2 05/06/2019 Update DP, FL DP, FL
MAS-AA600-REV02EN Page 1 of 56
AA-600/SM5x
IP Intercom Audio&Video VoIP SIP / PoE Module
TECHNICAL MANUAL – INSTALLATION
PRELIMINARY DOCUMENTATION
HW Version 1.0 – SW Version 1.10
WWW.TEMATLC.IT
Recommendations
1. Use only original spare parts and consumables supplied by Tema Telecomunicazioni Srl for this equipment. The company shall not be
held responsible for any damage caused by the use of materials that they have not supplied.
2. The device has been carefully manufactured and tested. In any case, the product is not recommended for use in situations in which
incorrect operating may result in damage to persons and/or property.
3. We recommend that you carefully read all this manual before starting to use the device.
4. Do not expose the device to sunlight and protect it from sources of heat, dust, humidity and chemical agents.
5. This manual is the property of Tema Telecomunicazioni Srl and any duplication and reproduction, even partial, as well as storage on
any type of media is forbidden without written permission from Tema Telecomunicazioni Srl.
TEMA TELECOMUNICAZIONI S.r.l.
Telecommunications - Electronics

TEMA TELECOMUNICAZIONI SRL
IP Module AA-600
MAS-AA600-REV02EN Page 2 of 56
We, TEMA TELECOMUNICAZIONI SRL Via C. Girardengo, 1/4 - 20161 MILANO
declare under our sole responsibility that the product:
product name
Modulo Intercom Audio e Video VoIP SIP / PoE
trade name TEMA TELECOMUNICAZIONI Srl
type or model AA-600
and accessories
to which this declaration relates is in conformity with the essential requirements and other
relevant requirements of the R&TTE Directive ( 1999/5/EC, 2006/95/EC, 2004/108/EC ).
The product is in conformity with the followings standards and/or other normative documents:
HEALT & SAFETY EN 60950-1:2006
+A11:2009
+A1:2010
+A12:2011
EMC EN 55022:2010
EN 55024:2010
EN 61000-3-2:2006
EN 61000-3-3 :2008
MILANO, 28 May 2019 TEMA TELECOMUNICAZIONI SRL
D. Pontillo
I.
IMPORTANT INFORMATIONS REGARDING THE RECOVERY AND RECYCLING OF THIS ELECTRONIC DEVICE
The crossed-out wheeled bin symbol below indicates that this electronic equipment is intended to be disposed in a separate collection and not in
an unsorted municipal waste, in order to provide for the treatment of WEEE (Waste Electrical and Electronic Equipment) using best available
recovery and recycling techniques.
Specific treatment for WEEE is indispensable in order to avoid the dispersion of pollutants and other hazardous substances into the waste
stream, while recycling leads to reduction of disposal of waste and the negative impacts on environment and human health. That is, priority is
given to reuse of WEEE in its components, subassemblies and consumables.
As the final holder, the user has an important role in contributing to reuse, recycling and other forms of recovery of WEEE and is responsible to
return this waste in the collection facilities set up by EC Member Stases and to fulfill other duties in compliance with Directive 2002/96/EC and
local laws.
DICHIARAZIONE DI CONFORMITÀ CE
DECLARATION OF CONFORMITY CE

TEMA TELECOMUNICAZIONI SRL
IP Module AA-600
MAS-AA600-REV02EN Page 3 of 56
RECOMMENDATIONS
1. It is recommended to read this entire manual before proceeding to the installation of the device.
2. The installation and commissioning of the device can only be performed by specialized technicians.
3. The device is accurately manufactured and tested. In any case, the product is not recommended for use
where an error of operations can cause property damage and/or injury to persons.
4. It is expressly not recommended maintenance inside the device which must be carried out by Tema
Telecomunicazioni, the removal of the closures will invalidate the warranty and makes accessible internal
parts with risk of electric shock.
5. Tema Telecomunicazioni accepts no responsibility for damage to property and/or persons resulting from
incorrect use of the equipment or by procedures that do not comply with the instructions in this manual.
Tema Telecomunicazioni reserves the right to make modification to the technical and functional
specifications at any time and without any notice.
6. Products powered via PoE (Power over Ethernet) may only be connected with cables coming from the
internal network company (inside the building), are not allowed connections LAN cables coming from outside
the building.
7. Use for this device only and exclusively original spare parts and consumables supplied by Tema
Telecomunicazioni. The company is not responsible for damage caused by the use of materials not supplied
by the same.
8. Do not expose the unit to direct sunlight, protect from heat, dust, humidity and chemicals.
9. Tema Telecomunicazioni reserves the right to vary the product characteristics for improvement without prior
notice. Check the WWW.TEMATLC.IT website for any updates to the latest firmware, manuals, and
technical documentation.
10. This document is property of Tema Telecomunicazioni, It is forbidden any duplication and reproduction, even
partial, as well as storage on any medium without written permission of Tema Telecomunicazioni.
This symbol in the descriptions indicates a general warning or a damage danger
to equipment or people.
This symbol in the descriptions indicates useful information or a suggestion for
the optimization of the device functionality.
This symbol in the descriptions indicates a danger from electric shock due to damage to the
equipment or to people.

