Installation Instructions
Before Installing
Check unit for damage. Air conditioners are inspected
at the factory. If any damage has occurred, save the
packaging and file a claim with the delivering carrier
within fifteen working days. TOPAZ requires minimal
installation. Plug unit in proper NE A receptacle, and
it begins to cool immediately.
Electrical Supply
Determine the proper power by checking unit’s rating
plate. Refer to the Specifications section on page 3 for
voltage and fuse requirements. Use wall outlets and
receptacles found in the table below.
Operating unit on improper voltages voids the warranty.
Note: Extension cords may be used if rated at a
minimum 120-V, 20-amp for models TZ-12B
and TZ-18B. Extension cords must be fitted with
the appropriate grounding-type attachment plug.
Use 25-ft maximum length extension.
Unit Operation
Fan
1. Place unit on level surface.
2. Plug unit in.
3. Press the COOL/FAN on switch for continuous fan
operation. The cooling circuit will cycle on and off.
Press the COOL/FAN AUTO switch for cycling the
fan operating on and off with the cooling circuit.
Cooling Cycle
1. Set the desired temperature by adjusting the
COOL-COOLER dial from 68º-115º
Note: Wait 4 minutes between turning cooling mode
off and on.
reventative Maintenance
TOPAZ provides maximum performance and reliability
with minimum maintenance. The refrigeration and
electrical circuits of the system should be serviced by
qualified technicians only. To prolong the life of the
unit, perform regular maintenance as described below.
Blower Motors
The blower motor has permanently lubricated ball
bearings and requires no relubrication. Inspect fan for
buildup of dirt on blades. Clean as needed.
Filters
Dirty filters cause the unit to operate at reduced
efficiences. Inspect both evaporator and condenser air
filters every six weeks, or more, if operating in a dirty
environment. The filters are located behind the air inlet
grilles on the front and back of the unit. Remove the
grilles by pulling the bottom of each grill outward
using the handle located near the bottom of the panels.
When the bottom of the panel is clear of the unit
casing, it can be lowered several inches, which will
disengage tabs at the top of the panel from slots in the
casing. At this point the panel can be removed. The
filters are visible at this point but still retained by four
clips. Use a screwdriver to loosen the screws securing
the clip, so the clips rotate downward, clear of the filter.
Remove the filter and replace with a clean one
reversing the above procedure.
Do not operate the unit without filters. Doing so will
cause the coil to become dirty faster, and may require
professional cleaning.
Coil Cleaning
Evaporator and condenser coils can be cleaned using
compressed air.
Condensate ump
1. Disconnect unit from power source before
attempting to service or remove any component.
2. Be sure floats move freely. Clean as necessary.
3. Remove floats and check for obstructions. Clean as
needed.
4. Clean tank with warm water and mild soap when
mineral deposits are visible.
TOPAZ™Owner’s Manual
Model Plug Configuration Receptacle
TZ-12B
TZ-18B
115V
15A/115V
NE A 5-15P
NE A 5-15R