SMART 43D
Operational modes: Continuous-Heating,
Stand-by, Boost, Timer12, Timer24.
•“Continuous-Heating”:
•“Boost” mode:
•“Timer12” and “Timer 24” mode:
•“Stand-by” mode:
is an electronic control for towel
radiators.
There are ten different types of available
resistances: from 100W to 1000W.
the electronic control
activates the heating element and remains
active until the user decides to set the device to
“Stand-by” mode, the maximum temperature
available is 43°C.
the thermostat feeds the
heating element at the maximum power for two
hours. At the end of the two hours, the control
goes back to “Stand-by” mode.
the
electronic control activates the “Boost” function
for two hours. At the end of the two hours the
control reverts to “Stand-by” mode for either 10
or 22 hours (the user has the option to preset it),
after which the thermostat repeats the
function for two hours. This sequence is
repeated cyclically.
by activating this function,
the device sets to stand-by, the heating element
is then deactivated.
“Boost”
SMART 43D is a certified product:
SMART 43D complies to the following directives:
.
-EN 60335-1:2012+A11:2014 -EN 60335-2-30:2009+A11:2012
-EN 60335-2-43:2003+A1:2006+A2:2008
-EN 61000-3-2:2014 -EN61000-3-3:2013 -EN 62233:2008
-EN 55014-1:2006+A1:2009+A2:2011 -EN 55014-2:1997+A1:2001+A2:2008
-Eco-design Directive for Energy-using Products, 2005/32/EC (<0,5W)
Aveilable color: White.
Chrome.
TOWELRADS
Towelrads Lrd.
Unit4e5,Maidenhead Trade Park, Priors Way, wwww.towelrads.comMaidenhead, Berkshire SL6 2GQ tel. 01628 659 520
Towelrads Lrd.
Unit 4 e 5, Maidenhead Trade Park, Priors Way, wwww.towelrads.comMaidenhead, Berkshire SL6 2GQ tel. 01628 659 520
“SMART 43D”
Electronic control for towel radiators
EN
Release 3 - August 2015
TOWELRADS

(mm)
(W)
(W/Cm )
2
350 350 370 430 450 560 630 700 760 830
100 200 300
1.1 2.3 3.2
400 500 600 700
3.4 4 4.1 3.6 3.6 3.7 3.7
800 900 1000
10
56
L5+
12 0.3+
L(heating elemet)
Power
Watt density
TECHNICAL CHARACTERISTICS
Product
Applications
Insulation class
IP Level
Electronic control for electric towel radiators
Towel radiators
Class I, Class 2
IP44
Operational temperature -10°C ÷ 40°C
Maximal power See table and figure below
Supply Voltage 230VAC 50Hz
Dimensions See table and figure below
Warranty 2years
Standards
ABS-VO
CE
-EN 60335-1:2012+A11:2014 -EN 60335-2-30:2009+A11:2012
-EN 60335-2-43:2003+A1:2006+A2:2008
-EN 61000-3-2:2014 -EN61000-3-3:2013 -EN 62233:2008
-EN 55014-1:2006+A1:2009+A2:2011
-EN 55014-2:1997+A1:2001+A2:2008
Approval mark
Case
Environmental directive WEEE, RoHS
Operative modes Continuous-heating, Boost 2h, Timer 12h, Timer 24h, Stand.by
Boost/Timer led (red/green/amber).
On/Off led (red)
Connection to mains 3 Cables (neutral, live, earth); L.120cm; Italian plug L.120cm;
Cables (neutral, live) Swiss plug L.120cm; Uk plug L.120cm;
Schuko plug L.120cm.
2.
Available colors White (RAL9016); Chrome
Thermostat status indicators
Maximal temperature 43°C
370
250
4
700
700
3.6
i
eat
Towelrads Lrd.
Unit4e5,Maidenhead Trade Park, Priors Way, wwww.towelrads.comMaidenhead, Berkshire SL6 2GQ tel. 01628 659 520
Towelrads Lrd.
Unit 4 e 5, Maidenhead Trade Park, Priors Way, wwww.towelrads.comMaidenhead, Berkshire SL6 2GQ tel. 01628 659 520
“SMART 43D”
Electronic control for towel radiators
EN
Release 3 - August 2015
TOWELRADS

