Trader NEAR BESMOKEY10BW User manual

Cleaning Guide:
Spraying cleaning products on to
electrical products is not recommended.
It is important to ensure that switches are
turned o before cleaning.
Do not use any cleaning sprays - only
wipe down with damp cloth or rub with
dry cloth. (Do not use an abrasive cloth as
it may scratch the plastic).
Do not use harsh chemical cleaners as
these can break down the plastic and
cause it to crack.
www.gsme.com.au
1
BEAR
Bear Photoelectric Smoke Alarm
Wireless (Non Removable)
Lithium Battery Only
• Photoelectric Sensing Technology.
• Activre Listed.
• Complies with AS3786:2014.
• Main power source: Built-in DC3V Lithium battery (battery not replaceable).
• Interconnection Max. 40 alarms.
• Wireless distance Max. 100 metres in free eld.
• Wireless Frequency test 433.42MHZ
• Suitable for Ceiling or Wall Mounting.
• Alarm volume ≥ 85dB(A) @ 3m complying with ISO8201 alarm pattern.
• Operating Temperature 0 °C - 45 °C.
• Maximum humidity for installation: < 93 % Relative Humidity.
• Central test & Activation Button.
• Red LED Alarm Status Indication.
• Insect Screen protects Sensing Chamber.
• Sleek Styling.
• The BESMOKEY10BW can also pair to BESMOKEY10 with BESMOKEY10WM installed.
• 10 Year warranty.
Certication Number:
Active Fire: afp-3735
GSM Electrical (Australia) Pty Ltd
Level 2, 142-144 Fullarton Road, Rose Park SA 5067
October 2022
Catalogue Number Description
BESMOKEY10BW Smoke Alarm Wireless Interconnect Photoelectric Surface Mount Non
Removable 3V DC Lithium 10 Year Battery Only
BESMOKEY10BW
*See currrent catalogue for further detail
Page 1 of 2
35.5mm
114mm
LED Indicator
Test & Activation Button
Sount Output
BESMOKEY10 Smoke Alarms come
with a 10 Year Warranty from date of
purchase. BESMOKEY10 Accessories
are warranted for 7 Years from date
of purchase. Proof of Purchase is
required for Warranty Claims
– please see www.gsme.com.au for
details regarding warranty claims.

Cleaning Guide:
Spraying cleaning products on to
electrical products is not recommended.
It is important to ensure that switches are
turned o before cleaning.
Do not use any cleaning sprays - only
wipe down with damp cloth or rub with
dry cloth. (Do not use an abrasive cloth as
it may scratch the plastic).
Do not use harsh chemical cleaners as
these can break down the plastic and
cause it to crack.
www.gsme.com.au
2
BEAR
BESMOKEY10BW
*See currrent catalogue for further detail
Page 2 of 2
Bear Photoelectric Smoke Alarm
Wireless (Non Removable)
Lithium Battery Only
Certication Number:
Active Fire: afp-3735
GSM Electrical (Australia) Pty Ltd
Level 2, 142-144 Fullarton Road, Rose Park SA 5067
October 2022
BESMOKEYREM can be installed on wireless network for convenient control.
NETWORK CONFIGURATION EXAMPLE
BESMOKEY10
(wired)
240V~
MASTER
BESMOKEY10 (wired)
+ BESMOKEY10WM
240V~ Connected
BESMOKEY10
+ BESMOKEY10WM
BESMOKEY10BW
BESMOKEY10BW can be used with BESMOKEY10REM.
BESMOKEY10BW is also net-workable with BESMOKEY10 with
BESMOKEY10WM INSTALLED.
Example of a network using BESMOKEY10BW and BESMOKEY10 combined with hard wired
and interconnected (using cable) with a single“master” alarm with the BESMOKEY10MW
module tted communicating with others in the system that are operating from the
10 Year Lithium battery.
BESMOKEY10 Smoke Alarms come
with a 10 Year Warranty from date of
purchase. BESMOKEY10 Accessories
are warranted for 7 Years from date
of purchase. Proof of Purchase is
required for Warranty Claims
– please see www.gsme.com.au for
details regarding warranty claims.

