THERMA Big Dipper 50000 Series Installation instructions

Copyright ©2015 Big Dipper® Thermaco, Inc. • P.O. Box 2548 • Asheboro, NC 27204
Toll Free: (800) 633-4204 • V: (336) 629-4651 • F: (336) 626-5739
[email protected] • www.big-dipper.com
Installation & Operation Instructions
For Big Dipper 50000 Series
Internal Strainer (IS) Units
Models W-200-IS-SS, W-250-IS-SS, W-350-IS-SS
and W-500-IS-SS (Including 230 VAC Units)
Part# MNL-ISPS40000
ADB
* Please consult Thermaco, Inc. for specic models
tested, certied and/or listed by these organizations.
®
1
1
2
2
3
3
4
4
A A
B B
C C
D D
THIS DRAWING CONTAINS PROPRIETARY AND PATENTED MATERIAL. THIS DRAWING MAY NOT BE REPRODUCED IN WHOLE OR PART WITHOUT
WRITTEN CONSENT FROM THERMACO, INC. POSSESSION OF THIS DRAWING DOES NOT CONSTITUTE THE RIGHT TO MANUFACTURE.
POSSESSION OF THIS DRAWING DOES CONSTITUTE AN IMPLIED NONDISCLOSURE AGREEMENT BETWEEN THERMACO, INC. AND THE HOLDER OF
THIS DRAWING. DO NOT DESTROY THIS DRAWING, IT IS THE SOLE PROPERTY OF THERMACO, INC. AND MUST BE RETURNED UPON REQUEST.
MATERIAL (UNLESS NOTED)
FINISH (UNLESS NOTED)
646 GREENSBORO STREET
PO BOX 2548, ASHEBORO, NC 27203
VOICE 336-629-4651 FAX 336-626-5739 Decimals
.XX +/- .03
.XXX +/- .015
Unless otherwise specified
Dimensions are in inches
Tolerances
Angular
+/- 1°
CHECKED SIZE REV. NO. DWG NO.
PART NO. C
SCALE RELEASE DATE SHEET OF
ENGINEERING
DRAWN DATE
THIRD ANGLE PRO JECTION
28.50 in
723.9 mm
17.85 in
453.4 mm
2.375 in
60.3 mm
14.55 in
369.6 mm
6.00 in
152.4 mm
25.50 in
647.7 mm
24.60 in
624.9 mm
1.75 in
44.5 mm
8.80 in
223.5 mm
W-200-SS-SD
T MCBRIDE 2/25/15
2.00 in
50.8 mm

©2015 Thermaco, Inc. All rights reserved • Patented/Patents Pending • Specications subject to change without notice
Thermaco, Inc. • 646 Greensboro St. • Asheboro, N. C. 27204-2548 • Phone (336) 629-4651 MNL-ISPS50000 2
50000 Series
Table of Contents
Table of Contents
IS System Overview 3
IS System Maintenance 4
IS Digital Control Operation 5
IS System Troubleshooting 7
How To Reverse IS System Operation 8
Plumbing Installation 9
Vented Flow Control Installation 12
Electrical Installation 12
IS System Wiring Diagram 14
IS Component Identication 15
IS Replacement Parts 17
Limited Warranty 18

©2015 Thermaco, Inc. All rights reserved • Patented/Patents Pending • Specications subject to change without notice
Thermaco, Inc. • 646 Greensboro St. • Asheboro, N. C. 27204-2548 • Phone (336) 629-4651 MNL-ISPS50000 3
50000 Series
Big Dipper® Internal Strainer System Overview
The Thermaco, Inc. Big Dipper®Automatic Grease and Oils
Removal System removes free-oating grease & oils from
kitchen drain water ows. As most food service facility manag-
ers already know, grease buildup within a building’s plumbing
drainage system is a major cause of problems due to drain line
blockages. These problems jeopardize normal operations as
well as create health and safety hazards within the facility itself.
The proper installation of a Big Dipper System can reduce or
eliminate grease problems. Use of the Big Dipper assures
minimization and/or elimination of costly sewer surcharges and
nes through efcient separation and removal of free-oating
grease & oils. In addition, the Big Dipper also helps reduce or
eliminate pumping and disposal costs associated with conventional grease separators or intercep-
tors. The recovered grease & oils are substantially water-free and are suitable for recycling by local
rendering and/or biodiesel companies.
The Big Dipper system is an automatic, self-cleaning device. As greasy kitchen efuent drains from
kitchen xtures, the unit contains the grease & oils. These separate from the efuent and rise to the
surface of the separator tank. The unit automatically skims the contained grease & oils and transfers
the grease & oils to a collection container. A digital control maintains the self cleaning operation,
activating the skimming wheel periodically based on the setting chosen. Only the “cleaned” water
exits the unit and ows into the facility drain lines. The Big Dipper IS automatic systems operate most
efciently when servicing single xtures such as a 1 to 3-compartment sink or a pre-rinse station.
The Big Dipper system’s compact footprint allows installation directly at the source where grease
problems originate. The system design also allows easy maintenance and operation requiring only
a minimal amount of daily and weekly maintenance to maintain peak operating performance.
The Big Dipper system design allows for maximum installation exibility. Reversing the system op-
eration is a simple as rotating the cover assembly of the unit.
Hydromechanical grease interceptors*, grease separators, automatic recovery units, grease removal
devices and other similar plumbing devices receiving kitchen ows from sinks, oor drains, woks and
other food bearing sources may generate odors. There are many factors inuencing odor evolu-
tion and dissemination. These include room ventilation, kitchen menu, ambient temperatures, ware
washing practices, grease/oil input, daily input uid volume, sanitizers, installation plumbing design
and product maintenance/upkeep. Odors are usually prevented by good area ventilation, frequent
uid inputs, good product maintenance practices and proper product installation. Additional steps,
including aeration, chlorination, improved area ventilation and additional maintenance control, may
be needed at some sites.
*Devices formerly referred to as grease traps are now called hydromechanical grease interceptors.
Big Dipper® Internal Strainer (IS)
System Overview

