thermastor Phoenix FOCUS II User manual

1
USEPHOENIX.COM |800-533-7533
The Phoenix FOCUS II is the new leader in performance,
convenience, portability, and safety for low profile air
movers.
Its ultra compact (21” X 8 1/4” footprint and 9 3/8” height)
make the Phoenix Focus II the most compact and portable
fan in its class. The rugged molded in handles give you
the solid control required when packing and unpacking air
movers.Its easy-winding cord wrap and multiple securement
options makes it a snap to prep for transport. Because of its
deeply-molded interlocking features, the Phoenix Focus II is
rock solid when stacked for transport.
With its Patent Pending design, and optimized outlet shape,
the Phoenix Focus II delivers airflow of over 1000 CFM. This
gives you high velocity air over a 50% larger area than other
low profile air movers.In addition, the Phoenix Focus II is
stable on all five sides for maximum flexibility to position
and direct the drying. Optional Focus Control Sticks, allows
unprecedented control with amazing flexibility.
The (patent pending), compact design of the Phoenix Focus
II allows four times the number of full-size axial air movers,
maximizing valuable storage space during transportation
and resulting in industry leading deployment on site.
All this performance is available with half the power draw. At
1.1 amps the Phoenix Focus II sets the industry standard for
drying per amp.
The Phoenix Focus II
• 1,015 CFM, 1.1 Amp
• Four air movers in the space of one
• Daisy chain up to 10 fans on a single 15 Amp circuit
• Dual stacking and cord wrap options
• All stainless steel fasteners
TS-1197
07/22 Rev. C
Phoenix Focus II
PN 4042250-01 (Red)
4042250-02 (Blue)
4042250-03 (Green)
Patent: thermastor.com/patents
Installation, Operation & Service Instructions
– READ AND SAVE THESE INSTRUCTIONS –
OWNER’S MANUAL
FOCUS II | AXIAL AIR MOVER
4201 LIEN RD. • MADISON, WI 53704
Specifications subject to change without notice.
Phoenix offers this
unit in both Red
and Blue

2
USEPHOENIX.COM |800-533-7533
Table of Contents
Introduction ................................................................................1
1. Specifications .....................................................................2
2. Important Safety Instructions ..........................................2
3. Operation.............................................................................2
3.1 Transporting the Phoenix Focus II.............................2
3.2 Electrical Requirements.............................................3
3.3 Focus Corners ..............................................................3
3.4 Resettable Circuit Breaker ........................................3
4. Maintenance.......................................................................3
4.1 Power Cord...................................................................3
4.2 Cleaning........................................................................3
4.3 Service ..........................................................................3
5. Wiring Diagram ..................................................................4
6. Service Parts.......................................................................5
7. Accessories .........................................................................5
Warranty..............................................................................6
Serial No.__________________________________
Purchase Date_____________________________
Dealer’s Name_____________________________
Read the operation and maintenance instructions
carefully before using this unit. Proper adherence to these
instructions is essential to obtain maximum benefit from
your Phoenix Focus II.
1 Specifications
Part No. 4042250-01 (Red)
4042250-02 (Blue)
4042250-03 (Green)
Power
110-120 VAC,
1.1 Amps
Blower 1,015 CFM
Cord Length 17ft 6in
Warranty One Year, 100% Parts and Labor
Dimensions Width 21”
Height 9 3/8”
Depth 8 1/4”
Weight 16 lbs.
2 Important Safety
Instructions
CAUTION: Risk of electric shock. Can cause injury or death
to reduce the risk of electric shock:
• Do not expose to standing water or rain.
• Unplug fan before servicing.
• Do not block air intake or outlet. One foot minimum
distance to obstructions.
Indoor use only
• Do not use as stool or bench.
• Do not operate with damaged cord or plug.
• Do not run cord under carpeting. Do not cover cord with
throw rugs, runners, or similar coverings. Do not route
cord under furniture or appliances. Arrange cord away
from traffic area and where it will not be tripped over.
WARNING: Not Suitable for use with Solid-State Speed
Controls
AVERTISSEMENT: Ne Convient Pas a Des Regulateurs De
Vitesse a Semi-Conducteurs
WARNING: DO NOT use or store this device in an area that is
accessible to children.
AVERTISSEMENT : NE PAS utiliser ou stocker cet appareil
dans une zone accessible aux enfants.
3 Operation
3.1 Transporting the Phoenix Focus II
The Phoenix Focus II is designed to be stacked vertically or
horizontally (“Bookshelf Stacking”) for transport.

