ABB SmartTouch i-bus KNX User manual

Product manual │01.08.2022
ABB i-bus®KNX / ABB-free@home®
STU10.x.11
ABB SmartTouch®
Branding -- Releas e 2018-01-01

Table of contents
Product manual 2CKA00xx73xxxxx
│
2
Table of contents
1
Notes on the instruction manual..................................................................................................................13
2
Safety...........................................................................................................................................................14
2.1
Information and symbols used.........................................................................................................14
2.2
Intended use ....................................................................................................................................15
2.3
Improper use ....................................................................................................................................15
2.4
Target group / Qualifications of personnel.......................................................................................16
2.4.1
Operation ................................................................................................................................... 16
2.4.2
Installation, commissioning and maintenance ............................................................................ 16
2.5
Cyber security ..................................................................................................................................17
2.5.1
Ports and services for supporting the main functionality............................................................. 19
2.6
Safety instructions............................................................................................................................21
3
Information on protection of the environment .............................................................................................22
3.1
Environment .....................................................................................................................................22
4
Product Overview ........................................................................................................................................23
4.1
Scope of supply................................................................................................................................25
4.2
Additional necessary components ...................................................................................................25
4.3
Overview of types.............................................................................................................................25
4.4
Overview of KNX functions ..............................................................................................................26
4.5
Device overview ...............................................................................................................................26
5
Technical data .............................................................................................................................................28
5.1
Dimensional drawings......................................................................................................................29
5.2
Circuit diagrams ...............................................................................................................................30
6
Connection, installation / mounting .............................................................................................................31
6.1
Planning instructions ........................................................................................................................31
6.2
Safety instructions............................................................................................................................31
6.3
Requirements for the electrician ......................................................................................................31
6.4
Preparatory steps.............................................................................................................................32
6.5
Mounting / dismantling .....................................................................................................................33
6.5.1
Installation sites.......................................................................................................................... 33
6.5.2
Mounting .................................................................................................................................... 34
6.5.3
Mounting in flush-mounted installation box in solid wall ............................................................. 35
6.5.4
Mounting in flush-mounted installation box in hollow wall........................................................... 36
6.5.5
Mounting with surface-mounted mounting frame........................................................................ 37
6.6
Electrical connection ........................................................................................................................38
6.6.1
Connection, installation and addressing ..................................................................................... 38
6.6.2
External power supply ................................................................................................................ 39
6.6.3
Installation .................................................................................................................................. 39
6.7
Dismantling.......................................................................................................................................40
7
Initial commissioning of device....................................................................................................................41
7.1
Initial commissioning with ABB-free@home
®
..................................................................................43

Table of contents
Product manual 2CKA00xx73xxxxx
│
3
8
Commissioning of the KNX Function via DCA (from ETS5) .......................................................................46
8.1
Integration into the KNX system (ETS)............................................................................................46
8.1.1
Prerequisites .............................................................................................................................. 46
8.1.2
Installation of the Busch-SmartTouch
®
ETS Touch DCA App .................................................... 47
8.1.3
Installation sequence.................................................................................................................. 48
8.1.4
Integrating the ABB SmartTouch
®
into the ETS.......................................................................... 49
8.2
Overview of the DCA commissioning tool .......................................................................................50
8.2.1
Starting the DCA ........................................................................................................................ 50
8.3
Screen areas of the DCA .................................................................................................................51
8.4
Explanation of the basic structure (Terms)......................................................................................53
8.5
Commissioning sequence................................................................................................................55
8.6
Configuring basic settings for the panel ..........................................................................................55
8.6.1
Basic settings (system settings) of the panel.............................................................................. 56
8.7
Creating the navigation structure.....................................................................................................70
8.7.1
Creating operating pages (start pages) ...................................................................................... 70
8.7.2
Creating room and floor pages ................................................................................................... 71
8.7.3
Editing operating pages.............................................................................................................. 71
8.8
Configuration of the operating pages...............................................................................................73
8.8.1
"Switch" control element............................................................................................................. 74
8.8.2
Control element "Rocker switch" ................................................................................................ 74
8.8.3
"Dimmer" control element........................................................................................................... 74
8.8.4
Control element: "Dimmer slider" ............................................................................................... 74
8.8.5
Operation of "RGBW" control element“ ...................................................................................... 74
8.8.6
"Blind" control element ............................................................................................................... 75
8.8.7
Control element "RTC control element"...................................................................................... 75
8.8.8
Control element "Fan switch" ..................................................................................................... 75
8.8.9
Control element "Split Unit Control"............................................................................................ 75
8.8.10
Control element "VRV control" ................................................................................................... 75
8.8.11
"Scene" control element ............................................................................................................. 76
8.8.12
Control element: "Value slider"................................................................................................... 76
8.8.13
"Display" control element ........................................................................................................... 76
8.8.14
Control element "Audio control".................................................................................................. 76
8.8.15
"Page link" control element......................................................................................................... 76
8.8.16
Control element "Welcome control"............................................................................................ 77
8.9
Editing control elements...................................................................................................................78
8.9.1
Delete control element ............................................................................................................... 78
8.9.2
Copy control element ................................................................................................................. 79
8.9.3
Add control element to favourites list.......................................................................................... 79
8.10
Configuration of applications and application pages .......................................................................80
8.10.1
Application "Door communication" ............................................................................................. 80
8.10.2
Application "Fault and alarm messages" .................................................................................... 81
8.10.3
Application "Scene actuator" ...................................................................................................... 82
8.10.4
Application "Presence simulation" .............................................................................................. 82
8.10.5
Application "Time programs" ...................................................................................................... 83
8.10.6
Application "Logical functions".................................................................................................... 83
8.10.7
Application "Internal RTC".......................................................................................................... 84
8.10.8
"Favourite control elements"....................................................................................................... 84
8.11
Editing communication objects ........................................................................................................86
8.12
Editing group addresses ..................................................................................................................87