©2015 Thermaco, Inc. All rights reserved • Patented/Patents Pending • Specications subject to change without notice
Thermaco, Inc. • 646 Greensboro St. • Asheboro, N. C. 27204-2548 • Phone (336) 629-4651 MNL-ISPS50000 4
50000 Series
Big Dipper® Internal Strainer (IS)
System Maintenance
*CAUTION! DISCONNECT POWER TO UNIT BEFORE CLEANING
to prevent damage to the unit and personal injury
*NOTE: Before energizing unit after cleaning, ll tank with water
to protect wipers and heater from damage
Big Dipper® Internal Strainer (IS) System Maintenance
Daily Maintenance:
(A) Empty the clear plastic grease/oils collection container (located beside the unit) prior to its be-
coming full once each day. The Big Dipper recovers grease and oil virtually water-free so that they
can be recycled. The collector container should be washed periodically so as to maintain the easy
viewing translucent characteristic of the collector.
(B) The internal strainer basket should be removed and emptied into a garbage container by shaking
briskly. Wash the inside and outside surfaces of the strainer after emptying.
Weekly Maintenance:
(A) Check the collection trough and the wiper blades for any solids build-up. Wipe off any accumulated
deposits and assure that the wiper blades are clipped in place properly.
(B) Press the Start button (on the bottom of the user interface) momentarily to ensure that the motor
and skimming wheel are still operating correctly.
(C) Check the thickness of the grease layer at the top of the unit. There should be no appreciable
amount of grease or oil left in the tank immediately after the daily automatic skimming cycle. If there
is more than a 1/2” (13 mm) thick layer of grease after the skimming cycle, this indicates a need to
increase the skimming time. Increase the digital control settings accordingly until a clean unit ap-
pearance is obtained after the automatic skimming cycle. A simple guide is to change to the next
higher setting (Light [I] to Moderate [II] or Moderate [II] to Heavy [III]) and run for a period of time until
enough grease is being skimmed from the tank.
Quarterly Maintenance:
(A) The internal strainer basket in the unit is designed to remove incidental solids from kitchen drain
ows. Over a period of time, sediment consisting of very ne particles may begin to accumulate on the
bottom of the unit. If this build-up is allowed to continue, it may eventually block the outlet bafe. To
prevent this from occurring, remove the lid and stir the bottom of the unit with a long handled spatula
while water is owing to ush out the sediment. Occasionally drain and clean the unit thoroughly.
Properly used, a wet-vac may be appropriate for this purpose.

©2015 Thermaco, Inc. All rights reserved • Patented/Patents Pending • Specications subject to change without notice
Thermaco, Inc. • 646 Greensboro St. • Asheboro, N. C. 27204-2548 • Phone (336) 629-4651 MNL-ISPS50000 5
50000 Series
VOICE 336-629-4651 FAX 336-626-5739
PO BOX 2548, ASHEBORO, NC 27203
646 GREENSBORO STREET
DESTROY THIS DRAWING, IT IS THE SOLE PROPERTY OF THERMACO, INC. AND MUST BE RETURNED UPON REQUEST.
OF THIS DRAWING DOES CONSTITUTE AN IMPLIED AGREEMENT BETWEEN THERMACO, INC. AND THE HOLDER OF THIS DRAWING. DO NOT
WRITTEN CONSENT FROM THERMACO, INC. POSSESSION OF THIS DRAWING DOES NOT CONSTITUTE THE RIGHT TO MANUFACTURE. POSSESSION
THIS DRAWING CONTAINS PROPRIETARY AND PATENTED MATERIAL. THIS DRAWING MAY NOT BE REPRODUCED IN WHOLE OR IN PART WITHOUT
.XXX +/- 0.015
.XX +/- 0.03
Decimals
+/-1°
Angular
Tolerances
Dimensions are in inches
Unless otherwise specified
MATERIAL (UNLESS NOTED)
FINISH (UNLESS NOTED) PART NO.
CHECKED
ENGINEERING
DRAWN DATE
A
THIRD ANGLE PROJECTION
RELEASE DATE
REVISIONS
ZONE REV DESCRIPTION DATE APPROVED
SCALE SHEET OF
SIZE REV. NO. DWG NO.
Digital Control Operation (Default Modes)
Big Dipper® IS System
Digital Control Operation
Timed Skimming Default
Through the “User Interface” three
levels of skimming may be selected in
the “default” mode. By selecting one of
the skimming buttons – I, II, or III - the
skimming cycle (see table below) is
activated. The LED associated with
the selected button is illuminated
continuously as an indicator of the
selected skim cycle and as a “power
on” indicator. If the skimming level is
changed during an active skimming
cycle, the next active skim cycle will be
at the new setting (The LED associated
with the newly selected level will change
immediately). If the skimming cycle
is changed between active skimming
cycles the next skim cycle will be at the
new level.
Motor Exercising
For all default mode skimming levels, the
motor will be energized for 30 seconds
every 9.5 hours. Only the motor will be
energized (no heater operation) at these
exercising times.
Heavy Setting:
Recommended for
Heavy Grease Output
(Steakhouses, Buffets,
Heavy Grease
producing sites***)
Start Button: Press
to begin a cycle early
or to test operation..
Light Setting:
Recommended for
Light Grease Output
(Small Cafes, Coffee/
Ice Cream shops***)
Moderate Setting:
Recommended for
Moderate Grease Output
(Quick and Full-Service
restaurants***)
Start Button Operation
Any time the start button is depressed the “time between skims” the digital control goes to its maximum time and
operation begins for the selected skim level. After this skimming cycle the normal time delay to the next skim cycle
is used (skim cycle resets when the start button is depressed).
Heater Operation
The heater operates under Thermistor control any time the skimmer motor is energized and anytime the liquid
temperature drops to 40º F to prevent liquid from freezing. Contact Thermaco for programming alternative heater
settings.
Default Modes - Normal Operation*
Button Selected Skim Time Delay Between Skims**
Light (I) 15 Minutes 76 Hours
Moderate (II) 30 Minutes 19 Hours
Heavy (III) 60 Minutes 19 Hours
* For Extreme Conditions see next page.
** Delay between Skims is the time from the start of the 1st skim to the start of the next skim.
*** Only examples, actual mode needed will vary depending upon menu, warewashing procedures, etc.

©2015 Thermaco, Inc. All rights reserved • Patented/Patents Pending • Specications subject to change without notice
Thermaco, Inc. • 646 Greensboro St. • Asheboro, N. C. 27204-2548 • Phone (336) 629-4651 MNL-ISPS50000 6
50000 Series
Digital Control Operation (Extreme Modes)
Big Dipper® IS System
Digital Control Operation
Extreme Operation
For Food Service Operations which produce more grease and need additional run-time, the 40000 Series Big Dipper
provides additional modes for extreme operation. In order to access these modes:
1. Remove power from CLA by unplugging unit or lifting it to disengage the safety switch (found on
underside of the back of assembly).
2. Reapply power while holding down the Heavy Mode (III) Button.
3. The button (III) will blink temporarily, indicating which operation level has been selected.
4. Select desired mode at skim times/frequencies listed below.
Extreme Modes
Button Selected Skim Time Delay Between Skims*
Light (I) 90 Minutes 19 Hours
Moderate (II) 120 Minutes 19 Hours
Heavy (III) 120 Minutes 9.5 Hours
* Delay between Skims is the time from the start of the 1st skim to the start of the next skim.
To return to Default Modes, follow the instructions above, but press the Light Mode (I) Button instead of the Heavy
Mode (III) Button. The Light Mode (I) Button will temporarily blink to indicate this operational level has been
selected.
VOICE 336-629-4651 FAX 336-626-5739
PO BOX 2548, ASHEBORO, NC 27203
646 GREENSBORO STREET
DESTROY THIS DRAWING, IT IS THE SOLE PROPERTY OF THERMACO, INC. AND MUST BE RETURNED UPON REQUEST.
OF THIS DRAWING DOES CONSTITUTE AN IMPLIED AGREEMENT BETWEEN THERMACO, INC. AND THE HOLDER OF THIS DRAWING. DO NOT
WRITTEN CONSENT FROM THERMACO, INC. POSSESSION OF THIS DRAWING DOES NOT CONSTITUTE THE RIGHT TO MANUFACTURE. POSSESSION
THIS DRAWING CONTAINS PROPRIETARY AND PATENTED MATERIAL. THIS DRAWING MAY NOT BE REPRODUCED IN WHOLE OR IN PART WITHOUT
.XXX +/- 0.015
.XX +/- 0.03
Decimals
+/-1°
Angular
Tolerances
Dimensions are in inches
Unless otherwise specified
MATERIAL (UNLESS NOTED)
FINISH (UNLESS NOTED) PART NO.
CHECKED
ENGINEERING
DRAWN DATE
A
THIRD ANGLE PROJECTION
RELEASE DATE
REVISIONS
ZONE REV DESCRIPTION DATE APPROVED
SCALE SHEET OF
SIZE REV. NO. DWG NO.
Hold down Heavy
Mode (III) Button
when connecting
power to unit to
switch to extreme
modes.
Hold down Light
Mode (I) Button
when connecting
power to unit to
switch back to
default modes.

