Telect nrgSMART nrgCONTROL-BT User manual

© Telect, Inc., All Rights Reserved, 145122-1 A0
1.509.926.6000 :: telect.com
nrgCONTROL-BT
Power :: nrgSMART™ Controller with
Bluetooth®
Installation Guide
nrgSMART describes the family of distributed network
monitoring and management products, from BDFB’s, high
current and low current secondary panels, as well as Web
interface software and data server solutions. nrgSMART
allows you to collect performance data on distributed assets
and tools to help you efficiently access business critical and
actionable information.
Telect recognizes the industry need to manage distributed
assets more efficiently, get better power performance out of
deployed assets, as well as pursue realistic and achievable
alternative energy goals. Through nrgSMART, access to data
at the equipment level provides the foundation for managing
performance of a distributed DC power distribution system.
• Individual circuit monitoring: measure power at
the circuit level. This enables powerful trend analysis
and insights into equipment performance and enables
preventative maintenance processes.
- High accuracy, 100% passive monitoring,
modular sensor modules
• Collect feed voltage, circuit current, and temperature
• Network Data Collection: Intelligent interpretation of the
collected data, based on equipment data signature (smart
alarms), drives relevant business decisions.
-Hosted Data Services available through the
nrgSMART-ADH service
- SNMP Interface comes standard when used with
the nrgCONTROL-BT
• Data Analytics: With the nrgCONTROL-BT and
nrgSMART-ADH Service, the nrgSMART panels can be
remotely monitored through the nrgSMART web portal
and dashboard views. Remotely access the data that is
important to you. Instantly see real-time results at any of
your distributed sites.
nrgCONTROL-BT

© Telect, Inc., All Rights Reserved, 145122-1 A0
1.509.926.6000 :: telect.com
ii
nrgCONTROL-BT
Power :: nrgSMART™ Controller with
Bluetooth®
1.1 Overview .........................................................................................................................1
1.2 Specications ..................................................................................................................2
1.3 Installation .......................................................................................................................3
1.4 nrgCONTROL nrgNET Connectivity................................................................................4
1.5 nrgCONTROL WAN Connectivity ....................................................................................5
1.6 nrgCONTROL LAN Connectivity .....................................................................................6
2.0 nrgCONTROL-BT Dimensions .......................................................................................7
Figure 1 - nrgCONTROL-BT Front View................................................................................1
Figure 2 - nrgCONTROL-BT Rear View ................................................................................1
Figure 3 - nrgCONTROL-BT DC Power Pin Out ...................................................................1
Figure 4 - Bracket Orientation as Shipped............................................................................3
Figure 5 - Bracket Orientation for Rack Mounting.................................................................3
Specications........................................................................................................................2
Table of Contents
Figures
Tables

© Telect, Inc., All Rights Reserved, 145122-1 A0
1.509.926.6000 :: telect.com 1
nrgCONTROL-BT
Power :: nrgSMART™ Controller with
Bluetooth®
1.1 Overview
Telect’s nrgCONTROL-BT coordinates and collects data for
30 nrgSMART enabled devices. Panels are connected over
a simple daisy chain connection. One IP address is all that is
required for all attached PDU panels.
For new deployments the controller interface is built into the
nrgBDFB. For expansion, single rack deployment, or outdoor
enclosures we provide the 1RU controller.
The nrgCONTROL-BT is capable of connecting to DC power
in the range of -20 to -57V. Redundant power input is also
congurable based on the pin-out description in Figure 3.
Using nrgSMART Hosted Data and the Web portal provides
network wide access and visibility to sites that deploy the
nrgSMART controller/PDU panels. Get real-time data
such as current, voltage, breaker trips or blown fuses, and
temperature for individual circuits. Uniquely identify and label
assets to their individual circuit. It is now possible to track
performance based on asset.
Figure 2 – nrgCONTROL-BT Rear View
Figure 3 – nrgCONTROL-BT DC power pin out
Pin Number Feed Voltage Polarity
Pin 1 A feed Positive voltage
Pin 2 A feed Negative voltage
Pin 3 B feed Positive voltage
Pin 4 B feed Negative voltage
Pin 1
Pin 2
Pin 3
Pin 4
Figure 1 – nrgCONTROL-BT Front View