Cleaning Guide:
Spraying cleaning products on to
electrical products is not recommended.
It is important to ensure that switches are
turned o before cleaning.
Do not use any cleaning sprays - only
wipe down with damp cloth or rub with
dry cloth. (Do not use an abrasive cloth as
it may scratch the plastic).
Do not use harsh chemical cleaners as
these can break down the plastic and
cause it to crack.
www.gsme.com.au
3
BEAR
Bear Photoelectric Smoke Alarm
Wireless Ready
• Photoelectric Sensing Technology.
• Activre Listed.
• Complies with AS3786:2014.
• Main power source 220-240 V AC 50 Hz.
• Secondary power source DC 3V battery 10 Year Lithium.
• Interconnection Max. 24 alarms (wired 150m maximum).
• Wireless upgradeable by clipping in BESMOKEY10WM and linking with other
alarms that also contain the module.
• 4 hard wired Terminals that accommodate 2 x 2.5mm2 (A, E-Loop, N , I-connect)
for hard wired applications.
• Surface Mount Base Plate with Large Cable Terminals.
• Suitable for Ceiling or Wall Mounting.
• Alarm volume ≥ 85dB(A) @ 3m complying with ISO8201 alarm pattern.
• Operating Temperature 0 °C to 40 °C.
• Maximum humidity for installation: 5-95% Relative Humidity.
• Red LED Alarm Status Indication.
• Green LED AC Mains Power Indication.
• Separate test and Hush Buttons to assist with wireless linking.
• Insect Screen protects Sensing Chamber.
• Sleek Styling.
• The BESMOKEY10 with BESMOKEY10WM can also pair to BESMOKEY10BW 10 Year Lithium
Wireless Smoke Alarm.
• 10 Year warranty.
Certication Number:
Active Fire: afp-3688
GSM Electrical (Australia) Pty Ltd
Level 2, 142-144 Fullarton Road, Rose Park SA 5067
October 2022
Catalogue Number Description
BESMOKEY10 Smoke Alarm Photoelectric Surface Mount 220-240V AC 3V DC Lithium 10 Year
Battery Wireless Interconnect Ready 4 Terminals
BESMOKEY10
*See currrent catalogue for further detail
Page 1 of 2
BESMOKEY10 Smoke Alarms come
with a 10 Year Warranty from date of
purchase. BESMOKEY10 Accessories
are warranted for 7 Years from date
of purchase. Proof of Purchase is
required for Warranty Claims
– please see www.gsme.com.au for
details regarding warranty claims.

Cleaning Guide:
Spraying cleaning products on to
electrical products is not recommended.
It is important to ensure that switches are
turned o before cleaning.
Do not use any cleaning sprays - only
wipe down with damp cloth or rub with
dry cloth. (Do not use an abrasive cloth as
it may scratch the plastic).
Do not use harsh chemical cleaners as
these can break down the plastic and
cause it to crack.
www.gsme.com.au
4
BEAR
BESMOKEY10
*See currrent catalogue for further detail
Page 2 of 2
Bear Photoelectric Smoke Alarm
Wireless Ready
Making BESMOKEY10 Wireless:
To make wireless, before removing battery tag add BEMOKEY10MW, then connect battery and
power. Follow instruction to pair the wireless alarms in the network.
Example of a network using BESMOKEY10 combined with hard wired and interconnected (using
cable) with a single “master” alarm with the BESMOKEY10MW module tted communicating with
others in the system that are operating from the 10 Year Lithium battery.
Certication Number:
Active Fire: afp-3688
GSM Electrical (Australia) Pty Ltd
Level 2, 142-144 Fullarton Road, Rose Park SA 5067
October 2022
BESMOKEY10WM
Pluggable module
BESMOKEYREM can be installed on wireless network for convenient control.
NETWORK CONFIGURATION EXAMPLE
BESMOKEY10
(wired)
240V~
MASTER
BESMOKEY10 (wired)
+ BESMOKEY10WM
240V~ Connected
BESMOKEY10
+ BESMOKEY10WM
BESMOKEY10BW
BESMOKEY10 Smoke Alarms come
with a 10 Year Warranty from date of
purchase. BESMOKEY10 Accessories
are warranted for 7 Years from date
of purchase. Proof of Purchase is
required for Warranty Claims
– please see www.gsme.com.au for
details regarding warranty claims.

