsahrorewopgniviecertonsitinU
sDELtroPreppoC
DEL
lebaL
/roloC
sutatS noitacidnI
KL
neerG .tropeviecerreppocehtnotneserpsilangisA
FFO .tropehttadetcetedsilangisoN
KBL
wolleY
ehtnosemarfgnimocnI.edomkcabpoolnisitropreppoC
siataD.eniltimsnartlaixaocehtnokcabtneseratropreppoc
.eniltimsnartcitporebifehthguorhttnesosla
FFO .noitarepolamron;tropreppocehtnodelbasidsikcabpooL
sDELtroPcitpOrebiF
DEL
lebaL
/roloC
sutatS noitacidnI
KL
neerG .tropeviecercitporebifehtnotneserpsilangislacitponA
FFO .troprebifehttadetcetedsilangisoN
KBL
wolleY
erakcolcdnaatadgnimocnI.edomkcabpoolnisitroprebiF
tuodettimsnartoslasiataD.enilrebiftimsnartehtnokcabtnes
.eniltimsnartlaixaoceht
FFO .noitarepolamron;troprebifehtnodelbasidsikcabpooL

12 Installation Guide
Metrobility T3/E3 13
Theory of Operation
Functional Block Diagram
Line
Transformers
Line
Interface
Unit
FPGA
VCXO
Fiber
Optic
Circuit
RX
Coaxial
TX
TX
Fiber
RX
Coaxial to Fiber Data Path
The receive (RX) port on the coaxial interface accepts an electrical signal. This
signal is coupled to the line interface unit (LIU) through a line transformer. The LIU
performs clock and data recovery and converts the signal into non-return to zero
(NRZ) data and clock. The NRZ data and clock then pass through the eld-program-
mable gate array (FPGA), which encodes the data for ber optic transmission. The
encoding ensures adequate transition density for reliable clock recovery at the remote
T3/E3 ber optic interface.
Fiber to Coaxial Data Path
The RX port on the ber interface accepts an optical signal from the remote T3/E3
unit and converts it back to an electrical signal. The optical signal rst enters the
voltage-controlled crystal oscillator (VCXO), which extracts the line rate clock and
data. The recovered clock and data are then sent to the FPGA for decoding. The de-
coded data stream goes to the LIU for encoding into T3 or E3 signals. The transmit-
ted signal is coupled to the BNC coaxial connector through a line transformer.
On both the RX and TX ports of the coaxial interface, surge protection is provided.
Timing Paths
The transmit (TX) and receive (RX) paths are clocked independently and during nor-
mal operation, the Metrobility T3/E3 units are never timing masters of the network
system. In the coaxial to ber path, timing is recovered by the unitʼs LIU and trans-
mitted over the ber line to the remote T3/E3 unit. In the ber to coaxial path, timing
is derived from the incoming optical signal and sent over the coaxial TX line.

12 Installation Guide
Metrobility T3/E3 13
Local
T3/E3
Unit
Remote
T3/E3
Unit
Coaxial CoaxialFiber
A
F
C
B
E D
The following table describes how timing is affected if a failure occurs at various
points in the network.
eruliaFeniL
tnioP tluseR
AOXCVs'reviecerrebifehT.langisfossolstcetedtinu3E/3TlacolehT
.Bknilrebifrevonoissimsnartrofecruosgnimitehtsemoceb
BehT.tupnikcolcecnereferstiotstreverOXCVs'tinu3E/3TetomerehT
.retsamgnimitmetsysehtsemocebtinu3E/3Tetomer
C
,gnimitdepoolstroppustinu3E/3TetomerehtotdetcennoctnempiuqeehtfI
.langisfossolstcetedtinehwkcolclanretnistiottreverdluohstnempiuqeeht
dna,kcolcrolangisdilavaedivorpotliafdluoctnempiuqeeht,ylevitanretlA
.Dtnioptaderruccoeruliafehtfisaevaheblliwmetsyseht
DOXCVs'reviecerrebifehT.langisfossolstcetedUILs'tinu3E/3TetomerehT
.Eknilrebifrevonoissimsnartrofecruosgnimitehtsemoceb
ElacolehT.tupnikcolcecnereferstiotstreverOXCVs'tinu3E/3TlacolehT
.retsamgnimitmetsysehtsemocebtinu3E/3T
F3E/3TlacolehtotdetcennocecivedehT.srucconoitpursidgnimitmetsysoN
.langisfossolstcetedtinu
Data Transparency
The Metrobility T3/E3 media converter offers full data transparency. Any codes or
commands contained within the data stream are passed through to the remote device.
The only commands executed by the Metrobility converter are those set through the