TEMA TELECOMUNICAZIONI SRL
IP Module AA-600
MAS-AA600-REV02EN Page 4 of 56
1. PRESENTATION ........................................................................................................................................ 5
2. GENERAL DIAGRAM ................................................................................................................................ 6
3. PACKING LIST ........................................................................................................................................... 6
4. GENERAL SPECIFICATIONS................................................................................................................... 7
5. TECHNICAL SPECIFICATIONS ............................................................................................................... 8
6. OPTIONAL ACCESSORIES...................................................................................................................... 9
7. OPERATION.............................................................................................................................................. 10
7.1.
P
USHBUTTONS AND NUMERIC KEYPAD EXPANSION
...............................................................................................10
7.2.
I
NSERTION SCHEME OF THE DEVICE AS
IP
SIP
DOOR PHONE INTERFACE
................................................................11
7.3.
O
THER APPLICATION SCHEMES
.........................................................................................................................12
8. INSTALLATION OF THE DEVICE .......................................................................................................... 13
8.1.
CONNECTION ..............................................................................................................................................13
9. PROGRAMMING ...................................................................................................................................... 15
9.1.
P
REPARING FOR PROGRAMMING SYSTEM PARAMETERS
.......................................................................................15
9.2.
A
CCESS TO PROGRAMMING AND RESET ADDRESS AND PASSWORD
........................................................................17
9.3.
N
ETWORK PARAMETERS
...................................................................................................................................18
9.4.
SIP
PARAMETERS
............................................................................................................................................19
9.5.
G
ENERAL PARAMETERS
....................................................................................................................................20
9.6.
S
ET OF THE OPERATING MODE
D
AY
/N
IGHT
/I
NTERVAL
,
K
EYBOARD
.........................................................................22
9.7.
D
AY
/N
IGHT
/I
NTERVAL MODES DESCRIPTION
........................................................................................................23
9.8.
D
AY
/N
IGHT
/I
NTERVAL COMMAND CODES FOR THE OPERATOR
...............................................................................23
9.9.
A
DDITIONAL FUNCTIONS OF THE NUMERIC KEYPAD EXPANSION
..............................................................................24
9.10.
R
ELAY AND ALARM INPUT SETTINGS
..............................................................................................................25
9.11.
A
CQUISITION OF INPUT CONTACTS
................................................................................................................26
9.12.
C
AMERA
....................................................................................................................................................28
9.13.
C
ALL BUTTONS
...........................................................................................................................................29
9.14.
M
ESSAGES MANAGEMENT
...........................................................................................................................31
9.15.
M
ULTICAST AUDIO STREAMING
.....................................................................................................................33
9.16.
A
UTOMATIC
A
NNOUNCEMENTS
.....................................................................................................................34
9.17.
RFID
MANAGEMENT
...................................................................................................................................36
9.18.
C
ALLS REPORT
...........................................................................................................................................37
10. MAINTENANCE........................................................................................................................................ 38
10.1.
S
YSTEM
....................................................................................................................................................38
10.2.
L
OGIN CREDENTIALS
...................................................................................................................................39
10.3.
D
IAGNOSTIC LOG
........................................................................................................................................39
11. "AA Video Console" SOFTWARE for PC installation....................................................................... 40
11.1.
P
RESENTATION
..........................................................................................................................................40
11.2.
S
OFTWARE CONFIGURATION FOR
SIP
S
ERVER MODE
.....................................................................................41
11.3.
S
OFTWARE CONFIGURATION FOR
P
EER
-T
O
-P
EER MODE
.................................................................................42
12. APPENDIXES............................................................................................................................................ 43
12.1.
A
PPENDIX
1:
M
ULTICAST
A
UDIO
S
TREAMING FOR ANNOUNCEMENTS
................................................................43
12.2.
A
PPENDIX
2:
U
SE OF THE
AUDACITY
SOFTWARE FOR AUDIO FILES RECORDING
...............................................44
12.3.
A
PPENDIX
3:
AA-697/MIC ..........................................................................................................................45
12.4.
A
PPENDIX
4:
AA-697/AP3 ..........................................................................................................................46
12.5.
A
PPENDIX
5:
AA-697/CAM
C
AMERA
............................................................................................................47
12.6.
A
PPENDIX
6:
AA-697/CLL
C
AMERA WITH
10
WHITE
LED
ILLUMINATORS
..........................................................48
12.7.
A
PPENDIX
7:
AA-697/P16
16
BUTTON INTERFACE BOARD
...............................................................................50
12.8.
A
PPENDIX
8:
AA-697/KV-KP
KEYBOARDS
....................................................................................................52
12.9.
A
PPENDIX
9:
LIGHT
INDICATORS .............................................................................................................54
12.10.
A
PPENDIX
10:
C
ABLING OF A
UTP
RJ45
NETWORK CABLE ACCORDING TO THE STANDARD
EIA568B...............55
INDEX PAGE