Table of contents
Product manual 2CKA00xx73xxxxx
│
4
8.13
Additional tools (functions)...............................................................................................................88
8.13.1
Import......................................................................................................................................... 88
8.13.2
Export......................................................................................................................................... 89
8.13.3
Preview ...................................................................................................................................... 89
8.13.4
Reset layout ............................................................................................................................... 89
8.13.5
Reset all ..................................................................................................................................... 89
9
Commissioning via ABB-free@home
®
........................................................................................................90
9.1
Allocation of devices and definition of channels ..............................................................................90
9.1.1
Add device ................................................................................................................................. 91
9.2
Setting options per channel .............................................................................................................93
9.2.1
Parameter settings of panel........................................................................................................ 94
9.2.1.1
Parameter settings Channel........................................................................ 97
9.2.1.2
Other settings.............................................................................................. 99
9.3
Specifying or editing functions (buttons)........................................................................................101
9.3.1
Creating functions .....................................................................................................................101
9.3.2
Changing functions....................................................................................................................104
9.3.3
Removing functions...................................................................................................................105
10
KNX control elements and application parameters...................................................................................106
10.1
"Switch" control element ................................................................................................................106
10.1.1
Name of the control element .....................................................................................................106
10.1.2
Size of the button ......................................................................................................................106
10.1.3
Type of switch ...........................................................................................................................106
10.1.4
Object type 1 / value 2...............................................................................................................107
10.1.5
Status control element (icon/text) is operated via a separate object..........................................110
10.1.6
Icon type....................................................................................................................................110
10.1.7
Enable 1-bit communication object "Disable" ............................................................................112
10.2
Control element "Rocker switch" ...................................................................................................113
10.2.1
Name of the control element .....................................................................................................113
10.2.2
Function of the control element .................................................................................................113
10.2.3
Size of the button ......................................................................................................................113
10.2.4
Icon type....................................................................................................................................113
10.2.5
Status control element (icon/text) is operated via a separate object..........................................114
10.2.6
Object type ................................................................................................................................115
10.2.7
Enable 1-bit communication object "Disable" ............................................................................118
10.3
"Dimmer" control element ..............................................................................................................119
10.3.1
Name of the control element .....................................................................................................119
10.3.2
Function of the control element .................................................................................................119
10.3.3
Size of the button ......................................................................................................................119
10.3.4
Icon type....................................................................................................................................119
10.3.5
Icon for On / icon for Off ............................................................................................................120
10.3.6
Position for dim up icon .............................................................................................................120
10.3.7
Icon for dimming up / icon for dimming down ............................................................................120
10.3.8
Status control element (icon) is operated via a separate object ................................................120
10.3.9
Status of dimming value is controlled by a separate object .......................................................120
10.3.10
Manner of dimming....................................................................................................................121
10.3.11
Enable 1-bit communication object "Disable" ............................................................................122
10.4
Control element: "Dimmer slider"...................................................................................................123
10.4.1
Name of the control element .....................................................................................................123

Table of contents
Product manual 2CKA00xx73xxxxx
│
5
10.4.2
Function of the control element .................................................................................................123
10.4.3
Size of the button ......................................................................................................................123
10.4.4
Icon type....................................................................................................................................123
10.4.5
Icon for On / icon for Off ............................................................................................................124
10.4.6
Status control element (icon) is operated via a separate object ................................................124
10.4.7
Display value in control element................................................................................................125
10.4.8
Slider sends ..............................................................................................................................126
10.4.9
Brightness change [%] ..............................................................................................................126
10.4.10
Enable 1-bit communication object "Disable" ............................................................................126
10.5
Operation of "RGBW" control element“ .........................................................................................127
10.5.1
Name of the control element .....................................................................................................127
10.5.2
Function of the control element .................................................................................................127
10.5.3
Display value in control element................................................................................................127
10.5.4
Type of colour/white lamp .........................................................................................................127
10.5.5
Brightness change [%] ..............................................................................................................130
10.5.6
Telegram is repeated every [sec.]: ............................................................................................130
10.5.7
Enable 1-bit communication object "Disable" ............................................................................130
10.6
"Blind" control element ...................................................................................................................131
10.6.1
Name of the control element .....................................................................................................131
10.6.2
Function of the control element .................................................................................................131
10.6.3
Size of the button ......................................................................................................................131
10.6.4
Type of control ..........................................................................................................................131
10.6.5
Icon type....................................................................................................................................132
10.6.6
Status control element (icon) is operated via a separate object ................................................133
10.6.7
Enable 1-bit communication object "Disable" ............................................................................134
10.7
Control element "RTC control element".........................................................................................135
10.7.1
Name of the control element .....................................................................................................135
10.7.2
Function of the control element .................................................................................................135
10.7.3
Additional functions/objects.......................................................................................................135
10.7.4
Delay time during reading of telegrams after reset [sec.]...........................................................135
10.7.5
Input for temperature reading ....................................................................................................136
10.7.6
Display actual temperature........................................................................................................136
10.7.7
Unit of temperature....................................................................................................................136
10.7.8
Set value is relative ...................................................................................................................137
10.7.9
Heating/cooling switchover........................................................................................................138
10.7.10
Fan coil control during heating mode ........................................................................................138
10.7.11
Fan coil control during cooling mode.........................................................................................138
10.7.12
Setting the temperature unit via object ......................................................................................138
10.7.13
Enable 1-bit communication object "Disable" ............................................................................138
10.8
Control element "Fan switch".........................................................................................................139
10.8.1
Name of the control element .....................................................................................................139
10.8.2
Function of the control element .................................................................................................139
10.8.3
Size of the button ......................................................................................................................139
10.8.4
Deactivation of switch-off option................................................................................................139
10.8.5
Icon type....................................................................................................................................140
10.8.6
Telegram is repeated every [sec.]: ............................................................................................140
10.8.7
Number of levels .......................................................................................................................141
10.8.8
Object type ................................................................................................................................141
10.8.9
Display status............................................................................................................................143
10.8.10
Enable 1-bit communication object "Disable" ............................................................................144
10.9
Control "Split Unit Control".............................................................................................................145

