TA04494 C Page 3 of 4
STEP 5 (Option C -Electrical and Data)
Install the Voltage-divider (AFM-FAS-DIV) in the marked location
of the Floor Box (see Figures E.1 and E.2). Electrical power
will be on side where the 1/2 K.O. Plate or 10-Pin Modular
Connector Plate is mounted. The oval knockout on the other
side of the Voltage-divider should be removed to allow passage
of data cable. Make certain back edge of Voltage-divider is up
against inside vertical wall of Floor Box. The Device Panel (not
shown) will secure the Voltage-Divider in place.
Optional Wire Tunnel, AFM-FAS-WT (sold separately) can be
used to extend power to the other Device Panel on opposite
side of Floor Box (see Step 6).
STEP 6 (Option C-Electrical and Data)
Use Wire Tunnel, AFM-FAS-WT, under one of the following
conditions (see Figure G):
A. Extending power from one Device Panel to the other
Device Panel on other side of Floor Box.
B. Power Device is not accessible to 1/2 K.O. Plate or
10-Pin Modular Connector Plate because of the
Voltage-divider.
Remove the knockouts for the Wire Tunnel from the Device
Panels (see Figure F.1). Place electrical wires under Wire
Tunnel and install as shown in the figure. Secure in place
using the Device Panels (see Figure F.2).
Voltage Divider
(Sold Separately)
Mark Location for
Voltage Divider
Wire for
Power
Open K.O. for
low-voltage
cable
Low-Voltage
Cable to right
side of Wire
Tunnel
Power to left
side of Wire
Tunnel
FIG. E.1
FIG. E.1
FLOOR
BOX
FLOOR
BOX
FIG. F.1
FIG. F.2
Device Panel
Knock Out for
Wire Tunnel
Wire Tunnel
(Sold Separately)
Device Panel
Electrical Wires
Wire Tunnel
(Installed)
FLOOR
BOX
FLOOR
BOX