Cleaning Guide:
Spraying cleaning products on to
electrical products is not recommended.
It is important to ensure that switches are
turned o before cleaning.
Do not use any cleaning sprays - only
wipe down with damp cloth or rub with
dry cloth. (Do not use an abrasive cloth as
it may scratch the plastic).
Do not use harsh chemical cleaners as
these can break down the plastic and
cause it to crack.
www.gsme.com.au
5
BEAR
7
Warranty
7
Warranty
Yr
Yr
BESMOKEY10WM
*See currrent catalogue for further detail
BESMOKEY10WM Wireless Module
• Application: Suitable for TRADER BESMOKEY10 220-240V a.c. smoke alarm .
• Wireless Distance: >60m (clear line of sight).
• Frequency: 433.42MHz.
• Interconnection capacity: Maximum 40 devices .
• Size: 45 x 35 x 26mm.
• Temp range: 0°C - 45°C .
• Max Humidity: 5-95%RH.
• Wireless module complies with AS/NZS4268.
• Alarm Signal Pattern when installed in BESMOKEY10: ISO 8201 and AS 3786:2014 compliant
Introducing Wireless Alarm Option into the network with the BESMOKEY1 0WM module.
• This module can be installed into the BESMOKEY10 by rst disconnecting the power and opening
one of the mains powered alarms, do this before removing the yellow tag for the battery, replace
the blank housing with the BESMOKEY10WM wireless module then remove battery tag to
connect power.
• The BESMOKEY10WM communicates at 433.42MHz and can operate at range greater than 60m.
• With the power o select one mains wired alarm to be the master for the wireless link and install
the BESMOKEY10WM.
• The BESMOKEY10 with BESMOKEY10WM can also pair to BESMOKEY10BW 10 Year Lithium
Wireless Smoke Alarm.
Caution: Only install one pluggable BESMOKEY10WM module into a group of mains-wired
interconnected alarms. If there is more than one installed with wired connections, it will
not work. Follow the instructions provided to pair the wireless alarms in the network.
Certication Number:
Active Fire: afp-3688 with BESMOKEY10
GSM Electrical (Australia) Pty Ltd
Level 2, 142-144 Fullarton Road, Rose Park SA 5067
October 2022
Making BESMOKEY10 Wireless:
To make wireless, before removing battery tag add BEMOKEY10MW, then connect battery and
power. Follow instruction to pair the wireless alarms in the network.
Example of a network using BESMOKEY10 combined with hard wired and
interconnected (using cable) with a single “master” alarm with the BESMOKEY10MW
module tted communicating with others in the system that are operating from the 10
Year Lithium battery.
BESMOKEY10WM
Pluggable module
NETWORK CONFIGURATION EXAMPLE
BESMOKEY10
(wired)
240V~
MASTER
BESMOKEY10 (wired)
+ BESMOKEY10WM
240V~ Connected
BESMOKEY10
+ BESMOKEY10WM
BESMOKEY10BW
BESMOKEY10 Smoke Alarms come
with a 10 Year Warranty from date of
purchase. BESMOKEY10 Accessories
are warranted for 7 Years from date
of purchase. Proof of Purchase is
required for Warranty Claims
– please see www.gsme.com.au for
details regarding warranty claims.