TEMA TELECOMUNICAZIONI SRL
IP Module AA-600
MAS-AA600-REV02EN Page 5 of 56
1. PRESENTATION
The AA-600 series IP modules allow the creation of customized communication devices on a LAN network ranging
from VoIP Video Doorphones telephony systems, hands-free intercoms, IP amplifiers for PA (Public Address Audio
Paging) broadcasting of announcements and music, up to Actuator Systems of Security and Emergency. The
modules are designed to be integrated into devices and systems customized by the customer, for example:
• Conversion of old intercoms into LAN IP video Doorphones
• VoIP Doorphones with customer mechanics
• Emergency-Information columns
• Access and gate control, entrances, gates and barriers
• Use as a communication system for public access machines (Bancomat, Ticket machines, Distributors, etc.)
• Communication, security and music broadcasting in elevators
• Audio amplification and announcements broadcast on LAN network
• Realization of IP SIP speakers
• Signaling, Warning and Emergency systems
The AA-600 modules are two-way communication systems. In the simplest application it is sufficient to connect a
microphone, a speaker and a button to create a complete VoIP SIP PoE communication system integrated in the
LAN with 2 internal relays that can be remotely activated.
For more complete realizations other accessories are available:
• Mini USB color camera
• 12 keys telephone vandal-proof keypad
• RFID cards and tag reader
• Additional buttons
• Additional internal 20W audio amplifier
Total Management via LAN, integrated Web Server
Programming, configuration, loading and listening of audio files, firmware update, audio volume adjustment,
backup, configuration reset, device reboot.
Recorded messages
Inside the SD card are recorded sounds and messages for automatic or specific command sending. The messages
can be customized by the user and can be loaded remotely via LAN.
iOS and Android APP, Videoconsole Software for PC and ADAM
Free APPs are available for smartphones with iOS and Android operating systems that interact with the AA-600
modules on the network. A management software is supplied to be installed on a Windows PC for the management
of 1 to 16 modules. For advanced applications, the ADAM Audio Domain & Access Management software is
available, able to supervise all devices on the network with Multi-zone microphone console functions for
announcements.
Integration in telephone VoIP SIP and security systems
AA-600 integrates perfectly with VoIP telephony systems (IP-PBX) with SIP protocol that can be registered as a
normal VoIP phone or in Peer-to-Peer (P2P) mode without a PBX.
Tested with the most popular PBX brands:
SIEMENS/UNIFY - AVAYA - ALCATEL – PANASONIC – SAMSUNG - NEC
3CX - LG ERICSSON - WILDIX - AASTRA - ASCOM - NITSUKO – SELTA
PHILIPS - MITEL – YEASTAR - ZYCOO – CISCO – EPYGI ELASTIX
GRANDSTREAM – SHORETEL - NORTEL – SWYX – XORCOM – ASTERISK
BASED SYSTEMS SOFTPHONE OF DIFFERENT MANUFACTURERS

TEMA TELECOMUNICAZIONI SRL
IP Module AA-600
MAS-AA600-REV02EN Page 6 of 56
2. GENERAL DIAGRAM
3. PACKING LIST
The system consists of the parts included in the following list:
•One module AA-600-SM5xx
•Accessory parts such as microphone, speaker, camera, etc. according to customer order
•A CD with system documentation
•A quick guide
APP for iOS and Android
Management of 4
terminals
ADAM
Management and
Supervision software for an
unlimited number of AA-600
systems on the LA network
“Videocons
ole” Software for
PC Windows 7/10,
Management of 16 terminals
SO
FTWARE
MANAGEMENT
APP an VIDEOCONSOLE
SOFTWARE
Microphone
Local
Speaker 2-3W
Keypad
LA PoE cable
Vin +/
-
12
/24
Vdc
–
12
/18
Vac
Vout +/
-
12Vdc Max 200mA
Call Button
HD USB
Camera
2nd Speaker 2
-
3W
(10-20W 8Ohm with
SM52/SM52V model)
Active Call
LED
Input from external alarm contact
Relay 1 (
change
-
over contact
)
Relay 2 (closing contact)
125KHz RFID proximity reader for
cards and tags, extensible RS-485
port, 2 additional relays. Another 7
units c
an be connected on the
RS-485 bus
16 External
Buttons board
(alternative to
keyboard)
Additional
board
RS-485
Illuminators board
10 white LEDs
AA
-
600

TEMA TELECOMUNICAZIONI SRL
IP Module AA-600
MAS-AA600-REV02EN Page 7 of 56
4. GENERAL SPECIFICATIONS
•
Sending of a phone call when a key is pressed on the device
•
Programming via Web interface with password protection
•
Day/Night/Interval operating mode with manual or automatic setting for different call destination numbers
•
2 door opener relays for the possibility of operating a second electric lock, for example to make the
distinction between the pedestrian passage and the driveway gate
•
Up to 6 programmable codes, 3 for each relay associated with the electric lock, to be able to control the
relays directly from the intercom without operator intervention
•
Setting of the Day/Night/Interval operating mode which can be performed from the telephone or automatically
with time slots, setting retained even after a power failure
•
Great versatility coupled with ease of use and programming
•
High quality hands-free conversation
•
Possibility of software / firmware update via LAN
•
Possibility to acquire 1 external contact to the system and alert service with dedicated message
•
Possibility of receiving and sending in RTP MULTICAST audio streaming, for audio paging announcements,
up to 16 MULTICAST priority levels (in reception) and with different volumes for each channel
•
Possibility to register a second SIP account for use as a “Night Ringer” night ringtone group
•
Possibility to condition the connection for incoming calls with only listening or conversation codes
•
"Push-to-talk" function, to be associated with an available input
•
Manual "Door opener" function with internal button, to be associated with any of the available inputs
•
Audio streaming playback with high quality codec
•
Possibility of issuing pre-recorded announcements at set times (up to 5 for each day of the week)
•
Possibility of issuing a daily pre-recorded announcement, at a set time or manually, with programmable
interval and repetitions
•
Possibility of broadcasting a pre-recorded announcement, associated with each available entry, or by making
a call and sending a code by phone
•
Models with RFID option for card reader or wireless TAG with access control function, activity log
•
Use of the RFID code table to recognize codes entered from the keyboard
VoIP IP LAN section
•
Integration with local LAN, Ethernet LAN 100 BaseT port with RJ45 connector
•
VoIP connection with SIP protocol both in SIP Proxy Server and Peer-to-Peer mode, PoE (Power over
Ethernet) power supply possibility
•
Up to 2 programmable numbers that can be contacted for each button, plus any supervisor and call cycles;
possibility to associate a SIP extension number or an IP address, depending on the SIP Proxy Server or
Peer-to-Peer connection mode
Integrable color camera
•
Integrated color camera
•
Video Streaming on IP phone with video support, on PC using a web browser or using the supplied "AA
Video Console" software
•
Image storage: picture taken when the call button is pressed by the visitor with the possibility of sending it via
e-mail in real time