3
USEPHOENIX.COM |800-533-7533
3.2 Electrical Requirements
The Phoenix Focus II can be plugged directly into any
standard wall receptacle. Without ducting, the Phoenix
Focus II will draw 1.1 amps at 110-120 VAC. Ducting will
reduce amp draw. Up to 10 Phoenix Focus IIs can be daisy
chained on a standard 15 amp branch circuit.
3.3 Focus Corners
The Phoenix Focus II is designed with four focus corners to
optimize drying over a wide surface area staring directly at
the front of the device.
3.4 Resettable Circuit Breaker
The 12 Amp thermal circuit breaker protects the unit and
devices connected receptacle.In case of a fault, the breaker
can be reset at the Phoenix Focus II control panel.
Use of multiple fans and any other connected devices must
be in accordance with the National Electric Code and any
additional codes or laws required by your local government.
IMPORTANT: Total amperage of the Phoenix Focus II plus all
devices plugged into its convenience receptacle is limited
by the onboard circuit breaker. Excessive current will cause
the circuit breaker to trip. This may occur instantly or after
a period of time depending on the operating conditions.
IMPORTANT: When the Phoenix Focus II is plugged into
a standard “powered” wall outlet the Phoenix Focus II is
electrically “HOT” and AC voltage is present.
4 Maintenance
WARNING: Disconnect the unit from power before servicing
or cleaning. Replace all safety grills after servicing or
cleaning.
4.1 Power Cord
Visually inspect cord and plug head before use.If there are
signs of damage or excessive wear, discontinue use until the
unit has been serviced.
4.2 Cleaning
The housing is made of durable and washable
polypropylene. When cleaning, the use of solvents is NOT
recommended.
When washing inside the unit, disconnect the unit from its
power source. Protect the switch, receptacle and circuit
breaker from water intrusion. Do not spray water or cleaning
solution at motor. If motor does get wet, allow motor to dry
completely before restarting. If fan is to be washed and not
used within 24 hours, allow fan to drip dry for 10 minutes
and then run for 5 minutes before storing.
IMPORTANT: Do NOT remove impeller blade from motor
assembly.Doing so can cause blade to become imbalanced
upon re-assembly.
4.3 Service
CAUTION: Servicing the Phoenix Focus II with its high voltage
circuitry presents a health hazard that could result in death,
serious bodily injury, and/or property damage. Disconnect
the appliance from the power supply before servicing. Only
qualified service people should service this unit.
CAUTION: If the supply cord or circuit breaker become
damaged, they must be replaced by the manufacturer, its
service agent or similarly qualified person in order to avoid a
hazard.

4
USEPHOENIX.COM |800-533-7533
5 Wiring Diagram
MOTOR 1
4043319
MOTOR 2
4043319
CAP 2
4042312
CAP 1
4042312
OUTLET
4042316
ILLUMINATED
SWITCH
4042315
CIRCUIT
BREAKER
4042314
GROUNDED
PLUG
4042313
WIRING
BLOCK
4042329
4042318
4042319
4042318
4042317
BLACK
18AWG
BROWN
18AWGBROWN
18AWG
WHITE
14AWG
BLACK
14AWG
WHITE
18AWG
BLACK
18AWG
BLUE
18AWG
BLUE
18AWG
3
2
1

5
USEPHOENIX.COM |800-533-7533
6 Service Parts
Part No. Description
4042304 FOOT,FOCUS II
4042305 GRILL,INTAKE,FOCUS II
4042306 GRILL,EXHAUST,FOCUS II
4042311 FAN,MOTOR,FOCUS II
4042312 CAPACITOR, MFD,500V,DRY,CLASS A
4042313 CORD,14/3,SJT,115V,PLUG&LMP
4042314 CIRCUIT BREAKER, A,SNAP-IN
4042315 SWITCH,ROCKER,SPST,ILLUMINATED
4042316 OUTLET,SNAP-IN,15A,120V
4042321 SCREW,PNCS,M5X12,SS
4042322 SCREW,PHS,M5X20,THREADFORM,SS
4042323 SCREW,PHCS,M4X12,SS
4042325 SCREW,PHCS,M4X10,SS,W/WASHER
7 Accessories
8” x 1/2” CPVC pipe (.625 OD) can be purchased from any
hardware store and can be used to allow for additional
drying positions.

