Texas Instruments AM437 Series User manual

Welcome to the AM437x Starter Kit (SK) Quick Start Guide. The guide is designed to help you
through the initial setup of the SK. This SK allows you to experience Linux™ and other operating
systems on the AM437x Cortex®-A9 processor, 3D graphics and more. The AM437x SK contains
the following:
Hardware
• Sitara™ AM437x Cortex-A9 processor,
up to 1 GHz
• TPS65218 power management I/C
• 4.3"capacitivetouchLCD
• 1GBDDR3L
• Onecameramodule
• On-boardQSPI-NORFlash
• 2-portGbEthernetswitch
Printed Documents
• AM437xSKQuickStartGuide(this
document)
Miscellaneous
• Powersupplywithinternationaladapters
• µSDcardwithLinux
• µSD-to-SDcardadapter
• MicroUSB2.0cable
1
3
2
User LEDs
Menu
Home
Back
Search
+5V supply
Audio Out
Audio In GIGETH1
RESET
PWR ON
PMIC
µSD
USB 2.0
µUSB 2.0 µUSB 2.0
GIGETH2
WiLink8 Connector
AM4378

Default setup (OS boot from µSD card)
RemovetheLCDprotectiveplastic.
1
Connectthepowercabletothepowerjackon
theboardandplugintoanACpowersource.
Note: When powering the board, always use the supplied power
supply (WT Part Number WT24-0502500-U) or equivalent
model having output voltage of +5VDC and output current max
3.0 Amp as well as the applicable regional product regulatory/
safety certification requirements such as (by example) UL, CSA,
VDE, CCC, PSE, etc.
3
InserttheLinuxµSDcardintotheAM437x
Starter Kit as shown.
2

You are now ready to explore the Linux demos. Click on any icon to start the demo and click “exit”
(ifavailable)toquitthedemo.
5
6
Push and hold thepowerbuttonuntilthe
board’spowerLEDisilluminated.
Toturnoff,holdthepowerbuttonfor
10secondsoruntilpowerLEDturnsoff.
4
7

Begin development
Toprepareyourworkstationforsoftwaredevelopment,poweroffthekit,removetheµSDcard,
insertintotheincludedSDcardadapter(ifapplicable)andinsertitintoyourPC.IfyourPCdoesnot
includeanSDslot,USBSDcardadaptersarereadilyavailable.Followtheinstructionsbelow.
Linux™Development:FromaLinuxhostPC,
insert the Linux SD card into the PC, and locate
the START HERE folder. Run setup.htm.
If you need help on setting up a Linux Host PC,
pleasevisitwww.ti.com/startyourlinux.
6
ConnectthesuppliedUSBcabletothe
microUSBconnectorontheAM437xbase-
boardandplugtheotherendtoyourPC.
7

ConnectanEthernetCable(notincluded)
totheRJ-45jackontheAM437xSKboard
as shown.
8

FormoreinformationonAM437xprocessors,including:
• UserGuide • Software
• HowTos • DesignFiles
pleasevisitwww.ti.com/am437x and www.ti.com/am437xsk
Forsupportquestions,pleasecontact:[email protected] or www.ti.com/e2e.
Provide feedback:TakethissurveyandtellusaboutyourexperienceusingtheAM437xStarter
Kit: www.ti.com/survey
Important Notice:
TheproductsandservicesofTexasinstrumentsIncorporatedanditssubsidiariesdescribedherein
aresoldsubjecttoTI’sstandardtermsandconditionsofsale.Customersareadvisedtoobtain
themostcurrentandcompleteinformationaboutTIproductsandservicesbeforeplacingorders.
TIassumesnoliabilityforapplicationsassistance,customer’sapplicationsorproductdesigns,
softwareperformance,orinfringementofpatents.Thepublicationofinformationregardinganyother
company’sproductsorservicesdoesnotconstituteTI’sapproval,warrantyorendorsementthereof.
Trademarks in this issue:TheplatformbarandSitaraaretrademarksofTexasInstruments.
Allothertrademarksarethepropertyoftheirrespectiveowners.
Additional resources

