Owner’s Manual
Model Number
RM5RK
RM5CB
RM5CS
RM 10 RK
RM 10 CB
RM 10 CS
RM 15 RK
RM 15 CB
RM 15 CS
Power Conditioners
Audio / Video Power Isolation Units
Rack Mount / Consumer Series
Maximum Available
Output Current
5A
10A
15A
Output
Connector
6 outlets
Medical-grade
15A
8 outlets
Medical-grade
15A
10 outlets
Medical-grade
15A
Input
Voltage
120VAC
120VAC
120VAC
19” Pro Series Rack Mount (RK) Faceplate
17” Consumer Series (C) Faceplate
Available in Black (B) and Silver (S) Colours
™
Output
Voltage
120VAC
120VAC
120VAC
Toroidal
Isolation
Power
Conditioning

Important Safety Instructions
CAUTION!
CAUTION!
CAUTION!
CAUTION!
To reduce the risk of electric shock and fire, do not remove the cover of this device. There
are no user serviceable parts inside. Please refer all servicing to licensed service technicians.
The international symbol of a lightning bolt inside a triangle is intended to alert the user to
uninsulated “dangerous voltage” within the device’s enclosure. The international symbol of an
exclamation point inside a triangle is intended to alert the user to the presence of important
operating, maintenance and servicing information in the manual accompanying the device.
To prevent electrical shock, match wide blade of plug to wide slot, fully insert.
To reduce the risk of electrical shock, do not expose this equipment to rain or moisture.
1. Read Instructions—All safety and operating instructions
should be read before operating the device.
2. Retain Instructions—The safety and operating
instructions should be retained for future reference.
3. Heed Warnings—All warnings on the device and in the
operating instructions should be adhered to.
4. Follow Instructions—All operating and safety instructions
should be followed.
5. Water & Moisture—The device should never be used in,
on or near water for risk of fatal shock.
6. Ventilation—The device should always be located in such
a way that it maintains proper ventilation. It should never
be placed in a built-in installation or anywhere that may
impede the flow of air through its ventilation slots.
7. Heat—Never locate the device near heat sources such as
radiators, floor registers, stoves or other heat-generating
devices.
8. Power Cord Protection—Power cables should be routed
so they are not likely to be stepped on or crushed by items
placed on them or against them. Special attention should
be paid to areas where the plug enters a socket or fused
strip and where the cord exits the device.
9. Periods Of Non-Use—The device should be unplugged
when not being used for extended periods.
10. Dangerous Entry—Care should be taken that no foreign
objects or liquids fall or are spilled inside the device.
11. Damage Requiring Service—The device should be
serviced by licensed technicians when:
• The plug or power supply cord has been damaged.
• Objects have fallen or liquid has spilled inside the device.
• The device has been exposed to moisture.
• The device does not appear to be operating properly or
exhibits a marked change in performance.
• The device has been dropped or the enclosure becomes
damaged.
12. Service—The device should always be serviced by
licensed technicians. Only replacement parts specified by
the manufacturer should be used. The use of unauthorized
substitutions may result in fire, shock, or other hazards.
13. Do not position the equipment so that it is difficult to
operate the disconnecting device (power cord).
14. If the equipment is used in a manner not specified by
the manufacturer, the protection provided by the
equipment may be impaired.
16. Some units can be very heavy, please use
safe practices when lifting.
15. It is recommended that component power switch
remains in the “off” position when connecting or
disconnecting equipment from a Torus Power unit.
CAUTION
³18 kg (39.7 lb) ³32 kg (70.5 lb) ³55 kg (121.2 lb)
www.TorusPower.com
Owner’s Manual Audio / Video Power Isolation Units Single 5A, 10A, 15A Rack Mount / Consumer 08/12Power Conditioners
™
REV.08/25/2012

