KEYPAD OPERATION INSTRUCTIONS
Temperature Control button
H: 0 without temperature.
H: 1-5 different temperature ranges.
Summer setting: H-3 \ Winter setting: H-5
Auto continuous mode
Pressing the AUTO button, then press any value, the tape
is dispensed, and the same length tape will be
automatically dispensed. Press the AUTO button again to
cancel the automatic mode.
Double length button
2X Button Doubles selected length.
For example, to dispense 30CM tape, first press the 2X
Button, then press the button 15.
Programming mode
For example, to continuously dispense
different sizes: 15-35-55CM.
First press the SET button to enter the programming mode;
Pressing the button accordingly: 15, 35, 55.
Press the ENT button to confirm and press the START
button start to dispense.
Press the SET button again to cancel the
programming mode.
Length adjustment button
Press and hold the
manual feed button
the tape is dispensed
continuously.
Plus button adds 1 cm to selected length.
Minus button subtracts 1 cm from selected length.
For example, to dispense 17CM tape, press the plus
button twice, and then press the button 15.