SPRW270
Thank you
for purchasing this Texas Instruments
SimpleLink™Wi-Fi®CC3000 Evaluation
Module
To get started, and for questions, please visit:
Wireless Connectivity Wiki: www.ti.com/cc3000wiki
User guides, sample applications, software available
E2E Forum: www.ti.com/cc3000forum
Engineer-to-engineer technical support
EVALUATION BOARD/KIT/MODULE (EVM) WARNINGS, RESTRICTIONS AND DISCLAIMERS
For Feasibility Evaluation Only, in Laboratory/Development Environments. Unless otherwise indicated, this EVM is not a fin-
ished electrical equipment and not intended for consumer use. It is intended solely for use for preliminary feasibility evaluation in
laboratory/development environments by technically qualified electronics experts who are familiar with the dangers and application
risks associated with handling electrical mechanical components, systems and subsystems. It should not be used as all or part of a
finished end product
Your Sole Responsibility and Risk. You acknowledge, represent and agree that:
1. You have unique knowledge concerning Federal, State and local regulatory requirements (including but not limited to Food and
Drug Administration regulations, if applicable) which relate to your products and which relate to your use (and/or that of your
employees, affiliates, contractors or designees) of the EVM for evaluation, testing and other purposes.
2. You have full and exclusive responsibility to assure the safety and compliance of your products with all such laws and other ap-
plicable regulatory requirements, and also to assure the safety of any activities to be conducted by you and/or your employees,
affiliates, contractors or designees, using the EVM. Further, you are responsible to assure that any interfaces (electronic and/or
mechanical) between the EVM and any human body are designed with suitable isolation and means to safely limit accessible
leakage currents to minimize the risk of electrical shock hazard.
3. You will employ reasonable safeguards to ensure that your use of the EVM will not result in any property damage, injury or death,
even if the EVM should fail to perform as described or expected.
4. You will take care of proper disposal and recycling of the EVM’s electronic components and packing materials.
Certain Instructions. It is important to operate this EVM within TI’s recommended specifications and environmental considerations
per the user guidelines. Exceeding the specified EVM ratings (including but not limited to input and output voltage, current, power, and
environmental ranges) may cause property damage, personal injury or death. If there are questions concerning these ratings please
contact a TI field representative prior to connecting interface electronics including input power and intended loads. Any loads applied
outside of the specified output range may result in unintended and/or inaccurate operation and/or possible permanent damage to
the EVM and/or interface electronics. Please consult the EVM User’s Guide prior to connecting any load to the EVM output. If there is
uncertainty as to the load specification, please contact a TI field representative. During normal operation, some circuit components may
have case temperatures greater than 60oC as long as the input and output are maintained at a normal ambient operating temperature.
These components include but are not limited to linear regulators, switching transistors, pass transistors, and current sense resistors
which can be identified using the EVM schematic located in the EVM User’s Guide. When placing measurement probes near these
devices during normal operation, please be aware that these devices may be very warm to the touch. As with all electronic evaluation
tools, only qualified personnel knowledgeable in electronic measurement and diagnostics normally found in development environments
should use these EVMs
Agreement to Defend, Indemnify and Hold Harmless. You agree to defend, indemnify and hold TI, its licensors and their represen-
tatives harmless from and against any and all claims, damages, losses, expenses, costs and liabilities (collectively, “Claims”) arising out
of or in connection with any use of the EVM that is not in accordance with the terms of the agreement. This obligation shall apply wheth-
er Claims arise under law of tort or contract or any other legal theory, and even if the EVM fails to perform as described or expected.
Safety-Critical or Life-Critical Applications. If you intend to evaluate the components for possible use in safety critical applications
(such as life support) where a failure of the TI product would reasonably be expected to cause severe personal injury or death, such as
devices which are classified as FDA Class III or similar classification, then you must specifically notify TI of such intent and enter into a
separate Assurance and Indemnity Agreement.
The platform bar is a trademark of Texas Instruments. © 2012 Texas Instruments Incorporated. 9Printed on recycled paper SZZZ078
TI Worldwide Technical Support
INTERNET
TI Semiconductor Product Information Center Home Page
www.support.ti.com
TI Semiconductor Knowledge Base Home Page
www.support.ti.com/sc/knowledgebase
PRODUCT INFORMATION CENTERS
Americas
Phone +1 (972) 644-5580
Brazil
Phone 0800-891-2616
Mexico
Phone 0800-670-7544
Fax +1 (972) 927-6377
Internet/Email
www.ti.com/ww/en/pic/PIC-Americas.htm
Europe, Middle East, and Africa
Phone
European Free Call 00800-ASK TEXAS
(00800 275 83927)
International +49 (0) 8161 80 2121
Russian Support +7 (4) 95 98 10 701
NOTE: The European Free Call (Toll Free) number is not
active in all countries. If you have technical difficulty
calling the free call number please use the international
number above.
Fax +(49) (0) 8161 80 2045
Internet
www.ti.com/ww/eu/customer_support/index.htm
Asia
Phone
International +91-80-41381665
Domestic Toll Free Number
Australia 1-800-999-084
China 800-820-8682
Hong Kong 800-96-5941
India 1-800-425-7888
Korea 080-551-2804
Malaysia 1-800-80-3973
New Zealand 0800-446-934
Philippines 1-800-765-7404
Singapore 800-886-1028
Taiwan 0800-006800
Thailand 001-800-886-0010
Fax +886-2-2378-6808
Email [email protected]
Internetwww.ti.com/ww/en/pic/PIC-Asia.html
Japan
Fax
International +81-3-3344-5317
Domestic 0120-81-0036
Internet/Email
International
www.ti.com/ww/en/pic/PIC- Japan.html
Domestic www.tij.co.jp/pic
© 2015 Texas Instruments Incorporated.
Printed on recycled paper.
Internet www.ti.com/ww/en/pic/PIC-Asia.html

IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, enhancements, improvements and other
changes to its semiconductor products and services per JESD46, latest issue, and to discontinue any product or service per JESD48, latest
issue. Buyers should obtain the latest relevant information before placing orders and should verify that such information is current and
complete. All semiconductor products (also referred to herein as “components”) are sold subject to TI’s terms and conditions of sale
supplied at the time of order acknowledgment.
TI warrants performance of its components to the specifications applicable at the time of sale, in accordance with the warranty in TI’s terms
and conditions of sale of semiconductor products. Testing and other quality control techniques are used to the extent TI deems necessary
to support this warranty. Except where mandated by applicable law, testing of all parameters of each component is not necessarily
performed.
TI assumes no liability for applications assistance or the design of Buyers’ products. Buyers are responsible for their products and
applications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provide
adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or
other intellectual property right relating to any combination, machine, or process in which TI components or services are used. Information
published by TI regarding third-party products or services does not constitute a license to use such products or services or a warranty or
endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the
third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of significant portions of TI information in TI data books or data sheets is permissible only if reproduction is without alteration
and is accompanied by all associated warranties, conditions, limitations, and notices. TI is not responsible or liable for such altered
documentation. Information of third parties may be subject to additional restrictions.
Resale of TI components or services with statements different from or beyond the parameters stated by TI for that component or service
voids all express and any implied warranties for the associated TI component or service and is an unfair and deceptive business practice.
TI is not responsible or liable for any such statements.
Buyer acknowledges and agrees that it is solely responsible for compliance with all legal, regulatory and safety-related requirements
concerning its products, and any use of TI components in its applications, notwithstanding any applications-related information or support
that may be provided by TI. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards which
anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause
harm and take appropriate remedial actions. Buyer will fully indemnify TI and its representatives against any damages arising out of the use
of any TI components in safety-critical applications.
In some cases, TI components may be promoted specifically to facilitate safety-related applications. With such components, TI’s goal is to
help enable customers to design and create their own end-product solutions that meet applicable functional safety standards and
requirements. Nonetheless, such components are subject to these terms.
No TI components are authorized for use in FDA Class III (or similar life-critical medical equipment) unless authorized officers of the parties
have executed a special agreement specifically governing such use.
Only those TI components which TI has specifically designated as military grade or “enhanced plastic” are designed and intended for use in
military/aerospace applications or environments. Buyer acknowledges and agrees that any military or aerospace use of TI components
which have not been so designated is solely at the Buyer's risk, and that Buyer is solely responsible for compliance with all legal and
regulatory requirements in connection with such use.
TI has specifically designated certain components as meeting ISO/TS16949 requirements, mainly for automotive use. In any case of use of
non-designated products, TI will not be responsible for any failure to meet ISO/TS16949.
Products Applications
Audio www.ti.com/audio Automotive and Transportation www.ti.com/automotive
Amplifiers amplifier.ti.com Communications and Telecom www.ti.com/communications
Data Converters dataconverter.ti.com Computers and Peripherals www.ti.com/computers
DLP® Products www.dlp.com Consumer Electronics www.ti.com/consumer-apps
DSP dsp.ti.com Energy and Lighting www.ti.com/energy
Clocks and Timers www.ti.com/clocks Industrial www.ti.com/industrial
Interface interface.ti.com Medical www.ti.com/medical
Logic logic.ti.com Security www.ti.com/security
Power Mgmt power.ti.com Space, Avionics and Defense www.ti.com/space-avionics-defense
Microcontrollers microcontroller.ti.com Video and Imaging www.ti.com/video
RFID www.ti-rfid.com
OMAP Applications Processors www.ti.com/omap TI E2E Community e2e.ti.com
Wireless Connectivity www.ti.com/wirelessconnectivity
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2015, Texas Instruments Incorporated
Table of contents
Popular Touch Panel manuals by other brands

Beckhoff
Beckhoff CP6201 Installation and operating instructions

Rotronic
Rotronic HygroPalm AW1 instruction manual

Balboa
Balboa ML200 Quick reference guide

Lenze
Lenze EL 103 ECO PLC operating instructions

AMX
AMX PTM-D15 instruction manual

Clare Controls
Clare Controls ClareHome Touch Panel quick start guide

Beijer Electronics
Beijer Electronics iX T15C - C23 installation manual

DFI
DFI TPC150 Quick manual

SuperLogics
SuperLogics PPC-360 user manual

Beckhoff
Beckhoff CP27 Series Installation and operating instructions

MicroTouch
MicroTouch Profile installation guide

GE Security
GE Security 60-597 installation instructions