©2015 Thermaco, Inc. All rights reserved • Patented/Patents Pending • Specications subject to change without notice
Thermaco, Inc. • 646 Greensboro St. • Asheboro, N. C. 27204-2548 • Phone (336) 629-4651 MNL-ISPS50000 7
50000 Series
Big Dipper® IS System
Troubleshooting
Big Dipper unit overows
(1) Check to see that the outlet pipe is not reduced to a
smaller size, the outlet piping is vented, has as few 90
degree outlet turns as possible, and that no “P” trap is
installed on the outlet. Re-plumb the piping, if neces-
sary. Check outlet piping for clogs. Have a plumber
clean the line, if necessary.
(2) Make sure that the solids strainer is in place and
emptied daily.
(3) Check the bottom of the grease chamber for exces-
sive solids and silt buildup which may be blocking the
outlet bafe. Disconnect the power and use a long
handled spatula or similar instrument to stir the bottom
while water ows through the unit. If necessary, drain
and clean the sediment from the unit. To prevent recur-
rence, schedule this cleaning to be done on a regular
basis (properly used, a wet vac may be appropriate for
cleaning sediment from the bottom of the unit).
(4) Make sure the ow rate to the unit does not exceed
the maximum ow rate, which is shown on the nameplate.
If necessary, have a plumber install an approved ow
control to restrict the inlet ow to the specied level or
install a properly sized Big Dipper for the application.
Excessive water observed in the grease collection
container
(1) Check Digital Control for excessive “on” time. Unit
will pick up incidental water after all grease is removed.
If necessary, reduce the digital control setting (i.e.
Moderate [II] to Light [I]) until no water is observed in
the grease collection container.
(2) Make sure that the water ow to the unit does not
exceed the rated ow and there are no drain line clogs
downstream from the unit.
No grease is collected in the container
(1) Check to be sure the power is on and the correct
setting is chosen. One of the setting buttons should be
illuminated. If none of the setting buttons are illuminated,
the unit is not powered.
(2) Lift the sump cover and clean away any buildup
that may be present on the wiper blades or collection
trough. Make sure the wiper blade(s) are properly in
place on the skimmer wheels. Replace wiper blades
when worn or warped.
(3) Press the Start Button on the bottom of the user inter-
face to ensure that the skimming wheel turns.
CAUTION: Keep your hands away from moving parts
to avoid possible injury. If the skimmer motor does not
come on, the motor assembly may need to be replaced.
(4) Check for congealed grease in the unit. If the Big
Dipper’s heating element is not warming the unit, the
heating element may need to be replaced.
(5) Some sites do not generate enough grease to be
captured by the skimming process. Set Control for
minimum operation - Setting [I] for Light Skimming
Operation.
Objectionable odor
(1) Make sure grease/oil is being skimmed properly
from the unit.
(2) Check Digital Control for excessive “on” time. Unit
will pick up incidental water after all grease is removed.
If necessary, reduce the digital control setting (i.e.
Moderate [II] to Light [I]) until no water is observed in
the grease collection container.
(3) If excessive sediment has collected on the bottom
of the unit, clean the unit as described in item 3 in “Big
Dipper unit overows.”
(4) Clean the solids strainer and grease collection
container more frequently.
(5) Grease interceptors, grease separators, automatic
recovery units, grease removal devices and other
similar plumbing devices receiving kitchen ows from
sinks, oor drains, woks and other food bearing sources
may generate odors. There are many factors inuenc-
ing odor evolution and dissemination. These include
room ventilation, kitchen menu, ambient temperatures,
ware washing practices, grease/oil input, daily input
uid volume, sanitizers, installation plumbing design
and product maintenance/upkeep. Odors are usually
prevented by good area ventilation, frequent uid in-
puts, good product maintenance practices and proper
product installation. Additional steps, including aeration,
chlorination, improved area ventilation and additional
maintenance control, may be needed at some sites.

