Simplified chart for log data
Revision #
Date
Contents
1.0
2021/3/31
Original

Page 3 of 9
1. Summary
The document is reference purpose for 800D of log data contents which consists of Code # and Opt #.
2. Simplified chart for log data
All of log data indicates contents as below. Log data indicates as follows and it can refer each content with Code #
and Opt #.
Example:
0456 03 3C 2021-03-18T11:16:18+09:00 00:00:01.500 Chime volume adjustment -60 dB
No. Code Opt Date Time Content
Please refer below chart for your reference.
Chart of Code and Opt
OPERATIONS
Code
Opt
Description (Code)
Description (opt)
Remark
00
-
Energized
Main power ON
Start unit working
01
Bit 0-6
CPU input port operation
-
For developer usage
02
00 ~60
(DEC),
FF(-∞)
Ducker depth adjustment
Attenuation (dB: negative
sign omitted)
02 40 = adjusting amount of
Ducker depth is -40 dB
03
00 ~60
(DEC),
FF(-∞)
Chime volume adjustment
Attenuation (dB: negative
sign omitted)
03 20 = adjusting amount of
Chime volume is -20 dB
04
00 ~60
(DEC),
FF(-∞)
Master volume adjustment
Attenuation (dB: negative
sign omitted)
04 10 = adjusting amount of
Master volume is -10 dB
05
00 ~60
(DEC),
FF(-∞)
Remote master volume
adjustment
Attenuation (dB: negative
sign omitted)
05 60 = adjusting amount of
Remote master volume is -60
dB
0A
00
Initialize network settings
00: fixed
Pressed reset button while press
power button and hold.
Insert AC cable while press
power button and hold.
0C
00 ~FF
HTTP Command reception
Refer “2-1 Command opt”
chart
0F
00
HTTP Command reception
(Factory inspection start)
00: fixed

Page 4 of 9
COMMAND DETAILS
Code
Opt
Description (Code)
Description (opt)
Remark
33
00
01
Command details
(Connection check)
00: False
01: True
34
00
01
Command details (Power
control)
00: OFF
01: ON
37
00 ~60
(DEC),
FF(-∞)
Command details
(Software master volume
control)
Attenuation (dB: negative
sign omitted)
38
bit 0
bit 1-7
Command details (Switch
the mode)
0: Standard Control mode
1: Manual Control mode
0: fixed
39
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
Command details (Muting
the audio input)
0: Unmute, 1: Mute
For Audio Input 1
For Audio Input 2
For Audio Input 3
For Audio Input 4
For Audio Input 5
For Audio Input 6
For Input Module 1
For Input Module 2
Opt number is necessary to
calculate from Hexadecimal to
Binary number.
39 05 = 39 00000101
Audio Input 1 and 3 are muting
and less of inputs are unmuting.
3A
0
1
Command details (Release
mute)
0: False
1: True
3E
bit 0-1
bit 2-3
bit 4-5
bit 6-7
Command details (Set the
parameters of the EQ)
EQ1Type(00:Not used、
01:LPF、10:HPF、11:
PEQ)
EQ2Type(00:Not used、
01:LPF、10:HPF、11:
PEQ)
EQ3Type(00:Not used、
01:LPF、10:HPF、11:
PEQ)
00: Fixed
Opt number is necessary to
calculate from Hexadecimal to
Binary number.
3E B4 = 3E 00011110
EQ1: HPF
EQ2: PEQ
EQ3: LPF
40
bit 0-3
bit 4
bit 5-7
Command details (Set the
priority broadcast 1)
Priority (Emergency: 0,
Priority 1 to 8, Not priority
(normal): 9, Invalid: F).
Chime Not used:0, Used:1.
0: Fixed
Opt number is necessary to
calculate from Hexadecimal to
Binary number.
02 : 00010010
Priority 2 broadcasting with
chime.

Page 5 of 9
41
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
Command details (Set the
priority broadcast 2)
0: Unmute, 1: Mute
For Audio Input 1
For Audio Input 2
For Audio Input 3
For Audio Input 4
For Audio Input 5
For Audio Input 6
For Input Module 1
For Input Module 2
Opt number is necessary to
calculate from Hexadecimal to
Binary number.
92 : 10010010
Audio Input 2, 5 and Module 2
are muted.
44
00: OFF
01: ON
Command details (Set the
Network Setting)
Obtain IP address
automatically (0: OFF, 1:
ON)
ACTION
Code
Opt
Description (Code)
Description (opt)
Remark
60
00
01
The power status has
been changed
00: Standby
01: ON
61
-
CPU output port has been
changed
-
62
00
01
Operation mode
00: Normal Mode
01: Factory Inspection
Mode
63
00
01
Mode of Power amplifier
module has been changed
00: SPAN Other mode
01: SPAM standby mode
64
bit 0-3
bit 4
bit 5-7
Priority broadcast has
been controlled
Priority (Emergency: 0,
Priority 1 to 8, Not priority
(normal): 9, Invalid: F).
Chime Not used:1, Used:2.
0: Fixed
Opt number is necessary to
calculate from Hexadecimal to
Binary number.
09 : 00001001
Priority 1 broadcasting without
chime.
65
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
The audio input has been
muted
0: Unmute, 1: Mute
For Audio Input 1
For Audio Input 2
For Audio Input 3
For Audio Input 4
For Audio Input 5
For Audio Input 6
For Input Module 1
For Input Module 2
Opt number is necessary to
calculate from Hexadecimal to
Binary number.
00 : 00000000
All of audio input is unmuted.
09: 00001001
Audio input 1 and 4 are muted.