Please read carefully before using the device.
The present device has been designed for exclusive use on a towel radiator.
The thermostat is designed for heating
the liquid contained inside a towel radiator. Any other use is forbidden.
Only use heating elements compatible with the type of used towel radiator
Disconnect power supply before cleaning or before performing maintenance of
the product.
In case of damage supply cable the device and do not . The
damaged power supply cables can be replaced by the manufacturer or by an
authorized service center. Failure to he above rules could
lead to compromised system safety and the warranty.
• Replacement of the heating element can be done exclusively by the product
manufacturer.
•
•
•
in combination with a heating element
Before using, carefully ensure that the line voltage is the same as that specified
for the thermostat (see technical specifications).
to the , turn off touch
either adheres to t
invalidate
Store the heating element exclusively in the protecting packaging.
•
•
•
•
WARNING
RISK OF ELECTRIC SHOCK!
Disconnect power supply before proceeding with installation.
Towelrads Lrd.
Unit4e5,Maidenhead Trade Park, Priors Way, wwww.towelrads.comMaidenhead, Berkshire SL6 2GQ tel. 01628 659 520
Towelrads Lrd.
Unit 4 e 5, Maidenhead Trade Park, Priors Way, wwww.towelrads.comMaidenhead, Berkshire SL6 2GQ tel. 01628 659 520
“SMART 43D”
Electronic control for towel radiators
EN
Release 3 - August 2015
TOWELRADS

1)Insert the heating element in the threaded opening located on the bottom part of the
radiator.
2)Securely fasten the electric resistance to the body of the towel radiator with a 22mm
wrench.
3)The special sheath ensures a secure mounting and eventually allows a slight
supplemental torsion to perfectly align the thermostat with the radiator.
4)Tilt the radiator as in fig. 3, making sure that the opening on top of the radiator is
located on the highest side. WARNING. Do not lean the radiator on the electronic control!
5)Put the radiator back in vertical position and check the internal level of the liquid (fig. 4).
6)Ensure that the element has been securley fastend
7)Connect the device to mains and start heating (the top opening of the radiator must
remain open!).
8)Close the top opening of the radiator with the appropriate cap.
9) Hook the radiator to the wall.
10) Connect the device to the mains.
NO
SI
(1)
(2)
(3)
(4)
• Disconnect the device from power supply before proceeding with installation or
maintanance.
• Protect the device with a 30mA RCD circuit breaker and an isolating switch to disconnect
from the network.
Installation Guide
To be used by installer only
Towelrads Lrd.
Unit4e5,Maidenhead Trade Park, Priors Way, wwww.towelrads.comMaidenhead, Berkshire SL6 2GQ tel. 01628 659 520
Towelrads Lrd.
Unit 4 e 5, Maidenhead Trade Park, Priors Way, wwww.towelrads.comMaidenhead, Berkshire SL6 2GQ tel. 01628 659 520
“SMART 43D”
Electronic control for towel radiators
EN
Release 3 - August 2015
TOWELRADS

"On/Stand-by" LED:
the indicates the
thermostat status
LED
LED "Boost/Timer": red / green
/ amber.
An LED indicates to the user
which functions are active
[Bo st/Timer] button: to
choose among the
modes:
o
"Boost", "Timer12",
"Timer24"
Power cord
1/2" GAS thread
for fastening on
the radiator
Heating element
[On/Stand-by] button
Press the [On/Stand-by] button to power on the device or to activate the "Stand-by"
mode; during the "Stand-by" mode, all LED are off.
"Continuous-heating" mode:
[ON/Stand-by]
[ON/Stand-by]
NOTE:
- The device will beep twice for 0.5 seconds when put into "Standby " mode.
- The device will beep once for 1 seconds when turned on.
it is possible to activate this function through the
button, the heating element is activated and remains active (hence heating
the towel radiator) until the function is deactivated through the button.
From this mode it is possible to activate the functions: "Boost", "Timer12" e "Timer24".
Note: the maximal reachable temperature is 43°C.
TOWELRADS
User manual
Towelrads Lrd.
Unit4e5,Maidenhead Trade Park, Priors Way, wwww.towelrads.comMaidenhead, Berkshire SL6 2GQ tel. 01628 659 520
Towelrads Lrd.
Unit 4 e 5, Maidenhead Trade Park, Priors Way, wwww.towelrads.comMaidenhead, Berkshire SL6 2GQ tel. 01628 659 520
“SMART 43D”
Electronic control for towel radiators
EN
Release 3 - August 2015
TOWELRADS