©2015 Thermaco, Inc. All rights reserved • Patented/Patents Pending • Specications subject to change without notice
Thermaco, Inc. • 646 Greensboro St. • Asheboro, N. C. 27204-2548 • Phone (336) 629-4651 MNL-ISPS50000 8
50000 Series
1
1
2
2
3
3
4
4
A A
B B
C C
D D
THIS DRAWING CONTAINS PROPRIETARY AND PATENTED MATERIAL. THIS DRAWING MAY NOT BE REPRODUCED IN WHOLE OR PART WITHOUT
WRITTEN CONSENT FROM THERMACO, INC. POSSESSION OF THIS DRAWING DOES NOT CONSTITUTE THE RIGHT TO MANUFACTURE.
POSSESSION OF THIS DRAWING DOES CONSTITUTE AN IMPLIED NONDISCLOSURE AGREEMENT BETWEEN THERMACO, INC. AND THE HOLDER OF
THIS DRAWING. DO NOT DESTROY THIS DRAWING, IT IS THE SOLE PROPERTY OF THERMACO, INC. AND MUST BE RETURNED UPON REQUEST.
MATERIAL (UNLESS NOTED)
FINISH (UNLESS NOTED)
646 GREENSBORO STREET
PO BOX 2548, ASHEBORO, NC 27203
VOICE 336-629-4651 FAX 336-626-5739 Decimals
.XX +/- .03
.XXX +/- .015
Unless otherwise specified
Dimensions are in inches
Tolerances
Angular
+/- 1°
CHECKED SIZE REV. NO. DWG NO.
PART NO. C
SCALE RELEASE DATE SHEET OF
ENGINEERING
DRAWN DATE
THIRD ANGLE PRO JECTION
1
1
2
2
3
3
4
4
A A
B B
C C
D D
THIS DRAWING CONTAINS PROPRIETARY AND PATENTED MATERIAL. THIS DRAWING MAY NOT BE REPRODUCED IN WHOLE OR PART WITHOUT
WRITTEN CONSENT FROM THERMACO, INC. POSSESSION OF THIS DRAWING DOES NOT CONSTITUTE THE RIGHT TO MANUFACTURE.
POSSESSION OF THIS DRAWING DOES CONSTITUTE AN IMPLIED NONDISCLOSURE AGREEMENT BETWEEN THERMACO, INC. AND THE HOLDER OF
THIS DRAWING. DO NOT DESTROY THIS DRAWING, IT IS THE SOLE PROPERTY OF THERMACO, INC. AND MUST BE RETURNED UPON REQUEST.
MATERIAL (UNLESS NOTED)
FINISH (UNLESS NOTED)
646 GREENSBORO STREET
PO BOX 2548, ASHEBORO, NC 27203
VOICE 336-629-4651 FAX 336-626-5739 Decimals
.XX +/- .03
.XXX +/- .015
Unless otherwise specified
Dimensions are in inches
Tolerances
Angular
+/- 1°
CHECKED SIZE REV. NO. DWG NO.
PART NO. C
SCALE RELEASE DATE SHEET OF
ENGINEERING
DRAWN DATE
THIRD ANGLE PRO JECTION
1
1
2
2
3
3
4
4
A A
B B
C C
D D
THIS DRAWING CONTAINS PROPRIETARY AND PATENTED MATERIAL. THIS DRAWING MAY NOT BE REPRODUCED IN WHOLE OR PART WITHOUT
WRITTEN CONSENT FROM THERMACO, INC. POSSESSION OF THIS DRAWING DOES NOT CONSTITUTE THE RIGHT TO MANUFACTURE.
POSSESSION OF THIS DRAWING DOES CONSTITUTE AN IMPLIED NONDISCLOSURE AGREEMENT BETWEEN THERMACO, INC. AND THE HOLDER OF
THIS DRAWING. DO NOT DESTROY THIS DRAWING, IT IS THE SOLE PROPERTY OF THERMACO, INC. AND MUST BE RETURNED UPON REQUEST.
MATERIAL (UNLESS NOTED)
FINISH (UNLESS NOTED)
646 GREENSBORO STREET
PO BOX 2548, ASHEBORO, NC 27203
VOICE 336-629-4651 FAX 336-626-5739 Decimals
.XX +/- .03
.XXX +/- .015
Unless otherwise specified
Dimensions are in inches
Tolerances
Angular
+/- 1°
CHECKED SIZE REV. NO. DWG NO.
PART NO. C
SCALE RELEASE DATE SHEET OF
ENGINEERING
DRAWN DATE
THIRD ANGLE PRO JECTION
1
1
2
2
3
3
4
4
A A
B B
C C
D D
THIS DRAWING CONTAINS PROPRIETARY AND PATENTED MATERIAL. THIS DRAWING MAY NOT BE REPRODUCED IN WHOLE OR PART WITHOUT
WRITTEN CONSENT FROM THERMACO, INC. POSSESSION OF THIS DRAWING DOES NOT CONSTITUTE THE RIGHT TO MANUFACTURE.
POSSESSION OF THIS DRAWING DOES CONSTITUTE AN IMPLIED NONDISCLOSURE AGREEMENT BETWEEN THERMACO, INC. AND THE HOLDER OF
THIS DRAWING. DO NOT DESTROY THIS DRAWING, IT IS THE SOLE PROPERTY OF THERMACO, INC. AND MUST BE RETURNED UPON REQUEST.
MATERIAL (UNLESS NOTED)
FINISH (UNLESS NOTED)
646 GREENSBORO STREET
PO BOX 2548, ASHEBORO, NC 27203
VOICE 336-629-4651 FAX 336-626-5739 Decimals
.XX +/- .03
.XXX +/- .015
Unless otherwise specified
Dimensions are in inches
Tolerances
Angular
+/- 1°
CHECKED SIZE REV. NO. DWG NO.
PART NO. C
SCALE RELEASE DATE SHEET OF
ENGINEERING
DRAWN DATE
THIRD ANGLE PRO JECTION
How To Reverse Big Dipper®
IS System Operation
1) Unlatch the Unit lid. Pull the
side wings outward.
2) Lift the center module up off of
the unit, ensuring clearance for the
heater.
3) Rotate the center module
180º.
4) Lower the center module back
down on top of the unit. Move the
two side wings back into place
& fasten all latches.
1) 2)
4)3)
Grease
Outlet
Power
Cord
How To Reverse Big Dipper® IS System Unit Operation
Clearance Required
To Remove Lid
*ALWAYS UNPLUG UNIT BEFORE REMOVING LID
*SYSTEM WILL NOT OPERATE UNLESS CENTER MODULE IS IN PLACE
14.000”

©2015 Thermaco, Inc. All rights reserved • Patented/Patents Pending • Specications subject to change without notice
Thermaco, Inc. • 646 Greensboro St. • Asheboro, N. C. 27204-2548 • Phone (336) 629-4651 MNL-ISPS50000 9
50000 Series
Big Dipper® IS System
Plumbing Installation
Locating the Unit
To minimize grease build-up in piping, a Big
Dipper system should be located as close as
possible to the xture it is serving. The sys-
tem should be visible and easily accessible for
maintenance and inspection. The unit must
be in a level position. Be sure to check the
Specication Sheet for your model for the
exact clearances needed for installation. If
the system is located directly on the oor, the
bottom should be sealed to the oor with an
approved silicone type sealant. Make sure the
height above the Internal Strainer access cover
is enough to remove the strainer basket.
Inlet/Outlet Piping
The inlet and outlet piping connections require
exible sleeve pipe couplings. Keep outlet pip-
ing as straight as possible. Use only “sweep”
connections. Do not reduce the pipe sizing
on the outlet piping. Do not install “P” trap on
outlet connection of system. (Note: The system
already has a internal gas trap)
Flow Controls
Big Dipper systems are equipped with an internal
ow control located inside the inlet end of the
system. Verify its location and placement prior
to connecting the inlet piping.
Fill Unit With Water Before Applying
Power
Big Dipper systems, equipped with an electric
heating element, MUST be lled with water
before energizing the power to the system.
Failure to do so may damage the electric heating
element. These elements will NOT be replaced
under Thermaco’s Warranty.
Venting the Outlet
An outlet vent or approved vacuum breaker of
at least 1/2 the diameter of the system’s outlet
connection must be present as close as pos-
sible to the Big Dipper outlet to prevent possible
siphonage problems. Failure to provide a vent
for the system voids Thermaco’s Warranty for
the system.
For High Head Height Applications
Over Six (6) Feet (1.95 m)
Big Dipper systems are equipped with an
internal ow regulator located inside the inlet
end of the system. Verify its location and
placement prior to connecting the inlet pip-
ing. If your code requires a vertical type ow
regulator, an approved control with a ow rat-
ing matching the system’s ow rate should be
used. Note: When a Big Dipper is servicing
multiple xtures, some codes require separate
ow controls for each xture. See following
page for suggested high head height ow
regulation installation.
Do Not Use With Food Grinders, Potato
Peelers or Waste Disposal Units
If the system is connected to a Waste Disposal
Unit, Garbage Grinder or Potato Peeler, Ther-
maco’s Warranty will be void.
Note: Drawing for reference only.
Equipment must be installed in
compliance with all applicable laws,
regulations and codes, includ-
ing plumbing codes. Installation
should be performed by a qualied
plumber.
Big Dipper® IS System Plumbing Installation