Table of contents
Product manual 2CKA00xx73xxxxx
│
6
10.9.1
Name of the control element .....................................................................................................145
10.9.2
Name of room (otional)..............................................................................................................145
10.9.3
Size of the button ......................................................................................................................145
10.9.4
Function icon.............................................................................................................................145
10.9.5
Display actual temperature........................................................................................................145
10.9.6
Minimum setpoint ......................................................................................................................146
10.9.7
Maximum setpoint .....................................................................................................................146
10.9.8
Step size of setpoint adjustment................................................................................................146
10.9.9
Number of fan speed levels (without AUTO) .............................................................................146
10.9.10
Use automatic mode for fans.....................................................................................................146
10.9.11
Use mode: Automatic ................................................................................................................146
10.9.12
Use mode: Heating....................................................................................................................147
10.9.13
Use mode: Cooling....................................................................................................................147
10.9.14
Use mode: Drying......................................................................................................................147
10.9.15
Use mode: Fan..........................................................................................................................147
10.9.16
Use horizontal oscillation...........................................................................................................147
10.9.17
Use vertical oscillation...............................................................................................................147
10.9.18
Use extra mode: Silence Mode .................................................................................................148
10.9.19
Use additional mode: Boost ......................................................................................................148
10.9.20
Use additional mode: Forced operation.....................................................................................148
10.9.21
Use additional mode: Scene......................................................................................................148
10.9.22
Additional mode Use window contact........................................................................................149
10.9.23
Use additional Presence mode..................................................................................................149
10.9.24
Enable 1-bit communication object "Disable" ............................................................................149
10.10
Control "Split Unit Control".............................................................................................................150
10.10.1
Name of the control element .....................................................................................................150
10.10.2
Name of room (otional)..............................................................................................................150
10.10.3
Size of the button ......................................................................................................................150
10.10.4
Function icon.............................................................................................................................150
10.10.5
Value [1 byte 0-255] for heating mode.......................................................................................151
10.10.6
Value [1 byte 0-255] for cooling mode.......................................................................................151
10.10.7
Using fan operation ...................................................................................................................151
10.10.8
Value [1 byte 0-255] for fan operation .......................................................................................151
10.10.9
Using dehumidification operation ..............................................................................................151
10.10.10
Value [1 byte 0-255] for dehumidification operation...................................................................151
10.10.11
Using automatic operation.........................................................................................................151
10.10.12
Value [1 byte 0-255] for automatic operation.............................................................................152
10.10.13
Fan speed levels .......................................................................................................................153
10.10.14
Value for the speed x ................................................................................................................153
10.10.15
Using automatic fan speed control ............................................................................................153
10.10.16
Value for automatic fan speed x ................................................................................................153
10.10.17
Step size ...................................................................................................................................154
10.10.18
Maximum setpoint [°C] ..............................................................................................................154
10.10.19
Minimum setpoint [°C] ...............................................................................................................154
10.10.20
Using VRV temperature sensor error display ............................................................................155
10.10.21
Using VRV error display ............................................................................................................155
10.10.22
Value for cancelling the VRV error display ................................................................................155
10.10.23
Enable 1-bit communication object "Disable" ............................................................................155
10.11
"Scene" control element.................................................................................................................156
10.11.1
Name of the control element .....................................................................................................156
10.11.2
Function of the control element .................................................................................................156