TEMA TELECOMUNICAZIONI SRL
IP Module AA-600
MAS-AA600-REV02EN Page 8 of 56
5. TECHNICAL SPECIFICATIONS
Generals
Insertion terminals for wiring
Possibility of using cables up to 1.5mm2 or AWG16
Number of integrated relays
2
Max relay contacts rating
Up to
2A
-
30V
Main unit power supply
12V
DC
/ V
AC
, 900mA
max absor
ption
Container material
ABS Novodur
®
Mounting Type
Fixing in host devices
Operation temperature
From
-
20
˚C
to
+50
˚C
Relative humidity
95% non
-
condensing
VoIP
PoE
Power Suplly
According to IEEE 802.3af
(only for system power supply, not for electric locks)
LAN
Ethernet LAN 100 BaseT
port
S
upport
ed
VoIP
p
rotocol
s
SIP v2
Mode support
SIP Server o
r
Peer
-
to
-
Peer
modes
Protocols
IP, TCP, UDP, HTTP
, TELNET, SIP, RTP
Bandwidth
300
–
3400 Hz
(7KHz with
G722
codec
)
A
udio
c
odec
G711µ, G711a, G722, 16
-
24
-
32 kHz
Echo suppressor
Yes
MULTICAST
A
udio
Streaming
Yes
Inputs
Number of acquisition inputs
1
fo
r
call
conta
c
t, 1
for
alarm
Camera expansion accessory
Type
Color camera
V
ideo
re
solu
t
ion
640x
480
/ 352x
288
/ 320x
240
/ 176x
144
Vision angle
70°
Vid
eo output
IP
Video streaming
, H.263, H.263+, H264

TEMA TELECOMUNICAZIONI SRL
IP Module AA-600
MAS-AA600-REV02EN Page 9 of 56
6. OPTIONAL ACCESSORIES
(The images shown are indicative, may vary due to production needs)
A
A
-
39DL
Plug Power Supply 220Vac/12Vdc-1,0A.
AA
-
39D1A, AA
-
39E3 /AA
-
39E6V
AA-39D1A P. Supply DI 220Vac/15Vdc-1,0A
AA-39E3 P. Supply DI 220Vac/24Vdc-1,5A
AA
-
39E6V P. Supply DI 220Vac/24Vdc
-
2,5A
AA
-
39P4
PoE injector 230Vac/48Vdc 0,5A.
AA
-
699/L10A
/X20R/X10B
Flash warning lights with Xeon lamp or with
high brightness LEDs, with a call in progress
they add a light signal to the acoustic signal.
AA
-
36
250Vac/16A/4KVA power relay, AC/DC
12V/24V control, 1 change-
over contact, LED
indicator, for loads up to 230Vac-4.000W.
AD330/15T, AD335/06TP, …
Horn speaker and additional speakers from
6W to 30W with 100V line transformer.
AA
-
697/MIC
High sensitivity omnidirectional microphone,
cable for call button, in protected ABS case,
wired with connector.
AA
-
697/AP3
Waterproof 8 Ohm-
3W loudspeaker in ABS
plastic enclosure, incorporating a high-
efficiency LED indication of call
in progress,
pre-wired with cable and connector.
AA
-
697/KP
–
AA
-
697/KV
Backlit vandal-proof keypad for indoor/
outdoor
use in ABS case wired with 25cm cable and
10WAY connector.
Also available in indoor
version with plastic buttons.
AA
-
697/CAM
USB HD camera in ABS enclosure wired with
25cm cable and 10-WAY connector.
AA
-
697/CLL
USB HD camera and illuminators board 10
white LE
Ds, 25cm cable and 10WAY
connector.
AA
-
697/xxx
125KHz RFID reader card on RS-
485 bus and
2 additional relays for remote operation via
LA . The unit is pre-wired. Another 7 unit
s
can be connected on the RS-485 bus.
AA
-
697/xxx
Card with communication port on RS-
485 bus
and 2 addition
al relays for further remote
operation via LA . Max 8 cards on the RS-
485 bus for a total of 16 relays.
AA
-
697/P1
Steel metal button with 25cm cable.
G2130/G3140/G3240/G3275/…
IP VoIP SIP phones and video phones for
indoor stations and VoIP/Multicast calls.
AA
-
697/W4
–
W10
4 and 10 way connectorized cables, length
25cm, free end on the other side.
AA
-
697/P16
16 additional buttons interface board.
The board is an alternative to the keyboard.
AA
-
697/P32
-
64
CPU board RS-485 interface 32-
64 buttons,
allows the presence of the keyboard.
APP iOS/An roi , AA
-
Vi eoconsole
APP for iOS and Android
, Software
VideoConsole for Windows PCs.
ADAM
management software
Audio Domain & Access Management
Software for Windows PC with Multi-
Zone
console.
Other components
coming
soon
AA
-
697/DIN
Kit for mountin
g the modules on a DI rail
con
sisting of an Abs coupling + 50mm galvanized
bracket + 2 screws.
AD696/CT
Multi
-
Zone Console
Multicast and telephone SIP P2P multi-
function Console and multi-zone f
rom 4 to
256 zones.
AD696/BM base, AD615/S IP Enco er
Microphone base with Chime, Multicast
analog/digital encoder.
NOTE: for additional products and
accessories see
also the series lines SipComPoint and SipComStage.