©2015 Thermaco, Inc. All rights reserved • Patented/Patents Pending • Specications subject to change without notice
Thermaco, Inc. • 646 Greensboro St. • Asheboro, N. C. 27204-2548 • Phone (336) 629-4651 MNL-ISPS50000 10
50000 Series
1
1
2
2
3
3
4
4
A A
B B
C C
D D
THIS DRAWING CONTAINS PROPRIETARY AND PATENTED MATERIAL. THIS DRAWING MAY NOT BE REPRODUCED IN WHOLE OR PART WITHOUT
WRITTEN CONSENT FROM THERMACO, INC. POSSESSION OF THIS DRAWING DOES NOT CONSTITUTE THE RIGHT TO MANUFACTURE.
POSSESSION OF THIS DRAWING DOES CONSTITUTE AN IMPLIED NONDISCLOSURE AGREEMENT BETWEEN THERMACO, INC. AND THE HOLDER OF
THIS DRAWING. DO NOT DESTROY THIS DRAWING, IT IS THE SOLE PROPERTY OF THERMACO, INC. AND MUST BE RETURNED UPON REQUEST.
MATERIAL (UNLESS NOTED)
FINISH (UNLESS NOTED)
646 GREENSBORO STREET
PO BOX 2548, ASHEBORO, NC 27203
VOICE 336-629-4651 FAX 336-626-5739 Decimals
.XX +/- .03
.XXX +/- .015
Unless otherwise specified
Dimensions are in inches
Tolerances
Angular
+/- 1°
CHECKED SIZE REV. NO. DWG NO.
PART NO. C
SCALE RELEASE DATE SHEET OF
ENGINEERING
DRAWN DATE
THIRD ANGLE PRO JECTION
1
1
2
2
3
3
4
4
A A
B B
C C
D D
THIS DRAWING CONTAINS PROPRIETARY AND PATENTED MATERIAL. THIS DRAWING MAY NOT BE REPRODUCED IN WHOLE OR PART WITHOUT
WRITTEN CONSENT FROM THERMACO, INC. POSSESSION OF THIS DRAWING DOES NOT CONSTITUTE THE RIGHT TO MANUFACTURE.
POSSESSION OF THIS DRAWING DOES CONSTITUTE AN IMPLIED NONDISCLOSURE AGREEMENT BETWEEN THERMACO, INC. AND THE HOLDER OF
THIS DRAWING. DO NOT DESTROY THIS DRAWING, IT IS THE SOLE PROPERTY OF THERMACO, INC. AND MUST BE RETURNED UPON REQUEST.
MATERIAL (UNLESS NOTED)
FINISH (UNLESS NOTED)
646 GREENSBORO STREET
PO BOX 2548, ASHEBORO, NC 27203
VOICE 336-629-4651 FAX 336-626-5739 Decimals
.XX +/- .03
.XXX +/- .015
Unless otherwise specified
Dimensions are in inches
Tolerances
Angular
+/- 1°
CHECKED SIZE REV. NO. DWG NO.
PART NO. C
SCALE RELEASE DATE SHEET OF
ENGINEERING
DRAWN DATE
THIRD ANGLE PRO JECTION
Big Dipper® IS System
Plumbing Installation
The following drawings show proposed venting for Big Dipper units in various situations. Check state or local
plumbing code to determine proper installation for your facility.
Sites with Upstream Facility Vents
Sites using facility vents upstream of the Big Dipper unit do not require the use of a vessel vent. In this case,
the open inlet design of the unit works in conjunction with the facility vent and upstream P-trap to facilitate air
movement into and out of the interior grease interceptor air space and prevents air bound conditions from occur-
ing.
Sites without Upstream Facility Vents or Other Air Relief
Installations without Upstream Facility Vents or other Air Relief require the use of the vessel vent (also referred to
as a chamber vent) to prevent air bound conditions. Thermaco provides a 1” NPT connection by which this vent
may be connected to the unit and connected to the facility vent.
INCOMING FLOW
P-TRAP
FACILITY
VENT
FACILITY
VENT
OUTGOING FLOW
INCOMING FLOW
OUTGOING FLOW
VESSEL VENT
FACILITY
VENT
TIE-IN

©2015 Thermaco, Inc. All rights reserved • Patented/Patents Pending • Specications subject to change without notice
Thermaco, Inc. • 646 Greensboro St. • Asheboro, N. C. 27204-2548 • Phone (336) 629-4651 MNL-ISPS50000 11
50000 Series
Big Dipper® IS System
Plumbing Installation
Sometimes space restrictions require the installation of Big Dipper units in basement locations where signicant
head pressure becomes a factor. The Big Dipper®VFCA Vented Flow Control module provides an option for use
with installations where a signicant amount of head pressure is present (greater than 6 ft./1.95 m) or where ap-
plicable regulations require vented ow controls. A Vented Flow Control helps reduce problems associated with
high head pressure and helps slow the drainwater ow down. The VFCA kit contains an appropriate tting and
ow control orice.
VFCA-20 Vented Flow Control for W-200-IS
VFCA-25 Vented Flow Control for W-250-IS
VFCA-35 Vented Flow Control for W-350-IS
VFCA-50 Vented Flow Control for W-500-IS
1
1
2
2
3
3
4
4
A A
B B
C C
D D
THIS DRAWING CONTAINS PROPRIETARY AND PATENTED MATERIAL. THIS DRAWING MAY NOT BE REPRODUCED IN WHOLE OR PART WITHOUT
WRITTEN CONSENT FROM THERMACO, INC. POSSESSION OF THIS DRAWING DOES NOT CONSTITUTE THE RIGHT TO MANUFACTURE.
POSSESSION OF THIS DRAWING DOES CONSTITUTE AN IMPLIED NONDISCLOSURE AGREEMENT BETWEEN THERMACO, INC. AND THE HOLDER OF
THIS DRAWING. DO NOT DESTROY THIS DRAWING, IT IS THE SOLE PROPERTY OF THERMACO, INC. AND MUST BE RETURNED UPON REQUEST.
MATERIAL (UNLESS NOTED)
FINISH (UNLESS NOTED)
646 GREENSBORO STREET
PO BOX 2548, ASHEBORO, NC 27203
VOICE 336-629-4651 FAX 336-626-5739 Decimals
.XX +/- .03
.XXX +/- .015
Unless otherwise specified
Dimensions are in inches
Tolerances
Angular
+/- 1°
CHECKED SIZE REV. NO. DWG NO.
PART NO. C
SCALE RELEASE DATE SHEET OF
ENGINEERING
DRAWN DATE
THIRD ANGLE PRO JECTIO N
Installations where head
height is greater than 6 feet
(1.95 m)
Big Dipper®
IS Unit
NOTE: Drawing for reference only. Equipment must be installed in compliance with all applicable laws,
regulations and codes, including plumbing codes. Installation should be performed by a qualied plumber.
Drainage Piping
from Kitchen
Flow Control Vent/Air Intake
(Note: Flow Control Vent may be connected to
atmosphere vent, facility vent, or code-approved
air admittance valve.* To be installed above
sink ood rim.)
Outlet Vent
(Note: Vent may be facility vent
connection or code-approved air
admittance valve*)
Installation in high head height
locations requires removal of the
Internal Flow Control (small rub-
ber cap under no-hub coupling
over the Inlet).
*Air Admittance Valves are not permitted in
some locations such as Massachusetts. Check
local plumbing code to determine if they are
permitted by state or local plumbing code.

