HERCULES®Low Voltage Contact Module
REASON TO USE A LOW VOLTAGE CONTACT MODULE:
This module is designed to interface any “120V output” to Air Conditioning/Heating “Low Voltage Control Inputs.”
Some Titan Controls®Controllers have “120V outputs” (eg. Apollo®series timer, Zephyr®series controllers, Eos®series controllers,
Atlas®series controllers … ). Should you need to control any SYSTEM whose inputs are not compatible with 120V output power,
you must use this module and refer to the connection diagram in the USER GUIDE of the SYSTEM you want to control.
ELECTRICAL SPECIFICATIONS:
Input: Low Power Coil - 120V AC 60HZ 0.4W
Output: Low Power Contact - 5A at 24V DC / 120V AC MAX.
• COMistherelayCOMMON
• N.O.istheNORMALLYOPENcontact
• N.C.istheNORMALLYCLOSEDcontact
MECHANICAL SPECIFICATIONS:
Plastic enclosure dimensions: length 2 inches, width 1.5 inch,
depth 1 inch, prong length 0.65 inch
Terminal: thick Brass, Tin Plated
Screws: 6-32, length 0.25 inch
(120V Prongs
connect to
the Coil)
120V
60HZ
Coil
N.O.
N.C.
COM
TYPICAL CONNECTION DIAGRAM:
Here is a typical connection diagram between Hercules®Low Voltage Contact Module and any Air Conditioning System. Main
power to the A/C System is not shown here, only A/C control input terminals need to be connected to the Hercules®Low Voltage
Contact Module.
SYSTEM
Eg. A/C System similar to
many mainstream models.
MODULE
Hercules®Low Voltage
Contact Module To
connect into Titan Controls®
Controller Outputs
N.O. COM N.C.
R
W
Y
G
LOW VOLTAGE CONTROL INPUTS ON TYPICAL HEATING OR COOLING SYSTEM:
When using the Hercules®
, power lines to the SYSTEM, it must be connected directly to the building electrical box. Control inputs are
normallyavailableonaSCREWTERMINALBLOCK,eachSYSTEMIN’sorOUT’sbeingidentiedbyaletter.Typically,SYSTEMOUT
LINESwillconnecttotheHercules®“COM”screwterminalandSYSTEMINLINEStotheHercules®‘’N.O.”screwterminal.
Typically, System OUTPUTS are connected to Hercules®“COM” screw terminal. Typically, System INPUTS are connected to Hercules®“N.O.” screw terminal.
OUTPUTS Description INPUTS Description
R24VacPowertoconnecttoany“INPUTS” Y or Y1 Single or First Stage Cooling
Rh 24Vac Power to connect to W / W1 / W2 / G Y2 Optional Second Stage Cooling
Rc 24Vac Power to connect to Y / Y1 / Y2 / G W or W1 Single or First Stage Heating
C24Vac Common, generally not used W2 Optional Second Stage Heating
Note:SYSTEMnormallyprovideseither“R”onlyor“Rhand
Rc”. Rh is for Heating inputs (W), Rc for cooling inputs (Y). GFan