TEMA TELECOMUNICAZIONI SRL
IP Module AA-600
MAS-AA600-REV02EN Page 10 of 56
7. OPERATION
The description of the operation in this manual for the AA-600 model is generally applied to the basic module, but
some services will only be available for modules equipped with specific parts (for example the camera, the number
of buttons, the expansion modules...).
When in stand-by the button is pressed, the AA-600 automatically generates a phone call via the VoIP PBX. The
visitor starts to listen to the result of his access request from the AA-600 loudspeaker, or he will listen to the call
control tone and the subsequent answer from the called operator.
Optionally, before the call is forwarded, it is possible to set the broadcast of a message that can be combined with
each key and each mode of operation, for example "The company is closed, wait for the custodian to answer ...".
The operator who has spoken to the visitor can decide to activate the electric lock by directly entering the correct
sequence of DTMF digits appropriately programmed (door opening codes), and hang up at the end of the
operation. When the operator hangs up, AA-600 will return to the rest state recognizing the PBX reorder and will be
ready for a new access request.
It is also possible for the operator, or for other extensions that can reach the AA-600 phone number, to connect on
their own with AA-600, to speak with people close to the entrance and possibly activate the electric lock without
waiting for a their call. It is also possible to protect this function with a connection / listening password.
When equipped with a camera, it is possible to see the framed area. The video of the camera is transported on an
IP Stream directly on the company LAN using the same LAN connection cable of AA-600. It is possible to see the
area framed on an IP phone with video functionality or directly on a PC via a normal browser or through the
"Videoconsole" supplied software.
7.1. Pushbuttons and numeric keypad expansion
By adding a telephone keypad to the module (only prepared versions), it is possible to obtain other services such
as direct dialing of the extension to contact or other services that assume the presence of a keyboard.
It is possible to allow, for example, access to company employees by making them aware of a code (the function
can be activated or excluded) so that they access without the need for operator intervention, simply by typing this
code on the keyboard preceded by the asterisk key (*).
The asterisk must be composed to indicate to the system that an access code is being entered rather than a
number to be selected. It is possible to define codes that work only in day mode, others that work only in night
mode or during the interval.
AA-600 can be used as an external VoIP Doorphone unit that can be connected to any IP-PBX, as a SIP extension
on a LAN network, with the possibility of powering both via an external power supply, or via PoE power supply on
the LAN network. AA-600 can alternatively be used in a Peer-to-Peer connection.
AA-600 is installed on the threshold of the gate to be controlled and when an external visitor presses the key, it
makes a VoIP telephone call to the number of the internal operator in charge of managing the inputs, allowing
audio communication between the interlocutors. The operator can command the opening of the electric lock of the
gate or pedestrian passage directly from his phone with a DTMF code.
Moreover, thanks to the integrable color camera, it is possible to see the visitor directly on the internal operator's IP
video phone or on the screen of his PC with a normal internet browser open, thus ensuring the maximum
operability/security of the monitored area. Tema also offers advanced systems management software.
The device can be housed in a prepared box, mounted directly on the wall or, using an optional accessory,
mounted on DIN rail.