©2015 Thermaco, Inc. All rights reserved • Patented/Patents Pending • Specications subject to change without notice
Thermaco, Inc. • 646 Greensboro St. • Asheboro, N. C. 27204-2548 • Phone (336) 629-4651 MNL-ISPS50000 12
50000 Series
FLOW CONTROL VENT
MAY BE CONNECTED TO
ATMOSPHERE VENT,
FACILITY VENT, OR
CODE-APPROVED AIR
ADMITTANCE VALVE.*
TO BE INSTALLED
ABOVE SINK FLOOD
RIM.
*Air Admittance Valves are not
permitted in some locations such
as Massachusetts. Check local
plumbing code to determine if
they are permitted by state or local
plumbing code.
VFCA Vented Flow Control
Installation Instructions
IMPORTANT!
The ow control should be installed after the last xture as close as possible to the
under side of the lowest xture. If the ow control is installed more than 2 feet
below the lowest xture consult the manufacturer for a more restrictive disc.
Remove the rubber ow control from the Big Dipper system.
Note: This equipment must be installed to comply with all
applicable national, state, and local plumbing codes for your area.
Installation should only be performed by a qualied plumber.

©2015 Thermaco, Inc. All rights reserved • Patented/Patents Pending • Specications subject to change without notice
Thermaco, Inc. • 646 Greensboro St. • Asheboro, N. C. 27204-2548 • Phone (336) 629-4651 MNL-ISPS50000 13
50000 Series
1
1
2
2
3
3
4
4
A A
B B
C C
D D
THIS DRAWING CONTAINS PROPRIETARY AND PATENTED MATERIAL. THIS DRAWING MAY NOT BE REPRODUCED IN WHOLE OR PART WITHOUT
WRITTEN CONSENT FROM THERMACO, INC. POSSESSION OF THIS DRAWING DOES NOT CONSTITUTE THE RIGHT TO MANUFACTURE.
POSSESSION OF THIS DRAWING DOES CONSTITUTE AN IMPLIED NONDISCLOSURE AGREEMENT BETWEEN THERMACO, INC. AND THE HOLDER OF
THIS DRAWING. DO NOT DESTROY THIS DRAWING, IT IS THE SOLE PROPERTY OF THERMACO, INC. AND MUST BE RETURNED UPON REQUEST.
MATERIAL (UNLESS NOTED)
FINISH (UNLESS NOTED)
646 GREENSBORO STREET
PO BOX 2548, ASHEBORO, NC 27203
VOICE 336-629-4651 FAX 336-626-5739 Decimals
.XX +/- .03
.XXX +/- .015
Unless otherwise specified
Dimensions are in inches
Tolerances
Angular
+/- 1°
CHECKED SIZE REV. NO. DWG NO.
PART NO. C
SCALE RELEASE DATE SHEET OF
ENGINEERING
DRAWN DATE
THIRD ANGLE PR OJECTION
Big Dipper® IS System
Electrical Installation
Big Dipper® IS System Electrical Installation
Electrical Panel
(NOT SUPPLIED)
115 VAC Circuit,
From Ground Fault
Circuit Breaker
(NOT SUPPLIED)
*For 230 VAC Units use
230 VAC Circuit Socket Outlet
(NOT SUPPLIED)
Digital Control
Big Dipper Electrical Requirements
4.5 Amps @ 115 VAC 50/60Hz (520 Watts)
*For 230 VAC Units:
2.3 Amps @ 230 VAC 50/60Hz (520 Watts)
Note:
Digital Control Supplied with system.
Drawing for reference only. Equipment must be installed in compliance
with all applicable laws, regulations and codes, including electrical codes.
Installation should be performed by a qualied electrician.
Big Dipper Internal Strainer (IS) Models
Big Dipper Internal Strainer Series Models utilize one Push Button Digital
Time Controller. The Digital Control is located on the right side of the center
module (See Digital Control Operation Instructions). The Big Dipper should
only be plugged into a properly grounded 3-prong 115 VAC or 230 VAC
outlet. If possible, the power supply outlet for the Big Dipper should be
connected to an electrical circuit controlled by a ground fault circuit breaker.
One of the setting buttons should be illuminated to show the unit is
powered. If none of the setting buttons are illuminated, the unit is not
powered.
This Big Dipper unit is shipped from the Factory wired for Simultaneous
Operation. This means the Heater and Motor operate at the same time
under digital control. Continuous Heater Operation is where the Heater is
active at all times. To switch to alternative heating programming, please
contact a Thermaco representative for furher instructions.
Note: The Big Dipper unit will not operate when the lid is removed.

©2015 Thermaco, Inc. All rights reserved • Patented/Patents Pending • Specications subject to change without notice
Thermaco, Inc. • 646 Greensboro St. • Asheboro, N. C. 27204-2548 • Phone (336) 629-4651 MNL-ISPS50000 14
50000 Series
Big Dipper® IS System
Wiring Diagram
NOTE:
220-240V Units (International Units) have the
following wire color changes:
On the POWER SUPPLY CORD:
The Black Wire becomes Brown
The White Wire becomes Blue
The Green Wire becomes Yellow/Green
Wiring Diagram For Big Dipper Models
W-200-IS-SS Through W-500-IS-SS
1
1
2
2
3
3
4
4
A A
B B
MATERIAL (UNLESS NOTED)
FINISH (UNLESS NOTED)
646 GREENSBORO STREET
PO BOX 2548, ASHEBORO, NC 27203
VOICE 336-629-4651 FAX 336-626-5739 Decimals
.XX +/- .03
.XXX +/- .015
Unless otherwise specified
Dimensions are in inches
Tolerances
Angular
+/- 1°
CHECKED SIZE REV. NO. DWG NO.
PART NO.
SCALE RELEASE DATE SHEET OF
ENGINEERING
DRAWN DATE
THIRD ANGLE PROJECTION
B
1
2
3
BLACK
INTERLOCK
SWITCH
MOTOR
GREEN (GREEN/YELLOW)
GREEN
HEATER
GROUND WIRE ATTACHED
TO HEATER
THERMISTOR
BLACK (BROWN)
N
115
230
POWER SUPPLY CORD
RING TERMINALS TO GROUND STUD
ON MOTOR MOUNT BRACKET
WHITE (BLUE)
115 V INPUT TERMINAL
230V INPUT TERMINAL
WIRING DIAGRAM PUSH BUTTON
CONTROLLED BIG DIPPER
W SERIES S/N 30000 AND ABOVE
0WD-IS-PBC
03/17/09 1 1
NTS
B. KYLES 03/17/09
REVISION HISTORY
ZONE REV DESCRIPTION DATE APPROVED
BLACK
USER INTERFACE
MAIN BOARD
RIBBON CABLE

