manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. TJERNLUND
  6. •
  7. Blower
  8. •
  9. TJERNLUND VSUB12SS User manual

TJERNLUND VSUB12SS User manual

This manual suits for next models

1

Other TJERNLUND Blower manuals

TJERNLUND Hot Shot SB1 User manual

TJERNLUND

TJERNLUND Hot Shot SB1 User manual

TJERNLUND Hot Shot 950-9200 User manual

TJERNLUND

TJERNLUND Hot Shot 950-9200 User manual

TJERNLUND VSUB12R User manual

TJERNLUND

TJERNLUND VSUB12R User manual

TJERNLUND AUTO-DRAFT VSUB Series User manual

TJERNLUND

TJERNLUND AUTO-DRAFT VSUB Series User manual

TJERNLUND VSUB20R User manual

TJERNLUND

TJERNLUND VSUB20R User manual

TJERNLUND VSUB16R User manual

TJERNLUND

TJERNLUND VSUB16R User manual

TJERNLUND VSUB20SS User manual

TJERNLUND

TJERNLUND VSUB20SS User manual

Popular Blower manuals by other brands

Lithium Earthwise LB20024 Operator's manual

Lithium Earthwise

Lithium Earthwise LB20024 Operator's manual

EINHELL GE-CL 36 Li E Original operating instructions

EINHELL

EINHELL GE-CL 36 Li E Original operating instructions

EINHELL VENTURRO 18/210 operating instructions

EINHELL

EINHELL VENTURRO 18/210 operating instructions

Troy-Bilt 657 Operator's manual

Troy-Bilt

Troy-Bilt 657 Operator's manual

Weed Eater VS2000BV instruction manual

Weed Eater

Weed Eater VS2000BV instruction manual

KRAUSMANN U37020-00 Operation manual

KRAUSMANN

KRAUSMANN U37020-00 Operation manual

GreenWorks Pro BLB482 Operator's manual

GreenWorks Pro

GreenWorks Pro BLB482 Operator's manual

ARIETE 2768 manual

ARIETE

ARIETE 2768 manual

NuTone 331H user guide

NuTone

NuTone 331H user guide

GÜDE GLB 200 18 Li-Ion Translation of the original instructions

GÜDE

GÜDE GLB 200 18 Li-Ion Translation of the original instructions

I.VA.CO. SC Series Operating and maintenance manual

I.VA.CO.

I.VA.CO. SC Series Operating and maintenance manual

DeWalt DCE100 instruction manual

DeWalt

DeWalt DCE100 instruction manual

Ryobi RY40404VN Operator's manual

Ryobi

Ryobi RY40404VN Operator's manual

Becker SV 7.330 operating instructions

Becker

Becker SV 7.330 operating instructions

Metabo AG 18 Pro instructions

Metabo

Metabo AG 18 Pro instructions

Desa GA3650TB installation instructions

Desa

Desa GA3650TB installation instructions

Hanseatic BVN 2500 operating instructions

Hanseatic

Hanseatic BVN 2500 operating instructions

Echo Power Blower PB-230LN Operator's manual

Echo

Echo Power Blower PB-230LN Operator's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Description:
The VSUB12SS Variable Speed Universal Blower is suitable
for providing combustion air or sidewall or vertically venting
heating appliances, dryers and ovens. Suitable for use on con-
densing equipment. Can be installed indoors or outdoors.
Use with the CPC-3 Constant Pressure Controller, Closed
Loop VFD and TD-Series Pressure Transducer for an
Automatic-Variable Speed system which will modulate to
always deliver the perfect amount of draft or combustion air.
For an Adjustable-Fixed Speed system, use an Open Loop
VFD to manually adjust speed of the VSUB.
Housing Construction:
Constructed of 14-gauge, Type 316L stainless steel with con-
tinuous welds. The blower outlet rotates 180° for installation
flexibility. The motor chassis slides away from the housing on
polyethylene guides for easy motor and impeller access.
Impeller:
Backward inclined, Type 304 stainless steel, Class 1 impeller
is both dynamically and statically balanced with permanently
attached balancing weights.
Motor:
Three phase, 1 HP, 208-230/460 VAC, TEFC, EPACT High
Efficiency Rated, arctic-duty, thermal overload protected, per-
manently lubricated and sealed ball bearing.
Standard Equipment:
• 4” x 4” weatherproof junction box with 4’ conduit
• Square to round vent pipe adapter
• PSA-1 Fan Proving Switch
• FFP-1 Freeze and Fire Protection Limit
(FFP-1 For combustion air applications only!)
• Condensate drain kit
Optional Controls:
• CPC-3 Constant Pressure Controller
• IPS-1 Indoor Pressure Sensor decorative cover, fittings
• TD-2 Pressure Transducer (+0.15” to -0.60” w.c.)
For draft or “Sealed” (ducted sealed combustion air) sensing
• TD-3 Pressure Transducer (+0.10” to -0.10” w.c.)
For “Open” (room pressure) combustion air sensing
•VFD-Series Variable Frequency Drives
Temperature Rating:
U.S. and Canada 575°F / 300°C
Listings:
ETL # 56826
UL 378 - Draft Equipment / Variable Speed
UL 705 - Power Ventilators
CSA-CAN3-B255-M81*
*Not Listed for use on condensing equipment in Canada.
Warranty:
2 year mechanical
Tjernlund Products, Inc. • 1601 Ninth Street • White Bear Lake, MN 55110 • (651) 426-2993 • (800) 255-4208 • FAX (651) 426-9547 • www.tjernlund.com
P/N 8513038
MOUNTING
LOCATION (4)
D
TOP VIEW
B
ØA
ØF
E
C
G H
I
J
INCLUDED SQUARE
TO ROUND ADAPTER
O
L
END VIEW
M
N
K
P
Submitt
Submittal Dat
al Data Sheet
a Sheet
VSUB12SS V
VSUB12SS Variable S
ariable Speed Universal Blower
peed Universal Blower
Job Name:
Contractor:
Arch./Engr.:
Equipment Rep:
Prepared By:
Date:
Model VSUB12SS 208-230 Volt 460 Volt
Power hp 1 1
Amps A 3.2 - 3.0 1.5
Voltage VAC 3x208-230 3x460
Weight 205 Lbs. / 93 Kgs.
28 7/16"
15 7/16"
8 7/8"
21 13/16"
13 1/4"
18 7/8"
17 3/8"
35"
33"
11 15/16"
21 7/16"
10 1/8"
9 5/8"
12 1/2"
11 7/8"
VSUB12
O
N
M
L
K
J
I
H
G
F
E
D
C
B
A
P 6 5/16"
VSUB12SS