TEMA TELECOMUNICAZIONI SRL
IP Module AA-600
MAS-AA600-REV02EN Page 11 of 56
7.2. Insertion scheme of the device as IP SIP door phone interface
AA-600 is connected to the PBX via the LAN on the RJ-45 port. The relay contacts will be used to operate an
electric lock and/or for example a lamp at the entrance to the gate or for the pedestrian gate and/or driveway gate.
The figures below show connection examples of AA-600:
•
The visitor who presses one of the keys will be put in contact with the internal extension of the operator
who will be able to decide to activate the electric lock and give him access to the company from his
telephone. In the same way it is possible to decide to open the driveway instead to make him enter with the
vehicle.
•
The operator who has been able to video monitor the installation area of AA-600-IP remains the possibility
to directly operate the two possible access routes without waiting for the visitor to press the buttons to
make the call on the Doorphone.
•
During the Night service, the operator is no longer present in the company, the call can be made to a
phone number of a caller who, for special needs, could open the gates and make enter the visitor remotely
from his mobile phone.
•
The two integrated relays could be used, in the other case, one for the gate and the second to activate a
lighting system for the entrance area.
Conversion of a tra itional Doorphone with push-button panel into a VoIP-SIP one
Traditional
Doorphone
By means of the AA
-
697/P16 interface it is possible to adapt an external
doorphone
with push
-
button
panel up to 16 buttons to the VoIP module AA-600. Each button will activate a Peer-to-Peer call to a
specific address that will reach the assigned extension. All extensions can operate the relays. In the
presence of an IP-PBX switchboard the functions are the same.
UTP cat 5/6
cable
AA
-
697/AP3 Speaker
AA
-
600/SM51
Rel
ay
2
Rel
ay
1
AA
-
697/MIC Microphone
Doorphone buttons
220Vac
Internal IP SIP
Phones
Generic Switch
AA
-
39P4
PoE Injector
AA
-
697/P16
16 buttons
board
Cavo UTP cat 5/6
AA
-
697/AP3 Speaker
PO and internal
network
phones
IP PBX
Switch PoE
Smartphone
Access Point
Transformation of a tra itional oor
phone system into a
VoIP
-
SIP
oo
r
phon
e
(IP
-
PBX)
AA
-
600/SM51
Existing
traditional
Doorphone
Rel
ay
2
Rel
ay
1
AA
-
697/MIC Microphone
Doorphon
e button
A traditional doorphone, of any brand, becomes a VoIP
-
SIP doorph
one by installing the AA
-
600/SM51
module in the flush box powered by the UTP cable with PoE and replacing the loudspeaker and
microphone of the intercom with the indicated parts. The call button of the traditional intercom is
disconnected from the old circuitry and connected directly to the module. The 2 internal relays drive
the opening of the gate, lights, or other devices. In the absence of the PoE power supply, a local
220/12V-1A both DC and AC power supply can be connected to the module.

TEMA TELECOMUNICAZIONI SRL
IP Module AA-600
MAS-AA600-REV02EN Page 12 of 56
7.3. Other application schemes
Local Speaker
20W
Internal relay
Internal Amplifier
output 2W-4 Ohm
On the occurrence of an alarm event, or found a malicious activity
through the video surveillance system, AA-600 can automatically send a
sound or prerecorded message on the speaker and call a local phone
number to alert the event with another specific message notice. The
operator can connect to AA-600 module and activate a relay to drive
other external devices (sirens, lights, ...) and to communicate in a
unidirectional manner through the speaker.
IP PBX
PoE
Switch
Barrier sensor or
alarm contact
UTP cat 5/6 cable
AA
-
600/SM5
2
Soun s an warning/ issuasion messages in vi eo surveillance systems
V
ideo surveillance
cameras
Micro
ph
o
ne
LAN/WAN
IP Network
Internal relay
operated via LA
Internal amplifier
output 2W-4 Ohm
External button
UTP cat 5/6
cable
Internal
network phones
Remote
network phones
• Bathroom an Security alarm for Hotels
• Banks an Financial Institutions
• Security in Courts, Prisons, E ucational institutions
• Safety of people an things
• Machinery Supervision
Switch
-
Router
Switch
-
Router
“SIP Security Info Call
”
Function
By connecting a button or an external
contact, AA-600 can call a phone
number programmed to alert the event
with a warning specific message. The
remote operator can acknowledge the
event and break the repetition with a
code, also can remotely activate a relay.
By connecting a speaker to AA-600 it is
possible to play a message or a pre-
recorded sound file before sending the
call.
This function is ideal in all those cases
of emergency, call for help or
information, alarm systems, vi eo
surveillance, machine controls etc. in
any geographical point of the network.
The service can be used in a "fair" way
by banks and security services with an
hidden button.
AA
-
600/SM51
Microph
o
ne
Access Control with RFID proximity rea er an keyboar
UTP cat 5/6
cable
AA
-
600/SM51
Rel
ay
2
Relay
1
PoE
Switch
RS
-
485
Bus
Access to a gate is allowed to
users that own a card or RFID
Tag enabled by the system
manager. The access can also
be made by a code typed on
the keyboard, or, for maximum
access security, by both
instruments. The second RFID
reader can be installed towards
the inside of the gate to allow
the user to exit using the card
or the Tag.
RFID 1
RFID 2

TEMA TELECOMUNICAZIONI SRL
IP Module AA-600
MAS-AA600-REV02EN Page 13 of 56
8. INSTALLATION OF THE DEVICE
8.1. CONNECTION
Here are shown the ports of the electronic module for managing the communication functions on the VoIP network
and for amplifying the audio signal. The connection of the signal cables from the field must be carried out by
qualified technical personnel, operate verifying that no cable is live, also strictly comply with the indications of the
voltage and current values for the power supplies and other parts of the system. Follow the instructions shown in
the figure for the correct electrical connection of the system.
View of the module base
with technical information
View of the accessory for fixing to
a wall or other flat surface
NOTE: an optional kit is available for fixing the AA-600 module on a DIN rail
CAM / nc / nc
1 IN1 (Input 1)
2 GND
3 K2.NA (Relay 2)
4 K2.CC
5 K1.NA (Relay 1)
6 K1.CC
7 K1.NC
8 SP1-
(2
nd
Speaker)
9 SP1+
Input for power
supply
terminals
"A" "C"
and service
voltage output
from 11 to 24Vdc
(Vout-GND)
LAN
RJ45 PoE
cable
LED and
system
Speaker
Call button and
microphone
connector
Grills on natural
ventilation openings
Connector for
camera wiring
1 2 3 4 5 6 7 8 9
C A
-
+
P1 + Mic
ETH
LAN
Keyb /Rs485/Spk.
+Led
RFID /
RS485
port
Keypad
CAUTION:
incorrect connection of
an external accessory to
a different receptacle
may result in permanent
damage to the device!