Cleaning Guide:
Spraying cleaning products on to
electrical products is not recommended.
It is important to ensure that switches are
turned o before cleaning.
Do not use any cleaning sprays - only
wipe down with damp cloth or rub with
dry cloth. (Do not use an abrasive cloth as
it may scratch the plastic).
Do not use harsh chemical cleaners as
these can break down the plastic and
cause it to crack.
www.gsme.com.au
6
BEAR
7
Warranty
7
Warranty
Yr
Yr
BESMOKEY10REM
*See currrent catalogue for further detail
Bear Smoke Alarm Wireless Remote
for BESMOKEY10 with Wireless
Module (BESMOKEY10WM) installed
and BESMOKEY10BW
• Works with the BESMOKEY10 with Wireless Module (BESMOKEY10WM) installed and also
BESMOKEY10BW.
• Complies with AS/NZS 4268.
• Power source DC 3V (CR2450) Lithium Button Battery.
• Wireless distance > 5 meters depending on surroundings.
• 433.42MHz Wireless frequency.
• Size 53.1mm x 61.9 mm x 16.3mm.
• Interconnection Max. 40 devices.
• Humidity Range ≤95% relative humidity (RH).
• Standby current ≤3uA Operation.
• Current ≤30mA.
• Operating temperature 0~45˚C.
• “Test” button sends the test alarm signal to the smoke alarm.
• “Locate” button detected the smoke alarm is sounding and operating in the alarm status.
• “Hush” button locates the alarm that has initiated the alarm mode situation
and hush the smoke alarm for 10 minutes.
• “SOS”button to activate the alarm network and use them to alert people
to a non-re-related emergency.
• 10 year Battery Lifetime.
Warning:
The BESMOKEY10REM is not a toy and should be used carefully.
Do not immerse in water or liquids.
The product contains a Lithium button battery that is hazardous and should be kept
away from children. The batter may cause fatal injury if swallowed and immediate
medical attention should be sought.
If the BESMOKEY10REM is not functioning, please ensure the plastic tab has been
removed from the battery compartment. It there is a need to change the battery
for any reason, do not handle the battery surfaces with ngers as this may aect the
performance as shown below.
GSM Electrical (Australia) Pty Ltd
Level 2, 142-144 Fullarton Road, Rose Park SA 5067
October 2022
Battery Warranty
Changing the Battery:
BESMOKEY10 Smoke Alarms come
with a 10 Year Warranty from date of
purchase. BESMOKEY10 Accessories
are warranted for 7 Years from date
of purchase. Proof of Purchase is
required for Warranty Claims
– please see www.gsme.com.au for
details regarding warranty claims.

BEAR
Photoelectric Smoke Alarm
with Hinged Base Plate, 4 Terminals
• Operate as Single or Inter-connect up to 24 units
Operation: This smoke alarm operates as a single unit and/or
interconnects up to 24 other units. This smoke alarm is not
designed to be interconnected with other products
or accessories unless specied.
• Photoelectric Sensing Technology
• Activre Listed
• Tested and Approved to AS3786:2014
• 240V~ AC with 9V DC Battery Backup
• Surface Mount Base Plate with Large Cable Terminals
• Suitable for Ceiling or Wall Mounting
• Fits BESMOKEY4SK Skirt to replace larger detectors
and not leave paint marks
• Available in white or black - please check availability
• Red LED Alarm Status Indication
• Green LED AC Mains Power Indication
• Loud 85dBA Warning Siren
• Repeat 3 Long Beeps (ISO 8201) Indicated that
particles of combustion have been detected
• Single Test and Hush Button
• Warning for Low Battery
• Anti-Tamper Feature
• Insect Screen protects Sensing Chamber
• Sleek Styling
• 10 year warranty (does not include battery)
BESMOKEY4
BESMOKEY4BK
BESMOKEY4SK
BESMOKEY4SKBK
Certication Number:
XF3339/R1
XF3229/R1
GSM Electrical (Australia) Pty Ltd
Level 2, 142-144 Fullarton Road, Rose Park SA 5067
June 2022
www.gsme.com.au
BEAR
Cleaning Guide:
Spraying cleaning products on to
electrical products is not recommended.
It is important to ensure that switches are
turned o before cleaning.
Do not use any cleaning sprays - only
wipe down with damp cloth or rub with
dry cloth. (Do not use an abrasive cloth as
it may scratch the plastic).
Do not use harsh chemical cleaners as
these can break down the plastic and
cause it to crack.
Do not wash the cover plates in water
over 60°C.
Smoke Alarm Skirt
• Perfect for covering miss matched paint marks
from old smoke detectors
• Covers Ø145mm
• 80mm & 83.5mm Hole Centres
Detector needs to have base wired prior to installing skirt
48mm
130mm
Simply push and rotate BESMOKEY4 Smoke Alarm into place
145mm
107.6mm
56mm
4mm
7
Table of contents
Other Trader Smoke Alarm manuals
Popular Smoke Alarm manuals by other brands

FAAST
FAAST 9400XE FAAST user guide

Firex
Firex i4618A Series user guide

Xtralis
Xtralis VESDA Commissioning Guide

Notifier
Notifier NFX-OPT Installation and maintenance instructions

System Sensor
System Sensor 2112 Installation and maintenance instructions

Kidde
Kidde SMOKE AND CARBON MONOXIDE ALARM user guide