Torus Power PIUs (Power Isolation Units) combines the best
surge suppression with unique toroidal transformer
technologies from PLITRON to provide the ultimate in AC
power conditioning and protection for sensitive audio and
video equipment applications.
PIUs use ZeroSurge patented series-mode surge removal
filters to absorb dangerous voltage surges and safely dissipate
them without using failure-prone MOVs (metal oxide
varistors). Also, unlike MOV-based protection, voltage surges
are not shunted to ground.
Isolation is combined with proven proprietary technologies
from PLITRON in the over-sized toroidal transformer. NBT
works as a low pass filter using the controlled leakage
inductance and capacitances within the transformer to cancel
common mode and differential mode noise. LoNo technology
has been used for years by high-end audio companies who
demand silent transformers. Imin technology reduces inrush
currents. UST provides additional common mode filtering
using a highly efficient Faraday screen.
Low-impedance output with balanced high-power primary
input provides the most unconstrained, yet protected, energy
source available to your equipment.
â
Description
Please keep the original shipping box and all packing material.
This will ensure the PIU is protected in future transport.
In the unlikely event you have a problem and must return it for
service you must use the original packing material.
Ship the PIU only in the original packing material, as the unit is
not insurable by carriers otherwise.
Shipping Carton & Packing Material
Torus Power PIUs are extremely efficient devices, however,
they are also very high-power devices, and must be
adequately cooled.
Do not install the PIU directly above heat-generating
equipment.
Maintain at least 15cm behind the PIU for adequate wiring
space.
PIUs have ventilation slots on the base, side panels and the
cover. Maintain at least 2.5cm distance from each of these
surfaces to anything else. Should your installation conditions
be constricted, additional forced air-cooling may be
necessary.
Placement & Ventilation
Torus Power products are warranted to be free from
manufacturing defects for five years from the original date of
sale. This includes parts, labour and return shipping to the
first registered owner and all subsequent registered owners.
Warranty coverage is extended to applicable products
registered or having proof-of-purchase (sales invoice, etc.).
In the event of a defect or malfunction, Torus Power will
remedy the problem by repair or replacement, as we deem
necessary, to restore the product to full performance.
This warranty is considered void if the defect, malfunction or
failure of the product or any component part was caused by
damage (not resulting from a defect or malfunction) or abuse
while in the possession of the customer. Failure to fully comply
with Torus Power operating instructions, voids the warranty.
Warranty
www.TorusPower.com
Owner’s Manual Audio / Video Power Isolation Units Single 5A, 10A, 15A Rack Mount / Consumer 08/12Power Conditioners
™
REV.08/25/2012

Front Panel Layout
Electrical Specifications
Input Voltage
Nominal
VAC120 , 60Hz
Range +/- 10% voltage
57-63Hz
Model
Number
RM 5 RK
RM5CB
RM5CS
RM 10 RK
RM 10 CB
RM 10 CS
RM 15 RK
RM 15 CB
RM 15 CS
Single 5A, 10A, 15A
19” Pro Series Rack Mount Faceplate
Model Numbers RM 5 RK,
RM 10 RK and RM 15 RK
Input
Current
Limiting
5A
Circuit Breaker
Front Panel
10A
Circuit Breaker
Front Panel
16A
Circuit Breaker
Front Panel
Maximum
Available
Output Current
(see note above)
5A
10A
15A
½ cycle
50A
100A
300A
Load Current Capability
1 second
40A
80A
150A
10 seconds
15A
30A
75A
Input Power Switch / Circuit Breaker
Single 5A, 10A, 15A
17” Consumer Series Faceplate
Model Numbers RM 5 CB, RM 5 CS,
RM 10 CB, RM 10 CS, RM 15 CB and RM 15 CS
The front panel power switch is also
a circuit breaker. As a circuit breaker,
it prevents excessive current from
entering the PIU.
When the power is on, the switch is
illuminated. When the breaker trips,
the switch returns to its “off”
position.
Circuit Protection
Torus PIUs will shut-down if internal
unit temperature reaches excessive
levels.
Thermal Protection
Per UL, CSA and National Electrical
codes, devices with line cords and
plugs must not consume more than
80% of a branch circuit’s rating.
While Torus Power Isolation Units
are designed to handle well beyond
these limits, they must be marked
with a maximum input current that
satisfies the requirements.
Input Current Rating
www.TorusPower.com
Owner’s Manual Audio / Video Power Isolation Units Single 5A, 10A, 15A Rack Mount / Consumer 08/12Power Conditioners
™
REV.08/25/2012
Output Voltage
Nominal
VAC120