TEMA TELECOMUNICAZIONI SRL
IP Module AA-600
MAS-AA600-REV02EN Page 14 of 56
Removable 9-pole terminal block (screw connector connected to the electronic module)
1 IN1
Terminal block for the detection of the alarm contact
2 GND
Terminal block referred to the negative of the system power supply, for the alarm contact
3 K2.NA
Terminal block of the K2 relay - NO contact, normally open
4 K2.CC
Terminal block of the K2 relay - CC contact, central contact (contact load max 30V 1.5A)
5 K1.NA
Terminal block of the K1 relay - NO contact, normally open
6 K1.CC
Terminal block of the K1 relay - CC contact, central contact (contact load max 30V 1.5A)
7 K1.NC
Terminal block of the K1 relay - NC contact, normally closed
8 SP1-
Class-D amplifier 1st output terminal block for connection of a speaker, negative pole
9 SP1+
Class-D amplifier 1st output terminal block for connection of a speaker, positive pole
LAN RJ45 port (present on the electronic module)
The module needs a cable to connect to the LAN network. If the cable also carries the PoE power supply, it will not
be necessary to power the module with other power sources (for a maximum power of 10W of any added internal
audio amplifier). For higher powers an external 24Vdc 2A or max 18Vac 2.5A power supply will be required. See
also appendix 2 for LAN cable wiring at the end of the manual.
Removable 4-pole terminal block (screw connector connected to the electronic module)
C
Terminal block to power the system, irrelevant polarity
A
Terminal block to power the system, irrelevant polarity
+Vout
Terminal block from which it is possible to withdraw power supply, POSITIVE
GND
Terminal block from which it is possible to withdraw power supply, NEGATIVE
NOTE:
All the other connectors that may be present on the module sides can change function according to the models and
are linked to the specific model of installation of the purchased AD-600 module (see commercial documentation for
the models available).
Devices powered via PoE (Power over Ethernet) must only be connected with cables coming from
inside the building, LAN cable connections coming from outside the building are not allowed.
At the "+ Vout" output there is a + 12Vdc voltage if the device is powered via PoE, otherwise, on this
output the same voltage will be present on the A-C terminals. The use of "+ Vout" is permitted
provided that a maximum current consumption of 200mA is not exceeded and that the user load has
the protection on the input current. Improper use of this output will permanently damage the device.
On terminals 1 (ING1) and 2
(GND) only one relay contact or a button free of any voltage must be
connected to avoid permanent damage to the device.

TEMA TELECOMUNICAZIONI SRL
IP Module AA-600
MAS-AA600-REV02EN Page 15 of 56
9. PROGRAMMING
9.1. Preparing for programming system parameters
Programming is done via web interface. To access, simply connect an Ethernet cable from a PC or a hub to the
LAN port of AA-600.
The default IP address of AA-600 is “192.168.0.10”.
Remember that in order to successfully connect to the web interface of AA-600, it is necessary that, in the IP
addresses configuration of your PC, is present the subnet 192.168.0.x, where "x" is any number between 1 and
254 and different from 10. See below how to configure your PC to reach the correct subnet. The procedure shown
applies to Windows
®
operating system up to Windows
®
7/10.
Open the Windows Control Panel and select Network Connections, as shown below:
You must now find your connection to the LAN, choosing the one referring to the network adapter you are using to
connect with AA-600. See the following figure:

TEMA TELECOMUNICAZIONI SRL
IP Module AA-600
MAS-AA600-REV02EN Page 16 of 56
Once you find the right connection, click on it with the right mouse button and from the pull-down menu that
appears choose "Properties". Then the following window appears:
From the previous window, click "Internet Protocol (TCP / IP)" and click on "Properties". This will open the following
window where it is possible to configure the IP addresses that the network card will use:
If the PC is already on subnet 192.168.0.x with a mask 255.255.255.0, ignore the following steps. Otherwise,
proceed as follows. (The address of the PC configuration should not be 192.168.0.10).
Remember the current TCP / IP configuration of your computer for any subsequent restore of the correct
parameters.
Click "Use the following IP address" and type in the appropriate field the following IP address: 192.168.0.11
(instead of "11" used in the example it is possible to enter any number between 1 and 254, but excluding the 10
which is the default address of the door phone to be programmed). In the "Subnet Mask" enter the netmask
255.255.255.0. Click OK to confirm the changes. The PC is now ready to configure the door phone. Remember at
the end of programming to restore the network configuration of the PC to its original state if necessary.
Once you have successfully configured the IP address of your PC, it is possible to reach the Web interface to
configure AA-600.