Table of contents
Product manual 2CKA00xx73xxxxx
│
7
10.11.3
Start scene at selection .............................................................................................................156
10.11.4
Long operation after... ...............................................................................................................156
10.11.5
Number of scenes [1 - 10] .........................................................................................................156
10.11.6
Scene number x [1 - 64] ............................................................................................................157
10.11.7
Name of scene x .......................................................................................................................157
10.11.8
Saving scene x with a long press ..............................................................................................157
10.11.9
Enable 1-bit communication object "Disable" ............................................................................157
10.12
Control element: "Value slider" ......................................................................................................158
10.12.1
Name of the control element .....................................................................................................158
10.12.2
Function of the control element .................................................................................................158
10.12.3
Size of the button ......................................................................................................................158
10.12.4
Slider from.................................................................................................................................158
10.12.5
Display value in control element................................................................................................159
10.12.6
Slider sends ..............................................................................................................................159
10.12.7
Object type ................................................................................................................................160
10.12.8
Enable 1-bit communication object "Disable" ............................................................................161
10.13
"Display" control element ...............................................................................................................162
10.13.1
Name of the control element .....................................................................................................162
10.13.2
Function of the control element .................................................................................................162
10.13.3
Type of display element ............................................................................................................162
10.13.4
Type of display element — Status display — Size of the button................................................163
10.13.5
Type of display element — Status display — Object type .........................................................163
10.13.6
Type of display element — Value display — Size of the button.................................................164
10.13.7
Type of display element — Value display — Object type ..........................................................164
10.13.8
Type of display element — Linear measurement display — Measurement display with
colour display ............................................................................................................................166
10.13.9
Type of display element — Linear measurement display — Display value in control
element .....................................................................................................................................166
10.13.10
Type of display element — Linear measurement display — Object type...................................168
10.13.11
Type of display element — Round measurement display..........................................................169
10.13.12
Type of display element — Wind rose.......................................................................................170
10.13.13
Type of display element — Wind force — Size of the button.....................................................170
10.13.14
Type of display element — Wind force — Unit ..........................................................................171
10.13.15
Type of display element — Temperature — Size of the button .................................................171
10.13.16
Type of display element — Temperature — Unit.......................................................................171
10.13.17
Type of display element — Rain — Size of the button ..............................................................171
10.13.18
Type of display element — Rain — Text for rain .......................................................................171
10.13.19
Type of display element — Rain — Text for no rain ..................................................................171
10.13.20
Type of display element — Twilight — Size of the button..........................................................172
10.13.21
Type of display element — Twilight — Unit ...............................................................................172
10.13.22
Type of display element — Brightness ......................................................................................172
10.13.23
Type of display element — CO
2
— Size of the button ...............................................................172
10.13.24
Type of display element — CO
2
— Unit ....................................................................................172
10.13.25
Type of display element — Moisture — Size of the button ........................................................172
10.13.26
Type of display element — Moisture — Unit .............................................................................173
10.13.27
Type of display element — Air pressure — Size of the button...................................................173
10.13.28
Type of display element — Air pressure — Unit........................................................................173
10.13.29
Enable 1-bit communication object "Disable" ............................................................................173
10.14
Control element "Audio control" .....................................................................................................174
10.14.1
Name of the control element .....................................................................................................174
10.14.2
Function of the control element .................................................................................................174
10.14.3
Number of sources ....................................................................................................................174

Table of contents
Product manual 2CKA00xx73xxxxx
│
8
10.14.4
Use of play button .....................................................................................................................175
10.14.5
Use of pause button ..................................................................................................................175
10.14.6
Use of stop button .....................................................................................................................176
10.14.7
Use of forward button ................................................................................................................176
10.14.8
Use of return key.......................................................................................................................177
10.14.9
Use of button for mute...............................................................................................................178
10.14.10
Use of volume button ................................................................................................................179
10.14.11
Use of ON/OFF button ..............................................................................................................180
10.14.12
Enable 1-bit communication object "Disable" ............................................................................180
10.15
"Page link" control element ............................................................................................................181
10.15.1
Name of the control element .....................................................................................................181
10.15.2
Function of the control element .................................................................................................181
10.15.3
Size of the button ......................................................................................................................181
10.15.4
Linked with page .......................................................................................................................181
10.15.5
Enable 1-bit communication object "Disable" ............................................................................182
10.16
Control element "Audio control" .....................................................................................................183
10.16.1
Name of the control element .....................................................................................................183
10.16.2
Name of room (otional)..............................................................................................................183
10.16.3
Size of the button ......................................................................................................................183
10.16.4
Function icon.............................................................................................................................183
10.16.5
Type of the control element.......................................................................................................183
10.16.6
Using trigger object ...................................................................................................................183
10.16.7
Trigger with ...............................................................................................................................184
10.16.8
Enable 1-bit communication object "Disable" ............................................................................184
10.17
Application "Door communication".................................................................................................185
10.17.1
Use of door communication.......................................................................................................185
10.17.2
Page PIN-protected...................................................................................................................185
10.17.3
Ring tone volume preset [%] .....................................................................................................185
10.17.4
Speech volume preset [%] ........................................................................................................186
10.18
Application "Fault and alarm messages" - Global settings............................................................187
10.18.1
Use of fault and alarm messages ..............................................................................................187
10.18.2
Page PIN-protected...................................................................................................................187
10.18.3
Enable export ............................................................................................................................188
10.18.4
Automatic archiving at an acknowledgement ............................................................................188
10.18.5
Sound for alarm.........................................................................................................................188
10.18.6
Sound for Notice .......................................................................................................................188
10.18.7
Signal tone for error...................................................................................................................189
10.18.8
Default setting for signal tone volume [%] .................................................................................189
10.19
Application "Fault and alarm messages" - Settings of the individual messages...........................190
10.19.1
Name of message .....................................................................................................................190
10.19.2
Type of message.......................................................................................................................190
10.19.3
Type of alarm ............................................................................................................................190
10.20
Application "Scene actuator"..........................................................................................................192
10.20.1
Name of scene actuator ............................................................................................................192
10.20.2
Number of participants ..............................................................................................................192
10.20.3
Number of scenes .....................................................................................................................192
10.20.4
Overwriting scenes during download.........................................................................................192
10.20.5
Telegram delay .........................................................................................................................192
10.20.6
Object type x .............................................................................................................................193
10.20.7
Name of scene ..........................................................................................................................196