© Telect, Inc., All Rights Reserved, 145122-1 A0
1.509.926.6000 :: telect.com
2
nrgCONTROL-BT
Power :: nrgSMART™ Controller with
Bluetooth®
1.2 Specications Important Installation Guidelines
• Elevated Operating Ambient - If you install this product
in a closed or multi-unit rack assembly, the
operating ambient temperature of the rack environment
may be greater than room ambient. Therefore,
consider installing the equipment in an environment
compatible with the maximum ambient temperature.
• Reduced Air Flow - When you install this equipment in
a rack, make sure you do not compromise the amount of
air ow required for safe operation of the equipment.
• Mechanical Loading - When you mount the equipment
in the rack, make sure to keep the mechanical load
balanced to prevent a hazardous condition.
• Circuit Overloading - Pay attention to the connection
of the equipment to the supply circuit and the effect that
overloading of the circuits might have on overcurrent
protection and supply wiring. Appropriately consider
equipment nameplate ratings when addressing this
concern.
• Reliable Earthing - Maintain reliable earthing of rack-
mounted equipment. Pay particular attention to supply
connections other than direct connections to the branch
circuit (e.g., use of power strips).
• Disconnect Device - Incorporate a readily available
disconnect device into the building installation wiring.
Inputs/Outputs Specication
Connection to Conguration
Wizard
10/100 Ethernet, RJ-45 jack
Connection to data server 10/100 Ethernet, RJ-45 jack
Connection to nrgSMART
panels
nrgNET
Voltage range (nominal) -20V to -57V (nominal -48 VDC)
Input power wire size #18-12 AWG
Max. operating current 3A (80% of 4A fuse rating)
SD card capacity 4 Gigabytes
SD card type Micro SD
Grounding Specication
Earth GND terminal bolts
(with washers) for dual-hole
compression lug
Two pair of 1/4-20 threaded
holes on 5/8-in. centers. Torque
bolts (using 7/16-in. or 12 mm
wrench) to 50-in./lb. (5.5 N•m),
max.
Environmental Specication
Temperature -5° to 55°C (23° to 131°F)
Humidity 0 to 90%, non-condensing
Mechanical Specication
Dimension 17" W x 1.73" H x 8.99" D
Weight 8.7 lbs (10.7 lbs shipping)
Material Cold-rolled steel
Finish Gray, powder coat
Mounting 19" or 23" rack mounting; EIA
and WECO
Compliance
UL, NEBS level 3 pending

© Telect, Inc., All Rights Reserved, 145122-1 A0
1.509.926.6000 :: telect.com 3
nrgCONTROL-BT
Power :: nrgSMART™ Controller with
Bluetooth®
ALERT! Verify that all connections meet requirements
specied in local electric codes or operating company
guidelines before supplying power. Unit shall be protected by
a listed circuit breaker or branch-rated fuse rated maximum
10A.
INSTALL THIS PRODUCT WITHIN A RESTRICTED ACCESS
LOCATION WHERE ACCESS IS THROUGH THE USE
OF A TOOL, LOCK AND KEY, OR OTHER MEANS OF
SECURITY AND IS CONTROLLED BY THE AUTHORITY
RESPONSIBLE FOR THE LOCATION. ONLY QUALIFIED
TECHNICIANS MAY INSTALL AND MAINTAIN THIS
PRODUCT.
1.3 Installation
NOTE: Do not remove terminal protection brackets, until
panel is installed in a rack. If the panel is transported outside
of the shipping container, make sure the terminal protection
brackets are installed.
Inspection
Please read and understand all instructions before starting
installation. If you have questions, contact Telect Technical
When you receive the equipment, carefully unpack it and
compare it to the packaging list. Please report any defective
1.509.926.6000.
Telect is not liable for transit damaged. If the product is
damaged, please report it to the carrier and contact Telect
Quality.
NOTE: For service or warranty information, please visit the
telect.com website, or email inquiries to getinfo@Telect.com
and click on the “Support” tab, or phone us at 800.551.4567
(domestic only) or 509.926.6000.
NOTE: The nrgCONTROL-BT is suitable for installation
as part of both a Common Bonding Network (CBN) and
Isolated Bonding Network (IBN) for installation in Network
Telecommunications Facilities and OSP.
Rack Mounting
• The nrgCONTROL-BT panel can be mounted in 19-in. &
23-in. EIA and WECO racks.
• The nrgCONTROL-BT panel can be ush-mounted to 4-in
extended in 1/2" increments.
1. Unscrew the mounting brackets from the panel and turn
them to the mounting position. See Figures 4 and 5 below.
2. Locate an unused rack position and mount panel to the
rack using the screws provided. It is best to mount the
panel as high as possible on the rack.
3. Tighten screws to 35 in.-lb (4.29 N•m). Telect
recommends using a seismic rack for best rigidity. Also,
if you intend on installing more than one panel per rack,
you need to plan a rack arrangement that dissipates heat
efficiently.
WARNING! Failure to properly ground this equipment can
create hazardous conditions for installation personnel and for
the equipment.
WARNING
!
ALERT
!
Figure 4 - Bracket Orientation as Shipped
Figure 5 - Bracket Orientation for Rack Mounting

© Telect, Inc., All Rights Reserved, 145122-1 A0
1.509.926.6000 :: telect.com
4
nrgCONTROL-BT
Power :: nrgSMART™ Controller with
Bluetooth®
1.4 nrgCONTROL nrgNET Connectivity
nrgNET is Telect’s proprietary communication link between
nrgSMART panels and the nrgCONTROL controller. The
connection uses a single cable with four conductors to provide
power and data communication.
nrgNET 1 and nrgNET 2 leg
outputs to nrgSMART panels.
nrgNET 1 and nrgNET 2 leg power fuses.
Standard GMT style (4A).
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin Number Label Wire Color
Pin 1 COM + White
Pin 2 COM - Blue
Pin 3 SHLD Drain wire
Pin 4 PWR + Black
Pin 5 PWR - Red
nrgNET Pin Outs