TEMA TELECOMUNICAZIONI SRL
IP Module AA-600
MAS-AA600-REV02EN Page 17 of 56
9.2. Access to programming and reset address and password
To program the device, it is sufficient to use a standard browser such as Explorer, Firefox, Chrome or other. The
default address of the device is 192.168.0.10 with a mask of 255.255.255.0, and the user / password with which to
connect are master / master. Make sure you have access to this network segment from your computer. Once
logged in, it is possbile to change the administrative password for the maximum safety of your device, see par.
10.2.
The use is very simple and intuitive, it is always visible on the left the menu for selecting the functions to be
programmed, while on the right is shown the configuration window that is currently active. Any change will be
confirmed by pressing the "Apply" or "Save" buttons. Closing the browser or changing the page without selecting
those buttons will make lost any change.
Any changes does not require a restart of the device (except for the IP address change and the software update).

TEMA TELECOMUNICAZIONI SRL
IP Module AA-600
MAS-AA600-REV02EN Page 18 of 56
9.3. Network parameters
On this page it is possible to set the network parameters, such as IP address, netmask, etc.:
The default IP address of the device is 192.168.0.10/24. Gateway and DNS are only needed if you want the device
to have the ability to access the Internet (for example to get the current date / time, in the example from the site
time.nist.gov).
The changes to the network settings are taken over by the device until the next reboot. Once you have completed
the configuration steps so be sure to reboot the system and if necessary, change the network segment of your
computer so that it can connect to the new address.
•IP address: specify the IP address you want to assign to AA-600.
•Subnet mask: indicate the subnet mask to be assigned to AA-600.
•Default gateway: indicate the gateway that can enable AA-600 to access to internet.
•Primary and secondary DNS server: indicate the addresses of two DNS servers you want to use to resolve
IP addresses.
•Time server: indicate the address of the server you want to use for time synchronization device.
•Test address (ping): if programmed, this field contains the address used to test the network card.
•SMTP server: name or IP address of the mail server.
•Port: tcp port for the connection. Usually is 25
•User: authenticated user on the SMTP server
•Password: SMTP authentication password
•TLS connection: activate the secure connection
•Destination: email destination
•Text message: text to be included in the email sent
The button “Test Mail” can be used to test immediately if the configuration works.

TEMA TELECOMUNICAZIONI SRL
IP Module AA-600
MAS-AA600-REV02EN Page 19 of 56
9.4. SIP parameters
Once the network parameters have been set correctly, you must configure the connection with the SIP-VoIP PBX:
•SIP server address: specify the IP address of the SIP PBX to which AA-600 should connect.
•Port: is the port number of the SIP PBX AA-600 which has to forward incoming calls. Generally it is the
5060, but some stations use a different port.
•Domain: domain where register the client
•Outbound proxy: some PBXs require that the extension number to call is followed by the proxy address. In
most cases this field can be left empty.
•Local SIP port: generally the 5060 port is used, but it is possible to specify a different number (i.e. for
particular routing tables)
•User/password: credentials for the registration of the extension (which obviously must have been already
created on the PBX)
•Expiration: indicates how many seconds the device should check the correct registration of the client
•2
ND
SIP account: this account is used for “Night ringer”. It is possible to configure, in the PBX, a ringer
group used in night mode, so if the doorphone is put in the same group, it will play the ringer message
(see par. 9.14) when receiving an incoming call, without answering.
•Password: the second account password.
•Volume: volume of the ringer. It is also the volume used to reproduce the prerecorded announcements.
•Ampli on: no function in this model
•Relay 2: when the call is going on, it’s possible to activate the relay 2. It could be useful for example to
connect a light, a flash, etc.

TEMA TELECOMUNICAZIONI SRL
IP Module AA-600
MAS-AA600-REV02EN Page 20 of 56
9.5. General parameters
In this section it is possible to set parameters for general use, such as call duration, audio volume, tones, ringing
and so on:
•Calling try time: determines how long should be, in seconds, the call attempt to the extension (the called
number is ringing but not responding). At the end of the attempt, the software may be called the second
programmed number.
•Calling retry numbers: number of times that must be made the call cycle. At the end of the count of this
parameter is called a possible supervisor
•Connection time: once in connection with the extension, the call is torn down anyway after the set time.
Thirty seconds before the end of the call, the system will emit a short beep to the user within the company
and repeats the message every 5 seconds. At this stage it is possible to type on the extension phone the
sequence "#5", which forces the connection time to be reloaded.
•Answer time for incoming calls: when the system is called, it answers after the set time. If set to 0,
responds immediately, if 999 never answers. In any case, when there is an incoming call, it is possible to
answer by pressing any key.
•Connection ad communication code: when the device receives an incoming call, if this field is programmed,
the audio will not be connected until the user will enter the right connection code.
•Monitoring code: as in the previous case, for incoming calls, the audio is not connected until the code is
entered, but in this case only the audio from microphone is connected (a sort of “monitor” function, it is
possible to hear the audio near the doorphone without being heard).
•Save a snapshot of the caller: (valid only for “V” models with camera).
•Second keypress to close: it is possible to choose whether, during a call made by the visitor, a further
pressure of a key should interrupt the pressure or if it should be ignored.
•Send e-mail: it is possible to choose whether to send an email (to the address given in the configuration
page of the network). Any mail sent as an attachment will have the image of someone who has pressed the
call button.
•Calling speaker volume: sets the volume of the audio to the external user. Possible values range from 0
(very low) to 9 (very strong).
This manual suits for next models
2