Description:
The VSUBR Series Variable Speed Universal Blowers (with
Ryton® coated impellers) are suitable for providing combustion
air or sidewall or vertically venting heating appliances, dryers
and ovens. Suitable for use on condensing equipment. Can be
installed indoors or outdoors.
Use with the CPC-3 Constant Pressure Controller, Closed
Loop VFD and TD-Series Pressure Transducer for an
Automatic-Variable Speed system which will modulate to
always deliver the perfect amount of draft or combustion air.
For an Adjustable-Fixed Speed system, use an Open Loop
VFD to manually adjust speed of the VSUB.
Housing Construction:
Constructed of 14-gauge, Type 316L stainless steel with con-
tinuous welds. The blower outlet rotates 180° for installation
flexibility. The motor chassis slides away from the housing on
polyethylene guides for easy motor and impeller access.
Impeller:
Backward inclined, Ryton® PPS coated for superior corrosion
resistance, Class 1 impeller is both dynamically and statically
balanced with permanently attached balancing weights.
Motor:
Three phase, 2 HP, 208-230/460 VAC, TEFC, EPACT High
Efficiency Rated, arctic-duty, thermal overload protected, per-
manently lubricated and sealed ball bearing.
Standard Equipment:
• 4” x 4” weatherproof junction box with 4’ conduit
• Square to round vent pipe adapter
• PSA-1 Fan Proving Switch
• FFP-1 Freeze and Fire Protection Limit
(FFP-1 For combustion air applications only!)
• Condensate drain kit
Optional Controls:
• CPC-3 Constant Pressure Controller
• IPS-1 Indoor Pressure Sensor decorative cover, fittings
• TD-2 Pressure Transducer (+0.15” to -0.60” w.c.)
For draft or “Sealed” (ducted sealed combustion air) sensing
• TD-3 Pressure Transducer (+0.10” to -0.10” w.c.)
For “Open” (room pressure) combustion air sensing
•VFD-Series Variable Frequency Drives
Temperature Rating:
U.S. and Canada 575°F / 300°C
Listings:
ETL # 56826
UL 378 - Draft Equipment / Variable Speed
UL 705 - Power Ventilators
CSA-CAN3-B255-M81*
*Not Listed for use on condensing equipment in Canada.
Warranty:
2 year mechanical
Tjernlund Products, Inc. • 1601 Ninth Street • White Bear Lake, MN 55110 • (651) 426-2993 • (800) 255-4208 • FAX (651) 426-9547 • www.tjernlund.com
P/N 8513032 REV 11/07
MOUNTING
LOCATION (4)
D
TOP VIEW
B
ØA
ØF
E
C
G H
I
J
INCLUDED SQUARE
TO ROUND ADAPTER
O
L
END VIEW
M
N
K
P
Submitt
Submittal Dat
al Data Sheet
a Sheet
VSUB16R V
VSUB16R Variable S
ariable Speed Universal Blower
peed Universal Blower
Job Name:
Contractor:
Arch./Engr.:
Equipment Rep:
Prepared By:
Date:
Model VSUB16R 208-230 Volt 460 Volt
Power hp 2 2
Amps A 6.0 - 5.6 2.8
Voltage VAC 3x208-230 3x460
Weight 285 Lbs. / 129 Kgs.
34 13/16"
18 7/8"
11 3/4"
26 13/16"
16"
24 3/4"
23 1/4"
43 11/16"
41 11/16"
15 7/8"
27 1/2"
13 5/16"
11 15/16"
14"
15 7/8"
VSUB16R
O
N
M
L
K
J
I
H
G
F
E
D
C
B
A
P 7 15/16"

Other TJERNLUND Blower manuals

TJERNLUND AUTO-DRAFT VSUB Series User manual

TJERNLUND

TJERNLUND AUTO-DRAFT VSUB Series User manual

TJERNLUND VSUB20SS User manual

TJERNLUND

TJERNLUND VSUB20SS User manual

TJERNLUND Hot Shot 950-9200 User manual

TJERNLUND

TJERNLUND Hot Shot 950-9200 User manual

TJERNLUND VSUB20R User manual

TJERNLUND

TJERNLUND VSUB20R User manual

TJERNLUND VSUB12SS User manual

TJERNLUND

TJERNLUND VSUB12SS User manual

TJERNLUND Hot Shot SB1 User manual

TJERNLUND

TJERNLUND Hot Shot SB1 User manual

TJERNLUND VSUB12R User manual

TJERNLUND

TJERNLUND VSUB12R User manual

Popular Blower manuals by other brands

Echo SHRED 'N' VAC ES-250 Operator's manual

Echo

Echo SHRED 'N' VAC ES-250 Operator's manual

GreenWorks BA24B210 Operator's manual

GreenWorks

GreenWorks BA24B210 Operator's manual

Makita DUB361 instruction manual

Makita

Makita DUB361 instruction manual

Shindaiwa EB240S Owner's/operator's manual

Shindaiwa

Shindaiwa EB240S Owner's/operator's manual

GGP ITALY SPA Blower Operator's manual

GGP ITALY SPA

GGP ITALY SPA Blower Operator's manual

Zeitler EZ.300 operating instructions

Zeitler

Zeitler EZ.300 operating instructions

PowerBoss apex 47 g instruction manual

PowerBoss

PowerBoss apex 47 g instruction manual

BONHOEFFER BON-P-BLV-26 instruction manual

BONHOEFFER

BONHOEFFER BON-P-BLV-26 instruction manual

Makita BUB142 instruction manual

Makita

Makita BUB142 instruction manual

Power works XB 40V BLP302 Operator's manual

Power works

Power works XB 40V BLP302 Operator's manual

Stiga BP 375 Operator's manual

Stiga

Stiga BP 375 Operator's manual

BOSSCO BPTEBV260 instruction manual

BOSSCO

BOSSCO BPTEBV260 instruction manual

Ebmpapst R3G190-AF50-01 operating instructions

Ebmpapst

Ebmpapst R3G190-AF50-01 operating instructions

Ebmpapst W4E315-CS22-71 operating instructions

Ebmpapst

Ebmpapst W4E315-CS22-71 operating instructions

nor-tec Blower Packs 380V installation manual

nor-tec

nor-tec Blower Packs 380V installation manual

Stihl BGA 60 instruction manual

Stihl

Stihl BGA 60 instruction manual

Ebmpapst D2E097-CB11-32 operating instructions

Ebmpapst

Ebmpapst D2E097-CB11-32 operating instructions

Viper Whiptail WT3SPD quick start guide

Viper

Viper Whiptail WT3SPD quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.