Tersano SAO User manual

OFF ON
COLD WATER IN SAO SOLUTION OUT
OFF ON
COLDWATERIN SAOSOLUTION OUT
SAO Dispenser
Cartridge
122cm
48”
HEIGHT RECOMMENDATION
SAO DISPENSER
INSTALLATION GUIDE
www.tersano.com ·· 1-800-727-8835
US and International Patents and Patents Pending.
*Above diagram is a representation only
NOTE
• Tersano is not responsible for ANY damages if the Tersano unit is not installed as instructed in the steps above and/or if
water is left on to the dispenser while not in use or being attended.
• Unit to be installed vertically as shown in the picture above never horizontally. Doing so will damage the unit.
• The new hose-sets supplied with the appliance are to be used, old hose-sets should not be reused.
• Failure to follow the above installation instructions will void the warranty.
1. For correct installation, choose a location where both
the dispensing box and cartridge tube will be axed
directly over a sink or a oor drain.
2. Carefully remove all of the items from the cartons.
3. Remove mounting hardware and mounting template
from plastic packages.
4. Ax the mounting template to the wall with tape. Drill
the holes in the wall where indicated on the template.
5. Insert the #12 anchors into the 4 holes drilled for the
dispenser. Attach the dispenser to the wall using the four
#12 - 1 ½” wallmount screws in the top and bottom. Not
to be mounted on mobile devices, hand carts, etc.
6. Insert the #8 anchors into the two holes drilled for the
cartridge bracket. Attach the cartridge bracket to the wall
using the two #8 - 1 ½ “ screws.
7. Once brackets are mounted, hang the cartridge and insert
the blue desiccant lter into the front of the dispenser
until it snaps into place.
8. Facing the cartridge, attach the quick disconnect end to
the blue color tting on the bottom left side connection
of the cartridge. Attach the opposite end (the white
pressure regulator) of the hose onto the cold water supply
(3/8” hose bibb).
9. Attach connector hose (with the screen lter) supplied to
the right side outlet on the cartridge and attach opposite
end to COLD WATER IN on the dispenser (white color
ttings into grey).
10. Ensure that the water ow is at minimum 4L/minute.
This can be checked with a simple water pressure testing
gauge available at most hardware stores. NOTE: If greater
than 65 PSI, a water pressure regulator will be required.
11. Attach hose with yellow handle to SAO SOLUTION OUT
on the dispenser’s barbed tting - clamp is not required.
12. Connect only to a circuit that is protected by a
ground-fault circuit-interrupter (GFCI).
INSTALLATION INSTRUCTIONS
FOR INDOOR WALL MOUNT & DRY LOCATIONS ONLY
07/2020
Desiccant Filter
SAO SOLUTION OUT
hose
(182.88cm/72”)
FLOW OFF/ON
Switch
Performance Indicators
Service Light
SAO DISPENSERCARTRIDGE
3.8cm
1.5”
10.8cm
4.25”
35.56cm
14”
57.15cm
22.5”
15.24cm
6”
6.35mm (¼”) Drill Bit
6mm X 38mm (#12 X 1 ½”) Hex Head
4mm (⁄”) Drill Bit
4mm X 38mm (#8 X 1 ½”) Phillips Head
Install the SAO dispenser with the
cartridge 122cm (48”) from the
bottom of the dispenser to the oor.
Choose a location where both the
dispensing box and cartridge tube
will be axed directly over a sink
or a oor drain.
Pressure Regulator
COLD WATER IN
to cartridge
(attach to cold water supply)
QUICK
DISCONNECTS
COLD WATER IN
hose
(121.92cm/48”)
Screen
Filter

START-UP INSTRUCTIONS
1. Install the SAO dispenser as per INSTALLATION INSTRUCTIONS above.
2. Make sure the power cord is plugged into 120V power outlet (220V where applicable).
3. Ensure COLD WATER IN hose is attached to open faucet or permanent cold water source with a ow minimum of 4L/minute.
4. To start, press FLOW switch to ON position.
5. When SYSTEM READY indicator is GREEN, dispense into mop bucket, auto scrubber, carpet extractor or spray bottle.
6. Shut dispenser o when not in use by pressing FLOW switch to OFF position. To disconnect, ensure FLOW switch is in
OFF position before removing plug from the outlet.
7. Ensure water supply to the dispenser is turned o when not in use.
8. If you encounter a red light with initial installation you may need to turn the device on and o multiple times as it sets itself.
Once set and installed it will charge thereafter.
NOTE: If you still get a red light, check that the cold water is turned on. Check that there are no kinks in the line to allow
uninterrupted ow of water. Also check that the cartridge is in properly.
Testing was performed using a duty cycle of 5 minutes on, 25 minutes o, with a maximum 60 minutes per 24 hour periods.
Do not exceed this duty cycle.
GROUNDING INSTRUCTIONS – This appliance must be grounded. In the event of a malfunction or breakdown, grounding will
reduce the risk of electric shock by providing a path of least resistance for electric current. This appliance is equipped with a cord
having an appliance-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is
installed and grounded in accordance with all local codes and ordinances.
WARNING: Risk of Electric Shock. Disconnect power before servicing.
Never block or restrict SAO SOLUTION OUT hose with nozzle, clamp or shut-o valve. This may damage unit and will void
the warranty. Always use FLOW ON/OFF switch to start or stop ow of Stabilized Aqueous Ozone.
WARNING: Improper connection of the appliance-grounding conductor can result in a risk of electric shock. Check with a
qualied electrician or service representative if you are in doubt whether the appliance is properly grounded. Do not modify
the plug provided with the appliance; if it will not t the outlet, have a proper outlet installed by a qualied technician.
This appliance is not intended for use by children or those with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they
have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
07/2020
SAO DISPENSER
START-UP GUIDE
www.tersano.com
1-800-727-8835
US and International Patents and Patents Pending.
*Above diagram is a representation only
OFF ON
COLD WATER IN SAO SOLUTION OUT
Desiccant Filter
FLOW OFF/ON
switch
Performance Indicators
Service Light
QUICK
DISCONNECTS
SAO DISPENSERCARTRIDGE
Screen
Filter
3.8cm
1.5”
57.15cm
22.5”
10.8cm
4.25”
Pressure Regulator
COLD WATER IN
to cartridge
(attach to cold water supply)
SAO SOLUTION OUT
hose
(182.88cm/72”)
COLD WATER IN
hose
(121.92cm/48”)
Table of contents
Other Tersano Dispenser manuals
Popular Dispenser manuals by other brands

Star
Star 1-9N Installation and operation instructions

Dolphin
Dolphin Dolphin Blue BCL632F Installation and maintenance guide

ASI
ASI 0338 Installation & operation instructions

Kimberly-Clark PROFESSIONAL
Kimberly-Clark PROFESSIONAL AQUARIUS Series instructions

Simeoni
Simeoni Fertil Dispenser operating manual

lancer
lancer SERIES 1500 POSTMIX Installation and service manual