Page 6 of 9
67
00 ~60
(DEC),
FF(-∞)
Total Volume value has
been adjusted
Attenuation (dB: negative
sign omitted)
67 30 = Total volume amount is
-30 dB
68
00
01
The output impedance has
been changed
00: Low-z mode
01: Hi-z mode
69
00
01
Auto Sync
00: WebSocket end
01: WebSocket start
PROTOCOL RESPONSE
Code
Opt
Description (Code)
Description (opt)
Remark
90
00 ~FF
Protocol response (200)
Refer “2-1 Command opt”
chart
Command request is accepted
92
00 ~FF
Protocol response (202)
Refer “2-1 Command opt”
chart
Command request is accepted
and in progress for processing
94
00 ~FF
Protocol response (400)
Refer “2-1 Command opt”
chart
Command message has an
error
96
00 ~FF
Protocol response (403)
Refer “2-1 Command opt”
chart
Identification is necessary
97
00 ~FF
Protocol response (404)
Refer “2-1 Command opt”
chart
No found next processing step.
98
00 ~FF
Protocol response (405)
Refer “2-1 Command opt”
chart
Not supporting method
99
00 ~FF
Protocol response (500)
Refer “2-1 Command opt”
chart
Internal Server error
ERROR
Code
Opt
Description (Code)
Description (opt)
Remark
E0
bit 0
bit 1
bit 2
bit 3-7
Power amplifier module
error
Thermal Protection
0:Normal、1:protection
Over Current
0:Normal、1:Protection
Status Unmatched
0:Normal, 1:Unmatched
0: Fixed
Opt number is necessary to
calculate from Hexadecimal to
Binary number.
E0 02 : E0 00000010
Over current has been
protected.
E2
00 ~FF
WDT error
Second(s)
If counter will be reset or not
record more than 5 seconds,
E5
00
Firmware update failure
00: fixed
E6
00
History save failure
00: fixed
E7
00
10
20
30
Setting error has been
occurred
00:Management area
10:Unit setting
20:Network setting
30:Unit Status

Page 7 of 9
E8
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6-7
Priority broadcast setting
error
Abnormal status
(0:Normal、1:Abnormal)
Detect Audio Input 1
(0:Normal、1:Abnormal)
Detect Audio Input 2
(0:Normal、1:Abnormal)
Detect Module 1
(0:Normal、1:Abnormal)
Detect Module 2
(0:Normal、1:Abnormal)
Emergency Broadcast
(0:Normal、1:Abnormal)
0: Fixed
Opt number is necessary to
calculate from Hexadecimal to
Binary number
E8 20 = E8 00100000
Emergency Broadcast setting
has error
NOTIFICATION
Code
Opt
Description (Code)
Description (opt)
Remark
F0
00 ~FF
Additional time
information (High)
This information for clockwise
and use internally.
F1
00 ~FF
Additional time
information (Low)
This information for clockwise
and use internally.
F2
00
Ignore priority broadcast
activation
00: Fixed.
While higher priority
broadcasting is working, unit
receive lower priority activating
instruction from contact or
audio signal.
F4
1 ~31
Date info
MM
F5
0 ~23
Time info
HH
F6
-48 ~
52
Time zone info
It is UTC base and EST: -5:00 :
opt amount indicates “-20” (-5×
4).

Page 8 of 9
2-1 Command opt
Opt number is necessary to convert from Hexadecimal to Binary number and 2 contents are including. First 3
digits is action and last 5 digits is contents.
Example; Log data indicates Code is 90 and opt is 44. Opt 44 converts to Binary number : 01000100
It divides first 3 digits “010”and less 5 digits “00100”. Refer below table to pick up log info,
Code 90 opt 44 is Protocol response (200) PUT Power.
Action
Binary #
API
Last 3 digits
000
GET
001
POST
010
PUT
011
DELETE
100
HEAD
101
OPTIONS
110
TRACE
111
CONNECT
Contents
Binary #
API
Last 5 digits
00000
Login
00001
Logout
00010
Equipment-info
00011
Connection-check
00100
Power
00101
Status
00110
AGC
00111
Volume
01000
Manual
01001
Mute start
01010
Mute stop
01011
Zero start
01100
Zero stop
01101
Date time zone
01110
EQ
01111
FBS
10000
Setting
10001
Input priority
10010
Bus
10011
Input priority-edit
10100
Network

Page 9 of 9
10101
Firmware
10110
Log
10111
Reset
11000
Soft volume memory
11001
Default-priority
11010
Start auto sync
11011
Auto sync
11100
Close auto sync
11101
Flash
11110
Test
11111
SPI flash
01110
EQ
01111
FBS
10000
Setting
10001
Input priority
10010
Bus
10011
Input priority-edit
10100
Network
10101
Firmware
10110
Log
10111
Reset
11000
Soft volume memory
11001
Default-priority
11010
Start auto sync
11011
Auto sync
11100
Close auto sync
11101
Flash
11110
Test
11111
SPI flash