Table of contents
Product manual 2CKA00xx73xxxxx
│
9
10.20.8
Scene number...........................................................................................................................196
10.20.9
Light scenes can be started with ...............................................................................................196
10.20.10
Light scene can be stored .........................................................................................................196
10.20.11
Object x is to be changed..........................................................................................................196
10.21
Application "Presence simulation" .................................................................................................197
10.21.1
Use of presence simulation .......................................................................................................197
10.21.2
Page PIN-protected...................................................................................................................197
10.21.3
Enable export ............................................................................................................................197
10.21.4
Delay time up to activation [min.]...............................................................................................198
10.21.5
Object type 1-20........................................................................................................................198
10.22
Application "Time programs"..........................................................................................................199
10.22.1
Page PIN-protected...................................................................................................................199
10.22.2
Overwriting time programs during download .............................................................................199
10.23
Application "Logical functions" .......................................................................................................200
10.23.1
Channel x — Application ...........................................................................................................200
10.24
Application "Internal RTC" .............................................................................................................211
10.24.1
General — Device function .......................................................................................................211
10.24.2
General — Control function.......................................................................................................211
10.24.3
General - Operating mode after reset........................................................................................212
10.24.4
General — Send cyclic "In operation" (min) ..............................................................................213
10.24.5
General - Additional functions/objects .......................................................................................213
10.24.6
General — Delay time for read telegrams after reset [s]............................................................213
10.24.7
Heating control — Control value type........................................................................................214
10.24.8
Heating control — Heating type.................................................................................................215
10.24.9
Heating control — P-component (x 0.1°C) ................................................................................215
10.24.10
Heating control — I-component (min.).......................................................................................216
10.24.11
Heating control — Extended settings ........................................................................................216
10.24.12
Basic stage heating ...................................................................................................................216
10.24.13
Basic stage heating — Status object heating ............................................................................216
10.24.14
Basic stage heating — Mode of the control value......................................................................216
10.24.15
Basic stage heating — Hysteresis (x 0.1°C)..............................................................................217
10.24.16
Basic stage heating — Control value difference for sending of heating control value................217
10.24.17
Basic stage heating — Cyclic sending of the control value (min)...............................................217
10.24.18
Basic stage heating — PWM cycle heating (min)......................................................................218
10.24.19
Basic stage heating — Maximum control value (0 - 255)...........................................................218
10.24.20
Basic stage heating — Minimum control value for basic load (0 to 255)....................................218
10.24.21
Settings of basic load — Minimum control value for basic load > 0 ...........................................219
10.24.22
Basic load settings — Basic load active when controller is off...................................................219
10.24.23
Setpoint settings — Setpoint temperature for heating comfort (°C) ...........................................220
10.24.24
Setpoint settings — Reduction for standby heating (°C)............................................................220
10.24.25
Setpoint settings — Reduction for ECO heating (°C) ................................................................220
10.24.26
Setpoint settings — Set-point temperature for frost protection (°C)...........................................221
10.24.27
Setpoint settings — Send current setpoint ................................................................................221
10.24.28
Setpoint settings — Cyclic sending of the current set-point temperature (min)..........................221
10.24.29
Setpoint adjustment — Maximum manual increase during heating mode (0 - 9°C)...................221
10.24.30
Setpoint adjustment — Maximum manual reduction during heating mode (0 - 9°C)..................222
10.24.31
Setpoint adjustment — Resetting of the manual adjustment for receipt of a basic setpoint.......222
10.24.32
Setpoint adjustment — Resetting the manual adjustment for change of operating mode..........222
10.24.33
Setpoint adjustment — Resetting the manual adjustment via object .........................................223
10.24.34
Setpoint adjustment — Permanent storage of on-site operation ...............................................223
10.24.35
Temperature reading — Inputs of temperature reading.............................................................223