©2015 Thermaco, Inc. All rights reserved • Patented/Patents Pending • Specications subject to change without notice
Thermaco, Inc. • 646 Greensboro St. • Asheboro, N. C. 27204-2548 • Phone (336) 629-4651 MNL-ISPS50000 15
50000 Series
Big Dipper® IS System
Electrical Components
*Note:
230 VAC Units use M-58-230
and H-8-230
1
1
2
2
3
3
4
4
A A
B B
C C
D D
THIS DRAWING CONTAINS PROPRIETARY AND PATENTED MATERIAL. THIS DRAWING MAY NOT BE REPRODUCED IN WHOLE OR PART WITHOUT
WRITTEN CONSENT FROM THERMACO, INC. POSSESSION OF THIS DRAWING DOES NOT CONSTITUTE THE RIGHT TO MANUFACTURE.
POSSESSION OF THIS DRAWING DOES CONSTITUTE AN IMPLIED NONDISCLOSURE AGREEMENT BETWEEN THERMACO, INC. AND THE HOLDER OF
THIS DRAWING. DO NOT DESTROY THIS DRAWING, IT IS THE SOLE PROPERTY OF THERMACO, INC. AND MUST BE RETURNED UPON REQUEST.
MATERIAL (UNLESS NOTED)
FINISH (UNLESS NOTED)
646 GREENSBORO STREET
PO BOX 2548, ASHEBORO, NC 27203
VOICE 336-629-4651 FAX 336-626-5739 Decimals
.XX +/- .03
.XXX +/- .015
Unless otherwise specified
Dimensions are in inches
Tolerances
Angular
+/- 1°
CHECKED SIZE REV. NO. DWG NO.
PART NO. C
SCALE RELEASE DATE SHEET OF
ENGINEERING
DRAWN DATE
THIRD ANG LE PROJECT ION
Control Assembly
PCBA-2
Consisting of
1 - Printed Circuit Board
2 - User Interface Assembly
3 - Thermistor with Wiring
4 - Ribbon Cable with Connectors
4 - Ribbon Cable with Connectors
(Part of PCBA-2)
2 - User Interface
Assembly
(Part of PCBA-2)
3 - Thermistor with Wiring
(Part of PCBA-2)
Safety Switch
Part# MSS-7
Heater
Part# H-8*
Heater Gasket
Part# HTG-300
Motor
Part# M-58*

©2015 Thermaco, Inc. All rights reserved • Patented/Patents Pending • Specications subject to change without notice
Thermaco, Inc. • 646 Greensboro St. • Asheboro, N. C. 27204-2548 • Phone (336) 629-4651 MNL-ISPS50000 16
50000 Series
Big Dipper® IS System
Component Identication
Big Dipper® IS System Component Identication
1
1
2
2
3
3
4
4
A A
B B
C C
D D
THIS DRAWING CONTAINS PROPRIETARY AND PATENTED MATERIAL. THIS DRAWING MAY NOT BE REPRODUCED IN WHOLE OR PART WITHOUT
WRITTEN CONSENT FROM THERMACO, INC. POSSESSION OF THIS DRAWING DOES NOT CONSTITUTE THE RIGHT TO MANUFACTURE.
POSSESSION OF THIS DRAWING DOES CONSTITUTE AN IMPLIED NONDISCLOSURE AGREEMENT BETWEEN THERMACO, INC. AND THE HOLDER OF
THIS DRAWING. DO NOT DESTROY THIS DRAWING, IT IS THE SOLE PROPERTY OF THERMACO, INC. AND MUST BE RETURNED UPON REQUEST.
MATERIAL (UNLESS NOTED)
FINISH (UNLESS NOTED)
646 GREENSBORO STREET
PO BOX 2548, ASHEBORO, NC 27203
VOICE 336-629-4651 FAX 336-626-5739 Decimals
.XX +/- .03
.XXX +/- .015
Unless otherwise specified
Dimensions are in inches
Tolerances
Angular
+/- 1°
CHECKED SIZE REV. NO. DWG NO.
PART NO. C
SCALE RELEASE DATE SHEET OF
ENGINEERING
DRAWN DATE
THIRD ANG LE PROJEC TION
Skimming Wheel
Part# PDA-3
Wheel Axle
Part# WSS-2
Cotter Pin
Part# CP-1
Wheel Drive Sprocket
Part# WDS-3
Wheel Wiper
Assembly
WWBA-5
Metal Sump Cover
Part# MTC-50000
Motor/Timer Cover
Part# MTC-50000
Metal Lid Assembly
Part# MLWA-50000

©2015 Thermaco, Inc. All rights reserved • Patented/Patents Pending • Specications subject to change without notice
Thermaco, Inc. • 646 Greensboro St. • Asheboro, N. C. 27204-2548 • Phone (336) 629-4651 MNL-ISPS50000 17
50000 Series
1
1
2
2
3
3
4
4
A A
B B
C C
D D
THIS DRAWING CONTAINS PROPRIETARY AND PATENTED MATERIAL. THIS DRAWING MAY NOT BE REPRODUCED IN WHOLE OR PART WITHOUT
WRITTEN CONSENT FROM THERMACO, INC. POSSESSION OF THIS DRAWING DOES NOT CONSTITUTE THE RIGHT TO MANUFACTURE.
POSSESSION OF THIS DRAWING DOES CONSTITUTE AN IMPLIED NONDISCLOSURE AGREEMENT BETWEEN THERMACO, INC. AND THE HOLDER OF
THIS DRAWING. DO NOT DESTROY THIS DRAWING, IT IS THE SOLE PROPERTY OF THERMACO, INC. AND MUST BE RETURNED UPON REQUEST.
MATERIAL (UNLESS NOTED)
FINISH (UNLESS NOTED)
646 GREENSBORO STREET
PO BOX 2548, ASHEBORO, NC 27203
VOICE 336-629-4651 FAX 336-626-5739 Decimals
.XX +/- .03
.XXX +/- .015
Unless otherwise specified
Dimensions are in inches
Tolerances
Angular
+/- 1°
CHECKED SIZE REV. NO. DWG NO.
PART NO.
C
SCALE RELEASE DATE SHEET OF
ENGINEERING
DRAWN DATE
THIRD ANG LE PROJ ECTION
Big Dipper® IS System Replacement Parts
SOLIDS STRAINER BASKET
FOR MODEL# USE PART#
W-200-IS-SS THROUGH W-250-IS-SS ST-21
W-350-IS-SS & W-500-IS-SS ST-62
GREASE/OILS COLLECTION CONTAINER
FOR MODEL# USE PART#
W-200-IS-SS GC-50000
W-250-IS-SS/W-350-IS-SS GC-50000
W-500-IS GC-50000
USER INTERFACE (Under Cover)
FOR ALL MODELS USE PART# PCBA-2
(INCLUDES USER INTERFACE, RIBBON CABLE, PRINTED
CIRCUIT BOARD AND THERMISTOR)
Big Dipper® IS System Replacement Parts
NOT SHOWN:
MOTOR (1 per unit)
PART# M-58
M-58-230 in 230 VAC Units
HEATER (1 per unit)
PART# H-8
H-8-230 in 230 VAC Units
INTERNAL FLOW CONTROL (1 per unit)
PART# MFC-20 FOR W-200-IS
PART# MFC-25 FOR W-250-IS
PART# MFC-35 FOR W-350-IS
PART# MFC-50 FOR W-500-IS
LID GASKET
PART# RG-8
WHEEL WIPER ASSEMBLY (1 per unit)
PART# WWBA-5
WIPER BLADES (1 Pair)
PART# PB-3-PR
WHEEL DRIVE SPROCKET (1 per unit)
PART# WDS-3
SKIMMING WHEEL ASSEMBLY (1 per unit)
PART# PDA-3
SAFETY SWITCH
PART# MSS-7
HEATER GASKET
PART# HTG-300
SUMP HOSE
FOR ALL MODELS USE PART# SH-3
REPLACEMENT HOSES MUST BE SHORTENED
IN FIELD TO MATCH UNIT HEIGHT

