The Sensor Connection tca-ms-k-1 User manual

11-2013 Page 1 of 6

11-2013 Page 2 of 6
Instrucon Manual - TCA-MS-K-1 Thermocouple Ampl fier
Type K Mini

11-2013 Page 3 of 6
Instrucon Manual - TCA-MS-K-1 Thermocouple Ampl fier
Mulpl er:
Example:

11-2013 Page 4 of 6
Instrucon Manual - TCA-MS-K-1 Thermocouple Ampl fier
Input Specifications
Number of Input Channels 1
Thermocouple Type K (ungrounded)
Measuring Range + 2 to +2282°F (0 to +1250°C)
Input Connection Mini Thermocouple Jack
Analog Output Specifications
Number of Output Channels 1
Analog Output Range 0 to +5 VDC
Scale Factor (nominal) 2.2 mV / °F (4.0 mV / °C)
Resolution Infinite
Response Time > 1 mS
Non-Linearity < +/- 2% FRO
Output Cable conductor, 22 AWG,
PVC jacket, 6 foot long
Power Specifications
Supply Voltage 10 to 2 VDC
Current Draw < 50 mA
Environmental Specifications
Operating Temperature Range + 2 to +158°F (0 to +70°C)
Humidity 85% Max. RH (non-condensing)
Liquid & Dust Protection IP51
Mechanical Specifications
Housing Dimensions (L x W x H) 2.5 x 2.5 x 0.9 inch
Weight oz (85 g)

11-2013 Page 5 of 6
Instrucon Manual - TCA-MS-K-1 Thermocouple Ampl fier

11-2013 Page 6 of 6