manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Toyama
  6. •
  7. Security Sensor
  8. •
  9. Toyama T 76 252 User manual

Toyama T 76 252 User manual

Page - 1
MOVEMENT SENSOR 180°(WALL MOUNTING)
T 76 252
Technical Manual
Toyama Movement sensors are intelligent lighting control energy saving sensitivity detectors. Movement
sensors use Passive infrared (PIR) sensor to detect the human movement and make corresponding triggering of
loads, say lights. Usage of SMD components not only ensures reliability but also makes the product highly
compact for its functionality and features. Wide operating voltage range of the Movement sensors makes it
operational across countries from North America having 127V supply to European countries with 230V supply
without any field setting. The device is incorporated with the adjustable inbuilt timer to switch OFF the load when
there is no human movement. The device is also incorporated with Lux detector.
Applications: Movement sensors can be installed in
•Office /Hotel corridors.
•Stair cases/Passage.
•Stores, Classrooms.
•Common fresh rooms.
SPECIFICATIONS:
Supply voltage : 110 - 250V/AC
Supply frequency : 50-60 Hz
Rated load : 1200W
Detection angle : 180 °
Detection distance : 20 feet
Installation height : 8-9 feet optimum
Detection motion speed : 0.6 - 1.5m/s
Time – delay : Minimum: 30 sec / Maximum: 450 sec
Lux adjustment level : 10 – 400 lux
Power consumption : 0.45W (Static 0.1W)
Operating Temperature : 0 - 55°C
Standard color of Movement sensor : White
Adjust day/night or
night mode
Adjust delay time from
30 seconds min(-) to
450 seconds max(+)
Page - 2
Please read the instructions before installing:
•Movement sensors should be preferably installed by a trained electrician who can understand the
installation procedure and guidelines.
•Ensure wires are properly connected with reference to phase, neutral and load.
•Concentrated Light from IR emitting fluorescent lamps should not fall on the sensor window, which
may disturb the sensing operations. As such ensure a minimum distance of around 3 meters between
the florescent lamp and the movement sensor.
•Install the movement sensor only at the specified height
•Install the movement sensor in such a way that the detection range is angled across the movement.
•Use only transformers/Ballast made to IEC or equivalent standards by manufacturers of repute.
•If required connect 2.2uF/440V AC Fan Capacitor across CFL with electronic ballasts to avoid blinking
in OFF state.
•Connect upto specified wattage of load only. For higher loads suitable rated contactor of reputed make
can be used.
•Hindrance / moving object should not hide the detection window.
•Avoid installing in Bathrooms. Make sure air conditioners, central heating, etc.do not cloud IR window.
INSTALLATION OF MOVEMENT SENSOR– Steps:
1.Turn OFF power through the MCB.
2.Remove the bottom lid from the sensor by loosening the screws.
3.Fix the bottom lid in the selected position with the inflated screws
4.Connect the movement sensor as per the wiring diagram shown below.
5.Mount the sensor on the bottom lid and screw it.
6. Turn ON power through the MCB.
WIRING DIAGRAM OF MOVEMENT SENSOR:
PHASE (BROWN)
NEUTRAL (BLUE)
TO LOAD ( RED)
TO NEUTRAL
LOAD
Note: Use 0.75 Sq.mm.flexible wires for connections (Phase, neutral & load)
Page - 3
OPERATION:
♦Detection field: The detection field is made up of up and down, left and right service field. (See
the following diagram). But it has the relation ship between the sensitivity and the orientation of
moving. Detection distance can be set according to the installation position and detection field.
♦Time-delay adjustment: The timer knob can be set according to the customer needs. The
minimum is 30 sec. and the maximum is 450 sec delay OFF.
♦Identifies day and night automatically: When the trimmer knob is turned towards SUN Position
(max), it can work at the day and night. When turned towards MOON position (min), the sensor will
only at night (less than 10LUX ambient light)
c
Wrong
Movement
Detection Field Orientation
o
r
r
e
c
t
m
o
v
e
m
e
n
t
At a distance closer to the sensor, even slow movement can be detected. As the movement is away from the
sensor, the space between the zones of sensitivity increases, and therefore the amount of motion required to
trigger the device increases.
Page - 4
TROUBLE SHOOTING:
Symptom Possible cause Remedies
Lights do not ON
•Light(s) burned out.
•Breaker is OFF or tripped.
•Wiring error
•Lux level adjuster (Photo) may
be in moon mode.
•Replace the bulbs
•Switch ON the breaker.
•Check and correct the connections
•Turn the lux level adjuster (photo)
fully clockwise.
Sensitivity is poor
•Installation height may be high.
•Incorrect moving orientation
•Obstruction in front of sensor
window
•Install at recommended height.
•Correct moving orientation
•Remove the obstruction in front of
the window
DIMENSIONS:
60,00
73,00
ALL DIMENSIONS ARE IN mm

This manual suits for next models

3

Popular Security Sensor manuals by other brands

Mastech MS5905RTB manual

Mastech

Mastech MS5905RTB manual

Siemens FDT181 product manual

Siemens

Siemens FDT181 product manual

LightPro 227A user manual

LightPro

LightPro 227A user manual

ZANTINGH CO Quick setup guide

ZANTINGH

ZANTINGH CO Quick setup guide

Markes International C-HLD Instructions for use

Markes International

Markes International C-HLD Instructions for use

IDS NXT quick start guide

IDS

IDS NXT quick start guide

Megger VF5 user guide

Megger

Megger VF5 user guide

Aritech DD66X Series Installation sheet

Aritech

Aritech DD66X Series Installation sheet

Kontron HPLC Detector 430 instruction manual

Kontron

Kontron HPLC Detector 430 instruction manual

Theben SPHINX 331 S KNX quick start guide

Theben

Theben SPHINX 331 S KNX quick start guide

PCB Piezotronics ICP M260A01 Installation and operating manual

PCB Piezotronics

PCB Piezotronics ICP M260A01 Installation and operating manual

Kanlux DECK CO quick start guide

Kanlux

Kanlux DECK CO quick start guide

Chuango PIR-926 user manual

Chuango

Chuango PIR-926 user manual

Viessmann 5206 Operation manual

Viessmann

Viessmann 5206 Operation manual

BUCKINGHAM MFG 488 Series Replacement instructions

BUCKINGHAM MFG

BUCKINGHAM MFG 488 Series Replacement instructions

Safety 1st HS038 quick start guide

Safety 1st

Safety 1st HS038 quick start guide

Vimar NEVE UP 09467 manual

Vimar

Vimar NEVE UP 09467 manual

Wenglor U2GT Series operating instructions

Wenglor

Wenglor U2GT Series operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.