6
USEPHOENIX.COM |800-533-7533
Warrantor:
Therma-Stor LLC
4201 Lien Rd
Madison, WI 53704
Telephone: 1-800-533-7533
Who Is Covered: This warranty extends only to the original end-user of the Focus II Fan, and may not be
assigned or transferred.
First Year Warranty: Therma-Stor Products warrants that, for one (1) year the Focus II Fan will operate
free from any defects in materials and workmanship, or Therma-Stor Products will, at its option, repair
or replace the defective part(s), free of any charge.
End-User Responsibilities: Warranty service must be performed by a Servicer authorized by Therma-Stor
Products. If the end-user is unable to locate or obtain warranty service from an authorized Servicer, he
should call Therma-Stor Products at the above number and ask for the Therma-Stor Products Service
Department, which will then arrange for covered warranty service. Warranty service will be performed
during normal working hours.
The end-user must present proof of purchase (lease) upon request, by use of the warranty card or
other reasonable and reliable means. The end-user is responsible for normal care. This warranty does
not cover any defect, malfunction, etc. resulting from misuse, abuse, lack of normal care, corrosion,
freezing, tampering, modification, unauthorized or improper repair or installation, accident, acts of
nature or any other cause beyond Therma-Stor Products’ reasonable control.
Limitations and Exclusions: If any Focus II Fan part is repaired or replaced, the new part shall be
warranted for only the remainder of the original warranty period applicable thereto (but all warranty
periods will be extended by the period of time, if any, that the Focus II Fan is out of service while
awaiting covered warranty service).
UPON THE EXPIRATION OF THE WRITTEN WARRANTY APPLICABLE TO THE Focus II Fan OR ANY PART
THEREOF, ALL OTHER WARRANTIES IMPLIED BY LAW, INCLUDING MERCHANTABILITY AND FITNESS
FOR A PARTICULAR PURPOSE, SHALL ALSO EXPIRE. ALL WARRANTIES MADE BY THERMA-STOR
PRODUCTS ARE SET FORTH HEREIN, AND NO CLAIM MAY BE MADE AGAINST THERMA-STOR PRODUCTS
BASED ON ANY ORAL WARRANTY. IN NO EVENT SHALL THERMA-STOR PRODUCTS, IN CONNECTION
WITH THE SALE, INSTALLATION, USE, REPAIR OR REPLACEMENT OF ANY Focus II Fan OR PART
THEREOF BE LIABLE UNDER ANY LEGAL THEORY FOR ANY SPECIAL, INDIRECT OR CONSEQUENTIAL
DAMAGES INCLUDING WITHOUT LIMITATION WATER DAMAGE (THE END-USER SHOULD TAKE
PRECAUTIONS AGAINST SAME), LOST PROFITS, DELAY, OR LOSS OF USE OR DAMAGE TO ANY REAL OR
PERSONAL PROPERTY.
Some states do not allow limitations on how long an implied warranty lasts, and some do not allow the
exclusion or limitation of incidental or consequential damages, so one or both of these limitations may
not apply to you.
Legal Rights: This warranty gives you specific legal rights, and you may also have other rights which vary
from state to state.
LIMITED WARRANTY
FOCUS II | LOW-PROFILE AIR MOVER
4201 LIEN RD. • MADISON, WI 53704
This manual suits for next models
3
Table of contents
Popular Air Handler manuals by other brands

Steffes
Steffes 5100 Series installation instructions

WALPOL
WALPOL WPZ-15E Installation and operating instructions

Blue Ridge
Blue Ridge KIT-BPK12 instruction manual

System air
System air VR-250 EH/B /3 User and maintenance instructions

ACPro
ACPro ACBU-06HRFN1-MV0W owner's manual

Lennox
Lennox MINIAIR Installation, operating and maintenance

NuAire
NuAire BPS V-CO Series installation manual

ICP
ICP FSA2X Series installation instructions

Salda
Salda RIRS 2500 HE EKO 3.0 QUICK LAUNCH GUIDE

GE
GE UUY24ZGDAA installation instructions

Zehnder Rittling
Zehnder Rittling ComfoAir Flex quick guide

WEGER WALTER GMBH
WEGER WALTER GMBH DIWER EVO Series Installation and operating manual