14 User Guide
Metrobility T3/E3 15
Link Loss Indications
The following examples show the status of the LK LED under various link condi-
tions and describe when unframed all ones are generated. (Loopback is disabled in
these examples.)
Note: An all-ones pattern indicates an alarm indication signal (AIS) for the E3 units
only. For T3 models, the all-ones pattern is simply transmitted to the remote device;
it does NOT indicate AIS.
Normal
The diagram below shows a typical conguration with good link status.
Remote
Device
Local
Device
Local T3/E3
Unit
Remote T3/E3
Unit
green LED unlit LED
Coax CoaxFiber
LK
LK
LK
LK
Input Coaxial Link Loss
Loss of the copper input disables the BNC portʼs LK LED. It also forces the T3/E3
unit to generate unframed all ones (AIS for E3 only), which are transmitted out its -
ber port. For example, if the local unitʼs inbound coaxial cable breaks, it will transmit
all ones to the remote T3/E3 unit via the ber cable. The remote unit then carries the
pattern forward via its coaxial cable to the remote device.
Input Fiber Link Loss
Loss of the ber input is indicated by the ber portʼs unlit LK LED. When the ber
input is lost, an unframed all-ones pattern is transmitted from the coaxial port, as
shown in the following illustration.
Remote
Device
Local
Device
Local T3/E3
Unit
Remote T3/E3
Unit
green LED unlit LED
Coax CoaxFiber
LK
LK
LK
LK
All Ones All Ones
All Ones carried forward

14 User Guide
Metrobility T3/E3 15
Remote Coaxial Link Loss
Loss of link to the remote device produces a red alarm condition at the remote site
and should force the device to revert to its internal clock. If the remote device is
congured to send back a yellow alarm under this condition, the two T3/E3 units will
carry the alarm forward to the local device, as shown below.
Remote
Device
Local
Device
Local T3/E3
Unit
Remote T3/E3
Unit
green LED unlit LED
Coax CoaxFiber
LK
LK
LK
LK
All Ones
Remote
Device
Local
Device
Local T3/E3
Unit
Remote T3/E3
Unit
green LED unlit LED
Coax CoaxFiber
LK
LK
LK
LK
AIS AIS
AIS carried forward
AIS

16 User Guide
Metrobility T3/E3 17
Loopback Modes
The Metrobility T3/E3 media converter features two loopback modes to help verify
correct installation and to diagnose system problems.
Normal
During normal operation, without loopback, data from a local device (CSU, PBX,
etc.) enters the local T3/E3 unitʼs coaxial receiver, passes through the ber line be-
tween the two converters, then exits the remote unitʼs coaxial transmitter to enter the
remote equipment, and vice versa.
Loopback
Loopback helps to isolate and identify trafc problems within a specic segment.
During loopback, the yellow LBK LED is lit. Loopback is enabled/disabled by set-
ting DIP switch 2 or 3. Once loopback is enabled, the unit will remain in this mode
until the DIP switch is turned off.
Copper and ber loopback cannot be enabled at the same time. If both DIP switches
are enabled, only the rst one set will be in effect until it is disabled.
Copper Loopback
During copper loopback, timing and data received on the coaxial line are looped
back to the sending device. The loop occurs in the FPGA. The data is also
transmitted to the remote T3/E3 converter, but the data from the remote unit is
ignored by the converter in loopback mode.
In the example shown below, the local T3/E3 unit has copper loopback enabled.
Data received at the BNC port is simultaneously returned to the local device and
sent to the remote T3/E3 unit and on to the remote device. Data from the remote
device is transmitted by the remote unit, however, it is ignored by the local unit
at its ber optic interface.
Local T3/E3
Unit
Remote T3/E3
Unit
Coax Coax
Fiber
Local
Device
Remote
Device
Local T3/E3 Unit
with Copper Loopback
Remote T3/E3
Unit
Coax Coax
Fiber
Local
Device
Remote
Device
X

16 User Guide
Metrobility T3/E3 17
Fiber Loopback
In this mode, the incoming data and clock on the ber line are looped back. The
loop occurs in the FPGA. The data is still sent out the coaxial transmitter. How-
ever, the data received at the BNC interface is ignored.
In the example below, the remote T3/E3 unit has ber loopback enabled. Data
received at the ber optic input is simultaneously returned to the local device
and sent to the remote device. However, data from the remote device is ignored
by the remote T3/E3 unit at its coaxial interface.
Local T3/E3
Unit
Remote T3/E3 Unit
with Fiber Loopback
Coax Coax
Fiber
Local
Device
Remote
Device
X