©2015 Thermaco, Inc. All rights reserved • Patented/Patents Pending • Specications subject to change without notice
Thermaco, Inc. • 646 Greensboro St. • Asheboro, N. C. 27204-2548 • Phone (336) 629-4651 MNL-ISPS50000 18
50000 Series
Big Dipper® Limited Warranty & Remedy
Thermaco, Inc. warrants to the original user that the products manufactured by it delivered with this warranty shall
be free from material defects in workmanship and materials for a period of 12 months from the date of invoice to the
distributor (if sold by an authorized Thermaco distributor) or the date of invoice to the purchaser (if sold directly by
Thermaco, Inc.), but in no event longer than 15 months from date of shipment from Thermaco’s production facility.
Any claim must be made in writing to Thermaco at 646 Greensboro Street, Asheboro, NC 27203 promptly after
discovery of the defect and within the applicable warranty period. The product must be delivered, prepaid, to Ther-
maco, together with proof of purchase, the serial number from which the item was removed and a return authoriza-
tion number issued by Thermaco. If Thermaco determines upon examination that the component is defective and
that the warranty conditions are met, Thermaco’s sole obligation under this warranty, and the purchaser’s sole and
exclusive remedy, is the repair or replacement, at Thermaco’s option, of the defective component, including parts
and labor. The replacement will be furnished F.O.B. point of shipment. If Thermaco determines that the component
is not defective or that the other conditions of this warranty are not met, then any return of such part to the purchaser
shall be at purchaser’s cost.
This warranty shall not cover any defect in otherwise covered products resulting directly or indirectly from: (i) failure
to properly install, operate or maintain the product in accordance with Thermaco’s instructions and procedures,
including, without limitation, use in excess of rated ow, operation without digital control, improper electrical service,
use to remove emulsied fats and oils or use that fails to comply with applicable laws, regulations or codes; (ii) dam-
age in transit, handling or installation; (iii) modications, adjustments, repairs, or alterations made by unauthorized
persons; or (iv) other causes not arising out of defects in workmanship or materials. Thermaco shall not be respon-
sible for damage to products resulting from vault ooding, sewer line back-up, pumping or lift station failure, ambient
water ow or other sources of water damage. This warranty does not cover equipment or parts not manufactured
by Thermaco. Purchaser’s costs relating to any service, adjustment, removal, repair, packing, or otherwise incurred
with respect to the defect prior to submission for warranty are the responsibility of purchaser.
No distributor, sales person or other person is authorized to make any warranty statements on behalf of Thermaco
regarding Thermaco products other than as set forth in this warranty. This statement of warranty supersedes any
quote, brochure, or other statement or document with respect to warranty of Thermaco products.
EXCEPT AS EXPRESSLY SET FORTH ABOVE, THERMACO, INC. MAKES NO REPRESENTATIONS, WAR-
RANTIES OR GUARANTEES, EITHER EXPRESSED OR IMPLIED, INCLUDING, WITHOUT LIMITATION, AS TO
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WHETHER OR NOT THERMACO HAD
KNOWLEDGE OF PURCHASER’S PARTICULAR REQUIREMENTS OR NEEDS, OR WITH RESPECT TO ODOR
GENERATION OR OTHER INCIDENTALS RELATING TO USE OF THE PRODUCT.
The sole and exclusive remedy with respect to this warranty any other claim relating to defects or any other con-
dition or use of Thermaco products, however caused, and whether such claim is based upon warranty, contract,
tort, strict liability or any other theory, is LIMITED to the repair or replacement of the product, excluding labor or
any other cost to remove or install said the product or, at Thermaco’s option, repayment of the purchase price. IN
NO EVENT SHALL THERMACO, INC. BE LIABLE, WHETHER IN CONTRACT, WARRANTY, TORT (INCLUDING
NEGLIGENCE), STRICT LIABILITY, INDEMNITY OR ANY OTHER LEGAL THEORY, FOR INCIDENTAL OR CON-
SEQUENTIAL DAMAGES, OR FOR ANY OTHER LOSS OR COST OF A SIMILAR TYPE. UNDER NO CIRCUM-
STANCES WILL THE AGGREGATE LIABILITY OF THERMACO FOR ANY CAUSE OF ACTION RELATED TO THE
PRODUCTS COVERED HEREBY EXCEED THE NET PURCHASE PRICE RECEIVED BY THERMACO FOR THE
PRODUCTS. Any action or suit by purchaser against Thermaco relating to Thermaco products must be brought
within one (1) year of the date of the invoices referenced above. The exclusions and limitations set forth herein are
separate and independent from any remedies which purchaser may have hereunder and shall be given full force
and effect whether or not any or all such remedies shall be deemed to have failed of their essential purpose.
This manual suits for next models
4
Table of contents
Popular Water Filtration System manuals by other brands

Schenker
Schenker ZEN 50 Instructions for installation, use and maintenance manual

Eaton
Eaton DA/EDA 106 Operation and maintenance manual

Antunes
Antunes 9700913 installation instructions

AquaTools
AquaTools AT8710 owner's manual

EHEIM
EHEIM Classic 1500XL 2260 manual

Brita
Brita Redi-Twist USS-335 installation instructions

Vega
Vega VEGATRENN 151 operating instructions

Kobold
Kobold MFT operating instructions

Steinbach
Steinbach Speed Clean 75 Installation and operating instructions

Sub-Zero
Sub-Zero UC-15I quick start guide

aquanique
aquanique UF 3000 operating instructions

Watts
Watts Hydro-Safe Cube Max-CP1 Installation, operation and maintenance manual