© Telect, Inc., All Rights Reserved, 145122-1 A0
1.509.926.6000 :: telect.com 5
nrgCONTROL-BT
Power :: nrgSMART™ Controller with
Bluetooth®
1.5 nrgCONTROL WAN Connectivity
The nrgCONTROL WAN port located on the back of the unit
is used to connect the controller to the data storage location
options.
The controller can be operated in the following modes:
1. Local Only Mode
• No WAN connection required.
• The controller will collect data from all panel sensors that
are connected to it over the nrgNET interface.
• No SNMP traps or data is sent for monitoring.
• Data is stored locally on the included micro SD card.
• The instantaneous sensor data can be viewed from
the front of the controller’s LCD screen for all attached
monitoring panels.
2. SNMP Mode
• The WAN port must be connected and congured to
operate on the same subnet as the customer dened
SNMP/NMS server address.
• The nrgSMART MIB table is available for download at the
following URL: www.nrgPORTAL.telect.com/MIB
• SNMP traps can be set-up for current threshold
crossings, breaker trips or blown fuses, voltage threshold
crossings, and temperature threshold crossings.
• Sensor data and conguration data can be polled by
issuing commands from the NMS.
• The NMS will have to manage and store all collected
data.
3. Telect Hosted Data Mode
• The WAN port must be connected and congured to the
nrgETL1.Telect.com domain name.
• The user must accept the Telect Hosted Data terms and
conditions to send data to the hosted service.
• The Telect hosted data service manages user portal
conguration, site equipment deployment congurations,
and provides access to data analytic views of collected
sensor data over the customer’s entire deployed network
of nrgSMART panels.
• Options are available to deploy user managed data
servers behind a customer’s rewall. Contact your eld
representative to setup a site survey discussion for server
deployment options.
4. SNMP and Telect Hosted Data Mode
• Both SNMP traps and Telect data hosting can be
operated simultaneously.
RJ-45 WAN port.
For information on connecting and conguring your nrgSMART panels, please refer to nrgSMART Conguration Guide.

© Telect, Inc., All Rights Reserved, 145122-1 A0
1.509.926.6000 :: telect.com
6
nrgCONTROL-BT
Power :: nrgSMART™ Controller with
Bluetooth®
1.6 nrgCONTROL LAN Connectivity
1. Connect a CAT5 cable to the front panel LAN connector of the nrgCONTROL-BT panel.
2. The laptop should be setup to receive DHCP addresses. The controller will assign a valid local IP address.
3. Using a web browser, navigate to 192.168.1.1.
4. The Conguration Wizard will be displayed.
For information on connecting and conguring your nrgSMART panels, please refer to nrgSMART Conguration Guide.
RJ-45 LAN port.
The
Bluetooth
®
word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by Telect is under license. Other
trademarks and trade names are those of their respective owners.
Apple, iPod, iPhone, and iPad are trademarks of Apple Inc., registered in the U.S. and other countries.

© Telect, Inc., All Rights Reserved, 145122-1 A0
1.509.926.6000 :: telect.com 7
nrgCONTROL-BT
Power :: nrgSMART™ Controller with
Bluetooth®
Telect assumes no liability from the application or use of these products. Neither does Telect convey any license
under its patent rights or the patent rights of others. This document and the products described herein are subject
to change without notice.
2.0 nrgCONTROL-BT Dimensions

© Telect, Inc., All Rights Reserved, 145122-1 A0
1.509.926.6000 :: telect.com
8
nrgCONTROL-BT
Power :: nrgSMART™ Controller with
Bluetooth®
FCC Class A Notice
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This
device many not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of
the FCC Rules. These limits are designed to provide a reasonable protection against harmful interference when the equipment
is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if
not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required
to correct the interference at his own expense.
Modication
Any modications made to this device that are not approved by Telect Inc. may void the authority granted to the user by the
FCC to operate this equipment.
ICES-003 Class A Notice - Avis NMB-003, Classe A
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
WARNING! The intra-building port of the equipment is suitable for connection to intra-building or unexposed wiring or
cabling only. The intra-building port of the equipment MUST NOT be metallically connected to interfaces that connect
the OSP (Outside Plant) or its wiring. These interfaces are designed for use as intra-building interfaces only (Type 2
or Type 4 ports as described in GR-1089) and require isolation from the exposed OSP cabling. The addition of Primary
Protectors is not sufficient protection in order to connect these interfaces metallically to OSP wiring.
WARNING
!
ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS
ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS! When handling any electronic component or assembly you must
observe the following antistatic precautions to prevent damage. Always disconnect power from the server and wear a
grounded wrist strap when working around the nrgCONTROL-BT. Always wear a grounded wrist strap when handling
printed circuit boards. Treat all assemblies, components, and interface connections as static-sensitive.
Table of contents