Table of contents
Product manual 2CKA00xx73xxxxx
│
10
10.24.36
Temperature reading — Inputs of weighted temperature reading .............................................223
10.24.37
Temperature reading — Weighting of internal measurement (0 to 100%).................................224
10.24.38
Temperature reading — Weighting of external measurement (0 to 100%)................................224
10.24.39
Temperature reading — Weighting of external measurement 2 (0 to 100%).............................224
10.24.40
Temperature reading — Cyclic sending of the actual temperature (min)...................................224
10.24.41
Temperature reading — Difference of value for sending the actual temperature (x 0.1°C)........225
10.24.42
Temperature reading — Adjustment value for internal temperature measurement (x 0.1°C) ....225
10.24.43
Temperature reading — Monitoring time for temperature reading (0 = no monitoring) (min) .....225
10.24.44
Temperature reading — Control value for fault (0 - 255) ...........................................................226
10.24.45
Alarm functions — Frost alarm temperature for HVAC and RHCC status (°C) ..........................227
10.24.46
Alarm functions — Heat alarm temperature for RHCC status (°C) ............................................227
10.24.47
Control of additional heating stage — Temperature difference to basic stage (x 0.1°C)............227
10.24.48
Control of additional heating stage — Additional heating type...................................................228
10.24.49
Control of additional heating stage — P-component (x 0.1°C) ..................................................228
10.24.50
Control of additional heating stage — I-component (min)..........................................................229
10.24.51
Cooling control — Cooling type .................................................................................................229
10.24.52
Cooling control — P-component (x 0.1°C).................................................................................230
10.24.53
Cooling control — I-component (min.) .......................................................................................230
10.24.54
Cooling control - Extended settings...........................................................................................230
10.24.55
Basic stage cooling ...................................................................................................................231
10.24.56
Basic stage cooling — Status object cooling .............................................................................231
10.24.57
Basic stage cooling — Mode of the control value ......................................................................231
10.24.58
Basic stage cooling — Hysteresis (x 0.1°C) ..............................................................................232
10.24.59
Basic stage cooling — Cyclic sending of the control value (min)...............................................232
10.24.60
Basic stage cooling - PWM cycle cooling (min) .........................................................................233
10.24.61
Basic stage cooling — Maximum control value (0 - 255) ...........................................................233
10.24.62
Basic stage cooling — Minimum control value for basic load (0 to 255) ....................................233
10.24.63
Settings of basic load — Minimum control value for basic load > 0 ...........................................234
10.24.64
Basic load settings — Basic load active when controller is off...................................................234
10.24.65
Setpoint settings — Setpoint temperature for cooling comfort (°C) ...........................................235
10.24.66
Setpoint settings — Increase for standby cooling (°C) ..............................................................235
10.24.67
Setpoint settings — Increase for ECO cooling (°C) ...................................................................235
10.24.68
Setpoint settings — Set-point temperature for heat protection (°C) ...........................................236
10.24.69
Setpoint settings — Send current setpoint ................................................................................236
10.24.70
Setpoint settings — Cyclic sending of the current set-point temperature (min)..........................236
10.24.71
Setpoint adjustment — Maximum manual increase during cooling mode (0 - 9°C) ...................236
10.24.72
Setpoint adjustment — Maximum manual reduction during cooling mode (0 - 9°C) ..................237
10.24.73
Setpoint adjustment — Resetting of the manual adjustment for receipt of a basic setpoint.......237
10.24.74
Setpoint adjustment — Resetting the manual adjustment for change of operating mode..........237
10.24.75
Setpoint adjustment — Resetting the manual adjustment via object .........................................238
10.24.76
Setpoint adjustment — Permanent storage of on-site operation ...............................................238
10.24.77
Setpoint adjustment — Permanent storage of on-site operation ...............................................238
10.24.78
Temperature reading — Inputs of temperature reading.............................................................238
10.24.79
Temperature reading — Inputs of weighted temperature reading .............................................239
10.24.80
Temperature reading — Weighting of internal measurement (0 to 100%).................................239
10.24.81
Temperature reading — Weighting of external measurement (0 to 100%)................................239
10.24.82
Temperature reading — Weighting of external measurement 2 (0 to 100%).............................240
10.24.83
Temperature reading — Cyclic sending of the actual temperature (min)...................................240
10.24.84
Temperature reading — Difference of value for sending the actual temperature (x 0.1°C)........240
10.24.85
Temperature reading — Adjustment value for internal temperature measurement (x 0.1°C) ....241
10.24.86
Temperature reading — Monitoring time for temperature reading (0 = no monitoring) (min) .....242
10.24.87
Temperature reading — Control value for fault (0 - 255) ...........................................................242

Table of contents
Product manual 2CKA00xx73xxxxx
│
11
10.24.88
Alarm functions - Condensate water alarm................................................................................242
10.24.89
Alarm functions — Dew point alarm ..........................................................................................243
10.24.90
Alarm functions — Frost alarm temperature for HVAC and RHCC status (°C) ..........................243
10.24.91
Alarm functions — Heat alarm temperature for RHCC status (°C) ............................................243
10.24.92
Summer compensation .............................................................................................................243
10.24.93
Summer compensation — Summer compensation ...................................................................244
10.24.94
Summer compensation -— (Lower) Starting temperature for summer compensation (°C) ........245
10.24.95
Summer compensation — Offset of the set-point temperature for the entry into summer
compensation (x 0.1°C).............................................................................................................245
10.24.96
Summer compensation — (Upper) exit temperature for summer compensation (°C)................245
10.24.97
Summer compensation — Offset of the set-point temperature for the exit from summer
compensation (x 0.1°C).............................................................................................................246
10.24.98
Control of additional cooling stage — Cooling type ...................................................................247
10.24.99
Control of additional cooling stage — P-component (x 0.1°C)...................................................247
10.24.100
Control of additional cooling stage — P-component (min).........................................................248
10.24.101
Combined heating and cooling modes ......................................................................................248
10.24.102
Combined heating and cooling modes — Switchover of heating/cooling...................................248
10.24.103
Combined heating and cooling modes — Operating mode after reset ......................................249
10.24.104
Combined heating and cooling modes — Heating/cooling control value output ........................249
10.24.105
Setpoint settings — Setpoint for heating comfort = setpoint for cooling comfort........................249
10.24.106
Setpoint settings — Hysteresis for switchover heating/cooling (x 0.1°C)...................................250
10.24.107
Setpoint settings — Setpoint temperature for heating and cooling comfort (°C) ........................250
10.24.108
Temperature reading — Operating mode for fault .....................................................................250
10.24.109
Combined heating and cooling modes — Additional heating/cooling stage control value
output ........................................................................................................................................251
11
Communication objects .............................................................................................................................252
12
Operation ...................................................................................................................................................274
12.1
General control and display functions ...........................................................................................274
12.2
Control elements ............................................................................................................................276
12.2.1
Basic structures of control elements..........................................................................................277
12.2.2
Additional basic principles .........................................................................................................278
12.2.3
Adjustable control elements ......................................................................................................280
12.3
Special functions ............................................................................................................................289
12.3.1
Editing .......................................................................................................................................289
12.3.2
Adding control elements to the dashboard ................................................................................290
12.3.3
Access to pages........................................................................................................................291
12.3.4
Return to the previous page ......................................................................................................291
12.4
Operating actions of the "Door communication" application .........................................................292
12.4.1
Setting up of video surveillance.................................................................................................294
12.4.2
Establishing a speech and video connection.............................................................................295
12.4.3
Opening the door ......................................................................................................................296
12.4.4
Activating mute (mite timer).......................................................................................................297
12.4.5
Switching light ...........................................................................................................................298
12.4.6
Events and image storage / history ...........................................................................................299
12.5
Control actions of additional applications ......................................................................................300
12.5.1
Presence simulation ..................................................................................................................300
12.5.2
Fault and alarm messages ........................................................................................................302
12.5.3
Time programs ..........................................................................................................................306
12.6
Inserting the micro SD card (SDHC)..............................................................................................309