18 User Guide
Metrobility T3/E3 19
Topology Solutions
The Metrobility T3/E3 model is a point-to-point media converter designed to extend
the reach of copper T3/E3 links and to provide protection from power surges and
electromagnetic interference. Each model supports a single remote T3/E3 unit.
fiber T3/E3
copper T3/E3
up to 100km
singlemode
Private Branch Exchange (PBX)
PBX
Metrobility T3/E3 Model
Metrobility T3/E3 Model
up to 100km
singlemode
Data Service Unit (DSU)
Channel Service Unit (CSU)
Metrobility T3/E3 Model
Metrobility T3/E3 Model
Metrobility R5000 Chassis
with T3/E3 Modules
up to 2km
multimode
PBX
CSU
Metrobility T3/E3 Model

18 User Guide
Metrobility T3/E3 19
Technical Specications
Network Connections
Coaxial Interface
Connector ______________________________________________ BNC receptacle
Impedance____________________________________________________ 75 ohms
Signal Structure ________________________________ ANSI T1.404, T1404a (T3)
_________________________________________ ITU G.703 (E3)
Supported Link Length _______________________________________up to 1200 ft
Cable Type _________________________________________ RG-59 coaxial cable
Multimode Fiber Optic Interface
Connector ___________________________________________________ ST or SC
Wavelength ___________________________________________________ 1310 nm
RX Input Sensitivity _______________________________ -31 dBm peak minimum
Output Power __________________________ -20 dBm to -14 dBm (62.5/125 µm)
Supported Link Length ________________________________up to 2km full duplex
Cable Type _____________________________________ 50/125, 62.5/125 µm F/O
Singlemode Fiber Optic Interface
Connector ___________________________________________________ ST or SC
Wavelength ___________________________________________________ 1310 nm
RX Input Sensitivity _______________________________ -31 dBm peak minimum
Output Power _______________________________-15 dBm to -8 dBm (9/125 µm)
Supported Link Length _______________________________up to 15km full duplex
Cable Type __________________________ 8.3/125, 8.7/125, 9/125, 10/125 µm F/O
Singlemode Fiber Optic Interface — long haul distance support
Connector ________________________________________________________ SC
Wavelength ___________________________________________________ 1310 nm
RX Input Sensitivity ____________________________________-35 dBm minimum
Output Power ________________________________ -5 dBm to 0 dBm (9/125 µm)
Supported Link Length _______________________________up to 40km full duplex
Cable Type __________________________ 8.3/125, 8.7/125, 9/125, 10/125 µm F/O

20 User Guide
Metrobility T3/E3 21
Singlemode Fiber Optic Interface — extended long haul distance support
Connector ________________________________________________________ SC
Wavelength ___________________________________________________ 1550 nm
RX Input Sensitivity ____________________________________-37 dBm minimum
Output Power _______________________________ -3.0 dBm to 0 dBm (9/125 µm)
Supported Link Length ______________________________up to 100km full duplex
Cable Type __________________________ 8.3/125, 8.7/125, 9/125, 10/125 µm F/O
Singlemode BWDM Fiber Optic Interface
Connector ________________________________________________________ SC
Supported Link Length _______________________________up to 20km full duplex
Cable Type _______________________________________________9/125 µm F/O
(2115-2X-01, 2175-2X-01)
TX Wavelength ______________________________________________ 1550nm
RX Wavelength ______________________________________________ 1310nm
RX Input Sensitivity __________________________________-32 dBm minimum
Output Power______________________________-8 dBm to -15 dBm (9/125 µm)
(2115-2Y-01, 2175-2Y-01)
TX Wavelength ______________________________________________ 1310nm
RX Wavelength ______________________________________________ 1550nm
RX Input Sensitivity __________________________________-32 dBm minimum
Output Power______________________________-8 dBm to -15 dBm (9/125 µm)
Data Rate
Data Rate ______________________________44.736Mbps (T3); 34.368Mbps (E3)
Power
Input ______________________________________+5.0VDC @ 0.4A, 2W average
Environmental
Operating Temperature ________________________________________ 0° to 55° C
Storage Temperature ________________________________________ -30° to 70° C
Relative Humidity_______________________________ 5% to 95% non-condensing
Physical Case _____________________________ Fully enclosed metal construction
Dimensions _____________________________________4.38"L x 3.26"W x 1.71"H
______________________________________12.3 cm x 8.3 cm x 4.3 cm
Weight (including power supply) _______________________________ 3 lb, 1.36 kg
This manual suits for next models
15
Table of contents
Other Telco Systems Media Converter manuals
Popular Media Converter manuals by other brands

Atlona
Atlona OmniStream AT-OMNI-121 manual

UCONNECT INTERNATIONAL
UCONNECT INTERNATIONAL BLE RS-232 user manual

Moxa Technologies
Moxa Technologies NPort 5110A Quick installation guide

Speaka Professional
Speaka Professional SP-5965732 operating instructions

Seneca
Seneca Z201-H quick start guide

Expert
Expert EX-9543 user manual