“Boost” mode: [Boost/Timer]
[Boost/timer]
Press the button to activate this mode.
This mode activates the heating element to the maximum power for 2hrs (maximum
temperature 43°C).
To exit the “Boost” mode press the button.
“Boost” mode indication: "Boost/Timer" LED has red color and it blinks.
Press the button for 3 seconds to activate this mode.
The control system activates the “Boost” mode for 2 hours, after that it returns into
“Stand-by” mode and after 22 hours the “Boost” mode is started again for 2 hours
(maximum temperature 43°C). This sequence will repeat endlessly.
To exit the “Timer24” mode press the button.
NOTE: During the first cycle the duration of the “Stand-by” mode is of 21 hours.
“Timer24” indication during 2hrs “Boost”: “Boost/Timer” LED blinking green.
During 22hrs “Stand-by”: “Boost/Timer” LED permanent green.
“Timer12” mode: Press the button for more than 5 seconds to activate it.
The control system activates the “Boost” mode for 2 hours, after that it returns into
“Stand-by” mode and after 10 hours the “Boost” mode is started again for 2 hours. This
sequence will repeat endlessly. (maximum temperature 43°C)
To exit the “Timer12” mode press the button.
NOTE: During the first cycle the duration of the “Stand-by” mode is of 9 hours.
Timer12 mode (boost 2h): Boost/Timer LED amber and blinking
"Stand-by" mode (12h): Boost/Timer lit and amber
“Timer24” mode: [Boost/Timer]
[Boost/Timer]
[Boost/Timer]
[Boost/Timer]
BOOST 2h
BOOST
Timer 24
BOOST
Timer 12
Stand-by Comfort
Functional diagram
Press once.
Press for 3 seconds
Press for 5 seconds
Towelrads Lrd.
Unit4e5,Maidenhead Trade Park, Priors Way, wwww.towelrads.comMaidenhead, Berkshire SL6 2GQ tel. 01628 659 520
Towelrads Lrd.
Unit 4 e 5, Maidenhead Trade Park, Priors Way, wwww.towelrads.comMaidenhead, Berkshire SL6 2GQ tel. 01628 659 520
“SMART 43D”
Electronic control for towel radiators
EN
Release 3 - August 2015
TOWELRADS

Red lit led
Led off
Functional diagram of the "On/Stand-by" led
Stand-by mode
The thermostats is active
Repairing: they must be carried out by authorized personnel in order not to void the
warranty.
The manufacturer reserves the right to make any changes to the product described in
this manual, at any time, and without prior warning.
DISPOSAL
This product may not be treated as ordinary household waste. It has to be
disposed in proper waste collection sites. In case of replacement it shall be
returned to Towelrads.
Such an end-of-life treatment of the product will preserve the environment and
will reduce consumption of natural resources.
This symbol applied to the present product indicates the obligation to bring it to
a proper waste collection site, in order to let it be disposed according to 2002/96
/ CE (RAEE - WEEE) directives.
Blinking red Boost active. The heating element is active for 120 minutes.
Boost active (Timer24). The heating element is active for 120
minutes.
Return to "Stand-by" mode for 22 hours.
Boost active (Timer12). The heating element is active for 120
minutes.
Return to "Stand-by" mode for 10 hours.amber
Blinking
amber
Green
Blinking green
Functional diagram of the "Boost/Timer" led
Accessory:
Available colors:
For the mixed operation with the Smart control,
mount the “T” accessory in the way back of the
towel radiator, and subsequently introduce into
the vertical manifold of the “T” accessory the
smart, and connect the way back of the
heating circuit to the square connection of the
“T” accessory.
White; Chromed
NOTE: In case of interruption of the power supply the thermostat remains in
"Continuous-heating" mode, with the exception of the modes: "Boost2h", "Timer12h",
"Timer24h", from which the thermostat goes back into "Stand-By"
Towelrads Lrd.
Unit4e5,Maidenhead Trade Park, Priors Way, wwww.towelrads.comMaidenhead, Berkshire SL6 2GQ tel. 01628 659 520
Towelrads Lrd.
Unit 4 e 5, Maidenhead Trade Park, Priors Way, wwww.towelrads.comMaidenhead, Berkshire SL6 2GQ tel. 01628 659 520
“SMART 43D”
Electronic control for towel radiators
EN
Release 3 - August 2015
TOWELRADS
Table of contents