Table of contents
Product manual 2CKA00xx73xxxxx
│
12
12.7
System settings..............................................................................................................................309
12.7.1
System settings - Display ..........................................................................................................311
12.7.2
System settings - Sound ...........................................................................................................313
12.7.3
System settings - Network connections.....................................................................................314
12.7.4
System settings - Time and date ...............................................................................................315
12.7.5
System settings - Access management.....................................................................................316
12.7.6
System settings - User settings.................................................................................................317
12.7.7
System settings - Video surveillance.........................................................................................317
12.7.8
System settings - Intercom list...................................................................................................318
12.7.9
System settings - Programming button......................................................................................320
12.7.10
System settings - Extended settings .........................................................................................320
12.7.11
System settings - Software update............................................................................................321
12.7.12
System settings - Via.................................................................................................................322
12.7.13
Terminal resistor .......................................................................................................................323
12.7.14
Setting master/slave switches ...................................................................................................323
13
Update .......................................................................................................................................................324
13.1
Transfer of PID file (Configuration file) ..........................................................................................324
14
Addressing .................................................................................................................................................325
15
Maintenance ..............................................................................................................................................326
15.1
Cleaning .........................................................................................................................................326
16
Notes..........................................................................................................................................................326
17
Index ..........................................................................................................................................................327

Notes on the instruction manual
Product manual 2CKA00xx73xxxxx
│
13
1 Notes on the instruction manual
Please read through this manual carefully and observe the information it contains. This will
assist you in preventing injuries and damage to property, and ensure both reliable operation and
a long service life for the device.
Please keep this manual in a safe place.
If you pass the device on, also pass on this manual along with it.
ABB accepts no liability for any failure to observe the instructions in this manual.
If you require additional information or have questions about the device, please contact ABB or
visit our Internet site at:
https://new.abb.com/en

Safety
Product manual 2CKA00xx73xxxxx
│
14
2 Safety
The device has been constructed according to the latest valid regulations governing technology
and is operationally reliable. It has been tested and left the factory in a technically safe and
reliable state.
However, residual hazards remain. Read and adhere to the safety instructions to prevent
hazards of this kind.
ABB accepts no liability for any failure to observe the safety instructions.
2.1 Information and symbols used
The following Instructions point to particular hazards involved in the use of the device or provide
practical instructions:
Danger
Risk of death / serious damage to health
– The respective warning symbol in connection with the signal word "Danger"
indicates an imminently threatening danger which leads to death or serious
(irreversible) injuries.
Warning
Serious damage to health
– The respective warning symbol in connection with the signal word "Warning"
indicates a threatening danger which can lead to death or serious
(irreversible) injuries.
Caution
Damage to health
– The respective warning symbol in connection with the signal word "Caution"
indicates a danger which can lead to minor (reversible) injuries.
Attention
Damage to property
– This symbol in connection with the signal word "Attention" indicates a
situation which could cause damage to the product itself or to objects in its
surroundings.
NOTE
This symbol in connection with the word "Note" indicates useful tips and
recommendations for the efficient handling of the product.
This symbol alerts to electric voltage.

Safety
Product manual 2CKA00xx73xxxxx
│
15
2.2 Intended use
The ABB SmartTouch®is a KNX touch panel which can be freely programmed. The device
serves as a comprehensive control and message unit for the entire KNX installation as well as
the representation and operation of KNX and free@home standard functions. The touch panel
can be used as terminal device (indoor video station) for communication with the ABB-
Welcome®outdoor stations. As part of the ABB-Welcome®door communication system it
operates exclusively with the components of this system.
The device is intended for the following:
■Operation according to the listed technical data
■Installation in dry interior rooms
■Use with the connecting options available on the device
The intended use also includes adherence to all specifications in this manual.
2.3 Improper use
Each use not listed in “Intended use“ on page 15 is deemed improper use and can lead to
personal injury and damage to property.
ABB is not liable for damages caused by use deemed contrary to the intended use of the
device. The associated risk is borne exclusively by the user/operator.
The device is not intended for the following:
■Unauthorized structural changes
■Repairs
■Outdoor use
■The use in bathroom areas
■Insert with an additional bus coupler

Safety
Product manual 2CKA00xx73xxxxx
│
16
2.4 Target group / Qualifications of personnel
2.4.1 Operation
No special qualifications are needed to operate the device.
2.4.2 Installation, commissioning and maintenance
Installation, commissioning and maintenance of the device must only be carried out by trained
and properly qualified electrical installers.
The electrical installer must have read and understood the manual and follow the instructions
provided.
The electrical installer must adhere to the valid national regulations in his/her country governing
the installation, functional test, repair and maintenance of electrical products.
The electrical installer must be familiar with and correctly apply the "five safety rules" (DIN VDE
0105, EN 50110):
1. Disconnect
2. Secure against being re-connected
3. Ensure there is no voltage
4. Connect to earth and short-circuit
5. Cover or barricade adjacent live parts