Mechanical Specifications
Weight
13.5 kg
13.0 kg
16.4 kg
15.7 kg
20.9 kg
20.2 kg
Size, mm
(wxdxh)
483 x 268 x 102
432 x 268 x 105
483 x 268 x 102
432 x 268 x 105
483 x 268 x 102
432 x 268 x 105
Model Number
RM 5 RK
RM 5 CB
RM 5 CS
RM 10 RK
RM 10 CB
RM 10 CS
RM 15 RK
RM 15 CB
RM 15 CS
Height includes rubber mounting feet.
Input
Connector
(Rear Panel)
IEC 15A
Inlet
Line Cord
(included)
N5/15, 14AWG
C13, 15A/125V
Suggested
Wall
Receptacle
Standard outlet
NEMA 5-15R
15A - 125V
Output
Connector
(Rear Panel)
Qty 3 (6 outlets)
Medical-grade
15A
Qty 4 (8 outlets)
Medical-grade
15A
Qty 5 (10 outlets)
Medical-grade
15A
Torus PIUs are high-power products.
The outlets they are plugged into
should be sufficient to provide the
current to operate them without
tripping circuit breakers within your
junction panel.
Rear Panel Layout Wall Receptacles
Accessory
Ground Stud
Power Inlet
Power Outlet
Rubber Mounting Feet
(may be removed if rack mounting)
Line Cords
Standard 15A 120V
IEC C13
5 15P, Straight Blade, 2 pole,
3-wire grounding, 15A 125V
3 x 14AWG
2.5 m
Equipment end:
Plug: -
Cord:
Length:
Product Label
Warning Label
Single 5A
Model Numbers RM 5 RK,
RM 5 CB and RM 5 CS
Toronto,Canada
www.TorusPower.com
Model Number
Input
Output
Part Number
Serial Number
RM 2.5
120VAC 60Hz, 2.5A max
120V 2.5A max
PA-10201-00
0001
WARNING
DISCONNECT POWER
BEFORE WORKING WITHIN
www.TorusPower.com
Owner’s Manual Audio / Video Power Isolation Units Single 5A, 10A, 15A Rack Mount / Consumer 08/12Power Conditioners
™
REV.08/25/2012
Single 10A
Model Numbers RM 10 RK,
RM 10 CB and RM 10 CS
Toronto,Canada
www.TorusPower.com
Model Number
Input
Output
Part Number
Serial Number
RM 2.5
120VAC 60Hz, 2.5A max
120V 2.5A max
PA-10201-00
0001
WARNING
DISCONNECT POWER
BEFORE WORKING WITHIN
Toronto,Canada
www.TorusPower.com
Model Number
Input
Output
Part Number
Serial Number
RM 2.5
120VAC 60Hz, 2.5A max
120V 2.5A max
PA-10201-00
0001
WARNING
DISCONNECT POWER
BEFORE WORKING WITHIN
Toronto,Canada
www.TorusPower.com
Model Number
Input
Output
Part Number
Serial Number
RM 2.5
120VAC 60Hz, 2.5A max
120V 2.5A max
PA-10201-00
0001
WARNING
DISCONNECT POWER
BEFORE WORKING WITHIN
Single 15A
Model Numbers RM 15 RK,
RM 15 CB and RM 15 CS

Specifications subject to change without notice.
© Torus Power 2012
www.TorusPower.com
08/12
Torus Power
#8 601 Magnetic Drive
Toronto, ON M3J 3J2
Canada
416-667-9914
™
Torus Power products are
marketed worldwide through
Plitron Manufacturing Inc.
Phone: 416-667-9914
Toll free: 1-800-754-8766
Fax: 416-667-8928
For sales contact:
Technical inquiries:
Phone: 416-667-9914
REV.08/25/2012
This manual suits for next models
8
Table of contents
Other Torus Power AC Power Distribution manuals

Torus Power
Torus Power Pro Series User manual

Torus Power
Torus Power RM 16 INT’L UK User manual

Torus Power
Torus Power AVR Series User manual

Torus Power
Torus Power RM 2.5 User manual

Torus Power
Torus Power IS 5 RK User manual

Torus Power
Torus Power RM 20 BAL RK User manual

Torus Power
Torus Power IS 8 UK User manual

Torus Power
Torus Power RM 15 PLUS RK User manual

Torus Power
Torus Power PowerBlock Series User manual

Torus Power
Torus Power IS 4 CE RK User manual