Safety
Product manual 2CKA00xx73xxxxx
│
17
2.5 Cyber security
The industry faces intensifying cyber security risks. In order to increase stability, safety and
robustness of its solutions, ABB has formally established cyber security robustness testing as
part of the product development process.
The following measures are prerequisite for the safe operation of your system. ABB accepts no
liability for non-observance.
Access control and limitation
The careful isolation of the system against unauthorized access is the basis for every protective
concept. Only authorized persons (fitter, caretaker, tenant) are allowed physical access to the
IP network or bus system and its components. This also includes the device described in this
instruction manual.
The best possible protection of the IP or network media (WLAN) and the transfer nodes must be
guaranteed already during planning and installation. Sub-distributions with fieldbus devices
must be lockable or be in rooms to which only authorized persons have access.
Bus cabling
■The ends of the bus cables must not be visible, i.e. they must not project out of walls or
channels, either inside or outside of the building.
■Bus cables in outdoor areas or in areas with limited protection represent an increased safety
risk. The physical access should be made exceptionally difficult.
IP Network
The local network represents a sensitive component for secure communication. That is why
unauthorized access to the local network should be prevented. The normal safety mechanisms
for IP networks are to be used, e.g.:
■Secure encryption of wireless networks
■Use of complex passwords and protection of these against unauthorized persons
■Physical access to network interfaces (Ethernet interfaces) and network components
(router, switches) should only be possible in protected areas.
■MAC filter (table with certified device addresses)
Connection to the Internet or the local IP network
To prevent improper use, no router ports from the Internet into the building network or home
network are to be opened to the ABB SmartTouch®. A VPN tunnel is suitable for safe remote
control.
The stable and reliable function of the device also depends on the reliability of the local IP
network to which the server is connected. For this reason additional network components are to
be used to repel the DoS attacks (denial of service) from the Internet. Such attacks can
overload the local IP network or the individual components and make them inaccessible.

Safety
Product manual 2CKA00xx73xxxxx
│
18
Safety of user accounts
Set a strong access password during initial commissioning. Use passwords that you have
received from the administrator only for the first login.
Keep passwords secret and use a password manager with two-factor login as memory aid, e.g.
Keepass.
Updates
The device supports various update options. A detailed overview is available in .
Backup / Restoration
The user can backup / restore device settings. To perform the backup the user must enter a
password. This password is used as safety key to encrypt the backup information. If the user
wants to restore the device settings via a backup file, he must first enter the defined password
so that the backup information can be decrypted.
Solutions for protection against malware
The product is not susceptible to malware, because a user-defined code cannot be executed on
the system. The only option of updating the software is the update of the firmware. Only a
firmware signed by ABB is accepted.
Password rules
The default system password is 345678. During the initial opening of the page the user is
requested to change the password.

Safety
Product manual 2CKA00xx73xxxxx
│
19
2.5.1 Ports and services for supporting the main functionality
To support the main functionalities of the device, communication via specific ports and services
must be possible in your local network. Contact your network administrator to set up, if
necessary, the appropriate port sharing.
Attention!
Enabling the port increases the risk of cyber attacks.
– Assign only necessary enabling.
– Regularly check which ports are enabled for which purpose.
In the following table the TCP and UDP services listed on the device are summarized:
Port Service Purpose
5222 TCP Service for XMPP client.
5269 TCP Xmpp server
5060/TCP SIP
Port 5060/TCP is used by SIP Server Flexisip/0.5.0 (sofia-sip-
nta/2.0).
SIP (Session Initiation Protocol) is a communication protocol for
the introduction of communication sessions between systems.
The protocol is used mostly in IP Telephony networks / systems
to set up, control, and finish sessions between two or more
systems.
5060/UDP SIP Port 5060/UPD is used by SIP Server Flexisip/0.5.0 (sofia-sip-
nta/2.0).
5061/TCP SIP-TLS
Port 5061/TCP is used by SIP Server Flexisip/0.5.0 (sofia-sip-
nta/2.0). The use of SSL encryption makes the encryption of
communication sessions possible.
50602/UDP SIP Is used by SIP server STUn.
2222/TCP Private Is used for b2bsip.
2224/TCP Private Is used for b2bsip.
8277/TCP Private
Is used for internal process communication of safety storage
components. This port is limited only for local access by
iptables.
Random
Port/UDP Private The random UDP port is used for the communication of b2bsip.

Safety
Product manual 2CKA00xx73xxxxx
│
20
Network performance
Type Value
Ethernet 100 Mbps (148,800 packets/s)
ARP 20 Mbps (29,760 packets/s)
ICMP 100 Mbps (148,800 packets/s)
IP 60 Mbps (89,280 packets/s)
Table of contents
Other ABB Touch Panel manuals
Popular Touch Panel manuals by other brands

Extron electronics
Extron electronics TLP Pro 1220MG Setup guide

Advantech
Advantech SPC-515 Series user manual

Gonnheimer Elektronic
Gonnheimer Elektronic D122.A Series user manual

Hakko Electronics
Hakko Electronics Monitouch V7 user manual

DFI
DFI TPC150 Quick manual

OHAUS
OHAUS DEFENDER 7000 XtremeW Series user guide